HomeMy WebLinkAboutR-394709GENERAL UTILITY NOTES SANITARY SEWER STRUCTURES NE1/4OFS32,T23N, R 5 E d� co 0 W 1. ALL IMPROVEMENTS SHALL MEET LOCAL, STATE DOT AND A.P.W.A. STANDARD SPECIFICATIONS. 2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON SURVEY PREPARED BY PACE ENGINEERS, INC., DATED 1/16/2015. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY, AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND DIMENSIONS OF VESTIBULE, SLOPED PAVING, EXIT PORCHES, SIDEWALKS, RAMPS AND TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 5. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES. 6. ALL FILL MATERIAL SHALL BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES. 7. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES INSPECTORS 72 HOURS BEFORE CONNECTING TO ANY EXISTING LINE. 8. MINIMUM WATER AND SANITARY SEWER TRENCH WIDTH SHALL BE 2 FEET. 9. ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE). 10. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATERLINES, SANITARY LINES, STORM LINES AND GAS LINE (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATERLINE SHALL BE MECHANICAL JOINTS WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" CLEARANCE, MEETING REQUIREMENTS OF ANSI A21.10 AND ANSI 21.11 (AWWA C-151) (CLASS 50). 11. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING. 12. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH THE SPECIFICATIONS OF THE LOCAL AUTHORITIES WITH REGARD TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. 13. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION OF SERVICE. 14. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 15. CONTRACTOR TO PROVIDE TRENCHING, BACKFILL, 2 - 4" PVC SCHEDULE 40 CONDUITS, AND PULLING WIRES FOR UNDERGROUND TELEPHONE SERVICE FROM EXISTING FACILITIES AS SHOWN ON PLANS. CONTRACTOR TO COORDINATE INSTALLATION AND POINT OF CONNECTION WITH UTILITY PROVIDER. 16. CONTRACTOR IS TO PROVIDE TRENCHING, CONDUIT, AND BACKFILL FOR ALL UNDERGROUND POWER LINE AND VAULTS AS REQUIRED BY UTILITY PROVIDER. POWER LINES AND POLES TO BE INSTALLED BY UTILITY PROVIDER. SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING AND FOR PRIMARY ELECTRIC SERVICE LOCATIONS. 17. GAS, ELECTRICAL, AND COMMUNICATIONS UTILITIES SHOWN FOR COORDINATION ONLY. INSTALLATION TO BE ACCOMPLISHED BY UTILITY PROVIDER. WATER NOTES 1. ALL CONSTRUCTION/INSTALLATION OF WATER MAINS SHALL BE DONE IN A SAFE, NEAT AND WORKMANLIKE MANNER, AND UNDER SUPERVISION BY UTILITY PROVIDER FORCES AT ALL TIMES. ALL SAFETY REQUIREMENTS FROM OSHA AND OTHER STATE REGULATING AGENCIES MUST BE MET. 2. WATER MAIN PIPE MATERIAL SHALL BE CLASS 52 DUCTILE IRON OR PVC PIPE MEETING LOCAL REQUIREMENTS. POLYETHYLENE WRAP IS REQUIRED ON ALL METALS. 3. AN 18-INCH MINIMUM SEPARATION IS REQUIRED ON SERVICE TAPS ON A MAIN LINE. 4. CLASS 52 DUCTILE IRON MAY BE DIRECT TAPPED FOR 3/4 INCH AND 1-INCH SIZE SERVICES. SADDLES SHALL BE USED ON ALL TAPS 1-1/4" - 2" DIAMETER IN ANY PUBLIC MAIN. 5. ALL ELBOWS/BENDS ON WATER MAINS SHALL HAVE THRUST BLOCKS. 6. A DEPTH OF 36" FROM FINISHED GRADE TO THE TOP OF THE WATER MAIN IS REQUIRED. PLACING WATER LINES SHALLOWER THAN 36" IS PROHIBITED. 7. ALL NEW PIPES MUST BE PROPERLY FLUSHED, PRESSURE TESTED, AND CHLORINATED BY THE CONTRACTOR, AND INSPECTED BY UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH JURISDICTION. 8. ALL BACKFLOW PREVENTION DEVICES (DOUBLE CHECK BACKFLOW PREVENTORS, REDUCED PRESSURE BACKFLOW PREVENTORS, PRESSURE AND ATMOSPHERIC VACUUM BREAKERS, ETC.) MUST BE APPROVED BY THE UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH JURISDICTION. 9. ALL NEW CONNECTIONS TO EXISTING WATER MAINS REQUIRE ISSUANCE OF A PUBLIC WORKS PERMIT AND INSPECTION BY THE CITY OR GOVERNMENTAL AGENCIES WITH JURISDICTION PRIOR TO BACKFILLING. 10. BACKFLOW PREVENTION DEVICES SHALL BE CONSTRUCTED OF CORROSION RESISTANT MATERIALS. 11. EXTERNAL WATER METER AND BACKFLOW PREVENTION VAULTS SHALL BE GASKETED IN AREAS OF HIGH GROUNDWATER OR NEAR STORMWATER MANAGEMENT FACILITIES AS REQUIRED BY THE UTILITY PROVIDER, CONTRACTOR TO CONFIRM. SOOS CREEK WATER AND SEWER NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS OF THE SOOS CREEK WATER & SEWER DISTRICT, ALSO REFERRED HEREINAFTER AS "DISTRICT". 2. THE DEVELOPER SHALL FURNISH THE DISTRICT A COPY OF THE COMMERCIAL AND/OR SUBDIVISION PLANS APPROVED BY THE GOVERNING AGENCY PRIOR TO ANY SEWER MAIN CONSTRUCTION. 3. PRIOR TO CONSTRUCTING ANY SEWER MAINS, THE APPROPRIATE STREETS AND LOTS SHALL BE CLEARED, GRADED, AND STAKED BY THE DEVELOPER/CONTRACTOR AND ALL EXISTING UTILITIES SHALL BE LOCATED. 4. FOLLOWING SEWER MAIN CONSTRUCTION, ANY REVISION OF ROADWAY OR EASEMENT GRADES REQUIRING THE MAINS TO BE RECONSTRUCTED SHALL BE MADE AT THE DEVELOPER'S/CONTRACTOR'S EXPENSE. 5. RECONSTRUCTION SHALL CONFORM TO THE SPECIFICATIONS OF THE DISTRICT. ALL COSTS FOR INSPECTING SUCH RECONSTRUCTION SHALL BE CHARGED TO THE DEVELOPER IN ADDITION TO THE STANDARD CHARGES, AND SHALL BE PAID BEFORE ACCEPTANCE BY THE DISTRICT. 6. NO SIDE SEWER CONNECTIONS SHALL BE MADE TO THE EXISTING SYSTEM UNTIL COMPLETION OF THE BILL OF SALE AND ALL EASEMENTS. OBTAIN SIDE SEWER PERMITS FROM THE DISTRICT FOR EACH SIDE SEWER CONNECTION PRIOR TO MAKING CONNECTION. BILL OF SALE WILL NOT BE PROCESSED UNTIL PUGET SOUND ENERGY HAS EITHER PROVIDED A WORK SKETCH OR INSTALLED THEIR VAULTS, HAND HOLES AND LIGHT M STANDARDS, OR THE DEVELOPER HAS PROVIDED A SIGNED HOLD HARMLESS AGREEMENT (FORM SUPPLIED BY THE DISTRICT). 7. ALL COSTS OF SEWER MAIN RE -STAKING SHALL BE PAID BY THE DEVELOPER/CONTRACTOR. 8. PROPERTY CORNERS SHALL BE PINNED WITH REFERENCE TACK ON CURBS BY THE DEVELOPER/CONTRACTOR. f 9. THE DEVELOPER/CONTRACTOR SHALL NOTIFY THE DISTRICT AT (253) 630-9900 TO SCHEDULE A PRE -CONSTRUCTION MEETING AT THE DISTRICT m OFFICE. AFTER THE PRE -CONSTRUCTION MEETING, THE DEVELOPER/CONTRACTOR SHALL NOTIFY THE DISTRICT'S FIELD REPRESENTATIVE AT LEAST 48 HOURS (REGULAR WORKING DAYS) BEFORE STARTING WORK. 10, THE DEVELOPER/CONTRACTOR SHALL OBTAIN ALL REQUIRED FINAL INSPECTIONS TO MEET PERMIT REQUIREMENTS. INSPECTIONS MUST BE SCHEDULED � AT LEAST 48 HOURS IN ADVANCE. 0 11. CONNECTIONS TO EXISTING SEWER MAINS SHALL BE MADE ONLY WITH WRITTEN APPROVAL OF THE DISTRICT AND ONLY AFTER AT LEAST 48 HOURS (TWO REGULAR WORKING DAYS) ADVANCE NOTICE. 12. EXISTING SEWERS TO REMAIN IN SERVICE AT ALL TIMES. 13. ALL WATER AND/OR CONSTRUCTION DEBRIS SHALL BE REMOVED FROM NEW SEWERS AND SHALL NOT BE PERMITTED TO ENTER THE EXISTING SYSTEM. 14. EXISTING MANHOLES SHALL BE CORE -DRILLED AND RE -CHANNELED AS REQUIRED TO RECEIVE INCOMING FLOW FROM THE NEW SEWER. w a `1 a z Z 0 z w z C z D Q O C9 Z N 1505 Westlake Ave. N. C0 Suite 305 z Seattle, WA 98109 Imo,, I ,J T (206)522-9510 F (206)522-8344 WWW.PAcLAND.COM 061 n SSMH n SSCO "�' n SSCO 5 n SSCOn v� `�� SSCO IM=399.46 RIM=400.74 RRIM=400.62 RIM=400.83 RIM=401.15 IE 6" (E)=391.98 IE 6"=395.56 IE 6"=395.20 IE 6"=392.42 IE 6"=394.32 E 6" IE (W =391. 8 02 SSCO 04 SSCO Os SSCO o8 SSCO 10 SSDR RIM=400.83 RIM=400.98 IM=400.98 RIM=400.91 RIM=401.02 IE 6"=392.30 IE 6"=396.36 IE 6"=396.50 IE 6"=393.42 IE 6"=397.12 c v UT C_ 0 23LF 6" SS @ 2. o� U 07 uu� I1F=7F=7F=__ 10OLF 6" SS @ 1.0% 0 -• 0 wa 90LF 6" SS © 1.0% Kel D__ UP _Up� -ST ST I ST ST ' I- "•' l�T aNd!JNCIV01 - J )IWVj ON 02 H 08 IW 56LF 6" SS @ 5. 0 X one UP P ° o " + H O6 8,261 SF I FFE 401.00 *12 ON 3 13LF 6" SS F S 14~CON © 10.0% C _) j D 10 . G X (2)18"CI yy G G G G G G G G �- r GRAPHIC SCALE 6" FIRE LINE SERVICE 1" DOMESTIC 20 0 10 20 40 80 II I I I I WATER SERVICE CONSTRUCTION KEY NOTES 1 i IN FEET ) nch = 20 ft. OA EXISTING WATER SERVICE AND METER TO BE 2 OH INSTALL SANITARY SEWER CLEANOUT. ©FIRE DEPARTMENT CONNECTION RETAINED. CONTRACTOR TO HAVE FLOW TEST PERFORMED PRIOR TO CONSTRUCTION TO ODD- COMM PEDESTAL VERIFY ADEQUATE FLOW AND PRESSURE ,CONNECT TO EXISTING TELECOM ®EXISTING IRRIGATION DOUBLE CHECK VALVE TO SERVICE. CONTRACTOR TO COORDINATE WITH BE RETAINED. ABANDON LINE PAST THIS VALVE. © CONNECT TO EXISTING WATER SERVICE, SERVICE PROVIDER FOR NEW CONNECTION. 2 COORDINATE W/SCWSD. CUT, CAP, AND REMOVE C-7.o ®FIRE HYDRANT WATER LINE PAST POINT OF CONNECTION. O LANDSCAPE IRRIGATION POINT OF CONNECTION. C SEE IRRIGATION PLANS FOR CONTINUATION. OS ROOF TO BE INSTALLED ABOVE DUMPSTER, SEE DOMESTIC WATER SERVICE POINT OF O BUILDING PLANS CONNECTION SEE MEP PLANS FOR 3 � 1,000-GALLON OIL/WATER SEPARATOR C 5.1 T CUT AND CAP EXISTING SEWER. CONTINUATION. L SANITARY SEWER POINT OF CONNECTION SEE 0 3 D AREA DRAIN, NYLOPLAST INLINE DRAIN OR C-5.o MEP PLANS FOR COORDINATION. ' Q��TSANITARY TARY SEWER MANHOLE, CONNECT TO EEQUIVALENT. SEWER STUB, CONTRACTOR TO RELOGATED POWER POLE, CONNECT OE CONNECT FIRE LINE TO EXISTING WATER MAIN. TO EXISTING ELECTRICAL. CONTRACTOR TO VERIFY EX LOCATION AND ELEVATION OF FIRE SERVICE POINT OF CONNECTION. SEE COORDINATE WITH SERVICE PROVIDER FOR NEW C 1 OV INSTALL DOUBLE CHECK DETECTOR ASSEMBLY MEP/FIRE PROTECTION PLANS FOR CONNECTION. CONTINUATION. ON INSTALL RPBA WITH HOT BOX. DIMENSIONS: 26" � TRASH ENCLOSURE DRAINAGE PIPE, NOT TO © CONNECT TO EXISTING GAS SERVICE LINE. X 10" X 22" RECEIVE SANITARY WASTE OR SOLIDS CONTRACTOR TO COORDINATE WITH PUGET @ NEW TRANSFORMER OX POST INDICATOR VALVE SOUND ENERGY FOR CONNECTION AND INSTALLATION OF CONDUIT AND METER. SANITARY SEWER NOTES 1. ALL CONSTRUCTION/INSTALLATION OF SANITARY SEWER MAINS SHALL BE DONE IN A SAFE, NEAT AND PROFESSIONAL MANNER, AND UNDER SUPERVISION OF CITY FORCES AT ALL TIMES. ALL SAFETY REQUIREMENTS FROM OSHA AND OTHER STATE REGULATORY AGENCIES MUST BE MET. 2. THE MINIMUM SIZE FOR PUBLIC SEWER MAINS SHALL BE 8" DIAMETER. ALL SANITARY SEWER PIPING SHALL BE SCHEDULE D3034 PVC OR EQUAL. MINIMUM PIPE DIAMETER FOR PRIVATE LATERALS IS 4" AND OF SCHEDULE D3034 PVC OR EQUAL. ALL SANITARY SEWER LATERALS MUST BE PROPERLY MARKED AT ENDS. 3. CONNECTIONS INTO THE EXISTING SANITARY SEWER MAINS REQUIRE ISSUANCE OF PUBLIC WORKS PERMIT AND INSPECTION BY THE LOCAL JURISDICTION PRIOR TO BACKFILLING. ENGINEER'S RECORD 4. ALL NEW SANITARY SEWER PIPES AND MANHOLES MUST BE THOROUGHLY CLEANED, INSPECTED AND PRESSURE/VACUUM TESTED AS REQUIRED BY UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH JURISDICTION. ALL TESTS MUST BE WITNESSED AND PASSED BY THE UTILITY PROVIDER AND DRAWING CERTIFICATION GOVERNMENTAL AGENCIES WITH JURISDICTION PRIOR TO PLACING INTO OPERATION. 5. THE CONTRACTOR SHALL PROVIDE TO THE UTILITY PROVIDER ANY GUARANTEE OR WARRANTY NORMALLY FURNISHED WITH THE PURCHASE OF ANY SEE SHEET CV-1.0 FOR SIGNED ENGINEER'S MATERIALS USED IN CONNECTION WITH THE PROJECT AT HAND. RECORD DRAWING CERTIFICATION NOTE SURVEYM SCAM WRH VERTICAL NAVD 1988 DESIGNED: AS SHOWN HORIZONTAL° NAD 1983/1991 CITY OF LRR RENTON DRAWN; CMD ONE INCH DATUM • CHECKED�FF AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE AP P R APPROVED SCALE ACCORDINGLY PPI 1 • @ 11'. ►I�©lam. V ICD W Q 0 fV v LEGEND 1,2 WATER LINE w c-7.2 WATER METER ■ FIRE HYDRANT GATE VALVE FDC $ 1 THRUST BLOCK • C-7.0 DOUBLE CHECK VALVE RPBA WATER CROSSING 1,2 SIDE SANITARY SEWER C-5.1 SS MANHOLE • SS CLEANOUT TELEPHONE T T POWER (UNDERGROUND) UGP POWER (OVERHEAD) OHP GAS LINE G OIL/WATER SEPARATOR ®® IN COMPLIANCE WITH CITY OF RENTON STANDARDS W z O C/) w DATE: LL RENTON FIRESTONE 03/21/2019 17808 108TH AVE SE FIELDBOOK: z PAGE. O RECORD DRAWINGS DRAWING NO: UTILITY PLAN C-3.0 z SHEET: OF. LU 9 18 Cr R-394709 10OLF 6" SS @ 1.0% 0 -• 0 wa 90LF 6" SS © 1.0% Kel D__ UP _Up� -ST ST I ST ST ' I- "•' l�T aNd!JNCIV01 - J )IWVj ON 02 H 08 IW 56LF 6" SS @ 5. 0 X one UP P ° o " + H O6 8,261 SF I FFE 401.00 *12 ON 3 13LF 6" SS F S 14~CON © 10.0% C _) j D 10 . G X (2)18"CI yy G G G G G G G G �- r GRAPHIC SCALE 6" FIRE LINE SERVICE 1" DOMESTIC 20 0 10 20 40 80 II I I I I WATER SERVICE CONSTRUCTION KEY NOTES 1 i IN FEET ) nch = 20 ft. OA EXISTING WATER SERVICE AND METER TO BE 2 OH INSTALL SANITARY SEWER CLEANOUT. ©FIRE DEPARTMENT CONNECTION RETAINED. CONTRACTOR TO HAVE FLOW TEST PERFORMED PRIOR TO CONSTRUCTION TO ODD- COMM PEDESTAL VERIFY ADEQUATE FLOW AND PRESSURE ,CONNECT TO EXISTING TELECOM ®EXISTING IRRIGATION DOUBLE CHECK VALVE TO SERVICE. CONTRACTOR TO COORDINATE WITH BE RETAINED. ABANDON LINE PAST THIS VALVE. © CONNECT TO EXISTING WATER SERVICE, SERVICE PROVIDER FOR NEW CONNECTION. 2 COORDINATE W/SCWSD. CUT, CAP, AND REMOVE C-7.o ®FIRE HYDRANT WATER LINE PAST POINT OF CONNECTION. O LANDSCAPE IRRIGATION POINT OF CONNECTION. C SEE IRRIGATION PLANS FOR CONTINUATION. OS ROOF TO BE INSTALLED ABOVE DUMPSTER, SEE DOMESTIC WATER SERVICE POINT OF O BUILDING PLANS CONNECTION SEE MEP PLANS FOR 3 � 1,000-GALLON OIL/WATER SEPARATOR C 5.1 T CUT AND CAP EXISTING SEWER. CONTINUATION. L SANITARY SEWER POINT OF CONNECTION SEE 0 3 D AREA DRAIN, NYLOPLAST INLINE DRAIN OR C-5.o MEP PLANS FOR COORDINATION. ' Q��TSANITARY TARY SEWER MANHOLE, CONNECT TO EEQUIVALENT. SEWER STUB, CONTRACTOR TO RELOGATED POWER POLE, CONNECT OE CONNECT FIRE LINE TO EXISTING WATER MAIN. TO EXISTING ELECTRICAL. CONTRACTOR TO VERIFY EX LOCATION AND ELEVATION OF FIRE SERVICE POINT OF CONNECTION. SEE COORDINATE WITH SERVICE PROVIDER FOR NEW C 1 OV INSTALL DOUBLE CHECK DETECTOR ASSEMBLY MEP/FIRE PROTECTION PLANS FOR CONNECTION. CONTINUATION. ON INSTALL RPBA WITH HOT BOX. DIMENSIONS: 26" � TRASH ENCLOSURE DRAINAGE PIPE, NOT TO © CONNECT TO EXISTING GAS SERVICE LINE. X 10" X 22" RECEIVE SANITARY WASTE OR SOLIDS CONTRACTOR TO COORDINATE WITH PUGET @ NEW TRANSFORMER OX POST INDICATOR VALVE SOUND ENERGY FOR CONNECTION AND INSTALLATION OF CONDUIT AND METER. SANITARY SEWER NOTES 1. ALL CONSTRUCTION/INSTALLATION OF SANITARY SEWER MAINS SHALL BE DONE IN A SAFE, NEAT AND PROFESSIONAL MANNER, AND UNDER SUPERVISION OF CITY FORCES AT ALL TIMES. ALL SAFETY REQUIREMENTS FROM OSHA AND OTHER STATE REGULATORY AGENCIES MUST BE MET. 2. THE MINIMUM SIZE FOR PUBLIC SEWER MAINS SHALL BE 8" DIAMETER. ALL SANITARY SEWER PIPING SHALL BE SCHEDULE D3034 PVC OR EQUAL. MINIMUM PIPE DIAMETER FOR PRIVATE LATERALS IS 4" AND OF SCHEDULE D3034 PVC OR EQUAL. ALL SANITARY SEWER LATERALS MUST BE PROPERLY MARKED AT ENDS. 3. CONNECTIONS INTO THE EXISTING SANITARY SEWER MAINS REQUIRE ISSUANCE OF PUBLIC WORKS PERMIT AND INSPECTION BY THE LOCAL JURISDICTION PRIOR TO BACKFILLING. ENGINEER'S RECORD 4. ALL NEW SANITARY SEWER PIPES AND MANHOLES MUST BE THOROUGHLY CLEANED, INSPECTED AND PRESSURE/VACUUM TESTED AS REQUIRED BY UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH JURISDICTION. ALL TESTS MUST BE WITNESSED AND PASSED BY THE UTILITY PROVIDER AND DRAWING CERTIFICATION GOVERNMENTAL AGENCIES WITH JURISDICTION PRIOR TO PLACING INTO OPERATION. 5. THE CONTRACTOR SHALL PROVIDE TO THE UTILITY PROVIDER ANY GUARANTEE OR WARRANTY NORMALLY FURNISHED WITH THE PURCHASE OF ANY SEE SHEET CV-1.0 FOR SIGNED ENGINEER'S MATERIALS USED IN CONNECTION WITH THE PROJECT AT HAND. RECORD DRAWING CERTIFICATION NOTE SURVEYM SCAM WRH VERTICAL NAVD 1988 DESIGNED: AS SHOWN HORIZONTAL° NAD 1983/1991 CITY OF LRR RENTON DRAWN; CMD ONE INCH DATUM • CHECKED�FF AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE AP P R APPROVED SCALE ACCORDINGLY PPI 1 • @ 11'. ►I�©lam. V ICD W Q 0 fV v LEGEND 1,2 WATER LINE w c-7.2 WATER METER ■ FIRE HYDRANT GATE VALVE FDC $ 1 THRUST BLOCK • C-7.0 DOUBLE CHECK VALVE RPBA WATER CROSSING 1,2 SIDE SANITARY SEWER C-5.1 SS MANHOLE • SS CLEANOUT TELEPHONE T T POWER (UNDERGROUND) UGP POWER (OVERHEAD) OHP GAS LINE G OIL/WATER SEPARATOR ®® IN COMPLIANCE WITH CITY OF RENTON STANDARDS W z O C/) w DATE: LL RENTON FIRESTONE 03/21/2019 17808 108TH AVE SE FIELDBOOK: z PAGE. O RECORD DRAWINGS DRAWING NO: UTILITY PLAN C-3.0 z SHEET: OF. LU 9 18 Cr R-394709