HomeMy WebLinkAboutP_Electrical One Line Diagram_Van Flander_20221205_V1 LEGENDGROUNDINGBREAKERSOLAR MODULEJUNCTION BOXPRODUCTIONMETERNET METERFUSED ACDISCONNECTUNFUSED ACDISCONNECTMICROINVERTERDC OPTIMIZERMIFEEDER SCHEDULEENPHASE Q CABLES + #6 BARE EGC IN OPEN AIR(6) #12 THWN-2 +(1) #10 GND IN 3/4" EMT NOT USED(2) #8 THWN-2 + (1) #8 THWN-2 NEUT + (1) #10 GND IN 1" EMT NOT USED(2) #6 THWN-2 + (1) #6 THWN-2 NEUT + (1) #6 GEC IN 1" PVC NOT USED NOT USED20A50ASUPPLY CALCULATIONSMAIN PV BUSBAR TOTAL SUPPLY% 0A0%≤100%NOT USEDNOT USEDNOT USEDNOT USEDNOT USEDLOADCENTER200A MAIN200A BUSUTILITYSERVICEROOFEXISTINGM21314FLAG NOTES:200A42EXTERIOR5670A ACDISCONNECT50A200200MAIN BONDING JUMPER, LINE SIDE TAP BEFORE MAINBREAKER IN COMPLIANCE WITH NEC 2020 705.11MONITORING DEVICE CT LEADS, (2) 18 AWG IN 1/2" EMTIQ COMBINER 10A 20A 20A 20A3STRING OF9 MODULESSTRING OF8 MODULESSTRING OF13 MODULES2IQGATEWAY111MIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMIMISOLAR PV SYSTEM DETAILS TOTAL MODULE(S)30 TOTAL DC POWER 11.55kW OPERATING VOLTAGE 240V INVERTER MODEL MAX DC IN MAX CURRENT IN MAX AC OUT MAX CURRENT OUTCONDUIT CURRENT CALCULATIONS #12 THWN-2 ALLOWABLE CURRENT30A CURRENT CARRYING CONDUCTORS6 ADJUSTMENT FACTOR80% ADJUSTED ALLOWED CURRENT 24A STRING MAX AC OUTPUT CURRENT15.7A MODULE MODEL VMPP IMPP VOC ISC VOC TEMP COEFF MIN DESIGN TEMPINVERTER DATA MAX AC POWER OUT8.7kVAPV STRING SIZING DETAILS STRING MAX MICROS 13 STRING MAX AC CONTINUOUS OUTPUT15.73A SYSTEM MICROINVERTER TOTAL30 SYSTEM MAX AC CONTINUOUS OUTPUT36.3AMODULE DATAMission Solar MSE385SX5R36.93V10.42A45.03V10.97A-0.259%/°C-40°CENPHASE IQ8PLUS-72-2-US60V15A290VA1.21AJOVERCURRENT PROTECTION MAX AC OUTPUT125% SAFETYOCPD SIZE▫ PV STRING MAX19.7A▫ PV TOTAL45.4AJPMMI122A33A455A1.5 DAYSTHIS DRAWING IS THE PROPERTY OF PUGET SOUND SOLAR. USE, DUPLICATION AND DISTRIBUTION WITHOUT THE OWNER'S PERMISSION IS PROHIBITED. DRAWINGS NOT TO BE USED FOR CONSTRUCTION UNLESS ISSUED FOR CONSTRUCTION BY PUGET SOUND SOLAR. SCALES STATED ON DRAWINGS ONLY VALID IF PLOTTED ANSI A 8-1/2" X 11"DESCRIPTIONREVDATEPRELIMINARY DESIGNDRAWN BYCHECKED BYPuget Sound Solar 805 Rainier Ave SSeattle, WA 98144Tel: 206-706-1931VERSION: Van Flander, PLOT DATE: Thursday, November 10, 2022 2:42:50 PM 0PROJECT #: 17846SALES: JEFF ROSSPM: BILL ULSUNDPM CELL: (253) 951-038511/10/22 ABBUVAN FLANDER, KEVIN 600 Pasco Pl NEELECTRICAL ONE LINEDIAGRAMRenton, WA 98059PV-102RECEIVED12/05/2022 striplettBUILDING DIVISIONB22006281APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNT IL AFTER FINAL INSPECT ION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERT IFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORD INANCES,OR OTHER REGULAT IONS ENFORCED BY THIS CITY.DATE: 12/07/2022