HomeMy WebLinkAboutP_PlanS_Van Flander_20221205_V1SPECIFICATIONSMODULE: (30) MISSION SOLAR 385W MODULE 66 CELL, 41.1" x 75.1"INVERTER: ENPHASE IQ8PLUS-72-2-US (30) IQ8+ MICROINVERTERSMIN. FLASHINGS: (54) / 5/16" LAG BOLTSRACKING: IRONRIDGE XR100MONITORING: ENVOYLOAD CENTERNET METERMLCNOTESNFIRE SETBACKS 18"LEGENDPVSPENPHASE COMBINER PANELAC DISCONNECT34'-6 1/4"4:12,179°3 DAYS4:12,269°24'-2"13'-9 1/2"MLCPVSP4:12,269°SCALE: NOT TO SCALETHIS DRAWING IS THE PROPERTY OF PUGET SOUND SOLAR. USE, DUPLICATION AND DISTRIBUTION WITHOUT THE OWNER'S PERMISSION IS PROHIBITED. DRAWINGS NOT TO BE USED FOR CONSTRUCTION UNLESS ISSUED FOR CONSTRUCTION BY PUGET SOUND SOLAR. SCALES STATED ON DRAWINGS ONLY VALID IF PLOTTED ANSI A 8-1/2" X 11"DESCRIPTIONREVDATEPRELIMINARY DESIGNDRAWN BYCHECKED BYPuget Sound Solar 805 Rainier Ave SSeattle, WA 98144Tel: 206-706-1931VERSION: Van Flander, PLOT DATE: Thursday, November 10, 2022 2:42:39 PM 0PROJECT #: 17846SALES: JEFF ROSSPM: BILL ULSUNDPM CELL: (253) 951-038511/10/22 ABBUVAN FLANDER, KEVIN 600 Pasco Pl NERESIDENTIAL LAYOUTRenton, WA 98059PV-101RECEIVED12/05/2022 striplettBUILDING DIVISIONB22006281THE CONTRACTOR IS RESPONSIBLE FORPROVIDING ATTIC ACCESS AND A SAFE AND APPROPRIATELY SIZED LADDERFOR INSPECTION OF ALL WORKNOTICE: SCHEDULE A ROUGH INSPECTION TO VERIFY PROPER GROUNDING BEFORE ARRAYS ARE INSTALLEDPLEASE PROVIDE REQUIRED ITEMS ON THE JOB FORFIELD INSPECTOR TO VERIFY: 1. PV EQUIPMENT LOCATION & FIRE LABEL PLACEMENT TABLE2. FIRE PLACARD & REQUIREMENTREVIEWEDPaul Wong 12/06/2022BUILDING DIVISIONTHIS SET OF REVIEWED PLANS MUST BE MADE AVAILABLE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. Note: This review is for the non-structural review onlyAPPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 12/07/2022 AERIAL VIEW ADDRESS:600 PASCO PL NE, RENTON,WA 98059 47.492130, -122.139720APN:947-79-40-110 CUSTOMER INFORMATION NAME:KEVIN VAN FLANDER DATE:11/28/2022 SCALE:AS NOTED REV:A AHJ:WA - CITY OF RENTON UTILITY:PUGET SOUND ENERGY PRN NUMBER:PGT-68979 DRAFTED BY :S.HARISH QC'ED BY :A.AJITH PAPER SIZE:17"X11" .\pgt logo.png PM INFO:BILL ULSUND /(253) 951-0385 MOUNTING DETAIL S-01 INSTALLATION NOTES 1. STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATEDAND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTORWHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENTTO THE STRUCTURE IS REQUIRED. 2. ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3. LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4. ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5. ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7. THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL OR BUILDING ROOF VENTS ROOF ACCESS PATHWAYS AND SETBACKS: 1204.2.1 SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3BUILDINGSSOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3BUILDINGS SHALL COMPLY WITH SECTIONS  1204.2.1.1THROUGH 1204.2.1.3.EXCEPTIONS: 1. THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURESDESIGNED AND CONSTRUCTED IN ACCORDANCE WITHTHE INTERNATIONAL RESIDENTIAL CODE. 2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITHSLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LESS. 1204.2.1.1 PATHWAYS TO RIDGE NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ONSEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONEPATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAYSIDE OF THE ROOF. FOR EACH ROOF PLANE WITH APHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE(914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGESHALL BE PROVIDED ON THE SAME ROOF PLANE AS THEPHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE ORSTRADDLING THE SAME AND ADJACENT ROOF PLANES. 1204.2.1.2 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESSOF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESSTHAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDESOF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC  ARRAYSOCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTALROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLEDWITHIN THE DWELLING IN ACCORDANCE WITH SECTION903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OFTHE FOLLOWING: 1. FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT ORLESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOTLESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTHSIDES OF A HORIZONTAL RIDGE. 2. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OFNOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ONBOTH SIDES OF A HORIZONTAL RIDGE. 1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGSSHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT ISBELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. APATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALLBE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUEOPENING. ALUMINIUM RAILS ARRAY MP-01 SCALE:1"=10'-0" NOTE:PENETRATIONS ARE STAGGERED SITE INFORMATION - WIND SPEED: 98 MPH AND SNOW LOAD: 25 PSF SR. NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 179 °18°21 450.1 COMPOSITIONSHINGLE NANOMOUNTDECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0" MP-02 269 °18°7 150.0 COMPOSITION SHINGLE NANOMOUNT DECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0" MP-03 269 °18°2 42.9 COMPOSITIONSHINGLE NANOMOUNTDECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0" ARRAY MP-02 ARRAY MP-03 1'-6" 1'-6" 6'B22006281RECEIVED 12/05/2022 striplett BUILDING DIVISION MODULE END CLAMPMID CLAMPMODULE ADDRESS:600 PASCO PL NE, RENTON,WA 98059 47.492130, -122.139720APN:947-79-40-110 CUSTOMER INFORMATION NAME:KEVIN VAN FLANDER DATE:11/28/2022 SCALE:AS NOTED REV:A AHJ:WA - CITY OF RENTON UTILITY:PUGET SOUND ENERGY PRN NUMBER:PGT-68979 DRAFTED BY :S.HARISH QC'ED BY :A.AJITH PAPER SIZE:17"X11" .\pgt logo.png PM INFO:BILL ULSUND /(253) 951-0385 STRUCTURAL DETAIL S-02 DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 30 49 1470.00 MID-CLAMP 44 0.050 2.20 END-CLAMP 32 0.050 1.60 RAIL LENGTH 223 0.680 151.64 SPLICE BAR 8 0.360 2.88 NANOMOUNTDECKING 56 1.35 75.60 MICRO-INVERTER 30 2.38 71.40 TOTAL WEIGHT OF THE SYSTEM (LBS)1775.32 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)643.04 WEIGHT PER SQ. FT.(LBS)2.76 WEIGHT PER PENETRATION (LBS)31.70 MID-CLAMP AND END-CLAMP ANATOMY GROUNDING LUG MID CLAMPASSEMBLY MODULE FRAME RAIL MODULE TO MODULE & MODULE TO RAIL GROUNDING MID-CLAMP SCALE: NTS GROUNDING DETAILS IRONRIDGE RAIL IRONRIDGE INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS RAIL TO RAIL T-BOLT 2 X 4 RAFTERS @2'-0" SPACING COMPOSITION SHINGLE ROOF MODULE LOAD BEARING WALL SCALE:NTS ROOF FRAMING DETAILS MODULES DATA MISSION SOLAR MSE385SX5R 385W MODULE DIMS 75.1 "x41.1 "x1.6 " LAG SCREWS (4)3" SELF-TAPPING SCREW ATTACHMENT DETAIL-NANOMOUNT DECKING NANOMOUNT DECKINGSOLAR MODULE XR100 RAIL (4)3" SELF-TAPPING SCREW 6" MAX SCALE:NTS (4)3" SELF-TAPPING SCREW DECK B22006281RECEIVED 12/05/2022 striplett BUILDING DIVISION ROOF STRUCTURE SECURE TO ROOF STRUCTURE