HomeMy WebLinkAboutR-394710NE 1/4 OF S 321 T 23 N1 R 5 E co I W 0 0 0 N 0 IY a w t+: N J z Z Q 0 1n IY 0.l 0- o_ Y cn Of Z 0 z LIJ C z D z Q 0 0 U, 1505 Westlake Ave. N. Suite 305 z Seattle, WA 98109 Ld 018' OPENING FOR 012' NDPE.- OUTLET INVERT: 3195.60'. 3'-0' T 3'-6' 018" OPENING FOR 012HDPE,__ INLET INVERT: 395.6D'. 030' MANWAY ACCESS WITH LADDER RDA: 1:400,52'. 030" MANWAY ACCESS WITH LADDER RIM: i400.74'. 030" MNWAY ACCESS WITH LADDER RIM: ±400.62'- 030' MANWAY ACCESS WITH LADDER RIM: t4OO.53'. 192'-2%' (INCLUDES Yi GAP PER BILL OF MATERIALS TYPE QUANTITY I HEIGHT A 10 Y Al 1 3 B IS 3 B, , 3' 82 1 r C 1 3' C1 r C2 , 3' D 1 3 DI I r D2 I r 03 , r Fl I r F2 , r F3 1 3' TOTALS 3 TOP 36 4' BASE 7 030' MANWAY ACCESS 7 024, MANWAY ACCESS a LADDER 1 7 FOOT 61NCH VOLUME 0 CUBIC FEET 030' MANWAY ACCESS WITH LADDER STORM CAPTURE MODULES BY CIDCASTLE PRECAST INC- RPM: ±400.68'. INSIDE DMENSIONS: 7' W a IV L ! 3' H, SYSTEM INVERT: 395.60'. INSIDE DIMENSIONS: 7' W a 15' L a 7' H. SYSTEM INVERT: 391.60'. - - - - - - - - - 024' MANWAY ACCESS F1 B C 024' MANWAY ACCESS RIM: t401.81'_ J RIM: t40LI53% • 024' MANWAY ACCESS 024' MANWAY ACCESS RM: ±401.66'. C1 A D I RIM: *401 37' - -- - •J F. ---- ---- ---- --- --- ---- _ --- ---- --- ;� I D1 A B B B B1 B B B B C2 I •J F D2 A A A A Al A A A A F3 I r Z­ -.1;7-- --.f- __T7_ D3 B B B B 62 B B B C1, F2 I • •J OB' OPENING 030" OPENING MANWAY ACCESS WITH tADDFR 08' OPENI NG FOR 0IN PVC, FOR e6' PVC, O RIM'. t401.t0'. FOR 06' PVC. INLET INVERT; 396,60'. INLET INVERT- 396,60'. INLET INVERT 396.60'. 2'-0' 67' t' 030" MANWAY ACCESS WITH LADDER 15'-Ch' 160'-2Y' RIM: ±400,98' DESIGN NOTES: i. DESIGN LOADINGS: A. AASHTO HS-2044 W? IMPACT, B. DEPTH OF COVER = 6' - 54 (120 PCF ASSUMED), C. ASSUMED WATER TABLE = BELOW BOTTOM OF PRECAST. D. DRY LATERAL EARTH PRESSURE (EFP) = 45 PCF. E_ LATERAL LIVE LOAD SURCHARGE = 80 PSF (APPLIED TO 8' BELOW GRADE). FNO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALL PIERS, OR FOUNDATIONS. 2. CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE 6,000 PSI. 3. STEEL REINFORCEMENT. REBAR, ASTM A-615 OR A-706, GRADE 60, 4. CEMENT: ASTM C-150 SPECIFICATION. S. STORM CAPTURE MODULE TYPE = INFILTRATION. 6. DEPTH OF AGGREGATE BEARING LAYER TO BE DETERMINED BY GEOTECHNICAL ENGINEER (SEE OLDCASTLE TECH NOTE SC-01). 7. ALLOWABLE SOIL BEARING PRESSURE ADDRESSED IN OLDCASTLE TECH NOTE SC-01. 8. REFERENCE STANDARDS: A. ASTASTM C 890 B. ASTM C 691 C. ASTM C 913 9. CONSTRUCTION EQUIPMENT EXCEEDING DESIGN LOADING SHALL NOT BE ALLOWED ON STRUCTURE- ANY DESIGN CONSTRAINT DIFFERENT FROM ABOVE REQUIRES CUSTOM STRUCTURAL DESIGN AND MAY REQUIRE THICKER SUBGRADE AND REVISED PRICING, COMPACTED Ell. SEE INSTALLATION GU®E. BY OTHERS. PLAN VIEW SCALE 1716' = 1'-0' NOTE: SEVEN (7) MODULES HAVE 4' TALL SOLID BASE SECTION IB,, C1. DI-D3. FI-F2) NOTES TO REVIEWING ENGINEER: 1. THIS SYSTEM IS DESIGNED TO THE PARAMETERS NOTED. PLEASE VERIFY THAT THESE PARAMETERS MEET PROJECT REQUIREMENTS (I.E. LIVE LOAD AND FILL RANGE), IF DESIGN PARAMETERS ARE INCORRECT NOTIFY OLDCASTLE IMMEDIATELY FOR REDESIGN AND RE -PRICING. 2. REVIEWING ENGINEER TO CONFIRM ALL PIPE PENETRATION LOCATIONS, SIZES. AND INVERTS. 3. REVIEWING ENGINEER TO CONFIRM ALL MANWAY ACCESS LOCATIONS AND RIM ELEVATIONS. 4. UNLESS OTHERWISE NOTED, ALL PIPE SUPPLIED AND INSTALLED BY OTHERS. 5. THIS SYSTEM IS DESIGNED FOR A GROUNDWATER TABLE BELOW SYSTEM INVERT, REVIEWING ENGINEER TO VERIFY THAT THE DESIGN GROUNDWATER TABLE IS BELOW INVERT OF PRECAST, IF DESIGN PARAMETERS ARE INCORRECT NOTIFY OLDCASTLE C IMMEDIATELY FOR REDESIGN AND REVISED PRICING. t o r m w a t e r S. THIS SYSTEM IS DESIGNED WITHOUT A CONTAINMENT MEMBRANE LINER. IF A LINER IS NEEDED PLEASE CONTACT OLDCASTLE TO S PROVIDE THIS OPTION IN THE FINAL DESIGN. 1 al 1- al Ilr 1 1 1 ! 1 a 1 1 I I 1 I ♦;;e�♦♦�e�♦�e�e�e�♦�e�e���e�e�e�e�e�e�♦;e�♦�e�♦♦'♦�e�♦♦�e�e�ese�ee♦�e�♦�e�♦�e�°�e�♦�e�e�e�' i�ii�ii�i�iei'�i�i�i�i�i �i�i�i°e� �w•°i�i�i�i�i�i�i�i�i�i�i�i�i�iOi�i�i�i�i�iei�i�ii�i�i�i�i�i�i�i�i�i�i�i�i�i�i�s�i�i�i�i�i�i�!'i�i�i�����i�ei���i�i�i����li`i�i�i� I I I I I r r - L - - J L - - - - - - -'J -- I I I I I I I - I I IIII • - I I IIII - - _ L COMPACTED FILL GEOTEXPLE FABRIC. AGGREGATE BEARING LAYER. SEE INSTALLATION GUIDE. SEE INSTALLATION GUIDE. SEE DESIGN NOTE 6, BY CONTRACTOR. CONTRACTOR TO ENSURE ADEOUATE BEARING SURFACE BY OTHERS. PROVIDED IN ACCORDANCE WITH PROJECT SPECIFICATIONS. SEE DESIGN NOTE 7. T (206) 522-9510 F (206)522-8344 WWW. PAcLAND.COM EXTEND AGGREGATE BEARING LAYER V MINIMUM AROUND ENTIRE STORM CAPTURE PERIMETER. TYPICAL ELEVATION SCALE. 31W - V-O" STORMICAPTURE N TS NOTES 1. FOR INFILTRATION- EXFLTRATION SYSTEMS. THE AGGREGATE S➢BGRADE MUST BE WASHED AND CLEAN. 2. TER ADUCT INSERTS TO BE KNOCKED OUT AT SPECIFIED LOCATIONS ONLY, BY OTHERS Stormwater REVISION EL 395.60' 4'-0' EL 391.60' 7" EL: 391-02' SITE SPECIFIC DATA PROJECT NUMBER 4634 PROJECT NAME RENTON FIRESTONE PROJECT LOCATION RENTON, WA 57RUC77JRE ID ---- TREATMENT REQUIRED VOLUME BASED (CO FLOW BASED (CFS) 0.114 TREATMENT HGL AVAILABLE (FT) N/A PEAK BYPASS REQUIRED (CFS) - IF APPLICABLE 0.471? PIPE DATA I.E MATERIAL DIAMETER INLET PIPE 1 J96.95 DI 12" INLET PIPE 2 N/A N/A NIA OUTLET PIPE 395.452 POPE 12' PRETREATMENT BIORLTRATON DISCHARGE RIM ELEVATION 400.80 400.80 400.80 SURFACE LOAD PARKWAY OPEN PLANTER PARKWAY FRAME & COVER 36' X 36' N/A NIA WETLANDMEDM VOLUME (CY) 2.73 WETLANDMEDIA DELIVERY METHOD PER CONTRACT ORIFICE $IZE (DIA. INCHES} 01.55" NOTES' PRELIMINARY, NOT FOR CON57RUCRON_ INSTALLATION NOTES 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT, MATERIALS AND INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS SPECIFICATIONS, UNLESS OFHERWISE STATED IN MANUFACTURERS CONTRACT 2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER RECOMMENDS A MINIMUM 6` LEVEL ROCK BASE UNLESS SPECIFIED BY THE PROJECT ENGINEE✓? CONTRACTOR IS RESPONSIBLE TO VERIFY PROJECT ENGINEERS RECOMMENDED BASE SPECIRCA77ONS. J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR ALL GAPS AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON-SHR)NK GROUT PEI? MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL MEET OR EXCEED REGIONAL PIPE" CONNECTION STANDARDS. 4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES- 5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS, MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 6. DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION. 7, CONTRACTOR RESPONSIBLE FOR CONTACTING MODULAR WETLANDS FOR ACTIVATION OF UNIT MANUFACTURES WARRANTY IS VOID WITH OUT PROPER ACTIVATION BY A MODULAR WETLANDS REPRESENTATIVE. GENERAL NOTES I. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED, 2. ALL DIMENSIONS, ELEVATIONS SPECIFICATIONS AND CAPACITTS ARE SU9JECT TO CHANGE FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT MANUFACTURER. n SURVEYED: WRH DESIGNED: LRR DRAWN: CMD CHECKED: WFF BY DATE APPR APPROVED: BED C/L SITE CURBING BY OTHERS VERTICAL UNDERDR4IN PATENTED MANIFOLD PERIMETER,.,. _ i u01D AREA _ _ - _w DRAIN DOWN LINE PRE -FILTER - - aS£E N07E5 % 103 CARTRIDGE r rn ^ FLOW CONTROL RISER FT u T T INLET PIPE SEE NOTES I PLAN VIEW CIL I �iC1CC"�ifi] IE IN 4 I 4.-4 -I 4„ ELEVATION VIEW Rire.L►_�w:����,�•�3�www �+ �•��r1:� THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE ASSESSED TO ENSURE NO UPSTREAM FLOODfNG. PEAK HGL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. LEFT END VIEW RIGHT END VIEW JNPA D� : AR TL!-' NDS .� �eeaxr:araxa.aa-^ :eea: a.:aa �•' MODULAR STORMWATER VAULT N TS CTODLA(`ADTI IDC' IIAIIT IL 11UILCI rlrC IV r-A STORM DRAINAGE SYSTEM 112N SD SEE DETAIL 1/C-6.0 MODULAR WETLAND SYSTEM SEE DETAIL 2/C-6.0 1' AGGREGATE LAYER TREATMENT -DETENTION -CONTROL STRUCTURE PROFILE (SCHEMATIC) SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M N TS ENGINEER'S RECORD DRAWING CERTIFICATION SEE SHEET CV-1.0 FOR SIGNED ENGINEER'S RECORD DRAWING CERTIFICATION NOTE CITY OF RENTON Planning/Building/Public Works Dept. NOTES: 1. DETAIL IS SCHEMATIC IN NATURE, AND IS PROVIDED FOR REFERENCE ONLY. REFER TO SHEET C-2.0 FOR RIM AND INVERT ELVATIONS IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON FIRESTONE 17808 108TH AVE SE RECORD DRAWINGS DRAINAGE DETAILS U /N 0M0 co 0 C) T w z O I- Cn W DATE: LL 02/21/2019 FIELDBOOK: z PAGE: O DRAWING NO: C-6.0 z I SHEET: OF, W 10 18 Er R-39471 0