HomeMy WebLinkAboutBid Plans - HR Tenant ImprovementsBID ALTERNATESALTERNATE NO. 1 -HVAC AND CEILING BASE BID: NO IMPACT TO HVAC, REPLACE CEILING TILE ONLY. ALTERNATE: PERFORM HVAC UPDATES PER MECHANICAL DRAWINGS, REMOVE AND REPLACE CEILING GRID AND TILE. ALTERNATE NO. 2 -LIGHTING BASE BID: NO UPDATES TO EXISTING LIGHTING EXCEPT AS REQUIRED BY NEW CONSTRUCTION. ALTERNATE: REMOVE AND REPLACE ALL LIGHTING FIXTURES WITH NEW LED FIXTURES PER ELECTRICAL DRAWINGS. BID ALTERNATES SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:10 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt 1/8" = 1'-0" G0.01 TITLE SHEET AND DRAWING INDEX N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET ARCHITECTURAL DRAWINGS A0.01 ADA AND TYPICAL INTERIOR DETAILS A0.02 PARTITION TYPES AND DETAILS A1.01 SEVENTH FLOOR DEMOLITION PLAN A1.02 SEVENTH FLOOR DEMO REFLECTED CEILING PLAN A1.10 SEVENTH FLOOR PLAN A1.11 SEVENTH FLOOR FINISH PLAN A1.20 SEVENTH FLOOR REFLECTED CEILING PLAN A4.10 ENLARGED PLANS, INTERIOR ELEVATIONS & DETAILS A6.10 DOOR SCHEDULE, DOOR DETAILS DRAWING INDEX G0.01 TITLE SHEET AND DRAWING INDEX G0.02 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS G1.10 CODE ANALYSIS SITE MAP NOT TO SCALE VICINTY MAP NOT TO SCALE SITE INFORMATION LEGAL DESCRIPTION:PORTION OF GOV LOT 10 IN SW 1/4 OF SECTION 17-23- 05 AND OF BLOCK 17 OF TOWN OF RENTON -BEGIN C/L OF INTERSECTION OF SOUTH 5TH STREET AND MAIN AVE SOUTH TH S 00-46-18 W 327.80 FT TH S 00-45-13 W 663.94 FT TH S 89-18-37 W 30.01 FT TH N 00-45-13 E 53.02 FT TAP ON N LINE OF S 53 FT, MEASURED AT R/A TO S LINE OF GOV LOT 10 AND POB TH S 89-18-37 W 230.63 FT TH N 00-46-08 E 95.14 FT TO NWLY CORNER OF TRACT CONVEYED TO MIKE RUKLIC AUDITOR FILE NO 568802 TH S 89-18-37 W 57 FT TH N 00-46-08 E 148.79 FT TAP ON SELY MARGIN OF SOUTH GRADY WAY TH N 45-40-13 E 193.72 FT ALONG SAID SELY MARGIN TO POINT OF CURVATURE TH CONTINUING ALONG SAID SELY MARGIN NLY 264.78 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 756.20 FT RADIUS POINT BEARING N 44-19-16 W THRU C/A OF 20-03-40 TAP OF INTERSECTION WITH WLY MARGIN OF SAID MAIN AVENUE SOUTH TH S 00-45-13 W 589.92 FT TO POB LESS PORTION FOR CO ROAD UNDER RECORDING NO 8709020544 ADDRESS:1055 S GRADY WAY RENTON, WA 98057 CLIENT CITY OF RENTON 1055 S GRADY WAY, SUITE 610 RENTON, WA 98057 CONTACT:RUSS WOODRUFF, CAPITAL PROJECT COORDINATOR PHONE: 206.556.5026 EMAIL: rwoodruff@rentonwa.gov ARCHITECTURAL MACKENZIE LOGAN BUILDING 500 UNION ST #410 SEATTLE, WA 98101 CONTACTS:KIM DOYLE, PROJECT MANAGER PHONE: 206.749.9993 EMAIL: kdoyle@mcknze.com BRETT HANSON, ARCHITECT PHONE: 206.749.9993 EMAIL: bhanson@mcknze.com DRAWING CRITERIA ALL DRAWINGS ARE IDENTIFIED BY TWO DIGITS AS FOLLOWS: A.CATEGORY LETTER REFERRING TO THE DISCIPLINE OR MAJOR DIVISION. G.TITLE SHEET AND CODE INFORMATION A.ARCHITECTURAL M.MECHANICAL E.ELECTRICAL DEFERRED SUBMITTALS PER SECTION 107.3.4.1 DEFERRED SUBMITTALS: DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. • FIRE SPRINKLER NFPA 13 SYSTEM • FIRE ALARM SYSTEM • CARBON MONOXIDE DETECTION SYSTEM • PROVIDE CALCULATIONS AND DETAILS FOR SEISMIC ANCHORAGE AND BRACING OF ALL MECHANICAL AND ELECTRICAL AND OTHER EQUIPMENT WEIGHING MORE THAN 400LBS AND ATTACHED TO A FLOOR OR ROOF LEVEL, OR WEIGHING MORE THAN 75LBS AND ATTACHED MORE THAN 4'-0" ABOVE THE FLOOR OR ROOF LEVEL. PROJECT LOCATION I-405 PROJECT LOCATION 518 I-5 I-5 I-405 I-405 167 S G R A D Y W A Y TALBOT RD SBENSON RD S108TH AVES 7TH ST S 6TH ST SMITHERS AVE SMORRIS AVE SS G R A D Y W A Y S RENTON VILLAGE PL MECHANICAL BCE ENGINEERS 6021 12TH ST E #200 FIFE, WA 98424 CONTACT:CHRIS CAFFEE, PRINCIPAL PHONE: 253.922.0446 EMAIL: chris.caffee@bceengineers.com ELECTRICAL BCE ENGINEERS 6021 12TH ST E #200 FIFE, WA 98424 CONTACT:BEN HEDIN, PRINCIPAL PHONE: 253.922.0446 EMAIL: ben.hedin@bceengineers.com MECHANICAL DRAWINGS M0.01 MECHANICAL LEGEND & NOTES MD1.01 SEVENTH FLOOR MECHANICAL DEMOLITION PLAN MD1.11 SEVENTH FLOOR MECHANICAL DEMOLITION RCP M1.01 SEVENTH FLOOR PLUMBING PLAN M2.01 SEVENTH FLOOR MECHANICAL PLAN M2.11 SEVENTH FLOOR MECHANICAL REFLECTED CEILING PLAN M5.01 MECHANICAL DETAILS M6.01 MECHANICAL SCHEDULES M7.01 MECHANICAL CONTROLS ELECTRICAL DRAWINGS E0.01 ELECTRICAL LEGEND E0.02 ELECTRICAL GENERAL NOTES E0.03 ELECTRICAL GENERAL NOTES ED2.10 SEVENTH FLOOR LIGHTING DEMO PLAN ED3.10 SEVENTH FLOOR POWER DEMO PLAN ED4.10 SEVENTH FLOOR SYSTEMS DEMO PLAN E2.10 SEVENTH FLOOR LIGHTING PLAN E3.10 SEVENTH FLOOR POWER PLAN E4.10 SEVENTH FLOOR SYSTEMS PLAN E6.01 ONE-LINE DIAGRAM E6.11 PANEL SCHEDULES I E6.12 PANEL SCHEDULES II E6.21 LIGHTING FIXTURE SCHEDULE AND CONTROLS E7.11 SYSTEMS DETAILS E7.12 SYSTEMS DETAILS RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT PERMIT | BID SET 01/03/2023 Revision Schedule Revision Delta Issue Date 0GRIDLINE DETAIL REFERENCE MARK A101 1 SIM DETAIL # CATEGORY SUB-CATEGORY SHEET # OPT. NOTE KEYNOTE DIVISION # NOTE # 1 REVISION # REVISION MARK REVISION CLOUD SYMBOLS AND REFERENCES TRUE NORTH PROJECT NORTH NORTH ARROW 00-01 INTERIOR ELEVATION KEY MARK A4.10 1 DETAIL # SHEET # FILLED ARROW ANNOTATION SYMBOLS ROOM NAME 101 SPACE # SPACE NAME ROOM/SPACE IDENTIFICATION 101DOOR NUMBER SYMBOL AWINDOW TYPE SYMBOL A. OVERALL FLOOR PLANS ARE INTENDED TO IDENTIFY ENTIRE FLOOR AREA. REFER TO INDIVIDUAL AREA PLANS FOR SPECIFIC DIMENSIONS, DETAILING, PARTITION TYPES, AND ADDITIONAL INFORMATION. B. ALL WALLS ARE FULL HEIGHT TO STRUCTURE OR UNDERSIDE OF FLOOR DECK ABOVE UNLESS NOTED OTHERWISE. C. WHERE TOP OF WALL MEETS UNDERSIDE OF FLOOR DECKING, PROVIDE DEFLECTION HEAD AS REQUIRED. D. REFERENCE DOOR SCHEDULE FOR DOOR TYPE DESIGNATION AND ADDITIONAL INFORMATION. E. REFER TO CODE ANALYSIS PLANS FOR FIRE EXTINGUISHER LOCATIONS. F. FURNITURE AND EQUIPMENT BY OTHERS, SHOWN FOR REFERENCE ONLY. G. CONTRACTOR TO COORDINATE WALL MOUNTED FURNITURE, INCLUDING BUT NOT LIMITED TO, CABINETRY, PROJECTION SCREENS, WHITE BOARDS, TELEVISIONS, ETC. AND PROVIDE NECESSARY BLOCKING AS REQUIRED. H. CONTRACTOR SHALL COORDINATE DELIVERY AND INSTALLATION OF OWNER FURNISHED EQUIPMENT WITH THE OWNER. I. WALL THICKNESSES ARE NOMINAL UNLESS OTHERWISE NOTED. J. DIMENSIONS MARKED “CLR”ARE FROM FINISH SURFACE TO FINISH SURFACE. DIMENSIONS WITH THIS MARK TAKE PRIORITY OVER ADJACENT DIMENSIONS. DIMENSIONS ADJACENT TO LATCH SIDE OF DOORS INDICATE REQUIRED CLEARANCES BETWEEN CLEAR DOOR OPENING AND ADJACENT FINISH. K. ALL DIMENSIONS SHOWN AS PLUS/MINUS (+/-) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. L. DOORS NOT DIMENSIONED ARE TO BE LOCATED [4”] FROM FACE OF WALL TO OUTSIDE EDGE OF JAMB. M. COORDINATE AND REFER TO MECHANICAL AND ELECTRICAL SPECIFICATIONS FOR SPECIFIC INFORMATION AND CONNECTIONS. N. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. O. ALL RATED CONSTRUCTION ASSEMBLIES EXTEND FROM FLOOR STRUCTURE TO UNDERSIDE OF STRUCTURE AND DECKING ABOVE UNLESS OTHERWISE NOTED. P. PROVIDE TYPE 'X' GYPSUM BOARD AT ALL FIRE RATED WALLS AND PARTITIONS. REFER TO CODE SUMMARY DRAWINGS AND FLOOR PLANS FOR SCOPE OF FIRE RATED WALLS. Q. ALL PENETRATIONS AND VOIDS THROUGH FIRE-RATED ASSEMBLIES TO BE FIRE STOPPED WITH APPROVED MATERIALS. R. PROVIDE FIRE BLOCKING AS REQUIRED. S. PATCH AND REPAIR EXISTING CONDITIONS DAMAGED BY NEW WORK TO NEW CONDITION. T. ALL EXISTING BUILDING ELEMENTS TO REMAIN UNLESS NOTED OTHERWISE. U. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING. V. CAP ALL ABANDONED PLUMBING, ELECTRICAL CONDUIT, AND OTHER UNDER SLAB UTILITIES AS REQUIRED. W. DO NOT OVERCUT CORNERS AT NEW WALL PANEL/FLOOR SLAB OPENINGS. X. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO OWNER FOR FUTURE USE. PROVIDE DISPOSAL OF UNWANTED ITEMS. Y. REMOVE EXISTING FLOORING AT AREAS WHERE NEW FINISHES ARE NOTED --REFER TO 1/A1.11. PATCH, REPAIR AND PREP SUBSTRATE AS REQUIRED TO RECEIVE NEW FINISHES. Z. RETAIN EXISTING FIRE EXTINGUISHERS FOR FUTURE USE. AA. AT AREAS RECEIVING NEW INTERIOR DRYWALL, PROVIDE SPEC REQUIRED DRYWALL FINISH TO EXTENT OF WALL SURFACE IN SAME PLANE. WHERE REPAINTING ENTIRE ROOMS, PREP ENTIRE WALL SURFACES TO RECEIVE NEW PAINT TO STANDARD INDICATED IN SPECIFICATIONS. ARCHITECTURAL GENERAL NOTES A. THE DRAWINGS LOCATE PRODUCTS, SURFACES, AND MATERIALS AND THE NOTES CONVEY DESIGN INTENT. THE PROJECT INTENT IS TO PROVIDE FOR A COMPLETE, WORKING SYSTEM. B. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE EDITION, AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES. C. VERIFY AND CONFIRM ALL CONDITIONS, DIMENSIONS, AND LAYOUT INFORMATION PRIOR TO START OF CONSTRUCTION. NOTIFY MACKENZIE OF ANY DISCREPANCIES PRIOR TO START OF WORK. ANY CORRECTION WORK REQUIRED AS A RESULT OF NOT REPORTING SUCH DISCREPANCIES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. D. CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY EXAMINE THE SITE AND THE CONSTRUCTION DOCUMENTS OF THE ENTIRE WORK. INCONSISTENCIES IN THE PLANS OR SPECIFICATIONS SHALL BE CALLED TO THE ATTENTION OF MACKENZIE. E. REFER TO ENLARGED PLANS AND ELEVATIONS WHERE INDICATED FOR ADDITIONAL INFORMATION. ENLARGED PLANS TAKE PRECEDENCE OVER PLANS OF SMALLER SCALE, AND DETAILS TAKE PRECEDENCE OVER PLANS. IN THE CASE OF A CONFLICT, THE HIGHEST COST OPTION SHOULD BE PRICED. F. DETAIL REFERENCES SHALL BE APPLIED TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR, UNLESS NOTED OTHERWISE. G. THE TERMS “ABOVE FINISH FLOOR”(AFF) AND “FINISH FLOOR ELEVATION”(FFE) REFER TO FINAL FINISHED FLOOR ELEVATION, WHETHER BUILT-UP SLAB, COMPOSITE DECK, OR RAISED ACCESS FLOOR. H. DO NOT SCALE DRAWINGS. I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. J. SAVE AND RECYCLE DEMOLITION DEBRIS AS APPLICABLE. ALL DEMOLISHED OR REMOVED EXISTING MATERIAL SHALL BE LEGALLY DISPOSED. COORDINATE WITH THE CITY OF RENTON'S REQUIREMENTS FOR RECYCLING/RE-USE OF DEMOLITION DEBRIS. K. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK. THE CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY MATERIALS, BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT, INCLUDING THE INSIDE OF ALL WINDOWS AS NECESSARY SO THAT THE SPACE IS READY FOR OCCUPANCY BY TENANT. L. ALL DESIGN-BUILD ITEMS, SYSTEMS, AND ELEMENTS ARE TO BE SUBMITTED FOR REVIEW AND APPROVED BY MACKENZIE. M. EXISTING MATERIAL NOTED TO BE RETURNED TO THE OWNER SHALL BE SAFELY STORED AND PROTECTED UNTIL IT IS REMOVED FROM THE SITE BY THE OWNER PROJECT GENERAL NOTES SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:12 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated G0.02 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET UNO / UON UNLESS NOTED OTHERWISE USG UNITED STATES GYPSUM VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VFY VERIFY VIF VERIFY IN FIELD VP VISION PANEL W/ WITH W/CRC COATING WITH CHEMICAL RESISTANCE W/O WITHOUT WB WOOD BASE WC WATER CLOSET / WALL COVERING WD WOOD WF WIDE FLANGE BEAM WH WATER HEATER WP WATER PROOF / WOOD PANELING / WORK POINT WR WATER RESISTANT WRGB WATER RESISTANT GYPSUM BOARD WS WATER STOP / WELDED STUD WWF WELDED WIRE FABRIC WWR WELDED WIRE MESH NIC NOT IN CONTRACT NO. / # NUMBER NOM NOMINAL NR NON RATED NS NEAR SIDE NTE NOT TO EXCEED NTS NOT TO SCALE O/A OVERALL OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OH OPPOSITE HAND OHD OVERHEAD DOOR OPNG OPENING OPP OPPOSITE OSF / O/FACE OUTSIDE FACE OSSC OREGON STRUCTURAL SPECIALTY CODE OTS OPEN TO STRUCTURE P PAINT P-LAM PLASTIC LAMINATE P.E. PROFFESSIONAL ENGINEER PB PARTICLE BOARD PDA / PAF POWDER DRIVEN ANCHORS/POWDER ACTUATED FASTENER PJ PANEL JOINT PL / PLATE PLB PARALLAM BEAM PLMB PLUMBING PLY / PLYWD PLYWOOD PNL PANEL PR PAIR PS POUR STRIP PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED / PORCELAIN TILE PVC POLY VINYL CHLORIDE PVMT PAVEMENT R RADIUS RAD RADIUL RB RUBBER BASE RBE ROOF BASE ELEVATION RCP REFLECTED CEILING PLAN RD ROOF DRAIN RECEPT RECEPTION(IST) REF REFERENCE / REFRIGERATOR REINF REINFORCING REQ / REQ'D REQUIRED REV REVISION RM ROOM RO ROUGH OPENING ROW RIGHT OF WAY S STAIN SAT SUSPENDED ACOUSTICAL TILE SC SEALED CONCRETE / SOLID CORE WOOD SCHED SCHEDULE SCM STRUCTURAL CLAY MASONRY SF STORE FRONT / SQUARE FEET SFRS SEISMIC FORCE RESISTING SYSTEM SHTG / SHT'G SHEATHING SIM SIMILAR SLRS SEISMIC LOAD RESISTIVE SYSTEM SLV SHORT LEG VERTICAL SMS SHEET METAL SCREW SOG SLAB ON GRADE SP SPACE(D)(S) SPEC(S) SPECIFICATION(S) SQ SQUARE SS STAINLESS STEEL / SOLID SURFACE ST STONE STA PT STATION POINT STAGG STAGGERED STD STANDARD STIFF STIFFENER STL STEEL STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL T TEMPERED T&B TOP AND BOTTOM T/ TOP OF TC TOP OF CURB TEMP TEMPERATURE / TEMPORARY THK THICK / THICKNESS TL TOTAL LOAD TN TOE NAIL TO TOP OF TOF TOP OF FOOTING TOS TOP OF STEEL TOW TOP OF WALL TPO THERMOPLASTIC POLYOLEFIN TRANS / TRANSV TRANSVERSE TS TUBE STEEL TYP TYPICAL U/S UNDERSIDE UC UNDER COUNTER UL UNDER WRITERS LABORATORIES FF FACTORY FINISH / FINISHED FACE FFE FINISH FLOOR ELEVATION FIN FINISH(ED) FL FLUSH FLR FLOOR FM FACTORY MUTUAL FN FIELD NAILING FND FOUNDATION FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISH BY OWNER INSTALL BY CONTRACTOR FOM FACE OF MASONRY FOS FACE OF STUD FOW FACE OF WALL FS FAR SIDE FT FEET/FOOT FIRE TREATED FTG FOOTING GA GAUGE GALV GALVANIZED GEN GENERAL GLB GLULAM BEAM GLZ GLAZING GR GRADE GRD GRID ONLY GSA U.S. GENERAL SERVICES ADMINISTRATION GYP BD GYPSUM BOARD HB HOSE BIB HC HOLLOW CORE / HANDICAP HCM HOLLOW CLAY MASONRY HDPE HIGH DENSITY POLYETHELENE HDR HEADER HDWR HARDWARE HGR HANGER HL HALF LITE HM HOLLOW METAL HMK HOLLOW METAL KNOCKDOWN HMW HOLLOW METAL WELDED HORIZ HORIZONTAL HR(S) HOUR(S) HS HEADED STUD HSB HIGH STRENGTH BOLT HSS HOLLOW STRUCTURAL STEEL HTG HEATING HVAC HEATING, VENTILATION AND AIR CONDITIONING HWS HEADED WELD STUD IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IE INVERT ELEVATION IF INSIDE FACE IFC INTERNATIONAL FIRE CODE IMC INTERNATIONAL MECHANCIAL CODE INFO INFORMATION INSP INSPECTION / INSPECTOR INSUL INSULATION INT INTERIOR IPC INTERNATIONAL PLUMBING CODE JNT JOINT JST JOIST K KIPS KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH L ANGLE LAM LAMINATE LAV LAVATORY LB LAG BOLT LL LIVE LOAD LLV LONG LEG VERTICAL LONG / LONGIT LONGITUDINAL LP LOWPOINT LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER LWC LIGHTWEIGHT CONCRETE M MIRROR M/E/P MECHANICAL/ ELECTRICAL/ PLUMBING OR PROCESS MANF MANUFACTURER MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MDF/MDO MEDIUM DENSITY FIBERBOARD / OVERLAY MECH MECHANICAL MFD MANUFACTURED MFG MANUFACTURING MFR MANUFACTURER MGR MANAGER MH MAN HOLE MIN MINIMUM MISC MISCELLANEOUS MK MARK MLP METAL LINEAR PANEL MO MASONRY OPENING MOD BIT MODIFIED BITUMINOUS MP METAL PANEL MTL METAL (N) NEW NFPA NATIONAL FIRE PROTECTION AGENCY @ AT AB ANCHOR BOLT AC ASPHALTIC CONCRETE ACI AMERICAN CONCRETE INSTITUTE ADA AMERICANS WITH DISIBILITIES ACT ADD'L ADDITIONAL ADJ ADJACENT/ ADJUSTABLE AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AFF ABOVE FINISH FLOOR AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AL / ALUM ALUMINUM ALT ALTERNATE APPROX APPROXIMATE ARCH ARCHITECT(URAL) ATR ALL-THREAD ROD B/ BOTTOM OF BATT BATTEN INSULATION BD BOARD BLD / BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BENCHMARK / BEAM BN BOUNDARY NAIL BOT / BOTT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN BUR BUILT UP ROOFING CAB CABINET CB CATCH BASIN CDF CONTROLLED DENSITY FILL CIP CAST IRON CJ CONTROL JOINT CL / CENTERLINE CLNG CEILING CLR CLEAR CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CNTR CENTER CO CLEAN OUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR COORD COORDINATE CORR CORRUGAT(ED) (lON) CPT CARPET CRC CHEMICAL RESISTANT COATING CSK COUNTERSINK CSP CONCRETE SEWER PIPE CTOP COUNTERTOP CTR / CNTR CENTER CW CONCRETE WALL d PENNY(NAILS) DBA DEFORMED BAR ANCHOR DBL DOUBLE DC DEMAND CRITICAL WELD DET / DTL DETAIL DET/DTL DETAIL DF DRINKING FOUNTAIN / DOUGLAS FIR DIA / ø DIAMETER DIAPH DIAPHRAGM DIM DIMENSION DL DEAD LOAD DN DOWN DP DEEP DR DOOR DS DOWN SPOUT DWG DRAWING DWLS DOWELS (E) / EXIST EXISTING E/ EDGE OF EA EACH EF EACH FACE EIFS EXTERIOR INSULATION FINISH SYSTEM ELECT ELECTRICAL ELEV ELEVATION EN EDGE NAIL ENGR ENGINEER EOP EDGE OF PANEL EP EPOXY PAINT / EDGE OF PAVEMENT EPDM ETHYLENE PROPYLENE DIENE MONOMER EQ EQUAL ES EACH SIDE ETC EPOXY TRAFFIC COATING / ETCETERA EW EACH WAY EXP EXPOSED STRUCTURE EXP JT / EJ EXPANSION JOINT EXT EXTERIOR F/ FACE OF F/STUD FACE OF STUD FB FLAT BAR FC FACE OF CURB FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FE FIRE EXTINGUISHER STANDARD ABBREVIATIONS Revision Schedule Revision Delta Issue Date UP DN GENERAL INFORMATION CODE COMPLIANCE SUMMARY BUILDING OWNER: CITY OF RENTON PROJECT ADDRESS:1055 S. GRADY WAY RENTON, WASHINGTON PARCEL: # 172305-9023 ZONE:CO -COMMERCIAL OFFICE AREA OF TENANT SPACE:7TH FLOOR -15,732 U.S.F. AREA OF WORK +/-3,378 SF MAX. HEIGHT (ZONING)60 FEET MAXIMUM BUILDING NARRATIVE TENANT IMPROVEMENT TO PART OF THE SEVENTH FLOOR FOR OFFICE USE TO INLCUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, LIGHTING, POWER & COMMUNICATIONS, PAINT AND OTHER FINISHES. THERE IS NO CORE OR SHELL WORK BEING DONE. APPLICABLE BUILDING REGULATIONS 2018 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2018 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON STATE AMENDMENTS 2018 UNIFORM PLUMBING CODE W/ WASHINGTON STATE AMENDMENTS 2020 NATIONAL ELECTRICAL CODE W/ WASHINGTON STATE AMENDMENTS 2018 INTERNATIONAL EXISTING BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2018 INTERNATIONAL ENERGY CONSERVATION CODE W/ WASHINGTON STATE AMENDMENTS BUILDING DATA CONSTRUCTION TYPE (Table 601):TYPE 1 -1-HOUR CONSTRUCTION FIRE PROTECTION (903.2.9):FULLY SPRINKLERED OCCUPANCY CLASSIFICATIONS:B-OFFICE FIRE RESISTANCE RATING -601 PRIMARY STRUCTURAL FRAME 3-HOUR NONBEARING WALLS AND PARTITIONS -INT.NR FLOOR CONSTRUCTION 2-HOUR OCCUPANCY SEPARATIONS (TABLE 508.4)N/A ACCESSORY OCCUPANCY (508.1)AGGREGATE -10% MAX. SPACES WITH ONE EXIT (TABLE 1006.2.1)B-OCC. 49 MAX. EXIT CONFIGURATION (1007.1.1-EX. 2)1/3 MAX. DIAGONAL DIMENSION (FULLY SPRINKLERED) CORRIDOR REQUIREMENTS (Table 1020.1)NR -FULLY SPRINKLERED (B/A-OCC.) COMMON PATH OF TRAVEL DIST. (Table 1006.2.1)B (SPRINKLERED) = 100 FEET EXIT TRAVEL DISTANCE (Table 1017.2)B (SPRINKLERED) = 250 FEET DEAD END CORRIDORS (1020.4 -EX.2)B (SPRINKLERED) = 50 FEET SPACE AREA OCCUPANCY LOAD FAC. OCC. REQ. EXITS PROV. EXITS OFFICES 2,968 B 150 20 - - BREAK 236 B 15 16 - - CONFERENCE 174 B 15 12 - - TOTAL: 3,378 B VARIES 49 1 1 OCCUPANCY -301 GENERAL CODE DATA FIRE EXTINGUISHER PRIMARY EXIT B OCCUPANCY NEW WALL 16 NUMBER OF OCCUPANTS SERVED BY AN EGRESS EXIT SIGN LEGEND START PATH OF EGRESS TOTAL PATH OF EGRESS DISTANCE (INCLUDES COMMON PATH) ROOM/AREA NAME OCCUPANCY AREA TYPE ROOM AREA (SF) OCCUPANCY LOAD FACTOR ROOM OCCUPANCY COUNT TOTAL COMMON PATH OF EGRESS DISTANCE COMMMON PATH OF EGRESS DIRECTION OF EGRESS END COMMON PATH OF EGRESS EXISTING WALL X' - X"X' - X" EXISTING FIRE EXTINGUISHER ROOM B ## # 236 BREAK ROOM B 16 15 74 SECURE FILES B 1 150 174 CONFERENCE B 12 15 125 OFFICE B 1 150 210 OFFICE B 2 150 147 OFFICE B 1 150 156 OFFICE B 2 150 2028 OPEN OFFICE B 14 150 EXISTING STAIR EXISTING ELEVATORS EXISTING RESTROOMS EXISTING STAIR GRAY = NIC GRAY = NIC 81' -11" 83' -11" 236' -8" 1/3 DIAGONAL DISTANCE = 81' - 4" 243' - 11" 37 12 SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:15 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated G1.10 CODE ANALYSIS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET 3/32" = 1'-0"G1.10 1 SEVENTH FLOOR LIFE SAFETY PLAN Revision Schedule Revision Delta Issue Date MIN60"MIN 18"MIN48"12" MIN IF BOTH LATCH AND CLOSER FRONT APPROACH B: 54" MINA: 60" MINB: 42" MIN A: 36" MIN 42" MIN12" MIN IF BOTH LATCH AND CLOSER HINGE SIDE APPROACH 48" MINMIN 24"42" MIN24" MIN LATCH SIDE APPROACH 22"48" IF BOTH LATCH AND CLOSER54" IF CLOSER PROVIDED48" IF CLOSER PROVIDEDPLAN ELEVATION 48" TO HANDLE2'-0" MIN FIRE EXTINGUISHER CABINET SEE ABOVE NOTE: COORDINATE LOCATION OF CABINET WITH A/E TO ENSURE NO CONFLICTS WITH DOOR SWINGS. SOUND CONTROL INSULATION AS OCCURS METAL STUDS FIRE EXTINGUISHER CABINET AED CABINET SEE ABOVE AED CABINET 6" MIN 16" 12" 6" ACCESSORY ABBREVIATIONS LEGEND GENERAL NOTES: ACCESSORIES PTD A HEIGHT OF OPERABLE PARTS MUST BE LOCATED WHOLLY BELOW, TYP PAPER TOWEL DISPENSERPTD 1. ALL STAINLESS STEEL ACCESSORIES TO BE SATIN FINISH UNLESS OTHERWISE NOTED. 2. MOUNT ALL ACCESSORIES PER MANUFACTURER'S RECOMMENDED MOUNTING HEIGHTS, WITHIN STATED ADA TOLERANCES. 3. WRAP ALL EXPOSED WASTE AND HOT WATER LINES PER ADA CODE. MINIMUMMIN TO TOP OF TYPICALTYP 44"SD SOAP DISPENSERSD OUTLETS ADA SIGNAGE SWITCHES AND ENVIRONMENTAL CONTROLS SWITCHES AND OUTLETSAB BASELINE OF LOWEST BRAILLE SIGNAGE48" MIN18"44"NOTE: CONFIRM WITH ELECTRICAL DRAWINGS BASELINE OF HIGHEST TACTILE CHARACTER 60" MAXMIN REQ'D CLR FLOOR SPACE CENTERED ON SIGNAGE TACTILE CHARACTERS 45°MIN 18"MIN18"SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:27:50 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated A0.01 ADA AND TYPICAL INTERIOR DETAILS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET 1/4" = 1'-0"A0.01 2 ADA DOOR CLEARANCES 1 1/2" = 1'-0"A0.01 1 TYPICAL FIRE EXTINGUISHER 1/4" = 1'-0"A0.01 4 ADA CLEARANCES AND MOUNTING HEIGHTS 1/4" = 1'-0"A0.01 3 ADA MOUNTING HEIGHTS Revision Schedule Revision Delta Issue Date P1 -PARTITION ASSEMBLY • 5/8" GYPSUM BOARD • 3 5/8" METAL STUDS • SOUND BATT INSULATION • 5/8" GYPSUM BOARD PLAN VIEW P2 -PARTITION ASSEMBLY • 3 5/8" METAL STUDS • SOUND BATT INSULATION • 5/8" GYPSUM BOARD PLAN VIEW KICKER FOR UNBRACED WALLS OVER 14'-0" IN LENGTH. REFER TO DETAIL 1/A0.02 PROVIDE 20 GA. TRACK AT WALLS LESS THAN 8'-0" IN UNBRACED LENGTH. PROVIDE 16 GA. TRACK FOR UNBRACED LENGTH BETWEEN 8'-0" AND 14'-0" SUSPENDED CEILING AS OCCURS PER REFLECTED CEILING PLAN WALL PER PLAN BOTTOM TRACK TO FINISH FLOOR CONT ACOUSTIC SEALANT BELOW TRACK, TYPICAL FLOOR FINISH, REFER TO FINISH SCHEDULE6""METAL STUD WALL AS OCCURS, SEE PARTITION TYPES FOR ADDITIONAL INFORMATION BOTTOM TRACK, ATTACH TO FLOOR. PROVIDE ACOUSTICAL SEALANT BELOW TRACK @ WALLS W/ SOUND ATTENUATION BATT INSULATION CONCRETE FLOOR SLAB AS OCCURS REMOVE TAPERED GWB EDGE AT BASE OF WALLS TO RECEIVE FLAT BASE1/2" MAX.CEILING AS OCCURS METAL STUD WALL AS OCCURS, SEE PARTITION TYPES FOR ADDITIONAL INFORMATION PER REFLECTED CEILING PLANMIN6"45.00°METAL STUD BRACING TO STRUCTURE ABOVE. REFER TO 1/A0.02 A BA COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB CEILING EDGE AT WALL 5'-10" 7'-8" 9'-9" 12'-0" 15'-0" 13'-6" 15'-0" 1/2" DIA CONDUIT (EMT) 3/4" DIA CONDUIT (EMT) 1" DIA CONDUIT (EMT) SGL 162S125-33 MTL STUD (1-5/8"x20GA) BACK TO BACK 162S125-33 MTL STUDS (1-5/8"x20GA) SGL 250S125-33 MTL STUD (2-1/2"x20GA) BACK TO BACK 250S125-33 MTL STUDS (2-1/2"x20GA) MAX. LEGNTHTABLE "ATTACHED WALL" CEILING EDGE AT WALL NTS "UNATTACHED WALL" *ALL EXPOSED WIRING TO BE PAINTED BLACK. 8" MAX. 8" MAX 6'-0" MAX NOTE: ALL GRID MEMBERS AND CONNECTION DEVICES TO BE OF AN APPROVED TYPE AND HAVE A 180# CAPACITY. ALL LATERAL BRACING WIRES TO HAVE A 200# CAPACITY. NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. BERC 2 CLIP 8" 7/8" 7/8" 3/4" BERC 2 CLIP CEILING TILE STABILIZER BAR LATERAL BRACING WITH APPROVED VERTICAL COMPRESSION STRUT AT 12'-0" OC EA WAY ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS WITHIN 8" OF PERIMETER FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO 7/8" WALL ANGLE AT 2 ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER CROSS RUNNERS FIT BETWEEN MAIN RUNNERS MAIN RUNNERS AT 4'-0" OC SUPPORT WITH #12 WIRE AT 4'-0" OC OR WITH #10 WIRE AT 5'-0" OC EA WAY LATERALLY BRACE MAIN RUNNER TO STRUCTURE AT 12'-0" OC EA WAY. BEGIN BRACING WITHIN 6'-0" OF PERIMETER AND 2" FROM CROSS MEMBER SECURE ALL HANGERS TO BLDG STRUCTURE. TRAPEZE DUCT WORK AND OTHER LARGE OBSTRUCTIONS NOTE: FOR UNATTACHED WALLS PROVIDE A 1/2" TO 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP -DO NOT SCREW BERC 2 CLIP TO TRACK 1 2 MAX.A A #10 SHEET METAL SCREWS AT 12" OC FOR ENTIRE LENGTH 3-1/2" 20 GA METAL STUD BRACING (CONTINUOUS) 20 GA ANGLE 2"x2"x2" W/ (X) SHEET METAL SCREWS EACH SIDE EXISTING TRUSS PURLIN OR TRUSS GIRDER 12 GA WIRE SUPPORT, EACH WAY. INSTALL TAUT. ATTACH VERTICAL BRACE TO T-BAR GRID W/ (2) #10 METAL SCREWS SUSPENDED CEILING NOTE: INSTALL BRACING SYSTEM EVERY 144 SF MAX OF SUSPENDED CEILING BRACE LENGTHS TO 25'-0" F U R R IN G C H A N N E L 2 4 " O N C E N T E R S P A C IN G M A X #12 HANGER WIRE 4'-0" ON CENTER SPACING MAX, GC REQ'D TO PAINT WHERE EXPOSED SADDLE TIE NO. 16 GA GALV TIRE WIRE AS RECOMMENDED BY MFR GYPSUM BOARD NOTE: SEE MFR SPECIFICATIONS AND DETAILS FOR ADDITIONAL INFORMATION. IN THE EVENT OF A CONFLICT WITH MFR REQUIREMENTS, MFR REQUIREMENTS TAKE PRECEDENCE. FURRING CHANNEL 1-1/2" CHANNELS 4'-0" ON CENTER SPACING MAX SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:27:52 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated A0.02 PARTITION TYPES AND DETAILS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET 3" = 1'-0"A0.02 2 P1 - PARTITION ASSEMBLY 3" = 1'-0"A0.02 3 P2 - PARTITION ASSEMBLY 3" = 1'-0"A0.02 4 WALL AT CEILING TRANSITION 3" = 1'-0"A0.02 5 TYPICAL WALL AT CONCRETE FLOOR 3" = 1'-0"A0.02 6 THROUGH GRID WALL 12" = 1'-0"A0.02 1 TYPICAL SUSPENDED CEILING BRACE Revision Schedule Revision Delta Issue Date UP 0 LEGEND EXISTING TO REMAIN (NO WORK IN THIS AREA) GRIDLINE EXISTING INTERIOR PARTITION EXISTING CONSTRUCTION TO BE DEMOLISHED 1 A 2 3 4 5 6 7 B C D 8 9 00-0200-02 02-01 00-01 02-01 00-01 00-0100-01 00-0100-013' - 2 1/2"1' - 2 1/2"3' - 2 1/2"1' - 5 3/4"02-02 00-0100-01 00-0100-01 02-0102-01 02-0102-01 02-09 GENERAL NOTES A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. B. DO NOT SCALE DRAWINGS. C. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING WITHOUT WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER. D. REMOVE EXISTING VERTICAL SHADES ON EXTERIOR WINDOWS. E. REMOVE EXISTING BLINDS ON EXISTING LITES AND SIDELITES. SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:27:55 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt 1/8" = 1'-0" A1.01 SEVENTH FLOOR DEMOLITION PLAN N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET KEYNOTES 00-01 EXISTING WALLS, DOORS AND RELITES TO REMAIN. PATCH AND PREP SURFACES TO RECEIVE NEW FINISHES. 00-02 NO WORK IN THIS AREA 02-01 DEMOLISH EXISTING WALLS, DOORS, FRAMES AND SIDELITES AS SHOWN. PATCH ADJACENT WALLS TO REMAIN, AS REQUIRED. PREP SURFACES TO RECEIVE NEW FINISHES. 02-02 DEMOLISH EXISTING CASEWORK. PATCH ADJACENT WALLS TO REMAIN, AS REQUIRED. PREP SURFACES TO RECEIVE NEW FINISHES. 02-09 PATCH AND REPAIR MULLION AS REQUIRED 1/8" = 1'-0"A1.01 1 SEVENTH FLOOR DEMO PLAN Revision Schedule Revision Delta Issue Date 0 LEGEND EXISTING TO REMAIN (NO WORK IN THIS AREA) GRIDLINE EXISTING INTERIOR PARTITION EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING 2 X 4 SUSPENDED ACOUSTICAL TILE 1 A 2 3 4 5 6 7 B C D 8 9 00-0200-02 02-0502-05 02-0702-07 A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. B. DO NOT SCALE DRAWINGS. C. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE BUILDING WITHOUT WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER. D. PROVIDE NEW ACOUSTIC CEILING TILE WITH NEW LED LIGHT FIXTURES IN EXISTING CEILING GRID, PER REFLECTED CEILING PLAN. E. MODIFY EXISTING CEILING GRID AS REQUIRED. GENERAL NOTES BID ALTERNATESALTERNATE NO. 1 -HVAC AND CEILING BASE BID: NO IMPACT TO HVAC, REPLACE CEILING TILE ONLY. ALTERNATE: PERFORM HVAC UPDATES PER MECHANICAL DRAWINGS, REMOVE AND REPLACE CEILING GRID AND TILE. ALTERNATE NO. 2 -LIGHTING BASE BID: NO UPDATES TO EXISTING LIGHTING EXCEPT AS REQUIRED BY NEW CONSTRUCTION. ALTERNATE: REMOVE AND REPLACE ALL LIGHTING FIXTURES WITH NEW LED FIXTURES PER ELECTRICAL DRAWINGS. BID ALTERNATES SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:27:57 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt 1/8" = 1'-0" A1.02 SEVENTH FLOOR DEMO REFLECTED CEILING PLAN N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET KEYNOTES 00-02 NO WORK IN THIS AREA 02-05 DEMOLISH EXISTING CEILING TILES, EXISTING CEILING GRID TO REMAIN. 02-07 PATCH AND REPAIR CEILING GRID AS AFFECTED BY DEMOLITION/CONSTRUCTION 1/8" = 1'-0"A1.02 1 SEVENTH FLOOR DEMO REFLECTED CEILING PLAN Revision Schedule Revision Delta Issue Date UP DN 1 A 2 3 4 5 6 7 B C D 8 9 BREAK ROOM 739 RECEPTION 733 OFFICE 736 OFFICE 735 OFFICE 734A CONFERENCE 737 OFFICE 734B SECURE FILES 738 00-02 OPEN OFFICE 734 A4.10 2 A4.10 1 7' - 0 1/4"737A736735 734B 734A 739A 738739B 733 SOUTH STAIRWELL 743 NORTH STAIRWELL 750 EXISTING MEN'S RESTROOM 748 EXISTING WOMEN'S RESTROOM 749 EXISTING ELEVATOR LOBBY 744 CORRIDOR 701 CORRIDOR 747 CORRIDOR 725 ELEV E1 ELEV E2 ELEV E4 ELEV E3 EXISTING ELECTRICAL/PHONE 746 EXISTING JANITOR 745 TELECOM 742 32' - 3 3/4"CLR5' - 0"CLR5' - 0"14' - 6" P1 +72" P1 +72"737B02-08 0 LEGEND EXISTING TO REMAIN (NO WORK IN THIS AREA) KEYNOTE GRIDLINE EXISTING INTERIOR PARTITION NEW INTERIOR PARTITION (REFER TO A0.02 FOR TYPES) ? FIRE EXTINGUISHER GENERAL NOTES A. DO NOT SCALE DRAWINGS. B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. C. CONTRACTOR TO CONFIRM ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY CONFLICTS REGARDING THE PROPOSED WORK. D. ALL WALLS TO BE WALL TYPE P1, UNLESS NOTED OTHERWISE. E. ALL GYPSUM WALLS AND SURFACES TO RECEIVE NEW PAINT, P1 TYPICAL, UNLESS NOTED OTHERWISE. F. CONTRACTOR TO INSPECT ALL MATERIALS AND PRODUCTS PRIOR TO INSTALLATION AND ENSURE PROPER INSTALLATION, PER MANUFACTURER'S INSTRUCTIONS. DEFECTIVE PRODUCTS WILL NOT BE ACCEPTABLE. G. FURNITURE SHOWN FOR SCHEMATIC PURPOSES ONLY. H. PROVIDE FIRE-TREATED WOOD BLOCKING FOR ALL WALL-MOUNTED ITEMS. I. ALL EXTERIOR WINDOWS, DOORS WITH LITES, EXISTING SIDELITES, AND CONFERENCE ROOM SIDELITE TO RECEIVE MANUAL ROLLER SHADE WINDOW TREATMENT. SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:27:59 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt 1/8" = 1'-0" A1.10 SEVENTH FLOOR PLAN N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET 1/8" = 1'-0"A1.10 1 SEVENTH FLOOR PLAN KEYNOTES 00-02 NO WORK IN THIS AREA 02-08 INFILL WALL TO ALIGN WITH EXISTING Revision Schedule Revision Delta Issue Date UP SECTION 06 41 16 - PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS PLAM (VERTICAL SURFACES): FORMICA, BLACK RIFTWOOD (6414), NATURAL GRAIN, INSTALLED: VERTICAL GRAIN SECTION 08 14 16 - FLUSH WOOD DOORS INTERIOR WOOD DOORS, STAIN TO MATCH EXISTING SECTION 09 30 13 - CERAMIC TILING T (FIELD TILE): UNITED TILE, SETTECENTO - NEW YORKER SERIES, MATTE WHITE (SCNY-167000) (3"x12") GROUT LATICRETE, COLOR: 44 BRIGHT WHITE PROVIDE SCHLUTER JOLLY TRIM AT EXPOSED EDGES IN SATIN ANODIZED ALUMINUM FINISH SECTION 09 51 00 - SUSPENDED ACOUSTICAL CEILINGS SAT ARMSTRONG, ULTIMA, 1943, EDGE: SQUARE LAY-IN 15/16", 24"x48"x7/8", COLOR: WHITE SECTION 09 65 00 - RESILIENT FLOORING RB (RUBBER BASE): 4", ROPPE, STANDARD TOE BASE, BLACK (100), FINISH: SATIN LVT1 (LUXURY VINYL TILE): 9" x 48", SHAW CONTRACT, COVE 0927V, POUR 27530, INSTALLED: ASHLAR LVT2 (ACCENT LUXURY VINYL TILE): 9" x 48", SHAW CONTRACT, COVE 0927V, WASH 27436, INSTALLED: ASHLAR SCHEDULE OF INTERIOR FINISHES SECTION 09 68 00 - CARPET CPT1 (GENERAL CARPET TILE): 12" x 36", MOHAWK, NUTOPIA, URBAN CANVAS GT412, 989 EDIFICE, INSTALLED: BRICK ASHLAR CPT2 (PRIVATE OFFICES CARPET TILE): 12" x 36", MOHAWK, LICHEN COLLECTION, FIELD OVERLAY GT403, 969 SUBSTRATE, INSTALLED: BRICK ASHLAR CPT3 (CONFERENCE ROOMS CARPET TILE): 12" x 36", MOHAWK, LICHEN COLLECTION, FIELD OVERLAY GT403, 939 CORTEX, INSTALLED: BRICK ASHLAR SECTION 09 91 23 - INTERIOR PAINTING P1 (GENERAL WALL PAINT): SHERWIN WILLIAMS, SW7757 HIGH REFLECTIVE WHITE P2 (ACCENT PAINT): SHERWIN WILLIAMS, SW9058 SECRET COVE SECTION 10 26 01 - WALL AND CORNER GUARDS CG CS ACROVYN, CO-8 AND CO-8M SURFACE MOUNTED, STAINLESS STEEL SECTION 12 24 13 - WINDOW ROLLER SHADES WC (LIGHT FILTERING): MECHOSHADE, SOHO COLLECTION, 5% OPEN, 1900 SERIES, 1912 CHARCOAL FASCIA COLOR: GREY SECTION 12 36 61.19 - QUARTZ AGGLOMERATE COUNTERTOPS QTZ (QUARTZ): PENTAL QUARTZ, BQ8806P ULIANO, 3/4" WITH BUILT UP EDGE 1 A 2 3 4 5 6 7 B C D 8 9 RB LVT1 | LVT2 P BREAK ROOM 739 RB CPT1 P RECEPTION 733 RB CPT2 P OFFICE 736 RB CPT2 P OFFICE 735 RB CPT2 P OFFICE 734A RB CPT3 P CONFERENCE 737 RB CPT2 P OFFICE 734B RB LVT P SECURE FILES 738 00-02 RB CPT1 P OPEN OFFICE 734 CG CG CGCG CG CG CG CG CG CG CG 11-04 SOUTH STAIRWELL 743 NORTH STAIRWELL 750 EXISTING MEN'S RESTROOM 748 EXISTING WOMEN'S RESTROOM 749 EXISTING ELEVATOR LOBBY 744 CORRIDOR 701 CORRIDOR 747 CORRIDOR 725 ELEV E1 ELEV E2 ELEV E4 ELEV E3 CG CG 8x10 8x10 8x10 8x10 8x8 8x10 EXISTING ELECTRICAL/PHONE 746 EXISTING JANITOR 745 TELECOM 742 P2P2CG CG CG CG CG CG CG8x10 CG 8x10 11-05 P2P2 P2 P 2A. CENTER FLOORING TRANSITIONS AT CENTER OF DOOR JAMBS, UNLESS OTHERWISE NOTED. B. PROVIDE VINYL REDUCER AT ALL FLOORING MATERIAL TRANSITIONS, UNLESS OTHERWISE NOTED. C. ALL WALLS TO BE PAINTED P1 UNLESS OTHERWISE NOTED. D. INSTALL CARPET INSETS AT ALL ELECTRICAL FLOOR BOX LOCATIONS, CARPET TO MATCH ADJACENT FLOORING MATERIAL. E. ALL EXTERIOR WINDOWS, DOORS WITH LITES, EXISTING SIDELITES, AND CONFERENCE ROOM SIDELITE TO RECEIVE MANUAL ROLLER SHADE WINDOW TREATMENT. GENERAL NOTESLEGEND CARPET 1 (CPT1) CARPET 3 (CPT3) PX ACCENT PAINT LOCATIONS FLOOR FINISH CORNER GUARD BASE FINISH WALL FINISH CARPET 2 (CPT2) LUXURY VINYL TILE (LVT1) BB FFFF WW ROOM NAME 101 CG ACCENT LUXURY VINYL TILE (LVT2) PATTERN DIRECTION SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:02 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated A1.11 SEVENTH FLOOR FINISH PLAN N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET KEYNOTES 00-02 NO WORK IN THIS AREA 11-04 VENDING MACHINE (OFOI) 11-05 TV (OFOI) 1/8" = 1'-0"A1.11 1 SEVENTH FLOOR FINISH PLAN Revision Schedule Revision Delta Issue Date 0 LEGEND EXISTING TO REMAIN (NO WORK IN THIS AREA) KEYNOTE GRIDLINE ?/6 A0.02 EXISTING INTERIOR PARTITION INTERIOR PARTITION THRU GRID (REFER TO FOR TYPES) INTERIOR PARTITION TO UNDERSIDE OF GRID (REFER TO FOR TYPES) 2 X 4 SUSPENDED ACOUSTICAL TILE (SAT) /6 A0.02 1 A 2 3 4 5 6 7 B C D 8 9 CONFERENCE 737 BREAK ROOM 739 SECURE FILES 738 RECEPTION 733 OPEN OFFICE 734 OFFICE 736 OFFICE 735 OFFICE 734B OFFICE 734A 00-02 SOUTH STAIRWELL 743 NORTH STAIRWELL 750 EXISTING MEN'S RESTROOM 748 EXISTING WOMEN'S RESTROOM 749 EXISTING ELEVATOR LOBBY 744 CORRIDOR 701 CORRIDOR 747 CORRIDOR 725 ELEV E1 ELEV E2 ELEV E4 ELEV E3 EXISTING ELECTRICAL/PHONE 746 EXISTING JANITOR 745 TELECOM 742 A. EXISTING SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-8" AFF, UNLESS OTHERWISE NOTED. B. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAIL C. PROVIDE HOLE FOR PENETRATION THROUGH SUSPENDED ACOUSTICAL TILE FOR ELEMENTS INCLUDING, BUT NOT LIMITED TO, SPRINKLER HEADS, CONDUITS, ETC., OF SUFFICIENT SIZE TO ACCOMMODATE ONE (1) INCH OF LATERAL MOVEMENT IN EVERY DIRECTION OF ASSEMBLY PENETRATING CEILING PLANE. PROVIDE ESCUTCHEON TO CONCEAL GAP BETWEEN CEILING TILE AND PENETRATING ELEMENT. D. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF 2X2 PORTION OF 2X4 TILE, UNLESS OTHERWISE NOTED. E. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING LAYOUT. GENERAL NOTES /1 A0.02 BID ALTERNATESALTERNATE NO. 1 -HVAC AND CEILING BASE BID: NO IMPACT TO HVAC, REPLACE CEILING TILE ONLY. ALTERNATE: PERFORM HVAC UPDATES PER MECHANICAL DRAW INGS, REMOVE AND REPLACE CEILING GRID AND TILE. ALTERNATE NO. 2 -LIGHTING BASE BID: NO UPDATES TO EXISTING LIGHTING EXCEPT AS REQUIRED BY NEW CONSTRUCTION. ALTERNATE: REMOVE AND REPLACE ALL LIGHTING FIXTURES WITH NEW LED FIXTURES PER ELECTRICAL DRAWINGS. BID ALTERNATES SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:04 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt 1/8" = 1'-0" A1.20 SEVENTH FLOOR REFLECTED CEILING PLAN N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET KEYNOTES 00-02 NO WORK IN THIS AREA 1/8" = 1'-0"A1.20 1 SEVENTH FLOOR REFLECTED CEILING PLAN Revision Schedule Revision Delta Issue Date FAUCET CONTROL 1' - 5" MAX TO 5"3/4"8"2' - 3" MIN2' - 4" CLR6"9"QUARTZ COUNTER TOP WITH SELF EDGE OVER 3/4" PLYWOOD WRAP ALL EXPOSED PIPE PER CODE PLASTIC LAMINATE CABINET FACE OPEN BELOW PER CODE (2) ADJUSTABLE MELAMINE SHELVES PLASTIC LAMINATE CABINET FACE TILE BACKSPLASH INTERIOR ELEVATIONREFER TOINTERIOR ELEVATIONREFER TOINTERIOR ELEVATIONREFER TOINT ELEV REFER TO B 8 A4.106 A4.10 4A4.10 3 5 P1 +104" P1 +104" P1 +104" ALIGN ALIGN ALIGNALIGN RECEPTION 733 6' - 6" 2' - 4" A4.107 P1P1739BBREAK ROOM 739 5' - 6"11-02 739A 11-04 P2 +104" 22-01 12' - 5"30"42"48" OPEN TO BEYOND 9 A4.10 8 A4.10 OPEN 30"42"06-04 06-05 8 A4.10 9 A4.10 OPEN TO BEYOND 30"EQ EQ 10 A4.10 24" D 30" 24" D 3 EQ 15 A4.10 06-03 06-05 34"10-03 34"10' - 10" 15" D 5 EQ 6' - 6" 24" D 3 EQ 12 A4.10 11-01 06-02 06-03 06-01 36"10-03 10-03 11 A4.1018"32"50"CLR 60"36"36" VERIFY 24"12"34"06-04 09-01 11-03 06-01 11-02 22-02 24" D 13 A4.10 12 A4.10 14 A4.1050"33"15" D 3 EQ 9' - 0" 24" D QUARTZ COUNTERTOP AND SPLASH WITH SELF EDGE OVER 3/4" PLYWOOD MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"CLR9"ELEVATION REFER TO INTERIOR INTERIOR ELEVATIONREFER TOCLR11"ELEVATIONREFER TO INTERIORELEVATIONREFER TO INTERIOR INTERIOR ELEVATIONREFER TOPLASTIC LAMINATE CABINET FACE INT ELEV REFER TO (2) ADJUSTABLE MELAMINE SHELVES QUARTZ COUNTERTOP WITH SELF EDGE OVER 3/4" PLYWOOD MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"ELEVATION REFER TO INTERIOR (1) ADJUSTABLE MELAMINE SHELF TILE BACKSPLASH (AS OCCURS, REFER TO INTERIOR ELEVATIONS)ELEVATIONREFER TO INTERIORPLASTIC LAMINATE CABINET FACE INT ELEV REFER TO (2) ADJUSTABLE MELAMINE SHELVES QUARTZ COUNTERTOP AND SPLASH WITH SELF EDGE OVER 3/4" PLYWOOD (AS OCCURS, REFER TO INTERIOR ELEVATIONS) MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"CLR9"ELEVATION REFER TO INTERIOR INTERIOR ELEVATIONREFER TOCLR11"ELEVATIONREFER TO INTERIORTILE BACKSPLASH (AS OCCURS, REFER TO INTERIOR ELEVATIONS) QUARTZ COUNTERTOP WITH SELF EDGE OVER 3/4" PLYWOOD MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"EQELEVATION REFER TO INTERIORINTERIOR ELEVATIONREFER TO3 5/8" STUD WITH (1) LAYER OF GWB EA SIDE EQ4"QUARTZ COUNTERTOP AND WITH SELF EDGE OVER 3/4" PLYWOOD MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"EQELEVATION REFER TO INTERIORINTERIOR ELEVATIONREFER TOEQREFER TO INTERIOR ELEVATION4"3 5/8" STUD WALL WITH 5/8" GWB EA SIDE QUARTZ COUNTERTOP WITH SELF EDGE OVER 3/4" PLYWOOD. ALIGN PLYWOOD EDGE ON RECEPTIONIST SIDE WITH FACE OF GWB 7" 1"INT ELEVATIONREFER TOREFER TO INTERIOR ELEVATIONELEVATIONREFER TO INTERIOR INTERIOR ELEVATIONREFER TOPLASTIC LAMINATE CABINET FACE INT ELEV REFER TO (2) ADJUSTABLE MELAMINE SHELVES QUARTZ COUNTERTOP AND SPLASH WITH SELF EDGE OVER 3/4" PLYWOOD MELAMINE INTERIOR PLASTIC LAMINATE CABINET FACE BASE PER FINISH FLOOR PLANCLR4"ELEVATION REFER TO INTERIOR (1) ADJUSTABLE MELAMINE SHELF (5) ADJUSTABLE DIVIDERS, FINISHED PLASTIC LAMINATE (2) STATIONARY VERTICAL DIVIDERS, EQUALLY SPACED, FINISHED PLASTIC LAMINATE QUARTZ COUNTERTOP WITH SELF EDGE OVER 3/4" PLYWOOD BASE PER FINISH FLOOR PLANINTERIOR ELEVATIONREFER TOWALL TYPE PER PLAN 7"1" ELEVATION REFER TO INTERIOR 1/2" x 2-1/2" FLAT BAR, BOLTS TO STUD WITH WASHER EACH SIDE STUD PER WALL TYPE AT EACH FLAT BAR SUPPORT PAINT GWB AND EXPOSED METAL P1, TYP.REFER TO INTERIOR ELEVATIONSHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:07 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated A4.10 ENLARGED PLANS, INTERIOR ELEVATIONS & DETAILS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET KEYNOTES 06-01 PLASTIC LAMINATE BASE CABINET 06-02 PLASTIC LAMINATE UPPER CABINET 06-03 QUARTZ COUNTERTOP AND 4" BACKSPLASH 06-04 QUARTZ COUNTERTOP 06-05 PLASTIC LAMINATE LOCKING BASE CABINET 09-01 TILE BACKSPLASH TO UNDERSIDE OF UPPER CABINETS 10-03 CORNER GUARD 11-01 COPIER | SCANNER (OFOI) 11-02 REFRIGERATOR (OFOI) 11-03 COUNTERTOP MICROWAVE (OFOI) 11-04 VENDING MACHINE (OFOI) 22-01 UNDERMOUNT SINK (REFER TO PLUMBING) 22-02 DISHWASHER (REFER TO PLUMBING) 3/4" = 1'-0"A4.10 13 CASEWORK SECTION - ADA SINK 1/4" = 1'-0"A4.10 1 ENLARGED FLOOR PLAN - RECEPTION 733 1/4" = 1'-0"A4.10 2 ENLARGED FLOOR PLAN - BREAK ROOM 739 1/4" = 1'-0"A4.10 3 RECEPTION 733 - SOUTH 1/4" = 1'-0"A4.10 5 RECEPTION 733 - NORTH 1/4" = 1'-0"A4.10 4 RECEPTION 733 - SOUTH 1/4" = 1'-0"A4.10 6 RECEPTION 733 - NORTH 1/4" = 1'-0"A4.10 7 BREAK ROOM 739 - NORTH 3/4" = 1'-0"A4.10 15 CASEWORK SECTION 3/4" = 1'-0"A4.10 12 CASEWORK SECTION 3/4" = 1'-0"A4.10 14 CASEWORK SECTION 3/4" = 1'-0"A4.10 8 RECEPTION DESK SECTION 3/4" = 1'-0"A4.10 9 RECEPTION DESK SECTION 3/4" = 1'-0"A4.10 11 CASEWORK SECTION 3/4" = 1'-0"A4.10 10 RECEPTION DESK SECTION Revision Schedule Revision Delta Issue Date FF FACTORY FINISH HM HOLLOW METAL P PAINT S STAIN SC SOLID CORE WOOD - STAIN TO MATCH ARCH. SAMPLE T TEMPERED GLASS WD WOOD DOOR SCHEDULE ABBREVIATIONS H1 - LEVER LOCK SET - BUTTS - LEVER LOCK SET - MORTISE CORE - PANIC HARDWARE (PUSH SIDE ONLY) - KICK PLATE (PUSH SIDE ONLY) - PULL - CLOSER - GASKETING DOOR HARDWARE H3 - CARD READER - BUTTS - LEVER LOCK SET WITH CARD READER - MORTISE CORE - KICKPLATE (PUSH SIDE ONLY) - STOP - CLOSER - GASKETING H2 - LEVER LOCK SET - BUTTS - LEVER LOCK SET - MORTISE CORE - KICK PLATE (PUSH SIDE ONLY) - PULL - CLOSER - GASKETING A B TLOUVER WHERE OCCURS 38 3/4"9 3/4"16 1/2"9 3/4"44 1/2"C T 6"24"6"6"6"12"5"6"3' - 6"WALL AS SCHEDULED PAINTED HOLLOW METAL DOOR FRAME, REFER TO DOOR SCHEDULE DOOR AS SCHEDULED CAULK ALL SIDES TYP. FILL WITH MINERAL WOOL INSUL. DOOR PER SCHEDULE 3' - 0"8' - 0"FRAME PER SCHEDULE A JAMB BEYOND DOOR PER SCHEDULE UNDERCUT DOOR AS REQUIRED FINISHED FLOOR HINGE SIDE SHEET JOB NO. SHEET TITLE: CHECKED BY: DRAWN BY: Project Client 12/14/2022 8:28:08 AMBIM 360://Renton City Hall - 7th Floor HR/Renton 7th Floor HR-B.rvt As indicated A6.10 DOOR SCHEDULE, DOOR DETAILS N/A N/A RENTON CITY HALL - 7TH FLOOR HR TENANT IMPROVEMENT 1055 S Grady Way, Floor 7, Renton, WA 98057 City of Renton 2210142.00 01/03/2023PERMIT | BID SET DOOR SCHEDULE DOOR DOOR FRAME DETAIL HDWR GROUP RATING COMMENTSWIDTH HEIGHT THK TYPE MAT'L FINISH TYPE MAT'L FINISH HEAD JAMB SILL 733 3' - 0" 8' - 0" 1 3/4" C SC S 1 HM P 1/A6.10 1/A6.10 2/A6.10 1 45 MIN 734A 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 734B 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 735 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 736 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 737A 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 737B 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 738 3' - 0" 8' - 0" 1 3/4" A SC S 1 HM P 1/A6.10 1/A6.10 2/A6.10 3 739A 3' - 0" 8' - 0" 1 3/4" B SC S 1 HM P 1/A6.10 1/A6.10 2/A6.10 2 739B 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST 1/4" = 1'-0" DOOR TYPES 3" = 1'-0"A6.10 1 TYPICAL DOOR JAMB DETAIL (HEAD SIM) 1/4" = 1'-0" FRAME TYPES Revision Schedule Revision Delta Issue Date 3" = 1'-0"A6.10 2 TYPICAL DOOR SILL M0.01CCWSCWREBALL VALVEEXISTING PIPINGCONDENSATE PIPINGCONDENSER WATER RETURNCONDENSER WATER SUPPLYBUTTERFLY VALVEPIPE DOWNPIPE UPUNIONCROSSING LINES, NON CONNECTINGELBOWS, 90° & 45°CAPTEEIN LINE WASTE CONNECTIONP-TRAPBRANCH PIPE DOWNBRANCH PIPE UP CLEAN OUT (CO)WASTE OR VENT UPWALL CLEANOUTDOMESTIC HOT WATER (HW)DOMESTIC HOT WATER CIRCULATING (HWC)VENT (V), OR HIDDEN BELOW WASTEDOMESTIC COLD WATER (CW)SOIL, WASTE (S, W)PIPE CONTINUATIONMECHANICAL LEGENDHVACSUPPLY DUCT UPSUPPLY DUCT DOWNRETURN, RELIEF, TRANSFER, OSA DUCT UPRETURN, RELIEF, TRANSFER, OSA DUCT DOWN300 CFM12 X 12 CDROUND DUCT ELBOW UPVOLUME DAMPER (VD)TBACKDRAFT DAMPER (BD)THERMOSTAT (T'STAT)TURNING VANES (TV)FLEXIBLE DUCTCEILING AIR TERMINAL - SQUAREAIR TERMINAL SIZE, TYPE & CFMRECTANGULAR DUCT, RADIUS ELBOW UPRECTANGULAR DUCT SQUARE ELBOW UPPLUMBING/HYDRONICSYMBOLDESCRIPTIONSYMBOLDESCRIPTIONSYMBOLDESCRIPTIONSYMBOLDESCRIPTIONELECTRICAL CONTRACTORPOINT OF CONNECTIONMECHANICAL CONTRACTORMCECPOCGENERAL CONTRACTORGCBELOW FINISHED FLOORBFFABOVE FINISHED FLOORAFFX/XSQUARE DUCTXØROUND DUCTWPROJECT NOTES:1.PROJECT CLOSEOUT REQUIREMENTS ARE LISTED IN SPECIFICATION SECTION 20 0000, GENERAL MECHANICAL REQUIREMENTS. CONTRACTOR SHALL COMPLY WITHSPECIFICATION FOR SUBMITTAL OF RECORD DOCUMENTS, O&M MANUALS, AND WSECCOMPLIANCE FORMS.2.COMMISSIONING PER SECTION C408 OF THE 2018 WSEC IS REQUIRED. REFER TOSPECIFICATION 20 00 00, SECTION 1.18 FOR COMMISSIONING REQUIREMENTS.CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COMMISSIONING COMPLIANCECHECKLIST TO THE CODE OFFICIAL (SEE FIGURE C408.1.4.1 OF THE 2018 WSEC).CHECKLIST MUST BE SIGNED BY BUILDING OWNER.3.AIR SYSTEM TEST AND BALANCE SHALL BE PERFORMED BY LICENSED TABCONTRACTOR, IN ACCORDANCE WITH SPECIFICATION 23 05 93.4.COORDINATE MECHANICAL WORK WITH ELECTRICAL, ARCHITECTURAL, STRUCTURAL,CIVIL AND LANDSCAPE WORK SHOWN ON OTHER CONTRACT DOCUMENTS. PROVIDEADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED.5.COORDINATE HVAC, PLUMBING AND FIRE PROTECTION WORK PRIOR TOINSTALLATION. DUCTWORK AND EQUIPMENT ACCESS TAKES PRECEDENCE OVER ALLPIPING EXCEPT GRAVITY SYSTEMS FOR AVAILABLE SPACE.6.COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIEDDRAWINGS. COORDINATE AND PROVIDE DUCT AND PIPING TRANSITIONS REQUIREDFOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY ANDCOORDINATE DUCT AND PIPING DIMENSIONS BEFORE FABRICATION.7.LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BECOORDINATED WITH OTHER TRADES INVOLVED.8.THIS BUILDING UTILIZES POST TENSION SLABS BETWEEN FLOORS. GC TO X-RAYFLOOR PRIOR TO ANY PENETRATIONS.HVAC NOTES:1.ALL DUCTWORK TO BE CONSTRUCTED AND SEALED PER IMC AND SMACNA PRESSURECLASS 2" (LOW PRESSURE) REQUIREMENTS. ALL DUCTS TO BE SEALED TO SMACNASEAL CLASS A.2.REFER TO SPECIFICATION 23 31 13 FOR DUCTWORK INSULATION REQUIREMENTS.3.ALL REFRIGERANT/HVAC PIPING SHALL BE INSULATED PER 2018 WSECREQUIREMENTS. REFER TO SPECIFICATION 23 07 19 FOR SPECIFIC PIPINGINSULATION REQUIREMENTS.PIPING NOTES:1.ALL DOMESTIC HOT AND COLD WATER PIPING SHALL BE INSULATED PERSPECIFICATION 22 07 19. INSULATION SHALL BE PROVIDED FROM THE WATER HEATERTO THE FINAL FIXTURE.FIRE PROTECTION NOTES:1.THE FIRE PROTECTION SPRINKLER SYSTEM CONTRACTOR SHALL ADD, DELETE, ORRELOCATE EXISTING SPRINKLERS AND PIPING AS REQUIRED TO REFLECT NEW ANDMODIFIED WALLS, CEILINGS, HVAC GRILLES, AND LIGHT LOCATIONS, IN ACCORDANCEWITH CITY OF RENTON, THE 2015 INTERNATIONAL FIRE CODE (IFC), AND THE 2016EDITION OF NFPA #13.2.NEW FIRE SPRINKLERS SHALL BE CHROME PENDENT SPRINKLERS WITH CHROMESEMI-RECESSED ESCUTCHEONS TO MATCH THE EXISTING STYLE. (EXISTINGSPRINKLERS ARE CHROME/CHROME RELIABLE MODEL-G RECESSED.)3.SPRINKLER LOCATIONS IN ACOUSTIC CEILING TILES SHALL BE INSTALLED IN ACONSISTENT PATTERN, CENTERED WITHIN THE CEILING TILE (12" FROM A CEILINGGRID), AND PLACED TO AVOID ALL LIGHTS AND HVAC DIFFUSERS.4.ALL SPRINKLERS REMOVED FROM THEIR FITTINGS FOR RELOCATION SHALL BECHANGED-OUT TO NEW SPRINKLERS.5.THE USE OF FLEXIBLE DROPS TO PENDENT SPRINKLERS IS ACCEPTABLE. INSUSPENDED CEILINGS, ALL NEW SPRINKLER PENETRATIONS FOR DROPS THAT AREHARD-PIPED SHALL BE OVER-SIZED TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS PERASTM E580, WITH THE OVER-SIZED HOLES CONCEALED BY OVER-SIZEDESCUTCHEONS/RINGS PROVIDED BY THE SPRINKLER CONTRACTOR.PROJECT SCOPE:1.BASE BID: UNDER THE BASE BID, THE EXISTING HVAC SYSTEM AND CONTROLS WILLREMAIN.2.ALTERNATE BID NO. 1: UNDER ALTERNATE BID NO.1, THE HVAC SYSTEM ANDCONTROLS WILL BE UPDATED AS SHOWN ON SHEETS MD1.01, MD1.11, M2.01, M2.11.3.NEW PLUMBING WORK SHOWN ON M1.01 IS UNDER THE BASE BID.4.SEE ARCHITECTURAL PLANS FOR ADDITIONAL ALTERNATE BID INFORMATION.5.PROVIDE FIRE SPRINKLER HEAD RELOCATION AS NECESSARY FOR LIGHTINGREVISIONS UNDER THE BASE BID. PROVIDE FIRE SPRINKLER HEAD RELOCATION ASNECESSARY FOR EITHER ALTERNATE BID NO. 1 OR NO. 2.EXISTING(E)MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM0.01MECHANICALLEGEND &NOTES12/13 /2022 UP1A234567BCD89VAV720VAV715VAV717VAV713VAV704P-4CWRCWRCWSCWSCWRCWSCWSCWSCWRCWRCWRCWRCWRCWSCWRCWS CWR14/618/1010Ø16/1014/810Ø14/1212/614/612/66Ø16/108/1214/1216/616/1010Ø8Ø8Ø16/1014/1218/88Ø8Ø8Ø12Ø10Ø12Ø (E)12Ø (E)CAP 12Ø10Ø6Ø10Ø12Ø8Ø10Ø8ØCAP6Ø8Ø10"Ø8Ø8Ø6Ø10Ø9Ø9Ø12Ø9Ø6Ø (4 TYP)8Ø6Ø (4 TYP)8Ø8Ø16/1216/616/814/614/1212/108Ø8Ø8/1012/1016/108Ø6Ø16/612Ø16/616/616/616/812/620/812/612/612/620/1012/618/810/610/1010/614/614/1210ØVAV714VAV71916/10VAV723VAV721VAV722VAV724VAV729VAV72716/1316/81" HW2" CW2" V10/614/814/1010/108/612/816/1020/1016/616/88/68/618/814/620/1212/614/610/616/814/12 (E)12/612/68/68/612/816/88Ø16/108Ø10/616/614/616/810Ø16/1212/1012/614/1014/614/1212/620/1236/820Ø DNVAV712HP7026" CWR DN10/618/1424ØCWR UP16/62" V4"4" CWS UP4" CWR UP16/1214/10VAV730VAV733VAV732VAV708VAV706VAV701VAV702VAV703VAV705VAV710VAV709VAV711VAV716VAV725VAV726VAV731VAV728VAV7074" V. DN10/68/610/88/624/68/68Ø (E)10Ø10"Ø10/88Ø10/8 LINED9Ø8Ø16Ø3"12/61-1/2"14/818Ø DN6" CWS DNCONN. TOEXIST. PIPING12/1214Ø18Ø20Ø14ØCAP4"3"2"CAPHP70114/1214/1214Ø14Ø20Ø20Ø22Ø 22Ø8/410Ø (E)4"4"28Ø 28Ø12Ø DN14/1214/1214Ø12Ø14/18 UPTO AHU-118/103"VTR4"VTR4"W DN4"VTRCONN. TOEXIST. PIPING14/8 DN14/10 DNUP TOEF-214/12EF32221111111VAV7181112/612/6223DEMOLITION NOTESDEMOLISH TERMINAL UNIT AND ASSOCIATED APPURTENANCES.CAP AND SEAL DUCTWORK AT MAIN, FOR FUTURE USE.ALL DEMOLITION WORK SHOWN IN THIS AREA IS TO BE DEMOLISHED ANDREPLACED UNDER ALTERNATE BID NO.1.123GENERAL NOTES1.ITEMS SHOWN IN DARK AND DASHED INDICATE EXISTING ITEMS TO BEREMOVED. ITEMS SHOWN LIGHT REPRESENT EXISTING TO REMAIN.2.ITEMS SHOWN IN GREY AREA IS EXISTING TO REMAIN AND SHOWN FORREFERENCE ONLY, UNLESS OTHERWISE NOTED.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCMD1.01SEVENTHFLOORMECHANICALDEMOLITIONPLAN 1/8" = 1'-0"MD1.011SEVENTH FLOOR MECHANICAL DEMOLITION PLAN12/13 /2022 1A234567BCD89TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT12Ø280 CFM12Ø280 CFM 2 TYP.10Ø270 CFM 3 TYP.8Ø200 CFM 4 TYP.16Ø450 CFM14Ø335 CFM14Ø335 CFM14Ø330 CFM14Ø350 CFM 2 TYP.14Ø400 CFM 2 TYP.12Ø300 CFM14Ø360 CFM10Ø250 CFM 2 TYP.8Ø170 CFM 2 TYP.10Ø250 CFM 2 TYP.8Ø200 CFM 3 TYP.16Ø460 CFM12Ø320 CFM10Ø210 CFM10Ø260 CFM12Ø280 CFM 3 TYP.10"Ø260 CFM16Ø460 CFM8Ø120 CFM 6 TYP.8Ø200 CFM10"Ø260 CFM 2 TYP.10Ø210 CFM10Ø210 CFM10Ø240 CFM10Ø240 CFM8Ø160 CFM24/12 RG600 CFM20Ø8X8 EG120 CFM6Ø60 CFM6Ø30 CFM6Ø30 CFM8Ø150 CFM8Ø150 CFM16Ø600 CFM6Ø100 CFM10Ø250 CFM10Ø240 CFM12Ø320 CFM12Ø320 CFM14Ø340 CFM12Ø280 CFM14Ø360 CFM16Ø480 CFM10Ø240 CFM12/6 RG240 CFM8X8 EG140 CFM EA.6Ø40 CFM8Ø140 CFM4'-0" 2 SLOT190 CFM EA4" WX10"H PLENUM4 TYPICAL3'-0" 3 SLOT190 CFM EA8"Wx10"H PLENUM3 TYPICAL4'-0" 3 SLOT245 CFM EA8"Wx10"H PLENUM4 TYPICAL24x3 BAR GR.95 CFM EA2 TYPICAL24x3 BAR GR.125 CFM EA6 TYPICAL24x3 BAR GR.125 CFM EA6 TYPICALTT1111124/12 RG24/12 RG124/12 RG24/12 RG24/12 RG24/12 RG11224/12 RG24/12 RG24/12 RGDEMOLITION NOTESEXISTING THERMOSTAT TO BE REMOVED, DISCARD OR RETURN TO OWNER ATOWNER'S DISCRETION.ALL DEMOLITION WORK SHOWN IN THIS AREA IS TO BE DEMOLISHED ANDREPLACED UNDER ALTERNATE BID NO.1.12GENERAL NOTES1.ITEMS SHOWN IN DARK AND DASHED INDICATE EXISTING ITEMS TO BEREMOVED. ITEMS SHOWN LIGHT REPRESENT EXISTING TO REMAIN.2.ITEMS SHOWN IN GREY AREA IS EXISTING TO REMAIN AND SHOWN FORREFERENCE ONLY, UNLESS OTHERWISE NOTED.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCMD1.11SEVENTHFLOORMECHANICALDEMOLITIONRCP 1/8" = 1'-0"MD1.111SEVENTH FLOOR MECHANICAL DEMOLITION RCP12/13 /2022 3/4" CW3P-12P-2HWT11CWRCWRCWSCWSCWRCWSCWSCWSCWRCWRCWRCWRCWRCWSCWRCWS CWR6" CWR DN(E) CWR UP4"4" CWS UP4" CWR UP3"6" CWS DN4"3"4" (E)4"(E) 4"VTR,(E) 4"W DN1" HW2" CWCONNECTION TOEXIST. PIPING2" V2" V4" V. DN4"VTR1-1/2"BREAKROOM739RECEPTION733OFFICE736OFFICE735OFFICE734ACONFERENCE737OFFICE734BSECUREFILES73812" FD2" FDHP7014OPEN OFFICE734UPDN1A234567BCD89CONSTRUCTION NOTESROUTE 2"W, 1-1/2"V HORIZONTAL IN WALL AND CONNECT TO EXISTING 4"W AND 4"VRISER. FIELD VERIFY LOCATIONS.PROVIDE CONNECTION TO ADJACENT DISHWASHER.CONNECT NEW PIPING TO EXISTING, FIELD VERIFY LOCATIONS.MC / GC TO ENSURE WORK DOES NOT IMPACT WALL IN SECURE ROOM ADJACENTTO BREAK ROOM. PROTECT WALL ON BREAK ROOM SIDE DURING WORK TOGREATEST EXTENTS POSSIBLE.123PHASE NOTESCOORDINATE NEW COLD WATER PIPING WORK WITH ARCHITECTURAL PLANS ANDGC. WORK TO BE COORDINATED AROUND TENANT OCCUPIED SCHEDULE.14GENERAL NOTES1.ITEMS SHOWN LIGHT INDICATE EXISTING ITEMS TO REMAIN.2.PIPING IS SHOWN OFFSET FOR CLARITY. CONTRACTOR TO PROVIDEADDITIONAL OFFSETS, AS REQUIRED, TO INSTALL A COMPLETE ANDFUNCTIONING PIPING SYSTEM.3.COORDINATE WITH ALL TRADES PRIOR TO INSTALLATION.4.CONFIRM LOCATION OF ALL EXISTING UTILITIES PRIOR TO INSTALLATION.5.ITEMS SHOWN IN GREY AREA IS EXISTING TO REMAIN AND SHOWN FORREFERENCE ONLY, UNLESS OTHERWISE NOTED.6.THIS BUILDING UTILIZES POST TENSION SLABS BETWEEN FLOORS. GC TOX-RAY FLOOR PRIOR TO ANY PENETRATIONS.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM1.01SEVENTHFLOORPLUMBINGPLAN 1/8" = 1'-0"M1.011SEVENTH FLOOR PLUMBING PLAN12/13 /2022 UPDN1A234567BCD89VAV724VAV722VAV716VAV720VAV718VAV719VAV721VAV723VAV717VAV715VAV713VAV70414/128Ø8Ø12Ø10Ø12Ø (E)12Ø (E)CAP 12Ø10Ø6Ø10Ø12Ø8Ø10Ø8ØCAP6Ø8Ø10"Ø8Ø6Ø10Ø9Ø9Ø12Ø9Ø6Ø (4 TYP)8Ø6Ø (4 TYP)8Ø16/814/614/1212/108Ø8Ø8/1012/1016/108Ø6Ø12Ø16/616/616/616/812/620/812/612/612/620/1012/618/810/610/1010/614/614/1210ØVAV714VAV729VAV72716/1316/810/614/814/1010/108/612/816/1020/1016/616/88/68/618/814/620/1212/614/610/616/814/12 (E)12/612/68/68/612/816/88Ø16/108Ø10/616/614/616/810Ø16/1212/1012/614/1014/614/1212/620/1236/820Ø DNVAV712HP70210/618/1424Ø16/616/1214/10VAV730VAV733VAV732VAV708VAV706VAV701VAV702VAV703VAV705VAV710VAV709VAV711VAV725VAV726VAV731VAV728VAV70710/68/610/88/624/68/68Ø (E)10Ø10"Ø10/88Ø10/8 LINED9Ø8Ø16Ø12/614/818Ø DN12/1214Ø18Ø20Ø14ØCAPCAPHP70114/1214/1214Ø20Ø20Ø22Ø 22Ø8/410Ø (E)28Ø 28Ø12Ø DN14/1212Ø14/18 UPTO AHU-118/1014/8 DN14/10 DNUP TOEF-214/12EF312/6BREAKROOM739RECEPTION733OFFICE736OFFICE735OFFICE734ACONFERENCE737OFFICE734BSECUREFILES738OPEN OFFICE73412/108Ø12Ø6Ø10Ø10Ø10Ø12Ø10Ø14/1212Ø10Ø14/1212Ø12/1010Ø10Ø10Ø10Ø12/1010Ø10Ø10Ø12/1010Ø12/1010Ø12/106Ø10Ø12Ø12Ø10Ø10Ø10Ø12Ø8Ø10Ø111114Ø116Ø18Ø22222222228Ø2OPEN OFFICE7343CONSTRUCTION NOTESPOINT OF CONNECTION TO EXISTING DUCTWORK.PROVIDE 1" SOUNDLINED DUCTED RELIEF/TRANSFER TO PLENUM. TERMINATE ENDSWITH BIRD SCREEN. SEE DETAIL 4 ON M5.01.ALL NEW WORK SHOWN IN THIS AREA IS TO BE REPLACED UNDER ALTERNATE BIDNO.1.123GENERAL NOTES1.ITEMS SHOWN LIGHT INDICATE EXISTING ITEMS TO REMAIN.2.DUCTWORK SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION.3.ALL DUCTWORK OFFSET/ELBOWS MAY NOT BE SHOWN ON PLANS. CONTRACTORSHALL PROVIDE OFFSETS AS REQUIRED TO ALLOW DUCT RATING AROUNDSTRUCTURE OR OTHER INTERFERENCES.4.ITEMS SHOWN IN GREY AREA IS EXISTING TO REMAIN AND SHOWN FOR REFERENCEONLY, UNLESS OTHERWISE NOTED.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM2.01SEVENTHFLOORMECHANICALPLAN 1/8" = 1'-0"M2.011SEVENTH FLOOR MECHANICAL PLAN12/13 /2022 1A234567BCD8900-0212/12 CD-4275 CFM12/12 CD-4270 CFM12/12 CD-4270 CFM12/12 CD-4270 CFM12/12 CD-4280 CFM(TYP 2)12/12 CD-4260 CFM12/12 CD-4250 CFM12/12 CD-4280 CFM12/12 CD-4285 CFM12/12 CD-4400 CFM12/12 CD-4285 CFM12/12 CD-4100 CFM12/12 CD-4285 CFM12/12 CD-4225 CFM6/6 CD-460 CFM24/12 RG24/12 RG24/12 RG24/12 RG24/12 RGTTTTTTTTTT24/12 RG24/12 RG24/12 RG24/12 RG24/12 RG24/12 RG11111111111BREAK ROOM739SECUREFILES738OFFICE736OFFICE735OFFICE734BOFFICE734AVAV-724VAV-723VAV-717VAV-721VAV-719VAV-722VAV-720VAV-718T22VAV-7162TTTTTTTTTTTTTTTTTTTTTT14Ø335 CFM14Ø335 CFM14Ø330 CFM12Ø300 CFM10Ø250 CFM 2 TYP.8Ø170 CFM 2 TYP.8Ø200 CFM 3 TYP.16Ø460 CFM12Ø320 CFM10Ø210 CFM10Ø260 CFM12Ø280 CFM 3 TYP.10"Ø260 CFM16Ø460 CFM8Ø120 CFM 6 TYP.8Ø200 CFM10"Ø260 CFM 2 TYP.10Ø210 CFM10Ø210 CFM10Ø240 CFM10Ø240 CFM8Ø160 CFM24/12 RG600 CFM20Ø8X8 EG120 CFM6Ø60 CFM6Ø30 CFM6Ø30 CFM8Ø150 CFM8Ø150 CFM16Ø600 CFM6Ø100 CFM10Ø250 CFM10Ø240 CFM12Ø320 CFM12Ø320 CFM14Ø340 CFM12Ø280 CFM14Ø360 CFM16Ø480 CFM10Ø240 CFM12/6 RG240 CFM8X8 EG140 CFM EA.6Ø40 CFM8Ø140 CFM4'-0" 2 SLOT190 CFM EA4" WX10"H PLENUM4 TYPICAL3'-0" 3 SLOT190 CFM EA8"Wx10"H PLENUM3 TYPICAL4'-0" 3 SLOT245 CFM EA8"Wx10"H PLENUM4 TYPICAL24x3 BAR GR.95 CFM EA2 TYPICAL24x3 BAR GR.125 CFM EA6 TYPICAL24x3 BAR GR.125 CFM EA6 TYPICALTTVAV-7182RECEPTION733CONFERENCE737OPEN OFFICE73439/9 CD-4200 CFMCONSTRUCTION NOTESPROVIDE NEW GRILLE WITH 1" SOUNDLINED DUCTED ELBOW.PROVIDE AVERAGING THERMOSTATS FOR ASSOCIATED VAV.ALL NEW WORK SHOWN IN THIS AREA IS TO BE REPLACED UNDER ALTERNATE BIDNO.1.123GENERAL NOTES1.ITEMS SHOWN LIGHT INDICATE EXISTING ITEMS TO REMAIN.2.ITEMS SHOWN IN GREY AREA IS EXISTING TO REMAIN AND SHOWN FOR REFERENCEONLY, UNLESS OTHERWISE NOTED.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM2.11SEVENTHFLOORMECHANICALREFLECTEDCEILING PLAN 1/8" = 1'-0"M2.111SEVENTH FLOOR MECHANICAL REFLECTED CEILING PLAN12/13 /2022 M5.01SCALE:1RECTANGULAR TO ROUND DUCT TAKE-OFFAND TRANSITION INSTALLATION DETAILDIAGRAMMATICRECTANGULARDUCT PER PLANSROUND DUCTPER PLANSROUND DUCTPER PLANSTAPERED RECTANGULAR TO ROUNDDUCT TAKE-OFF BOOT FITTING.SCALE:3 VAV TERMINAL UNIT INSTALLATION DETAILDIAGRAMMATICHANGER RODS - 1/4"Ø UP TO300LBS. PER ROD, 3/8"Ø UPTO 600LBS. PER ROD.FLEXIBLECONNECTION.DUCTHANGERSTRAP. *(TYP.)FLEXIBLE CONNECTIONTO BE INSTALLEDAFTER FILTER BOX.MEDIUM PRESSUREFLEX DUCT.* INSTALL DUCT HANGER STRAP ADJACENT TO FLEX CONNECTION.RETURN FROM UNIT /PLENUM. TERMINATEWITH BIRD SCREENLOW PRESSURESUPPLY TO SPACE.MEDIUM PRESSURE DUCTFROM CENTRAL UNIT.VAV TERMINAL UNITSCALE:2 DIFFUSER CONNECTION DETAILDIAGRAMMATICFLEX DUCT. INSTALL IN FULLY EXTENDEDCONDITION FREE OF SAGS AND KINKS USINGMAXIMUM 5'-0" LENGTHS. SUPPORT AS REQUIRED.CONNECTION TO DUCTWORK PER 23 33 00.CINCH BANDS.INSTALL PER23 33 00.DIFFUSERCEILINGSSSSFLOOR LEVELP-1WALL1-1/2''VCOMBINATION WYEAND 1/8TH BEND1-1/2''V CONTINUES ON PLANSSWASTE SIZED PER PLAN,CONTINUES ON PLANLONGSWEEPELBOW2''W2 DFU1/2" HW1/2" CWHWT11/2" CWESCUTCHEONPLATE.3/4" CWINSTALLATION NOTE:UNIT SHALL BE MOUNTED UNDER SINKIN THE VERTICAL POSITION AS SHOWN.PROVIDE ADDITIONAL WALL BRACINGAS REQUIRED AND COORDINATE UNITMOUNTING BRACKET LOCATIONS WITHBRACING.SCALE:8TYPICAL WASTE RISER DIAGRAMDIAGRAMMATICSCALE:5TYPICAL INSTANT WATER HEATER PIPING DIAGRAMDIAGRAMMATICABOVE GRADE WASTECOVER AND SCREW.STAINLESS STEEL WALLEXTEND PIPING ASREQUIRED WHENINSTALLED IN BRICKAND VENT PIPE COUPLING.12" OR AS NOTED.BELOW GRADE WASTE1/8 C.I. BENDWASTE OR VENTMAY EXTEND AS AWALLPIPE COUPLING.FLOORCLEANOUTPLUGGEDTEE WITHAT METAL TRUSSAT WOOD TRUSSGALV.METAL SADDLEPIPE INSERTPER SPEC.PIPINGSTANDARD CLEVISASSEMBLYDOUBLE NUTALL THREADHANGER RODSDOUBLE NUTBOLT WITHDOUBLE NUT18" LOCKING WASHER (TYP.)PROVIDE BACKING BLOCKSCALE:6PIPE HANGER DETAILDIAGRAMMATICSCALE:7WALL CLEANOUT DETAILDIAGRAMMATICNOTE:PROVIDE RETURN BOOT FOR ALL GRILLES TRANSFERING AIR TO THE PLENUMSPACE.CEILING PLENUM1" ACOUSTICDUCTLINERDUCT STRAP (TYP.)90° ELBOWFULL SIZE DUCT TOMATCH GRILLE SIZEBIRDSCREENINTERIOR WALLCEILINGGRILLEDROPCEILINGSCALE:4TYPICAL GRILLE PLENUM TRANSFER THROUGH WALL INSTALLATION DETAILDIAGRAMMATICMACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM5.01MECHANICALDETAILS12/13 /2022 M6.01(VAV) FAN TERMINAL BOX SCHEDULEUNIT NOMANUFACTURERMODELAREA SERVEDLOCATIONUNIT SIZEPRIMARY AIR VALVEESP (INW.C.)HPELECTRICAL DATAREMARKSINLET DIAMETER(IN)COOLINGCFMHEATINGCFMKWVOLTSPHVAV-716PRICESDV5SMALL CONFERENCE 733A /733BSMALLCONFERENCE 733B-105702850.5--12012,4,7,8VAV-717PRICESDV5BREAK ROOM 739SECURE FILES 738-104602300.5--12012,4,7,8VAV-718PRICEFDCOFFICES 734A / 734BOFFICE 734B2105402700.51/24.027711,2,3,4,5,6,8VAV-719PRICESDV5RECEPTION 733 / OPEN OFFICE734OPEN OFFICE 734-105502750.5--12012,4,7,8VAV-720PRICEFDCOFFICE 735OFFICE 7354105602800.51/24.027711,2,3,4,5,6,8VAV-721PRICEFDCOPEN OFFICEOPEN OFFICE4128204100.51/25.027711,2,3,4,5,6,8VAV-722PRICEFDCOFFICE 736 / OPEN OFFICEOPEN OFFICE 7344105102550.51/24.527711,2,3,4,5,6,8VAV-723PRICESDV5CONFERENCE 737CONFERENCE 737-84002000.5--12012,4,7,8VAV-724PRICEFDCOPEN OFFICEOPEN OFFICE4128504250.51/25.527711,2,3,4,5,6,8NOTES FOR VAV BOX SCHEDULE1. PROVIDE UNIT WITH SINGLE POINT POWER CONNECTION.2. EC TO PROVIDE A MANUAL STARTER (INCLUDING DISCONNECT). MC TO PROVIDE AND INSTALL MOTOR RATED RELAY FOR INTERLOCK.3. PROVIDE UNIT WITH EC MOTOR.4. PROVIDE MINIMUM 3 DUCT DIAMETERS STRAIGHT RUN OF DUCT AT INLET SIZE UPSTREAM OF THE VAV BOX5. STATIC PRESSURE INCLUDES ONLY LOW PRESSURE SUPPLY DUCTWORK AND AIR TERMINALS DOWN STREAM OF FAN TERMINAL BOX.6. TERMINAL SHALL OPERATE AT A MINIMUM INLET STATIC PRESSURE OF 0.05" W.C.7. EC SHALL PROVIDE 120 VAC, 15 AMP CIRCUIT FOR VAV BOXES TO PANEL LOCATIONS SHOWN ON ELECTRICAL PLANS. EACH 120 VAC 15 AMP CIRCUIT SHALL POWER UP TO 20 CONTROLLERS. CONTROLS CONTRACTOR SHALL RUN WIRES AND CONDUIT FROM THIS LOCATION TOVAV BOX.8. UNIT TO BE PROVIDED UNDER BID ALTERNATE NO. 1.GRILLES, REGISTERS & DIFFUSERS SCHEDULEUNIT NOMANUFACTURERMODELDESCRIPTIONCFMAIR PATTERNMOUNTINGFACE SIZENECK SIZECOLORREMARKSCD-1TITUSTDC-1SUPPLY CEILING DIFFUSERPER PLANS1 WAYT-BAR23-3/4" X 23-3/4"PER PLANSWHITEFRAME 3CD-2TITUSTDC-2SUPPLY CEILING DIFFUSERPER PLANS2 WAYT-BAR23-3/4" X 23-3/4"PER PLANSWHITEFRAME 3CD-3TITUSTDC-3SUPPLY CEILING DIFFUSERPER PLANS3 WAYT-BAR23-3/4" X 23-3/4"PER PLANSWHITEFRAME 3CD-4TITUSTDC-4SUPPLY CEILING DIFFUSERPER PLANS4 WAYT-BAR23-3/4" X 23-3/4"PER PLANSWHITEFRAME 3RGTITUS50F-ARETURN/RELIEF GRILLEPER PLANS-T-BARNECK SIZE +1" TOTALPER PLANSWHITEPLUMBING FIXTURE SCHEDULEUNIT NOFIXTUREMOUNTINGMANUFACTURER AND MODEL NUMBERSWVHWCWREMARKSP-1SINGLE COMPARTMENTBREAKROOM SINK ADACOUNTERMOUNTSINK:FITTINGS:SUPPLIES:WASTE:TRAP:JUST SL-ADA-2231-A-GRCHICAGO FAUCETS 786-GN8AE29ABCPEBC LAH20-KCJUST J-ADA-35EBC TS1502"1-1/2"1/2"1/2"ADA COMPLIANT, PROVIDE WITH EBCINSTITUTIONAL ADA INSULATOR KIT.P-2APPLIANCE CONNECTIONWALLUNIT:GUY GRAY BIM875AB---1/2"PROVIDE WITH INTEGRAL WATERHAMMER ARRESTORWATER HEATER SCHEDULEUNIT NOMANUFACTURERMODELLOCATIONTYPEWETWEIGHT(LB)ELECTRICALSTARTERFURNISHED BYDISCONNECTFURNISHED BYREMARKSKWFLAVOLTSPHHWT-1EEMAXAM004277TBREAK ROOM 739ELECTRIC104.1152771MFREC1, 2NOTES FOR WATER HEATER SCHEDULE1. SINGLE POINT POWER CONNECTION. EC TO PROVIDE DISCONNECT2. SET TEMPERATURE AT 105°F.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM6.01MECHANICALSCHEDULES12/13 /2022 ABOVE FINISHED FLOORSYMBOLTHERMOSTAT (T'STAT)POINT OF CONNECTIONGENERAL CONTRACTORELECTRICAL CONTRACTORMECHANICAL CONTRACTORBELOW FINISHED FLOORSATEMPERATURE SENSORSUPPLY AIRRETURN AIRRATTTGCPOCECMCBFFAFFDESCRIPTIONDESCRIPTIONCONTROL LEGENDSYMBOLCSCURRENT SENSORCRCONTROL RELAY C.B.A.GENERAL:1.PROVIDE AND INSTALL ALL NECESSARY DEVICES, RELAYS, SWITCHES, SENSORS, DAMPERS,CONDUIT, AND WIRING TO PROVIDE A COMPLETE AND OPERATING DDC SYSTEM.2.THERMOSTATS SHALL PROVIDE 4°F OF ADJUSTABILITY TO THE OCCUPANT (2°F UP, 2°F DOWNFROM DDC SETPOINT).3.CONNECT TO EXISTING DDC SYSTEM - PROVIDE SCHEDULES BASED OFF OF EXISTING BUILDINGINFRASTRUCTURE. PROVIDE CONTROLS SEQUENCES TO MATCH EXISTING IN BUILDING.INTERLOCKS:1. PROVIDE ALL NECESSARY EQUIPMENT, DEVICES, WIRING AND PROGRAMMING FOR INTERLOCKOF EQUIPMENT AS SHOWN ON THE EQUIPMENT SCHEDULES.TRACK EMCS CHANGES:2.EMCS SHALL RECORD SOFTWARE CHANGES AND USER LOGIN NAME FROM BEGINNING OFINSTALLATION.PRIMARY AIRMISCELLANEOUS CONTROLSCONTROLS CONTRACTORCCVARIABLE EMCS VALUEVARPACONTROL BY EMCSUNITCONTROLLERPAAFMSATSPACEOSSPACECO2SPACEHEATINGCOILGENERAL1.VAV BOX SHALL BE CONTROLLED AND ENERGIZED AS SCHEDULED BY THEBUILDING EMCS.2.SPACE TEMPERATURE SENSORS SHALL BE EQUIPPED WITH PUSH BUTTONS TOPROVIDE UNOCCUPIED OVERRIDE REQUEST. OVERRIDE RUNTIME SHALL BE 2HOURS (VAR).OCCUPIED MODE1.VAV BOX SHALL BE CONSIDERED AS RUNNING CONTINUOUSLY AND PRIMARY AIRDAMPER SHALL REMAIN AT MINIMUM POSITION AS REQUIRED FOR VENTILATION.2.UPON CALL FOR COOLING AS SENSED BY THE SPACE THERMOSTAT, THE PRIMARYAIR DAMPER SHALL MODULATE TO MAINTAIN COOLING SETPOINT.3.UPON CALL FOR HEATING AS SENSED BY THE SPACE THERMOSTAT:A.PRIMARY AIR DAMPER SHALL MODULATE TO THE MINIMUM HEATING POSITION.OCCUPANCY SENSOR OVERRIDE1.WHERE PROVIDED, OCCUPANCY SENSOR SHALL OVERRIDE VAV BOX OCCUPIEDMODE WHEN SPACE IS UNOCCUPIED:A.PRIMARY AIR DAMPER SHALL CLOSE.B.SPACE TEMPERATURE SETPOINT SHALL BE RESET.DEMAND CONTROLLED VENTILATION1.WHERE PROVIDED, PRIMARY AIR DAMPER SHALL MODULATE TO MAINTAIN SPACECO2 SETPOINT OF 1000 PPM (VAR).2.GENERATE ALARM IF SPACE CO2 SENSOR FAILS.3.GENERATE ALARM IF CO2 LEVEL RISES 10% (VAR) ABOVE SETPOINT.AIRFLOW MONITOR1.MONITOR PRIMARY AIRFLOW AND REPORT TO EMCS.SPACE TEMPERATURE SETPOINTS1.TEMPERATURE SETPOINT SHALL BE 70°F HEATING (VAR) AND 75°F COOLING (VAR).2.TEMPERATURE SETPOINTS SHALL BE RESET TO 5°F LESS IN HEATING AND 5°FGREATER IN COOLING WHEN THE OCCUPANCY SENSOR (WHERE PROVIDED)INDICATES THAT THE SPACE IS UNOCCUPIED.3.NIGHT SETBACK TEMPERATURE SETPOINT SHALL BE 55°F HEATING (VAR) AND 85°FCOOLING (VAR).INFORMATION AT THE TERMINAL·SPACE TEMPERATURE·SPACE TEMPERATURE SETPOINT·UNIT COMMANDED MODE (OCCUPIED/UNOCCUPIED, OCCUPANCY SENSOROVERRIDE)·SUPPLY AIR TEMPERATURE·DAMPER POSITION (% COMMANDED OPEN)·HEATING STATUS (% COMMANDED OPEN)·PRIMARY AIRFLOW CFM·SPACE CO2 LEVEL·SPACE CO2 SETPOINT·SPACE CO2 ALARM·ALL EMCS GENERATED ALARMS·ALL SETPOINTS AND RANGESTTELECTRIC(WHERE PROVIDED FORLIGHTING CONTROL ORON PLANS)(WHERESHOWN)GENERAL1.THE TERMINAL UNIT SHALL BE CONTROLLED AND ENERGIZED AS SCHEDULED BY THE BUILDING DDC SYSTEM.OCCUPIED MODE1.THE UNIT SHALL BE CONSIDERED AS RUNNING CONTINUOUSLY AND AIRFLOW DAMPER SHALL MODULATE TOMAINTAIN MAXIMUM CFM AS INDICATED ON THE EQUIPMENT SCHEDULE.UNOCCUPIED MODE1.THE AIRFLOW DAMPER SHALL BE CLOSED.CO2 SENSORS1.MODULATE CFM SETPOINT FROM SCHEDULED MAXIMUM CFM TO MINIMUM CFM TO MAINTAIN SPACE CO2 SETPOINTOF 1000 PPM (VAR). GENERATE ALARM IF CO2 RISES 10% ABOVE SETPOINT (VAR).OCCUPANCY SENSORS1.CLOSE AIRFLOW DAMPER WHEN ROOM IS UNOCCUPIED. RESUME CO2 CONTROL AFTER THE SPACE HAS BEENREOCCUPIED FOR 5 CONSECUTIVE MINUTES (VAR).INFORMATION AT TERMINAL:·UNIT COMMANDED MODE (OCCUPIED/UNOCCUPIED).·DAMPER POSITION (% COMMANDED OPEN).·AIRFLOW CFM·CO2 LEVELCONTROL BY EMCSUNITCONTROLLERPAA. SPACEB.C.D.E.AFMSACO2SPACEOCCF.·CO2 SETPOINT·CO2 ALARM·OCCUPANCY SENSORVARIABLE-SUPPLY VAV TERMINAL BOX (VAV-716, 717, 719, 723)(WHERE PROVIDED FOR LIGHTINGCONTROL OR ON PLANS)A.B.C.D.E.F.G.VAV TERMINAL WITH ELECTRIC REHEAT (VAV-718, 720, 721, 722, 724)MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateRKKCM7.01MECHANICALCONTROLS12/13 /2022 SYMBOLDESCRIPTIONSYMBOLDESCRIPTIONRECESSED LIGHT FIXTURESURFACE OR RECESSED LIGHT FIXTUREEGRESS FIXTURE WITH EMERGENCY BATTERY PACK. PROVIDE UNSWITCHED HOT LEG.EXIT LIGHT FIXTURE (PROVIDE DIRECTION ARROWS AS INDICATED) PROVIDE UNSWITCHED HOT LEG.WALL MOUNTED EXIT LIGHT FIXTURE (PROVIDE DIRECTION ARROWS AS INDICATED) PROVIDE UNSWITCHED HOT LEG.DUPLEX RECEPTACLE - MOUNT AT +18" UNLESS NOTED OTHERWISE (E INDICATES EXISTING TO BE REPLACED)DUPLEX RECEPTACLE - MOUNT AT +18" UNLESS NOTED OTHERWISE (G INDICATES GROUND FAULT CIRCUIT INTERRUPTER)DUPLEX RECEPTACLE - MOUNT AT +18" UNLESS NOTED OTHERWISE (C INDICATES ABOVE COUNTER)FOURPLEX RECEPTACLE - MOUNT AT +18" UNLESS NOTED OTHERWISEGROUNDING SYSTEM PER CODEJUNCTION BOX - SIZE PER CODE (F INDICATES MODULAR FURNITURE CONNECTION, LV INDICATES LOW VOLTAGE)DISCONNECT SWITCHFUSED DISCONNECT SWITCHCOMBINATION DISCONNECT / MAGNETIC MOTOR STARTEREXISTING PANELBOARD TO BE RETAINEDMAIN DISTRIBUTION BOARDENCLOSED CIRCUIT BREAKER, AMPERES AS INDICATEDCONSTRUCTION NOTESDEMOLITION NOTESALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINEDALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVEDGC 11SINGLE POLE SWITCH. MOUNT AT +48" UNLESS NOTED OTHERWISE.SINGLE POLE LOW VOLTAGE SWITCHCOMBINATION SWITCH / OCCUPANCY SENSOR. MOUNT AT +48" UNLESS NOTED OTHERWISE.THREE WAY SWITCH. MOUNT AT +48" UNLESS NOTED OTHERWISE.MULTI-GANGED SWITCH. MOUNT AT +48" UNLESS NOTED OTHERWISE. (LOWER CASE LETTERS INDICATES SWITCHING)PHOTOCELL CONTROLCEILING MOUNTED OCCUPANCY SENSOR (LIGHTING CONTROL)baPCLVOS3OSJCEILING MOUNTED, DATA OUTLET - WITH (1) DATA PORT AND (1) CAT6A CABLE. MAINTAIN THE COMMUNICATION/ DATA OUTLETREQUIREMENTS.EXISTING TELEPHONE OUTLETC#COMMUNICATION / DATA OUTLET - WALL MOUNT WITH (2) DATA PORTS AND (2) CAT6 CABLES (4/S BOX WITH SINGLE GANGMUDRING AND COVER PLATE) 1"C. TO ACCESSIBLE CEILING SPACE, MOUNT AT +18" AFF UNLESS NOTED OTHERWISE. (CINDICATES MOUNTED ABOVE COUNTER, #INDICATES QUANTITY OF DATA PORTS AND CABLES, IF DIFFERENT THAN 2, FINDICATES FURNITURE OUTLET).CEILING MOUNTED OCCUPANCY SENSOR AND PHOTOCELL (LIGHTING CONTROL)OPDUPLEX RECEPTACLE - MOUNT AT +18" UNLESS NOTED OTHERWISE (S INDICATES SWITCHED/CONTROLLED)SHDMIEXISTING TV HDMI CONNECTIONSEXISTING TWO POST 19" DATA RACK - FLOOR MOUNTACPACCESS CONTROL PANEL. REFER TO ACCESS CONTROL DETAILS FOR MORE INFORMATION. ACPSACCESS CONTROL POWER SUPPLY. REFER TO ACCESS CONTROL DETAILS FOR MORE INFORMATION. CRPROXIMITY CARD READER - WALL MOUNT AT +48" AFF. PROVIDE SINGLE-GANG BOX FLUSH TO WALL. SEE ARCHITECTURAL FOREXACT MOUNTING HEIGHT AND LOCATION. REFER TO ACCESS CONTROL DETAILS FOR MORE INFORMATION.DDOOR POSITION SWITCH (A DPDT SHALL BE PROVIDED AT EACH LOCATION SHOWN FOR BOTH THE INTRUSION ALARM SYSTEMAND ACCESS CONTROL SYSTEM). PROVIDED AND INSTALLED BY THE ACCESS CONTROL SYSTEM INSTALLING VENDOR.COORDINATE WITH ALL TRADES, AS REQUIRED. PROVIDE GRI; MODEL # 199-12WG.EDREXREQUEST TO EXIT MOTION SENSOR. REFER TO ACCESS CONTROL DETAILS FOR MORE INFORMATION. ELECTRIFIED EXIT DEVICE. SEE DIVISION 8 SPECIFICATIONS FOR EXACT HARDWARE TO BE USEDAT EACH LOCATION. REFER TO ACCESS CONTROL DETAILS FOR MORE INFORMATION.TVEXISTING CABLE TV COAX OUTLETSFIRE ALARM / EMERGENCY COMMUNICATION SPEAKER STROBE - WALL MOUNTEDSTCEILING-MOUNTED STROBEFIRE ALARM / EMERGENCY COMMUNICATION HORN STROBE - WALL MOUNTEDFAPSFIRE ALARM / EMERGENCY COMMUNICATION NAC PANEL - EDWARDS SIGNALINGDUPLEX RECEPTACLE (TV INDICATES MONITOR POWER MOUNTED AT +60" AFF)TVPRIMARY DAYLIGHT ZONESECONDARY DAYLIGHT ZONEBASE BID: UNDER BASE BID, THE HVAC SYSTEM AND ASSOCIATED CONTROLS AREEXISTING TO REMAIN.ALTERNATE BID NO. 1: UNDER ADDITIVE ALTERNATE, PROVIDE ALL MECHANICALCONNECTIONS, EQUIPMENT, AND ASSOCIATED APPURTENANCES DETAILED IN THEELECTRICAL PLANS AND SPECIFICATIONS. COORDINATE WITH THE MECHANICALCONTRACTOR PRIOR TO STARTING WORK. SEE EACH PLAN SHEET FOR ADDITIONALINFORMATION.ALTERNATE BID NO. 1 SCOPE OF WORKBASE BID: PROVIDE ALL LIGHTING, CONTROLS, AND ASSOCIATED APPURENTANCESDETAILED IN THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR RECEPTION 733,SECURE FILES 738, AND BREAK ROOM 739 ONLY.ALTERNATE BID NO. 2: UNDER ADDITIVE ALTERNATE, PROVIDE ALL LIGHTING,CONTROLS, AND ASSOCIATED APPURENTANCES FOR ALL SPACES IN PROJECT SCOPE,AS DETAILED IN THE ELECTRICAL DRAWINGS. SEE EACH PLAN SHEET FOR ADDITIONALINFORMATION.ALTERNATE BID NO. 2 SCOPE OF WORKMACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHELECTRICALLEGENDE0.0112/2/202212/13 /2022 1.THE FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM SHALL BE FULLY FUNCTIONAL WITHOUTTHE USE OF PRIMARY POWER. THE FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM SHALL BEPROVIDED WITH A MINIMUM OF 24 HOURS OF STANDBY OPERATION FOLLOWED BY AN ADDITIONAL 5MINUTES OF ALARM OPERATION.2.ALL BATTERIES SHALL PROVIDE AT LEAST 25% SPARE CAPACITY.3.THE FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM CONTROL PANEL (FACP) IS AN EXISTINGEDWARDS SIGNALING AND MAY INCLUDE INTERNAL POWER SUPPLIES. PROVIDE ADDITIONALQUANTITIES OF POWER SUPPLIES AS REQUIRED FOR A COMPLETE AND FULLY FUNCTIONAL SYSTEM.THE FIRE ALARM SYSTEM CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THEELECTRICAL CONTRACTOR FOR ALL POWER CONNECTIONS THE FIRE ALARM SYSTEM CONTRACTORSHALL BE RESPONSIBLE FOR THE ELECTRICAL COSTS ASSOCIATED WITH ALL NON-COORDINATEDPOWER CONNECTIONS.4.PROVIDE 25% SPARE CAPACITY FOR NOTIFICATION POWER SUPPLIES.5.PROVIDE MULTIPLE INITIATING DEVICE CIRCUITS SO THAT FAILURE OF ONE CIRCUIT DOES NOTCAUSE THE FACILITY TO LOSE OVER 50% OF ITS DETECTION CAPABILITY PER FLOOR.6.EACH CIRCUIT SHALL HAVE A MAXIMUM OF 20 DEVICES PER ZONE.7.PROVIDE BATTERY CALCULATIONS FOR ALL FIRE ALARM / EMERGENCY COMMUNICATION SYSTEMS.1.ALL INITIATING AND NOTIFICATION CIRCUITS SHALL BE "CLASS B" WIRING.2.ALL "CLASS B" WIRING CIRCUITS SHALL BE PROVIDED WITH AN "END-OF-LINE" RESISTOR INSTALLEDAT THE END OF EACH CIRCUIT.3.THE USE OF T-TAPPING IS NOT ALLOWED ON I.D.C. (INITIATING DEVICE CIRCUIT) CIRCUITS. T-TAPPINGIS NOT ALLOWED ON ANY CIRCUIT REQUIRING AN END OF LINE RESISTOR.4.ALL WIRE TERMINATIONS SHALL BE BY USE OF WIRE NUTS OR SCREW TYPE TERMINATION BLOCKS.5.THE USE OF CRIMPED CONNECTORS, TWISTING OF WIRES, ETC. SHALL NOT BE ALLOWED IN J-BOXES,TERMINAL CABINETS, OR ENCLOSURES.6.ALL WIRES OUTSIDE OF J-BOXES, TERMINAL CABINETS, OR ENCLOSURES SHALL BE FREE OF SPLICES.7.CONDUITS SHALL BE CONCEALED IN CEILING SPACES, WALLS, AND OTHER AREAS WHEREVERPOSSIBLE.8.ALL CONDUIT SHALL BE INSTALLED IN A PARALLEL OR PERPENDICULAR FASHION THAT IS TIGHT TOSTRUCTURE. THE CONTRACTOR SHALL COORDINATE ALL CONDUIT ROUTING WITH OTHER TRADES.9.FIRE ALARM / EMERGENCY COMMUNICATION CABLING INSTALLED ABOVE ACCESSIBLE CEILINGSSHALL BE ALLOWED TO BE INSTALLED AS OPEN CABLING. PROVIDE "D" RING HANGER FOR ALL OPENCABLING AT A MAXIMUM SPACING OF 5'-0" ON CENTER.10.CABLING THAT IS INSTALLED IN WALLS, CABLING THAT IS INSTALLED BELOW 8'-0" IN ELEVATION THATIS SUBJECT TO DAMAGE, AND CABLING THAT IS INSTALLED ABOVE INACCESSIBLE CEILINGS SHALL BEINSTALLED IN CONDUIT.11.CONDUITS PASSING THROUGH BUILDING EXPANSION JOINTS OR BUILDING SEISMIC JOINTS SHALLHAVE JUNCTION BOXES AT EACH SIDE OF THE EXPANSION / SEISMIC JOINT. PROVIDE SECTION OFFLEXIBLE CONDUIT BETWEEN JUNCTION BOXES AND GROUNDING BUSHINGS WITH #12 GROUNDINGCABLE TO MAINTAIN CONTINUITY BETWEEN ALL (2) JUNCTION BOXES. PROVIDE FLEX CONDUIT ANDGROUNDING CABLE OF SUFFICIENT LENGTH TO ACCOMMODATE THE CALCULATED BUILDINGMOVEMENT PLUS 6" OF ADDITIONAL MOVEMENT. PROVIDE QUANTITIES AS REQUIRED.12.ALL EXPOSED SURFACE MOUNTED RACEWAYS IN FINISHED SPACES BELOW 8'-0" IN ELEVATION SHALLBE A MINIMUM OF SERIES 700 METAL WIREMOLD OR EQUAL. THE INSTALLATION OF EXPOSEDELECTRICAL METALLIC TUBING (EMT) IN FINISHED SPACES BELOW 8'-0" IN ELEVATION WILL NOT BEALLOWED.13.CONDUITS SHALL NOT EXCEED FILL RATING OF 40% AS DEFINED BY THE LATEST ADOPTED EDITION OFTHE NATIONAL ELECTRICAL CODE (N.F.P.A. #70). PROVIDE SIZES AND QUANTITIES AS REQUIRED.14.WHERE EXPOSED TO VIEW IN FINISHED SPACES, PAINT ALL NEW CONDUITS, MOUNTING HARDWARE,AND RACEWAYS TO MATCH THE ADJACENT SURFACES.15.ALL NEW FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM JUNCTION BOXES SHALL BE PAINTEDRED AND ANNOTATED "FIRE ALARM POWER LIMITED" ON THE COVER IN BLACK BOLD PRINT HAVINGMINIMUM CHARACTER FONT SIZE ¼" TALL X ¼" WIDE.1.THE FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM CONTRACTOR SHALL PERFORM AUDIBILITYTESTING IN EACH SPACE OF THE BUILDING PRIOR TO ACCEPTANCE TESTING. DOCUMENTATION OFDECIBEL (dB) VALUES RECORDED IN ALL SPACES SHALL BE PROVIDED TO THE ARCHITECT / ENGINEERPRIOR TO ACCEPTANCE TESTING.A.DECIBEL READINGS SHALL BE TAKEN AT A POINT 10'-0" FROM THE APPLIANCE AT AN ELEVATIONOF 5'-0" ABOVE FINISHED FLOOR.B.THE SOUND LEVEL SHALL BE A MINIMUM OF 15 DECIBELS (dBs) ABOVE THE AVERAGE AMBIENTSOUND LEVEL.C.THE SOUND LEVEL SHALL BE A MAXIMUM OF 30 DECIBELS (dBs) ABOVE THE AVERAGE AMBIENTSOUND LEVEL.D.THE SOUND LEVEL SHALL BE A MINIMUM OF 5 DECIBELS (dBs) ABOVE THE MAXIMUM SOUNDLEVEL HAVING A MINIMUM DURATION OF 60 SECONDS.IN SPACES THAT DO NOT MEET THE MINIMUM AUDIBLE (dB) VALUES, THE FIRE ALARM SYSTEMCONTRACTOR SHALL PROVIDE ADDITIONAL AUDIBLE NOTIFICATION APPLIANCES UNTIL THEMINIMUM DECIBEL (dB) VALUES ARE OBTAINED.2.THE FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM CONTRACTOR SHALL PERFORM AUDIBILITYTESTING IN EACH SPACE OF THE BUILDING PRIOR TO ACCEPTANCE TESTING. DOCUMENTATION OFDECIBEL (dB) VALUES RECORDED IN ALL SPACES SHALL BE PROVIDED TO THE ARCHITECT / ENGINEERPRIOR TO ACCEPTANCE TESTING.A.COMMON INTELLIGILIBITY SCALE (C.I.S.) MEASUREMENTS SHALL BE TAKEN WHEN THE AREA ISOCCUPIED AND WHEN THE AMBIENT SOUND LEVELS ARE AT OR NEAR THE EXPECTED MAXIMUM.B.COMMON INTELLIGILIBITY SCALE (C.I.S.) MEASUREMENT POINTS IN EACH ACOUSTICALLYDISTINGUISHABLE SPACE (A.D.S.) SHALL BE BASED UPON THE AREA, VOLUME, SPEAKERAPPLIANCE LOCATION, LOCATION OF NOISE SOURCES, EGRESS PATH, LOCATION OF PERSONNELIN THE SPACE, ETC.C.COMMON INTELLIGILIBITY SCALE (C.I.S.) MEASUREMENTS SHALL BE TAKEN AT AN ELEVATION OF5'-0" ABOVE THE FINISHED FLOOR OR AT AN ELEVATION DEEMED APPROPRIATE BASED UPONOCCUPANCY (CHILD HEIGHT, SITTING AREA, WORK AREA, ETC.) AND APPROVED BY THEARCHITECT / ENGINEER PRIOR TO TESTING.D.MULTIPLE MEASUREMENT POINTS IN AN ACOUSTICALLY DISTINGUISHABLE SPACE (ADS) SHALLBE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 40'-0".E.NO MORE THAN 1/3 OF THE MEASUREMENT POINTS WITHIN AN ACOUSTICALLY DISTINGUISHABLESPACE (A.D.S) SHALL BE ON THE AXIS OF THE SPEAKER.F.MEASUREMENT POINTS SHALL BE INDICATED ON THE AS-BUILT DRAWINGS.G.THE COMMON INTELLIGILIBITY SCALE (C.I.S.) VALUES SHALL BE DOCUMENTED TO TWO DECIMALPLACES.H.THE INTELLIGIBILITY OF AN EMERGENCY COMMUNICATIONS SYSTEM IS CONSIDEREDACCEPTABLE IF AT LEAST 90% OF THE MEASUREMENT LOCATIONS WITHIN EACH ACOUSTICALLYDISTINGUISHABLE SPACE (ADS) HAVE A MEASURED COMMON INTELLIGILIBITY SCALE (C.I.S.) OF0.65 AND AN AVERAGE COMMON INTELLIGILIBITY SCALE (C.I.S.) OF AT LEAST 0.70.I.IN SPACES THAT DO NOT MEET THE MINIMUM COMMON INTELLIGILIBITY SCALE (C.I.S.), THE FIREALARM / EMERGENCY COMMUNICATION SYSTEM CONTRACTOR SHALL PROVIDE ADDITIONALAUDIBLE NOTIFICATION APPLIANCES OR ADJUST THE LOCATION AND/OR TAP SETTINGS OFAUDIBLE NOTIFICATION APPLIANCES UNTIL THE MINIMUM C.I.S. VALUES ARE OBTAINED.FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM CABLINGAND CONDUIT REQUIREMENTS1.PROVIDE ALL MATERIALS, EQUIPMENT, LABOR, DESIGN AND PROGRAMMING FOR THEMODIFICATION OF AN EXISTING COMPLETE, ADDRESSABLE LOW VOLTAGE 24 VOLT D.C., FULLYOPERATIONAL EDWARDS SIGNALING BRAND FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM.ALL EQUIPMENT PROVIDED FOR THIS PROJECT SHALL BE NEW, CURRENTLY MANUFACTURED, ANDSHALL BE DELIVERED TO THE PROJECT SITE WITH THE ORIGINAL FACTORY SEAL INTACT.MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENTS OF THE LATESTEDITION OF THE NATIONAL ELECTRICAL CODE (N.F.P.A. #70), NATIONAL FIRE ALARM AND SIGNALINGCODE (N.F.P.A. #72), THE LAWS AND REGULATIONS OF WASHINGTON STATE, THE CITY OF RENTONMUNICIPAL CODE.1.1.THE NICET DESIGNER SHALL BE RESPONSIBLE FOR DESIGN, LAYOUT, AND COORDINATION OFSMOKE DETECTION COVERAGE IN ALL CONCEALED SPACES PER NFPA #721.2.REMOVE, RELOCATE, ADD, OR REPLACE AS NECESSARY TO ACCOMMODATE THE CHANGESFROM THE TENANT IMPROVEMENT WITHIN THE AREA OF WORK ONLY.1.3.SHOP DRAWINGS1.3.1.PREPARE DETAILED WORKING DRAWINGS FOR THE SYSTEM LAYOUT IN ACCORDANCEWITH N.F.P.A. #72 AND THE FOLLOWING:1.3.1.1.SHOP DRAWING REQUIREMENTS: THE INSTALLING VENDOR'S/CONTRACTOR'SCOMPLETE AND FULL-SIZE SET OF SHOP DRAWINGS SHALL BE ISSUED IN THEFOLLOWING FORMAT:a.THEY SHALL BE CLEAR AND LEGIBLE.b.THE SAME SHEET SIZE AS THE CONTRACT DRAWINGS (I.E. 22” X 34”).c.A MINIMUM OF 1/8” TEXT HEIGHT SHALL BE USED FOR ALL TEXT, SYMBOL TEXT, ANDSUBSCRIPT TEXT.d.SCALE OF DRAWINGSi.a.ANY SITE PLAN DRAWINGS SHALL BE THE SAME SCALE AS ISSUED IN THE CONTRACTDOCUMENTS.ii.b.FLOOR PLAN DRAWINGS SHALL BE 1/8”=1'-0”, UNLESS DIRECTED TO DO OTHERWISE.ij.THE ELECTRICAL LEGEND, WIRE LEGEND, LOAD AND BATTERY CALCULATIONS, RISERDIAGRAM, SEQUENCE OF OPERATION INFO, WIRING DETAILS, AND MOUNTINGDETAILS SHALL PRECEDE THE SITE PLANS AND FLOOR PLANS.ik.ALL SHEETS, INCLUDING THE COVER, SHALL INCLUDE A TITLE BLOCK ALONG THEEDGE OF EACH OF THE DRAWINGS THAT, WHEN THE DRAWINGS ARE ROLLED UP, THEFOLLOWING INFORMATION SHALL BE VISIBLE:il.THE SYSTEM-SPECIFIC SHEET NUMBERim.PROJECT NAME, SPECIFICATION SECTION NUMBER AND SECTION TITLE NAMEin.FLOOR NAME, AREA, AND/OR SECTION OF THE BUILDING (USE THE NAME OF THEAREA AND/OR FLOOR DESCRIPTION THAT IS ON THE CONTRACT DRAWINGS.)io.ARCHITECTURAL INFORMATION ON THE CONTRACT DRAWINGS SHALL BE INCLUDEDON THE INSTALLING VENDOR'S/CONTRACTOR'S SHOP DRAWINGS, INCLUDING, BUTNOT LIMITED TO: MATCH LINES, GRID LINES, GRID BUBBLES, KEY PLAN, ANDENLARGED FLOOR PLANS.2.COORDINATE EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL WALL MOUNTED DEVICES WITHARCHITECTURAL ELEVATIONS AND EXISTING CONDITIONS.3.CORE DRILLED HOLES SHALL NOT PENETRATE THROUGH ANY STRUCTURAL BEAMS, REBARCONCRETE SLABS, AND / OR WALLS THAT MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THEBUILDING.4.WHEN PENETRATING FIRE RATED WALLS, FLOORS, OR CEILINGS, THE CONTRACTOR SHALL UTILIZEAPPROVED FIRE RATED PENETRATION METHODS. THE FIRE RATING OF THE WALLS, FLOORS, ORCEILINGS SHALL BE MAINTAINED AFTER THE CONDUIT HAS BEEN INSTALLED.5.PRIOR TO ROUGH-IN, COORDINATE EXACT LOCATIONS OF FIRE ALARM / EMERGENCYCOMMUNICATION APPLIANCES AND DEVICES WITH THE GENERAL ELECTRICAL, MECHANICAL, ANDFIRE PROTECTION CONTRACTORS.6.THE GENERAL CONTRACTOR AND FIRE ALARM / EMERGENCY COMMUNICATION SYSTEMCONTRACTOR SHALL COORDINATE ALL CUTTING, PATCHING AND FINISH WORK.7.ALL DEVICES AND DETECTOR BASES SHALL BE PERMANENTLY AND CLEARLY LABELED WITH THEDEVICE ZONE AND DEVICE NUMBER IN CIRCUIT IN A READILY VISIBLE LOCATION DIRECTLY ON THEDEVICE.FIRE ALARM / EMERGENCY COMMUNICATION SYSTEM GENERAL NOTESFIRE ALARM SYSTEM / EMERGENCY COMMUNICATIONAUDIBILITY AND INTELLIGIBILITY REQUIREMENTSFIRE ALARM / EMERGENCY COMMUNICATION SYSTEMEQUIPMENT REQUIREMENTSMACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHELECTRICALGENERALNOTESE0.0212/2/202212/13 /2022 1.SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR SHEET.2.CONTRACTOR SHALL MOUNT DEVICES AND ROUTE CONDUIT SO AS NOT TO INTERFERE WITH THE STRUCTURAL INTEGRITY OFTHE WALL.3.ALL CONDUITS MUST BE A MINIMUM OF 6'-6" ABOVE ALL MECHANICAL EQUIPMENT AND MECHANICAL CLEARANCE SPACES. E.C.WILL BE RESPONSIBLE TO MOVE ANY CONDUITS WHICH DO NOT COMPLY.4.NO CONDUITS ARE ALLOWED TO BE ROUTED ON TOP OF THE ROOF.5.REVIEW ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF AREAS WITH ACCESSIBLE CEILING TILES, GWB, ANDOPEN CEILINGS. PROVIDE MANUFACTURER APPROVED BACK BOXES IN AREAS WITH CEILINGS THAT ARE OPEN TOSTRUCTURE. ROUTE CONDUIT ON TOP OF ROOF DECK UNDER INSULATION TO CONCEAL. UTILIZE RIGID GALVANIZED STEELCONDUIT. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH HVAC CONTRACTOR AND T-BAR CEILING INSTALLER PRIOR TOINSTALLATION.6.ROOMS AND/OR AREAS WITHOUT CEILINGS SHALL HAVE ALL CABLES ROUTED IN CONDUIT. CONDUIT SHALL BE INSTALLEDTIGHT TO STRUCTURE, ROUTED PARALLEL OR PERPENDICULAR TO STRUCTURE, AND SHALL BE PAINTED TO MATCH ADJACENTSURFACE.7.ALL OUTLETS, SWITCHES AND DEVICES MOUNTED BACK TO BACK IN A WALL, MUST BE SPACED A MINIMUM OF 24" APART ORFURNISHED WITH SOUND ATTENUATING MASTIC AROUND BOX TO MEET ACOUSTICAL REQUIREMENTS.8.E.C. SHALL PROVIDE ALL REQUIRED CONDUCTORS/WIRES TO ALL DEVICES AS NECESSARY IN ORDER TO INSTALL ALLCIRCUITS, SWITCHING AND GROUNDING COMPLETE. PANEL CIRCUIT NUMBERS ARE SHOWN TO CLARIFY CIRCUITINGCONFIGURATION.9.FEED THROUGH GFCI RECEPTACLES SHALL NOT BE USED.10.WHEN PENETRATING FIRE RATED WALL, FLOORS, OR CEILINGS, THE CONTRACTOR SHALL UTILIZE FIRE RATED PENETRATIONMETHODS. THE FIRE RATING OF THE PENETRATION SHALL BE MAINTAINED AFTER THE CONDUIT OR WIREWAY HAS BEENINSTALLED. FIRE CAULK ALL PENETRATIONS AS REQUIRED.11.ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS THROUGHOUT THIS PROJECT, UNLESSNOTED OTHERWISE.12.SEE ALL DETAIL SHEETS AND RISER DIAGRAMS FOR ADDITIONAL WORK. ALL DETAILS AND RISERS ARE APPLICABLE TO THISPROJECT WHETHER REFERENCED OR NOT.13.GROUNDING SHALL CONFORM TO NEC 250.14.CIRCUITING SHALL BE PROVIDED AS REQUIRED TO MEET THE NEC. ALL SINGLE POLE CIRCUITS SHALL BE PROVIDED WITHDEDICATED NEUTRALS UNLESS NOTED OTHERWISE. EACH LOW VOLTAGE LIGHTING CONTROL HOMERUN SHALL BE PROVIDEDWITH THE REQUIRED NUMBER OF CONDUCTORS FOR EACH SWITCH LEG THAT IT SERVES.15.MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENT OF THE LATEST EDITION OF THE NATIONALELECTRICAL CODE (N.F.P.A. #70), THE LAWS AND REGULATION OF WASHINGTON STATE, AND THE CITY OF RENTON. ALL WORKAND MATERIAL TO BUILDING STANDARDS AND CODE UNLESS NOTED OTHERWISE.16.ALL CIRCUIT EXTENSIONS AND NEW RACEWAYS SHALL BE CONCEALED. NOTIFY OWNER FOR APPROVAL PRIOR TOINSTALLATION OF ANY SURFACE MOUNTED RACEWAY WHERE CONCEALMENT IS NOT POSSIBLE.17.CORE DRILL EXISTING WALL, CUT, PATCH AND PAINT TO MATCH EXISTING CONDITIONS AS REQUIRED TO CONCEAL ALL NEWCIRCUITS. ELECTRICAL CONTRACTOR TO REPAIR ANY DAMAGE DONE DURING CONSTRUCTION. CORE DRILLED HOLES SHALLNOT PENETRATE THROUGH ANY EXISTING REBAR AND/OR CONDUIT CONTAINED IN THE EXISTING CONCRETE SLAB ANDWALLS. CORE DRILL LOCATIONS MAY NEED TO BE MODIFIED TO ACCOMMODATE EXISTING OBSTRUCTIONS CONTAINED WITHINTHE FLOOR AND WALLS. DO NOT CORE DRILL A STRUCTURAL BEAM OR MODIFY THE STRUCTURAL INTEGRITY OF THEBUILDING.18.PROVIDE CUT-IN BOX AND FISH MC CABLE IN WALL TO NEW DEVICE FROM ABOVE ACCESSIBLE CEILING. CUT AND PATCH ASREQUIRED. WHERE DEVICE IS LOCATED ON AN OUTSIDE WALL, PROVIDE SURFACE METAL RACEWAY ROUTED TO ACCESSIBLECEILING SPACE.19.CUT AND PATCH AREAS WITH EXISTING GYP WALL AND CEILING TO FACILITATE NEW LIGHTING AND RECEPTACLE CIRCUITS.20.THIS BUILDING UTILIZES POST TENSION SLABS BETWEEN FLOORS. GC TO X-RAY FLOOR PRIOR TO ANY PENETRATIONS.GENERAL CONSTRUCTION NOTES (APPLY TO ALL SHEETS)1.THESE PLANS DELINEATE THE BASIC SCOPE OF WORK FOR THE REMOVAL OF EXISTING MATERIAL. THE DEMOLITION DRAWINGSAND NOTES ARE PROVIDED WITH THE INTENT TO GENERALLY DESCRIBE AREAS AND LIMITS OF WORK. THE CONTRACTORSHALL BE FAMILIAR WITH THE SITE AND CONDITIONS THERE AND SHALL NOT RELY SOLELY ON REVIEW OF THE BIDDINGDOCUMENTS IN DETERMINING THE EXTENT OF DEMOLITION WORK REQUIRED. COORDINATION OF THESE DRAWINGS WITHREQUIREMENTS FOR CONTRACT WORK IS THE RESPONSIBILITY OF THE CONTRACTOR. DISCREPANCIES BETWEEN OR WITHINTHE CONTRACT DOCUMENTS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. THE CONTRACTOR SHALL PROVIDECLARIFYING SKETCHES, DIAGRAMS, AND FIELD DIMENSIONS OF EXISTING CONDITIONS AT THE REQUEST OF THE ENGINEERIF/WHEN CONFLICTS ARE IDENTIFIED.2.IT IS THE CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN THEIR BID ALL COSTS ASSOCIATED WITH NECESSARY DEMOLITIONTO ALLOW NEW CONSTRUCTION SHOWN IN CONTRACT DOCUMENTS, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALLREMOVE ALL EXISTING ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, DEVICES, ABANDONED RACEWAYS AND CONDUCTORS,TOGETHER WITH ANY AUXILIARY ITEMS TO ALLOW NEW CONSTRUCTION AND FINISH TO OCCUR AS COMPLIMENTED BY THECONTRACT DOCUMENTS. HEAVY, DASHED LINES INDICATE EXISTING DEVICES AND EQUIPMENT TO BE REMOVED.3.E.C. TO REMOVE ELECTRICAL CONNECTIONS TO ALL MECHANICAL EQUIPMENT TO BE DEMOLISHED. E.C. SHALL CHECK ALLDEMOLITION PLANS AND ACTUAL FIELD CONDITIONS FOR UNIT LOCATIONS. ALL ACCESSIBLE CONDUITS PENETRATINGTHROUGH THE ROOF SHALL BE REMOVED.4.THE DEMOLITION PLANS HAVE NO INTENT TO SHOW ALL ELECTRICAL DEVICES TO BE REMOVED. ELECTRICAL CONTRACTORSHALL VERIFY DEMOLITION WORK INVOLVED PRIOR TO BID.5.REMOVE ALL ELECTRICAL AND SIGNALING DEVICES AS INDICATED (INCLUDING, BUT NOT LIMITED TO, REMOVAL OF ALLELECTRICAL PANELS, LIGHTING FIXTURES, RECEPTACLES, MOTOR DISCONNECTS, FIRE ALARM AND OTHER LOW VOLTAGEDEVICES), UNLESS NOTED OTHERWISE.6.REMOVE ALL WIRES, CABLES AND SURFACE MOUNT RACEWAYS AND APPURTENANCES WHICH SERVE DEVICES BEINGREMOVED, CUT CONDUIT FLUSH TO CEILING OR WALL WHEN CONCEALED, AND SEAL OFF WITH SPRAY FOAM. ABANDON FLUSHBOXES AND NON-ACCESSIBLE CONDUIT. PROVIDE COVER PLATES FOR ALL BOXES TO REMAIN.7.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR FOR ALL CUTTING, PATCHING AND FINISHWORK.8.FIELD VERIFY EXISTING CONDITIONS AND RACEWAYS CAST IN CONCRETE.9.MAINTAIN CONTINUITY AND OPERATION OF ALL EXISTING BUILDING TENANT POWER, LIGHTING, AND LOW VOLTAGE SYSTEMSDURING DEMOLITION AND CONSTRUCTION. PROVIDE JUNCTION BOXES, CONDUIT AND WIRE TO EXTEND EXISTING CIRCUITS ASREQUIRED.GENERAL DEMOLITION NOTES (APPLY TO ALL SHEET)MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHELECTRICALGENERALNOTESE0.0312/2/202212/13 /2022 1A234567BCD89CONSTRUCTION NOTESDEMOLISH ALL LIGHTING FIXTURES AND CONTROLS WITHIN THE APPLICABLE PROJECTAREA OF WORK. RETAIN EXISTING CONDUIT, WIRING, CIRCUITING, AND APPURTENANCES, AS REQUIRED, TO FACILITATE NEW SCOPE OF WORK.BASE BID: DEMOLITION SCOPE LIMITED TO LIGHTING FIXTURES AND CONTROLS ASSOCIATED WITH NEW RECEPTION 733, SECURE FILES 738, AND BREAK ROOM 739 ONLY. SEE E2.10 AND E6.21 FOR ADDITIONAL INFORMATION. REVISE EXISTING WIRINGAND CONNECTIONS TO MAINTAIN CIRCUIT CONTINUITY TO EXISTING DEVICES TO REMAIN.ALTERNATE BID NO. 2: UNDER ADDITIVE ALTERNATE, ALL LIGHTING FIXTURES AND CONTROLS ARE REPLACED, AS DETAILED IN THE ELECTRICAL DRAWINGS AND SPECIFICATIONS.BASE BIDALTERNATE BID NO. 211GENERAL NOTES1.ALL DEVICES SHOWN ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TOSTARTING WORK.1MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateNHBHSEVENTHFLOORLIGHTINGDEMO PLANED2.10SCALE:1SEVENTH FLOOR LIGHTING DEMO PLAN1/8"=1'-0"12/2/202212/13 /2022 UP1A234567BCD89JF96"JF48"JF72"60"JFJFSCALE:2ENLARGED ELECTRICAL ROOM1/4" = 1'-0"2ED3.10GENERAL NOTES1.ALL DEVICE LOCATIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELDVERIFIED PRIOR TO STARTING WORK.H7P7-2P7-1P7P7-37T2L77T1(E) RELAYS(E) 225A ENCLOSEDCIRCUIT BREAKER (E) ACCESSCONTROL PANELS(E) FIRE ALARMCONTROL PANELVAV724VAV722VAV716VAV720VAV718VAV719VAV721VAV723VAV717VAV7151222222222DEMOLITION NOTESEXISTING MECHANICAL UNIT TO REMAIN.UNDER ALTERNATE BID NO. 1 EXISTING MECHANICAL UNIT TO BE DEMOLISHED ANDREPLACED BY OTHERS. COORDINATE ELECTRICAL REQUIREMENTS WITH THEMECHANICAL CONTRACTOR. SEE CONNECTION SCHEDULE ON E6.01 FORADDITIONAL INFORMATION.EXISTING DUPLEX RECEPTACLE TO BE REPLACED WITH FOURPLEX RECEPTACLE.SEE SHEET E3.10 FOR ADDITIONAL INFORMATION.1233333MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateNHBHSEVENTHFLOORPOWERDEMO PLANED3.10SCALE:1SEVENTH FLOOR POWER DEMO PLAN1/8"=1'-0"12/2/202212/13 /2022 UP1A234567BCD89CRCRTV REXREXESSTVT VSJJJJ JJJJJJHDMI 7-4-21-247-4-25-287-4-33-367-4-37-407-5-1-47-5-9-127-4-13-167-5-17-207-5-21-247-5-25-287-5-37-407-8-21-247-8-25-287-8-17-207-5-29-327-5-33-36J20DEMOLITION NOTESDEMOLISH CABLE AND RE-USE JUNCTION BOXES AND CONDUIT FOR NEW DATACABLING PATHWAY INTO FURNITURE.RELOCATE FIRE ALARM HORN STROBE TO NEW LOCATION SHOWN ON SHEET E4.10.EXISTING LENEL ACCESS CONTROL SYSTEM AND EDWARDS SIGNALING NACPOWER SUPPLIES LOCATED IN ELECTRICAL ROOM.111SRACK 2RACK 1STSTSTSTST23ACP3FAPSDD3LVLVLVLVLVLVLVLVLVLVLVMACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHSEVENTHFLOORSYSTEMSDEMO PLANED4.10SCALE:1SEVENTH FLOOR SYSTEMS DEMO PLAN1/8"=1'-0"12/2/202212/13 /2022 1A234567BCD8900-02RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1PL2,cPL2,cPL2,cRL2,cRL2,cRL2,bRL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1PL1,aLVLVLVLVLVOSLVPCPCPCPCPCPCPCPCOSOSOSOSOSOSOSOSOSOSOSVSVSVSVSEX1EX1EX1LV,a,bRL2,bRL2,bRL2,bLV,a,bLVLVCONSTRUCTION NOTESBASE BID: PROVIDE ALL LIGHTING, CONTROLS, AND ASSOCIATED APPURENTANCESDETAILED IN THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR RECEPTION733, SECURE FILES 738, AND BREAK ROOM 739 ONLY.ALTERNATE BID NO. 2: UNDER ADDITIVE ALTERNATE, PROVIDE ALL LIGHTING,CONTROLS, AND ASSOCIATED APPURENTANCES FOR ALL SPACES IN PROJECTSCOPE, AS DETAILED IN THE ELECTRICAL DRAWINGS.INSTALL LIGHT FIXTURE CENTERED OVER TABLE - COORDINATE FINAL LOCATIONWITH ARCHITECT AND FURNITURE PLAN PRIOR TO INSTALLATION.1GENERAL NOTES1.PROVIDE POWER TO NEW LED LIGHTING FIXTURES FROM NEARESTUNSWITCHED LIGHTING CIRCUIT. RECONFIGURE WIRING, AS NECESSARY, TOACCOMMODATE NEW LIGHTING CONTROL SCHEME DETAILED ON DRAWINGS.11LV,cRL1RL1RL1RL1RL1CONFERENCE737BREAKROOM739SECUREFILES738RECEPTION733OPEN OFFICE734OFFICE736OFFICE735OFFICE734BOFFICE734ARL1RL2,bRL2,bBASE BIDALTERNATE BID NO. 211LV22MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateNHBHSEVENTHFLOORLIGHTINGPLANE2.10SCALE:1SEVENTH FLOOR LIGHTING PLAN1/8"=1'-0"1112/2/202212/13 /2022 UPDN1A234567BCD89P7P7-37T2L77T1CONSTRUCTION NOTESPROVIDE CONNECTION(S) FOR POWERED FURNITURE. CIRCUITS NOTED WITH AN"(S)" REPRESENT CIRCUITS FOR CONTROLLED RECEPTACLES. PROVIDE POWERPACKS AS REQUIRED, TO INTEGRATE CONTROLLED RECEPTACLES WITH THELIGHTING CONTROL SYSTEM. CIRCUITING IS BASED ON A 2+2 WIRING HARNESSCONFIGURATION. IF A DIFFERENT WIRING HARNESS IS PROVIDED BY THEMANUFACTURER, MODIFICATIONS TO THE CIRCUITING SHOWN MAY NEED TO BEMADE IN THE FIELD. COORDINATE EXACT LOCATION AND REQUIREMENTS WITHFURNITURE INSTALLER PRIOR TO ROUGH-IN.PROVIDE WITH GFCI BREAKER.PROVIDE 120V POWER FOR PINCH BOXES. CONTROLS CONTRACTOR TO PROVIDEAND INSTALL CONDUIT AND WIRE FROM THIS LOCATION TO UNIT LOCATIONS ASNOTED ON MECHANICAL SHEETS.EXISTING VAV TO REMAIN.EXTEND EXISTING FURNITURE CONNECTION TO NEW LOCATION, AS NECESSARY,TO COORDINATE WITH NEW FURNITURE LAYOUT. PROVIDE NEW CIRCUITING ASINDICATED.REPLACE EXISTING DUPLEX RECEPTACLE WITH NEW DEVICE AS NOTED.1JF48"JF72"60"JF2E3.10TVJJ11CC111BREAKROOM739RECEPTION733OFFICE736OFFICE735OFFICE734ACONFERENCE737OFFICE734BSECUREFILES738OPEN OFFICE734STORAGE737BDGENERAL NOTES1.BASE BID: UNDER BASE BID, THE HVAC SYSTEM AND ASSOCIATED CONTROLSARE EXISTING TO REMAIN.ALTERNATE BID NO. 1: UNDER ADDITIVE ALTERNATE, PROVIDE ALL MECHANICALCONNECTIONS, EQUIPMENT, AND ASSOCIATED APPURTENANCES DETAILED IN THEELECTRICAL PLANS AND SPECIFICATIONS. COORDINATE WITH THE MECHANICALCONTRACTOR PRIOR TO STARTING WORK.2.PER WASHINGTON STATE ENERGY CODE SECTION C503.6.6, EXCEPTION #1, CONTROLLED RECEPTACLES ARE NOT REQUIRED ON THIS PROJECT.3.REPLACE ALL RECEPTACLES AND COVER PLATES WITHIN AREA OF SCOPE INLOCATIONS SHOWN AS EXISTING TO REMAIN.4.THIS BUILDING UTILIZES POST-TENSION SLABS BETWEEN FLOORS. GC TO X-RAYFLOOR PRIOR TO ANY PENETRATIONS. 2P7-1 - 20P7-1 - 20(S)P7-1 - 20P7-1 - 20(S)P7-2 - 36P7-2 - 36(S)P7-1 - 24P7-1 - 24P7-1 - 22P7-3 - 22P7-3 - 22(S)P7-3 - 22P7-3 - 22(S)P7-2 - 42P7-3 - 16P7-1 - 39P7-1 - 39P7-1 - 39P7-1 - 39P7-3 - 20P7-3 - 20P7-3 - 20P7-3 - 20P7-2 - 36P7-3 - 28P7-3 - 28P7-3 - 28P7-3 - 28P7-3 - 30P7-3 - 32P7-3 - 32P7-3 - 32P7-3 - 32CBREAKROOM739CREFRIGERATOR2CSECUREFILES7383E3.10P7-3 - 34P7-3 - 36P7-3 - 38P7-3 - 38P7-3 - 38P7-3 - 38P7-3 - 40P7-1 - 39VAV724VAV722VAV716VAV720VAV718VAV719VAV721VAV723VAV717VAV715H7P7-2P7-1(E) RELAYS(E) 225A ENCLOSEDCIRCUIT BREAKER(E) ACCESSCONTROL PANELS(E) FIRE ALARMCONTROL PANELDISHWASHER2MICROWAVE23JP7-3 - 42344551J1P7-3 - 22P7-3 - 22(S)6JFP7-2 - 36P7-2 - 36(S)JP7-2 - 36P7-2 - 36(S)6P7-1 - 24P7-1 - 226P7-1 - 226CCCC62P7-3 - 20MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateNHBHSEVENTHFLOORPOWERPLANE3.10SCALE:1SEVENTH FLOOR POWER PLAN1/8"=1'-0"SCALE:2ENLARGED ELECTRICAL ROOM PLAN1/4"=1'-0"SSCALE:3ENLARGED BREAK ROOM PLAN1/4"=1'-0"12/2/202212/13 /2022 UPDN1A234567BCD8944,F4,F4,F4,FJ4,F4,F4JJ(1) 2" C.CONSTRUCTION NOTESUTILIZE EXISTING BACKBOX FOR NEW DATA CABLING PATHWAY INTO FURNITURE.ROUTE CONDUIT TO THE NEAREST ACCESSIBLE CEILING FOR FURNITURE DATACABLING. COORDINATE CABLE PULL, TERMINATIONS AND FACEPLATEREQUIREMENTS WITH THE INSTALLING FURNITURE CONTRACTOR PRIOR TO ROUGHIN.RELOCATED FIRE ALARM STROBE. RECONNECT AS REQUIRED.COORDINATE WITH THE CITY FOR ALL SCHEDULING AND ACCESS REQUIREMENTSFOR THIS TELECOM ROOM. SEE SHEET E7.11 FOR ADDITIONAL CABLINGINFORMATION.PROVIDE NEW CARD READER AT THIS DOOR.PROVIDE CONNECTION TO MODULAR FURNITURE. COORDINATE EXACT MODULARSYSTEM REQUIREMENTS PRIOR TO ROUGH-IN.14,F4,FJ1RACK 2RACK 1J(1) 2" C.222(1) 2" C.2T V34CR 55CRREXESSSJ14,F4,F1SREX4,F4,F4,F4,FD44BREAKROOM739RECEPTION733OFFICE736OFFICE735OFFICE734ACONFERENCE737OFFICE734BSMALLCONFERENCE733ASECUREFILES738OPEN OFFICE734STORAGE737B6666666666666664LVLVLVLVLVLVSSSGENERAL NOTES1.THIS BUILDING UTILIZES POST-TENSION SLABS BETWEEN FLOORS. GC TOX-RAY FLOOR PRIOR TO ANY PENETRATIONS.CRTV REXHDMI SD4,F4,F6644MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHSEVENTHFLOORSYSTEMSPLANE4.10SCALE:1SEVENTH FLOOR SYSTEMS PLAN1/8"=1'-0"12/2/202212/13 /2022 MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHONE-LINEDIAGRAME6.01PANEL 'H7'480Y/277V200A 3Ø, 4W3P-100AXFMR '7T2'75KVA225A PANEL 'P7-3'208Y/120V225A 3Ø, 4W3P-150APANEL 'P7'208Y/120V150A 3Ø, 4W1/04/04/04/0PANEL 'L7'480Y/277V225A 3Ø, 4W3P-70ATRANSFORMER7T145KVAPANEL 'P7-1'208Y/120V150A 3Ø, 4W3/0PANEL 'P7-2'208Y/120V150A 3Ø, 4W3P-150A 3P-150AFROM FLOOR 6SCALE:1SEVENTH FLOOR EXISTING ONE-LINE DIAGRAMDIAGRAMMATICFROM FLOOR 6GENERAL MECHANICAL CONNECTION SCHEDULE NOTES1.BASE BID: UNDER BASE BID, THE HVAC SYSTEM AND ASSOCIATED CONTROLS AREEXISTING TO REMAIN.2.ALTERNATE BID NO. 1: UNDER ADDITIVE ALTERNATE, PROVIDE ALL MECHANICAL CONNECTIONS, EQUIPMENT, AND ASSOCIATED APPURTENANCES DETAILED IN THE ELECTRICAL PLANS AND SPECIFICATIONS. COORDINATE WITH THE MECHANICALCONTRACTOR PRIOR TO STARTING WORK.PROVIDE CONNECTION AND SPECIFIED ELECTRICAL EQUIPMENT IN BOTH BASE AND ALTERNATE BID SCOPES.12/2/202212/13 /2022 MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateMMBHPANELSCHEDULES IE6.1112/2/202212/13 /2022 111111111111111233332211111MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateMMBHPANELSCHEDULES IIE6.1212/2/202212/13 /2022 GENERAL NOTES1.FIXTURE TYPES LISTED ARE TO INDICATE THE TYPE, STYLE, LAMPING CHARACTERISTICS, AND MOUNTING REQUIRED TO FACILITATE THIS DESIGN.OTHER FIXTURE MANUFACTURERS MEETING THE LIGHTING FIXTURE CRITERIA ARE ACCEPTABLE UPON APPROVAL BY THE ARCHITECT AND ENGINEER.2.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL LIGHT FIXTURE FINISH COLORS WITH THE ARCHITECT AND OWNER.3.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND MOUNTING HARDWARE FOR A COMPLETE SYSTEM. COORDINATELOCATION OF ALL REMOTE LED DRIVES - LOCATION SHALL BE CONCEALED AND READILY ACCESSIBLE.4.PER WASHINGTON STATE ENERGY CODE SECTION C503.6.6, EXCEPTION #1, CONTROLLED RECEPTACLES ARE NOT REQUIRED ON THIS PROJECT.COMMISSIONING REQUIREMENTS FOR THE LIGHTING CONTROL SYSTEMTESTING SHALL ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED, AND IN THE PROPER WORKING CONDITIONIN MANUFACTURER'S INSTALLATION INSTRUCTIONS. WRITTEN PROCEDURES WHICH CLEARLY DESCRIBE THE INDIVIDUAL SYSTEMATIC TEST PROCEDURES, THEEXPECTED SYSTEMS' RESPONSE OR ACCEPTANCE CRITERIA FOR EACH PROCEDURE, THE ACTUAL RESPONSE OR FINDINGS, AND ANY PERTINENT DISCUSSIONSHALL BE FOLLOWED. AT A MINIMUM, TESTING SHALL AFFIRM OPERATION DURING NORMALLY OCCUPIED DAYLIGHT CONDITIONS. THE CONSTRUCTIONDOCUMENTS SHALL STATE THE PARTY WHO WILL CONDUCT THE REQUIRED FUNCTIONAL TESTING. ALL TESTING AND DOCUMENTATION SHALL COMPLY WITHC408.3 OF THE WASHINGTON STATE ENERGY CODE. FOR OCCUPANT SENSORS, TIME SWITCHES, PROGRAMMABLE SCHEDULE CONTROLS, PHOTO-SENSORS ORDAYLIGHT CONTROLS, THE FOLLOWING PROCEDURES SHALL BE PERFORMED:1.CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIMEOUT ADJUSTMENTS FOR OCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE.2.CONFIRM THAT THE TIME SWITCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TO TURN THE LIGHTS OFF.3.CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTO-SENSOR CONTROLS REDUCE ELECTRIC LIGHT BASED ON THE AMOUNT OFUSABLE DAYLIGHT IN THE SPACE AS SPECIFIED.LIGHTING / RECEPTACLE CONTROL SEQUENCE FOR COMMISSIONINGGENERAL REQUIREMENTS1.THE LIGHTING CONTROLS SYSTEM SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS IN WSEC C405.2.VACANCY/OCCUPANCY SENSORS SHALL BE CONNECTED TOGETHER FOR CONTROL OF ALL LIGHTS IN THE ROOM. SET UP SENSORS AS INDICATED INOCCUPANCY OR VACANCY MODE.3.VACANCY MODE – MANUAL ON, AUTO OFF VIA SENSOR, SET AT 20 MIN.4.OCCUPANCY MODE – AUTOMATIC ON TO 50%, AUTO OFF VIA SENSOR, SET AT 20 MIN.5.ALL OCCUPANCY/VACANCY SENSORS SHALL BE DUAL TECHNOLOGY (I.E. INFRARED AND ULTRASONIC).6.PHOTOCELLS TO BE INSTALLED AS RECOMMENDED BY THE MANUFACTURER.a. TRIGGER 1 OF PHOTOCELL TO CONTROL LIGHTS IN PRIMARY DAYLIGHT ZONES (PDZ)b. TRIGGER 2 OF PHOTOCELL TO CONTROL LIGHTS IN SECONDARY DAYLIGHT ZONES (SDZ)c. PHOTOCELLS SHALL BE CONFIGURED AND ADJUSTABLE FROM THE FLOOR.7.ALL PHOTOCELLS SHALL HAVE THE CAPABILITY TO COMPLETELY SHUT OFF LIGHTS WITH SUFFICIENT NATURAL LIGHT.8.PROGRAMMING SHALL BE PROVIDED FOR ADJUSTMENT OF LIGHTS.9.ALL LIGHTS SHALL BE PROVIDED WITH PROVISIONS FOR CONTROL VIA 0-10V DIMMING.10.EMERGENCY LIGHTING RELAY REQUIRED FOR CONNECTION TO ANY DESIGNATED EMERGENCY LIGHT FIXTURES WITHIN EACH SPACE FOR AUTOMATICOVERRIDE UPON A POWER FAILURE.INDIVIDUAL ROOM / PRIVATE OFFICE LIGHTING CONTROLS1.OFFICES AND SMALL ROOMS WITH A WINDOW SHALL HAVE A PHOTOCELL (CEILING-MOUNTED OR INTEGRAL)2.ALL OFFICES AND SMALL ROOMS SHALL HAVE VACANCY SENSORS (CEILING-MOUNTED OR INTEGRAL).3.SENSORS SHALL BE SET TO VACANCY MODE SO THAT THE USER IS REQUIRED TO PRESS A BUTTON ON THE WALL STATION TO TURN ON THE LIGHTS.4.A DIMMER SHALL BE PROVIDED ON THE WALL TO ALLOW MANUAL ADJUSTMENT OF THE LIGHTING LEVEL.OPEN OFFICE / CONFERENCE / MULTI-ZONE ROOMS1.AUTOMATIC DAYLIGHT HARVESTING CONTROLa. LIGHTS IN PDZ a(p) or b(p)– AUTO DIM CONTROLLED WITH PHOTOCELL – TRIGGER LEVEL 1.b. LIGHTS IN SDZ a(s) or b(s) – AUTO DIM CONTROLLED WITH PHOTOCELL – TRIGGER LEVEL 2.2.MANUAL SWITCHING AND DIMMING CONTROLa. CONTROL ZONE a(p) or a(s)b. ADDITIONAL ZONES AS INDICATED / REQUIRED ( b(p) or b(s), c(p) or c(s), etc.)3.OCCUPANCY/VACANCY SENSORS SET TO VACANCY MODE – MANUAL ON ALL, PHOTOCELL ENABLED.a. LIGHTS IN ALL CONTROL ZONES AUTO OFF 20 MINUTES AFTER ALL OCCUPANTS HAVE LEFT THE OPEN OFFICE (ALL CONTROL ZONES).5.DESIGNATED RECEPTACLES SHALL BE AUTOMATICALLY SWITCHED ON/OFF VIA LOCAL OCCUPANCY/VACANCY SENSOR.6.DIMMER SWITCH WALL CONTROL STATION:a. BUTTON 1 -i. LABEL: ALL ON/OFFii. FUNCTION: ALL ON/OFF - ALL LIGHTS ON 100%, PHOTOCELL ENABLEDb. BUTTON 2 -i. LABEL: UP/DOWNii. FUNCTION: MANUAL DIM OR RAISE ALL LIGHTS TOGETHER c. PROVIDE ADDITIONAL BUTTONS FOR EACH SUBSEQUENT CONTROL ZONE -i. EACH CONTROL ZONE SHALL HAVE ITS OWN ON/OFF/DIM/RAISE FUNCTIONALITYELECTRICAL / MECHANICAL / DATA1.ROOM SHALL BE STAND-ALONE AND NOT TIED TO THE BUILDING LIGHTING CONTROL SYSTEM.2.LIGHTS CONTROLLED BY ON/OFF SWITCH. CORRIDORS / MULTI-STALL RESTROOMS / STAIRS1.ALL LIGHTS CONTROLLED BY OCCUPANCY SENSORa.OCCUPANCY/VACANCY SENSORS SET TO OCCUPANCY MODE - AUTOMATICALLY TURN LIGHTS ON TO 100%.MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateMMBHLIGHTINGFIXTURESCHEDULEANDCONTROLSE6.2112/2/202212/13 /2022 FIBER LIUBLANKCABLE MANAGERFIBER LIUSWITCHCABLE MANAGERSWITCHCABLE MANAGERSWITCHCABLE MANAGERSWITCHCABLE MANAGERSHELFSWITCHCABLE MANAGERSHELFPSUPSUUPSUPSCABLE MANAGERPP 1 (48-PORT)CABLE MANAGERPP 2 (48-PORT)CABLE MANAGERPP 3 (48-PORT)CABLE MANAGERPP 4 (48-PORT)CABLE MANAGERPP 5 (48-PORT)CABLE MANAGERPP 6 (48-PORT)CABLE MANAGERPP 7 (48-PORT)CABLE MANAGERPP 8 (48-PORT)PP (25-PAIR)PP (24-PORT)PDUSCALE:1EXISTING RACKSNTSRACK 1RACK 2IDF-1-1-01,02 PORT NUMBER(S) OF TELECOM OUTLETIDF OR MDF NUMBERDESIGNATIONLABELDATADATADATA26221DATAPATCH PANEL NUMBER21234567TELECOM OUTLET CONSTRUCTION NOTES41" EMT OUT TO ACCESSIBLE CEILINGPROVIDE COMPRESSION TYPE STEELCONNECTORPROVIDE 4" SQUARE 2-1/8" DEEP OUTLET BOX(RACO #233 OR SIMILAR)PROVIDE PULL STRINGPROVIDE MUD RING, 1 OR 2 GANG OPENINGAS REQUIRED. PROVIDE APPROPRIATELENGTH COLLAR FOR FLUSH INSTALLATIONWITH FINISHED WALL SURFACE. (RACO #7XXSERIES OR SIMILAR)HORIZONTAL CABLING (PERMANENTLINK) PROVIDE QUANTITIES ANDTYPE AS REQUIREDSINGLE/DOUBLE GANGFACEPLATE AS REQUIREDPROVIDE QUANTITIES ANDTYPES OF JACKS ASREQUIREDIDF-2-5-01,02SCALE:1TELECOMMUNICATIONS OUTLETLABEL IDENTIFICATION FORMATDIAGRAMMATICSCALE:2TYPICAL CAT6 HORIZONTAL CABLE LABELINGDIAGRAMMATICSCALE:5TYP. TELECOMMUNICATIONSOUTLET LABELINGDIAGRAMMATICSCALE:3TELECOMMUNICATIONS OUTLETINSTALLATION DETAIL - NEW LOCATION ON NEW WALLSDIAGRAMMATICSCALE:4TYPICAL TELECOMMUNICATIONSFOUR-PORT DATA OUTLETDIAGRAMMATICPLEASE NOTE: ONLY INSTALL THIS OUTLET TYPE IN THE FOLLOWINGLOCATIONS: 1. IN AN ACCESSIBLE CEILING SPACE. 2. IN A JUNCTION BOX. 3. IN THE MDF ROOM OR DESIGNATED IDF LOCATION.452SCALE:6TYPICAL TELECOMMUNICATIONS OUTLET(ACCESSIBLE CEILING SPACE & J-BOX)DIAGRAMMATICTELECOMMUNICATIONS OUTLET GENERAL NOTES1.PROVIDE CUT-IN PLATES ON EXISTING WALLS FOR NEWTELECOMMUNICATIONS OUTLETS.2.PROVIDE CONDUIT AND BACKBOXES AS SHOWN ON DETAIL NUMBER 4 OFTHIS SHEET FOR NEW TELECOMMUNICATIONS OUTLETS IN NEW WALLS.3.PROVIDE BLANK COVER PLATES FOR ANY UNUSED EXISTING OUTLETSLOCATIONS THAT HAVE BEEN DEMOLISHED AND WILL NOT BE USEDDURING THE NEW TELECOMMUNICATIONS WIRING. PAINTED TO MATCHADJACENT SURFACE.RACK NUMBERIDF OR MDF - RACK - PANEL - PORTIDF-2-5-03,04SEE SECTION 27 20 00 FOR TELECOMMUNICATIONS OUTLET TYPE, STYLE.PROVIDE WHITE FACEPLATES. PROVIDE WHITE TELECOMMUNICATIONSWALL OUTLET WITH WHITE FACEPLATES AND LABEL.PROVIDE MODULAR BLANK INSERT. THE COLOR SHALL MATCH THEADJACENT PORT COLOR.PROVIDE (1) CAT6A CABLE FOR WIRELESS ACCESS POINT LOCATIONS.PROVIDE THE CABLE COLORS AS SPECIFIED IN SECTION 27 20 00.PROVIDE A 25 FOOT SERVICE LOOP IN THE ACCESSIBLE CEILING SPACE,UNLESS OTHERWISE NOTED.PROVIDE (4) CAT6 CABLES FROM THE TELECOMMUNICATION OUTLET TOTHE NEAREST TELECOMMUNICATIONS ROOM. PROVIDE THE CAT6 CABLECOLOR AS SPECIFIED IN SECTION 27 20 00.RACK ELEVATIONS ARE DIAGRAMMATIC. PROVIDE NEW PATCH PANELS ASREQUIRED PER SPECIFICATIONS. EXISTING PATCH PANELS ARECOMMSCOPE NETCONNECT MODULAR PATCH PANELS.77MACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHSYSTEMSDETAILSE7.1112/2/202212/13 /2022 WALLARLINGTONCONDUIT BUSHING1" EMTBACKBOX(S)HORIZONTAL NETWORK CABLE(CAT6/FIBER/ETC)EMT THRU WALLSLEEVE WITHARLINGTON CONDUITBUSHING -OR-MECHANICALPATHWAY ASSEMBLY(SEE FLOOR PLANS)HALLWAYACCESSIBLE CEILINGSWALL MOUNTEDJ-HOOKS (TYP)WALLWALLFLOOR6" MIN48" ON CENTERHORIZONTAL SIGNAL/COAX CABLEARLINGTONCONDUIT BUSHINGSCALE:1J-HOOK AND CABLE TRAY SECTION DETAILDIAGRAMMATICTELECOM ROOMMACKENZIEALL RIGHTS RESERVEDTHESE DRAWINGS ARE THE PROPERTY OFMACKENZIE AND ARE NOT TO BE USEDOR REPRODUCED IN ANY MANNER,WITHOUT PRIOR WRITTEN PERMISSIONSHEETJOB NO.SHEET TITLE:CHECKED BY:DRAWN BY:Project©Client3/22/2022 12:36:20 PMRenton 7th Floor HR-B_detached.rvt 1/8" = 1'-0"Human Resources 7thFloor TenantImprovement1055 S Grady Way,Floor 4, Renton, WA98057City of Renton2210142.0001/03/2023PERMIT | BID DOCUMENTS2019Revision ScheduleRevision DeltaIssue DateBCBHSYSTEMSDETAILSE7.1212/2/202212/13 /2022