Loading...
HomeMy WebLinkAbout265.00GENERAL NOTES:1.ABANDONED UTILITIES WITHIN FOOTPRINT OF FACILITY AND OBSERVED DURING CONSTRUCTION MUST BE REMOVED. COORDINATE WITH MUNICIPAL OR PRIVATE OWNER AND ENGINEER.2.HORIZONTAL SEPARATION BETWEEN WATER MAIN WALL AND TOP OF SLOPE OF THE BIORETENTION FACILITY SHALL BE NO LESS THAN 7 FEET.3.FIRE HYDRANTS SHALL BE AT LEAST 5 FEET FROM BIORETENTION FACILITY FOOTPRINT.4.WATER METER SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.5.MANHOLES SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.6.A MINIMUM OF 1 FOOT SEPARATION BETWEEN SANITARY SEWER CROSSINGS AND UNDERDRAINS SHALL BE MAINTAINED.7.UTILITY SERVICE AND UTILITY MAIN CROSSINGS SHALL BE MADE PERPENDICULAR TO THE BIORETENTION FACILITY.8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.1' MIN. CURB CUT TOEDGE OF CATCH BASINA,B,C265.10UTILITY MAINCROSSINGCATCH BASINUTILITY SERVICECROSSINGOPTIONAL UTILITY TRENCH DAM (TYP.),DESIGNER TO SPECIFYBIORETENTION FACILITYD 265.10UTILITY CROSSINGS - BIORETENTIONSTD. PLAN - 265.00PUBLIC WORKSDEPARTMENTAPPROVED:DATEGregg ZimmermanPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA6388789/28/2018 | 9:45 AM PDT