Loading...
HomeMy WebLinkAboutCA_2166 Vay Vong_full engineering packet_20221017_V1PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 PROJECT INFO PV-1SCALE: 2 PV-1 LOCALE NTS SCALE: 1 PV-1 PLOT NTS NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS SCOPE OF WORK DESCRIPTION THE PROPOSED SYSTEM IS A ROOF MOUNTED PHOTOVOLTAIC ARRAY UTILIZING MICROINVERTERS. THE PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED ON THE RESIDENTIAL ZONED PROPERTY IN THE CITY OF RENTON, WASHINGTON. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA A LINE SIDE CONNECTION. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. CONSTRUCTION NOTES 1 CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 2 CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 3 ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 5 ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 6 ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. 7 ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 VOLTS AND 90°C WET ENVIRONMENT, UNLESS OTHERWISE NOTED. 8 WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 9 PV MODULES FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 10 PV MODULES RACKING RAIL SHALL BE BONDED TO BARE COPPER G.E.C VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 11 GROUNDING ELECTRODE CONDUCTOR (G.E.C) SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED 12 ALL JUNCTION BOXES, COMBINER BOXES, AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 13 WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC SECTION 110.26. DIRECTORY OF PLAN PAGES PV1 PROJECT INFORMATION PV2 SITE PLAN PV3 SINGLE-LINE DIAGRAM PV4 PLACARDS PV5 ATTACHMENT PLAN PV-6A PV-6B IRON RIDGE FLASHFOOT2 MOUNTING DETAILS PV-6C IRON RIDGE FLASHFOOT2 INSTALLATION PV7 RACKING DATASHEET PV8 PV MODULE DATASHEET PV9 MICROINVERTER DATASHEET PV10 CLASS A FIRE RATING DATASHEET PV11 STATE OF WASHINGTON ENGINEERING LETTER (IRONRIDGE RACKING) PV12 GROUNDING DETAILS (IRON RIDGE RACKING) PV13 RAPID SHUTDOWN DATASHEET PV14 ENPHASE IQ COMBINER 4 DATASHEET PROJECT DETAILS PROPERTY OWNER VAY VONG PROPERTY ADDRESS 5117 NE 7TH PL RENTON, WA 98059 TAX PARCEL NO.9211010210 AHJ CITY OF RENTON ZONING RESIDENTIAL CONST. TYPE FLUSH ROOF-MOUNTED PHOTOVOLTAIC ARRAY OBSERVED CODES 2020 NATIONAL ELECTRICAL CODE (NEC) 2018 WASHINGTON ADMINISTRATIVE CODE (WAC) 2018 WASHINGTON STATE ENERGY CODE - RESIDENTIAL 2018 INTERNATIONAL CODES REVISED CODE OF WASHINGTON (RCW) WASHINGTON BUILDING CODE & STATE AMENDMENTS APPLICABLE CITY CODE WHEN PRESENT OSHA 29 CFR 1910.269 UNDERWRITERS LABORATORIES (UL) STANDARDS STRUCT. METHOD ASCE7-16 SYSTEM DETAILS DC RATING OF SYSTEM 15,390W AC OUTPUT CURRENT 55.1A MICROINVERTER (38) ENPHASE IQ8A-72-2-US MODULE (38) REC SOLAR REC405AA PURE BRANCH CONFIGURATION 1 BRANCH OF 5 MICROINVERTERS 3 BRANCHES OF 11 MICROINVERTERS INTERCONNECTION LINE-SIDE CONTRACTOR INFORMATION CONTRACTOR SOLTERRA GLOBAL, LLC. LICENSE NO.SOLTEGL838BS ADDRESS 2909 1ST AVENUE S SEATTLE, WA 98134 PHONE (425) 921-0457 CONTRACTOR SIGNATURE SITE SPECIFICATIONS UTILITY SERVICE 120 / 240VAC, 1-Ø, 3W MAIN SERVICE PANEL 200A RATED BUSBAR 200A / 2P MAIN BREAKER ASHRAE EXTREME ANNUAL MEAN MINIMUM DENSITY DRY BULB TEMP. -6°C ASHRAE 2% ANNUAL DRY DENSITY BULB TEMP. 29°C DESIGN WIND SPEED 110 MPH DESIGN SNOW LOAD 15 PSF WIND EXPOSURE CATEGORY B RISK CATEGORY II PLAN DESIGNER INFORMATION COMPANY GEMINI SOLAR DESIGN, LLC. NAME SANJAY CHRISTOPHER MALLIPUDI ADDRESS 2575 OLD ARCATA ROAD BAYSIDE, CA 95524 PHONE (609) 802-5743 PLAN DESIGNER SIGNATURE RECEIVED 10/17/2022 striplett BUILDING DIVISION B22005501REVIEWED Paul Wong 10/25/2022 BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTON BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUCTED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS Note: This approval is for the non structural review only. NOTICE: SCHEDULE A ROUGH INSPECTION TO VERIFY PROPER GROUNDING BEFORE ARRAYS ARE INSTALLEDAPPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 10/26/2022 M MM AC IQ J 90' 50' 105' 30' 24' 18" 24'-3" 6'-3"6'-3" 45'-6" (N) ENPHASE IQ COMBINER 4, (1) X 15A / 2P, BRANCH BREAKER (3) X 20A / 2P, BRANCH BREAKER (LOC. ON EXTERIOR) (E) 200A MAIN SERVICE PANEL (E) 200A / 2P MAIN BREAKER 120 / 240VAC - 1ɸ - 3W - NEMA 3R (N) LINE-SIDE TAP POINT OF INTERCONNECTION AS PER NEC 240.21(B)(1) & NEC 705.12(A) (LOC. ON INTERIOR) (E) SINGLE FAMILY DWELLING (E) PROPERTY LINE (E) DRIVEWAY NE 7T H P L (N) NEMA 3R J-BOX (LOC. UNDER MODULE) (N) PV ARRAY 180° AZIMUTH, 5:12 PITCH (38) REC SOLAR REC405AA PURE (38) ENPHASE IQ8A-72-2-US (N) UTILITY AC DISCONNECT (DS1), EQUIP WITH (2) X 70A FUSES, 240VAC 1-ɸ, 3-WIRE, 2-POLE, 100A BUS RATING, MEANS OF DISCONNECTION FOR THE LINE-SIDE TAP POINT OF CONNECTION (LOC. ON EXTERIOR) (E) UTILITY METER (LOC. ON EXTERIOR) PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 SITE PLAN PV-2NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS SCALE: A PV-2 SITE PLAN 1" = 12' SITE PLAN NOTES 1 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 319.0(D). 2 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C). 3 ARRAYS SHALL BE INSTALLED IN A WAY THAT ENSURES THAT PV SOURCE CONDUCTORS SHALL NOT BE READILY ACCESSIBLE. 1 BRANCH OF 11 MICROINVERTERS (ENPHASE IQ8A-72-2-US) 1 BRANCH OF 11 MICROINVERTERS (ENPHASE IQ8A-72-2-US) 1 BRANCH OF 11 MICROINVERTERS (ENPHASE IQ8A-72-2-US) 1 BRANCH OF 5 MICROINVERTERS (ENPHASE IQ8A-72-2-US)B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION KWHR TO UTILITY @ 120 / 240VAC, 1-Ø, 3W MAIN SERVICE PANEL 120 / 240VAC, 1-ɸ, 3-WIRE 200A RATED BUSBAR 200A / 2P MAIN BREAKER (LOC. ON INTERIOR) (E) GEC (E) 200A / 2P MAIN BREAKER (E) UTILITY METER OTHER LOADS... LINE-SIDE TAP POINT OF INTERCONNECTION AS PER NEC 240.21(B)(1) & NEC 705.12(A) 3 PE OTHER LOADS... 3 CB1 15A ENPHASE IQ 8A MICROINVERTER, LOCATED UNDER PV MODULE PM1-38 405W 5 IN BRANCH 11 IN BRANCH 1 11 IN BRANCH 1 (N) UTILITY AC DISCONNECT (DS1), EQUIP WITH (2) X 70A FUSES, 240VAC 1-ɸ, 3-WIRE, 2-POLE, 100A BUS RATING, MEANS OF DISCONNECTION FOR THE LINE-SIDE TAP POINT OF CONNECTION (LOC. ON EXTERIOR) PE CB2 20A CB3 20A F1-2 70A N ENVOY NEMA 3R JUNCTION BOX (LOC. ON ROOF) TRANSITION FROM #12 ENPHASE TRUNK CABLE TO #10 THWN-2, CU CONDUCTORS TO BE RAN INSIDE 0.75" DIA. EMT CONDUIT 2 4 11 IN BRANCH CB4 20A 2 (N) ENPHASE IQ COMBINER 4 PANEL WITH INTEGRATED ENPHASE ENVOY NEMA 3R RATED, 1-ɸ, 240VAC (LOC. ON EXTERIOR) PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 SINGLE-LINE DIAGRAM PV-3NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS SCALE: A PV-3 SINGLE-LINE DIAGRAM N/A PV MODULE REF.TYP.MODULE STC POWER PTC POWER ISC IMP VOC VMP SERIES FUSE RATING PM1-38 38 REC SOLAR REC405AA PURE 405W 385.9W 10.3A 9.56A 48.9V 42.4V 25A MICROINVERTER REF.TYP.MICROINVERTER GROUND AC VOLTAGE MAX OCPD SIZE MAX OUTPUT POWER (CONTINUOUS)MAX AC CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-38 38 ENPHASE IQ8A-72-2-US INTEGRATED 240VAC 20A 349W 1.45A 15A 60VDC 97% OCPD SCHEDULE REF.TYP.POLES CURRENT RATING MAX. VOLTAGE CB1 (ENPHASE BRANCH CIRCUIT)1 2 15A 240VAC CB2 (ENPHASE BRANCH CIRCUIT)1 2 20A 240VAC CB3 (ENPHASE BRANCH CIRCUIT)1 2 20A 240VAC CB4 (ENPHASE BRANCH CIRCUIT)1 2 20A 240VAC F1-2 (AC UTILITY DISCONNECT FUSES)2 N/A 70A 240VAC SCHEMATIC NOTES 1 THE FIRST AC CONNECTOR IN EACH MICROINVERTER BRANCH CIRCUIT IS SUITABLE AS A DISCONNECTING MEANS. 2 OUTPUT OF (4) FOUR MICROINVERTER BRANCH CIRCUITS SHALL BE BACKFED INTO A ENPHASE IQ COMBINER 4 PANEL FOR COMBINATION PURPOSES. PLEASE SEE THE OCPD SCHEDULE FOR THE BREAKER SIZES FOR EACH BRANCH CIRCUIT, RESPECTIVELY. 3 LINE SIDE TAP POINT OF INTERCONNECTION SHALL TAKE PLACE AS PER NEC 240.21(B)(1) & NEC 705.12(A). LENGTH OF TAP CONDUCTORS SHALL NOT EXCEED 10 FEET. SYSTEM SUMMARY BRANCH #1 BRANCH #2 BRANCH #3 BRANCH #4 INVERTERS PER BRANCH 5 11 11 11 MAX AC CURRENT 7.25A 15.95A 15.95A 15.95A MAX AC OUTPUT POWER 1,745W 3,839W 3,839W 3,839W ARRAY STC POWER 15,390W ARRAY PTC POWER 14,664W TOTAL MAX AC CURRENT 55.1A TOTAL MAX AC POWER 13,262W DISCONNECT SCHEDULE REF.FUSIBLE POLES CURRENT RATING MAX. VOLTAGE UTILITY DISCONNECT (DS1)YES 2 100A 240VAC CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS ID TYP DESCRIPTION CONDUCTOR CONDUIT NO. OF CURRENT CARRYING CNDRS. IN CNDT. FILL %RATED AMPS OCPD EGC TEMP. CORR. FACTOR @ 75°C TEMP. RATING FILL ADJ. FACTOR CONT. CURRENT MAX. CURRENT 75°C TERMINAL RATING CHECK SHALL EXCEED 1.25X CONT. CURRENT BASE AMPACITY @ 75°C TEMP. RATING (*90°C TEMP. RATING FOR WIRE ID-2) CONDITIONS OF USE (COU) @ 75°C TEMP. RATING 1 4 MICROINVERTER OUTPUT: MICROINVERTER TO JUNCTION BOX 12 AWG THWN-2 COPPER (ENPHASE IQ8A TRUNK CABLE) FREE AIR (DIRECT HOMERUN TO J-BOX LOCATED UNDER PV MODULE) N/A N/A 7.25A (BRANCH #1) 15.95A (BRANCH #2) 15.95A (BRANCH #3) 15.95A (BRANCH #4) N/A 6 AWG BARE COPPER 0.76 (51°C)1.0 7.25A (BRANCH #1) 15.95A (BRANCH #2) 15.95A (BRANCH #3) 15.95A (BRANCH #4) 9.07A (BRANCH #1) 19.94A (BRANCH #2) 19.94A (BRANCH #3) 19.94A (BRANCH #4) 25A > 19.94A PASS 40A (IN FREE AIR) 30.4A (IN FREE AIR) 2 1 MICROINVERTER OUTPUT (TRANSITIONED): JUNCTION BOX TO ENPHASE IQ COMBINER 4 10 AWG THWN-2 COPPER 0.75" DIA. EMT 8 (L1, L2) X 4 35.8% 7.25A (BRANCH #1) 15.95A (BRANCH #2) 15.95A (BRANCH #3) 15.95A (BRANCH #4) 15A (CB1) 20A (CB2) 20A (CB3) 20A (CB4) 10 AWG THWN-2 COPPER 0.76 (51°C)0.7 7.25A (BRANCH #1) 15.95A (BRANCH #2) 15.95A (BRANCH #3) 15.95A (BRANCH #4) 9.07A (BRANCH #1) 19.94A (BRANCH #2) 19.94A (BRANCH #3) 19.94A (BRANCH #4) 35A > 19.94A PASS 40A* (IN CONDUIT) 21.28A (IN CONDUIT) 3 1 COMBINED OUTPUT OF MICROINVERTERS: ENPHASE IQ COMBINER 4 TO UTILITY DISCONNECT (DS1) 4 AWG THWN-2 COPPER 1.00" DIA. SCH. 40 PVC 3 (L1, L2, N) X 1 34.3%55.1A 70A (F1-2) 100A (DS1) 8 AWG THWN-2 COPPER 1.0 (29°C)1.0 55.1A 68.88A 85A > 68.88A PASS 85A (IN CONDUIT) 85A (IN CONDUIT) 4 1 UTILITY DISCONNECT (DS1) OUTPUT: UTILITY DISCONNECT (DS1) TO LINE-SIDE TAP P.O.C. (TO BE MADE AS PER NEC 240.21(B)(1) & NEC 705.12(A)) 4 AWG THWN-2 COPPER 1.00" DIA. SCH. 40 PVC 3 (L1, L2, N) X 1 30.0%55.1A N/A 6 AWG BARE COPPER (RAN OUTSIDE OF CONDUIT) 1.0 (29°C)1.0 55.1A 68.88A 85A > 68.88A PASS 85A (IN CONDUIT) 85A (IN CONDUIT) ALL CONDUCTORS, OCPD SIZES AND TYPES SPECIFIED ACCORDING TO NEC ARTICLES 690.8(A)(1), NEC ARTICLE 240, AND NEC ARTICLE 690.7.B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN NEC 690.56(B) SITE OVERVIEW UTILITY AC DISCONNECT (LOC. ON EXTERIOR) MAIN SERVICE PANEL (LOC. ON INTERIOR) OVERALL SYSTEM RATED AC CURRENT PH O T O V O LT AI C S YS TE M A C D I S C O N N E C T OPERATING CURRENT OPERATING VOLTAGE AMPS VOLTS OVERALL SYSTEM RATED AC CURRENT1 NEC 690.14(C)(2) & NEC 690.54 55.1 240 IQ COMBINER PANEL (LOC. ON EXTERIOR) PV ARRAY M MM AC IQ PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 PLACARDS PV-4SCALE: 1 PV-4 PLACARDS N/A NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION NEED TO PROVIDE ADHESIVE FASTENED FIRE PLACARDS & REQUIREMENTS IRON RIDGE FLASHFOOT2 MOUNTING ATTACHMENT @ 72" O.C. SPANS REC SOLAR REC405AA PURE PV MODULE, TYP. IRON RIDGE XR-100 SERIES RACKING RAIL 2" X 4" RAFTER @ 24" O.C. 72" 6'-8"16'-10" 18" 3 8" 13'-5"20'-2" 30'-3"3'-4" 37' 24' 24" O.C. PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 ATTACHMENT PLAN PV-5SCALE: 1 PV-5 ATTACHMENT PLAN 1" = 4'NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS ROOF INFORMATION ROOF TYPE COMPOSITE SHINGLE PITCH 5:12 RAFTER SPACING 24" O.C. RAFTER DIMENSIONS 2" X 4" LAYOUT SPECIFICATIONS NUMBER OF MODULES 38 AREA 757 SQ. FT AZIMUTH 180° STRUCTURAL CALCULATIONS WIND EXPOSURE CATEGORY B RISK CATEGORY II DESIGN WIND SPEED 110 MPH DESIGN SNOW LOAD 15 PSF ATTACHMENT PLAN NOTES 1 ROOF MEMBERS AND PENETRATIONS TO BE DETERMINED IN THE FIELD. 2 THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 3 PLEASE SEE SHEETS PV-6A, PV-6B, AND PV-6C FOR DETAILS REGARDING THE MOUNTING ATTACHMENT TO BE USED, THE FLASHING TO BE USED, AS WELL AS THE RELEVANT INSTALLATION INSTRUCTIONS. 4 PLEASE SEE SHEET PV-11 FOR A STRUCTURAL CERTIFICATION LETTER FOR THE IRON RIDGE FLUSH MOUNT SYSTEM. LETTER IS STAMPED BY A STATE OF WASHINGTON REGISTERED PROFESSIONAL ENGINEER (PE).PV MODULES AND IRON RACKING SYSTEM HAVE A CLASS A FIRE RATING CLASSIFICATION.B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-6A IRON RIDGE FLASHFOOT2 MOUNTING DETAILS NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 MOUNTING DETAIL PV-6ANEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-6B IRON RIDGE FLASHFOOT2 MOUNTING DETAILS NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 MOUNTING DETAIL PV-6BNEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-6C IRON RIDGE FLASHFOOT2 INSTALLATION NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 INSTALLATION PV-6CNEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-7 FLUSH MOUNT RACKING DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 RACKING DATASHEET PV-7NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-8 PV MODULE DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 MODULE DATASHEET PV-8NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-9 MICROINVERTER DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 INVERTER DATASHEET PV-9NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-10 CLASS A FIRE RATING DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 CLASS A FIRE RATING PV-10NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-11 STATE OF WASHINGTON ENGINEERING LETTER (RACKING) NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 ENGINEERING LETTER PV-11NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-12 GROUNDING DETAILS (IRON RIDGE RACKING) NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 GROUNDING DETAILS PV-12NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-13 RAPID SHUTDOWN DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 RAPID SHUTDOWN PV-13NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION SCALE: 1 PV-14 ENPHASE IQ COMBINER 4 DATASHEET NTS PROJECT NO: DRAWN BY: DATE: GSD-20221006-181135 SCM 10/6/2022 IQ COMBINER 4 PV-14NEW GRID-TIED SYSTEM 15.39kWVONG RESIDENCE5117 NE 7TH PLRENTON, WA 98059PHONE: LICENSE NO. CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. (206) 462-1103 SOLTERRA GLOBAL, LLC. SOLTEGL838BS B22005501RECEIVED 10/17/2022 striplett BUILDING DIVISION