HomeMy WebLinkAboutR-394712NE 1/4 OF S 321 T 23 N1 R 5 E
co
I
W
0
0
0
N
0
a.
a
o:
w
N
J
1n
W
a
a
Y
0.
z
0
z
w
z D
C
z Q
0
Z
3
N 1505 Westlake Ave. N.
Lij
Suite 305
W Seattle, WA 98109
BOLT -Dawn HOLI=(TVP.)
- s)a" - 11 NC, SEE
DETAIL & NOTE 2
TOP
SECTION
RED ESSED ALLEN
HEAD CAP SCREW
519"-11 NCx2`
NOTES
T. This Frame Is designed to accommodate 20" = 24' grates or
Covers
2. Provide two holes In the frame that are vertically aligned with t
he grate or cover slats. Tap each hole to accept
a SiB" - 11 NC x 2" alien (lead cap screw.
Location of bolt down holes varies among different
manufacturers.
3. Refer to Standard Specification 9-05.15(2) for additional
requirements.
j5W
GFL%TrISOMETRIC VIEW
FRPME
'v
2 1JZ"
SECTION
BOLT -DOWN DETAIL
DETAILHoit1
PUSUC WORKS RECTANGULAR FRAME STD. FLAN — 04.00
DEPARTMENT
- MARCH 2008
T (206) 522-9510
F (206)522-8344
WWW. PAcLAND.COM
RECTANGULAR FRAME
N TS
24'
M
m
BOLT -DOWN SLf
DETAIL AND NO'
2 il2' DIA WtE
20'
A
6
TOP
41 s' 1 1f2
I r
T_ M*tltmw
39-R -SEE NOTE
SECTION
5.r6`
I' DIAM. HOLE
!' DIA M. HANDLE
SECTION
PUBLIC WORKS
` DEPARTMENT
REVISION
112'
3M'
7 14,
BOLT -DOWN BLOT DETAIL.
SEE M07E 1
2
SECTION
NOTES
1. Provide Iwo slats In the cover that are vertically aligned
with the holes In the frame.Laeatlon of bolt -down slots
vales among different manufacturers.
2. Alternative reinforcing deslgrts are acceptable In
lieu of the db design.
3. Refer to Standard Speclflcatlon 9.05.15(2) for additional
requirements
d. For Frame detalls. See City of Renton
Standard Plan 204-00.
RECTANGULAR SOLID
METAL COVER
180METNC
STD. PLAN — 2D4.10
MARCH 2O08
RECTANGULAR SOLID METAL COVER
N TS
SURVEYED:
WRH
DESIGNED:
LRR
DRAWN:
CMD
CHECKED:
WFF
BY DATE I APPR APPROVED:
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
C� J
TOP
NOTES
1. Provide Iwo slots in the grate that are vertically aligned with the holes in the frame.
Location Of Galt -dawn slots varies among different manufacturers.
2. Refer to Standard SpedAcation 9-05.15(2) for additional requirements.
a. The thickness of the grate Shall not exceed 1 W!8".
a. Unless otherwise specified, vaned grates steal be used with standard frame
In the travel way. gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
ISOMETRIC
%OT - St; E 4ET.°JL
AND NOTE t
316' (9mm) RECI`SSED
LI=TTERIFIG
3!4'
Ll
BOLT DOWN SLOT DETAIL
SEE NOTE I
- STD. PLAN — 204.40
PUBLIC WORKS RECTANGULAR
DEPARTMENT HERRINGBONE GRATE
- MARCH 2O08
RECTANGULAR HERRINGBONE GRATE
ENGINEER'S RECORD
DRAWING CERTIFICATION
SEE SHEET CV-1.0 FOR SIGNED ENGINEER'S
RECORD DRAWING CERTIFICATION NOTE
CITY OF
RENTON
Planning/Building/Public Works Dept.
NTS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
RENTON FIRESTONE
17808 108TH AVE SE
RECORD DRAWINGS
DRAINAGE DETAILS
U
N
0�0
O
O
O
J
W
Z
O
I—
W
DATE:
02/21 /2019 ILL
�D
PAGE:
O
DRAWING NO: L_
C-6.2 Z
SHEET: OF: W
12 18
R-394712