HomeMy WebLinkAboutP_PlanS_Van Flander_20221205_V1SPECIFICATIONSMODULE: (30) MISSION SOLAR 385W MODULE 66 CELL, 41.1" x 75.1"INVERTER: ENPHASE IQ8PLUS-72-2-US (30) IQ8+ MICROINVERTERSMIN. FLASHINGS: (54) / 5/16" LAG BOLTSRACKING: IRONRIDGE XR100MONITORING: ENVOYLOAD CENTERNET METERMLCNOTESNFIRE SETBACKS 18"LEGENDPVSPENPHASE COMBINER PANELAC DISCONNECT34'-6 1/4"4:12,179°3 DAYS4:12,269°24'-2"13'-9 1/2"MLCPVSP4:12,269°SCALE: NOT TO SCALETHIS DRAWING IS THE PROPERTY OF PUGET SOUND SOLAR. USE, DUPLICATION AND DISTRIBUTION WITHOUT THE
OWNER'S PERMISSION IS PROHIBITED. DRAWINGS NOT TO BE USED FOR CONSTRUCTION UNLESS ISSUED FOR
CONSTRUCTION BY PUGET SOUND SOLAR. SCALES STATED ON DRAWINGS ONLY VALID IF PLOTTED ANSI A 8-1/2" X 11"DESCRIPTIONREVDATEPRELIMINARY DESIGNDRAWN BYCHECKED BYPuget Sound Solar 805 Rainier Ave SSeattle, WA 98144Tel: 206-706-1931VERSION: Van Flander, PLOT DATE: Thursday, November 10, 2022 2:42:39 PM
0PROJECT #: 17846SALES: JEFF ROSSPM: BILL ULSUNDPM CELL: (253) 951-038511/10/22
ABBUVAN FLANDER, KEVIN
600 Pasco Pl NERESIDENTIAL LAYOUTRenton, WA 98059PV-101RECEIVED12/05/2022 striplettBUILDING DIVISIONB22006281THE CONTRACTOR IS RESPONSIBLE FORPROVIDING ATTIC ACCESS AND A SAFE AND APPROPRIATELY SIZED LADDERFOR INSPECTION OF ALL WORKNOTICE: SCHEDULE A ROUGH INSPECTION TO VERIFY PROPER GROUNDING BEFORE ARRAYS ARE INSTALLEDPLEASE PROVIDE REQUIRED ITEMS ON THE JOB FORFIELD INSPECTOR TO VERIFY: 1. PV EQUIPMENT LOCATION & FIRE LABEL PLACEMENT TABLE2. FIRE PLACARD & REQUIREMENTREVIEWEDPaul Wong 12/06/2022BUILDING DIVISIONTHIS SET OF REVIEWED PLANS MUST BE MADE AVAILABLE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. Note: This review is for the non-structural review onlyAPPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 12/07/2022
AERIAL VIEW
ADDRESS:600 PASCO PL NE, RENTON,WA 98059
47.492130, -122.139720APN:947-79-40-110
CUSTOMER INFORMATION
NAME:KEVIN VAN FLANDER
DATE:11/28/2022
SCALE:AS NOTED REV:A
AHJ:WA - CITY OF RENTON
UTILITY:PUGET SOUND ENERGY
PRN NUMBER:PGT-68979
DRAFTED BY :S.HARISH
QC'ED BY :A.AJITH PAPER SIZE:17"X11"
.\pgt logo.png
PM INFO:BILL ULSUND /(253) 951-0385
MOUNTING DETAIL
S-01
INSTALLATION NOTES
1. STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATEDAND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTORWHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENTTO THE STRUCTURE IS REQUIRED.
2. ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR.
3. LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4. ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY.
5. ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING).
7. THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL OR BUILDING ROOF VENTS
ROOF ACCESS PATHWAYS AND SETBACKS:
1204.2.1 SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3BUILDINGSSOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3BUILDINGS SHALL COMPLY WITH SECTIONS 1204.2.1.1THROUGH 1204.2.1.3.EXCEPTIONS: 1. THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURESDESIGNED AND CONSTRUCTED IN ACCORDANCE WITHTHE INTERNATIONAL RESIDENTIAL CODE.
2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITHSLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LESS.
1204.2.1.1 PATHWAYS TO RIDGE
NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ONSEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONEPATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAYSIDE OF THE ROOF. FOR EACH ROOF PLANE WITH APHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE(914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGESHALL BE PROVIDED ON THE SAME ROOF PLANE AS THEPHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE ORSTRADDLING THE SAME AND ADJACENT ROOF PLANES.
1204.2.1.2 SETBACKS AT RIDGE
FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESSOF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESSTHAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDESOF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYSOCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTALROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE.
1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE
WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLEDWITHIN THE DWELLING IN ACCORDANCE WITH SECTION903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OFTHE FOLLOWING:
1. FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT ORLESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOTLESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTHSIDES OF A HORIZONTAL RIDGE. 2. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OFNOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ONBOTH SIDES OF A HORIZONTAL RIDGE.
1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS
PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGSSHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT ISBELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. APATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALLBE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUEOPENING.
ALUMINIUM RAILS
ARRAY MP-01
SCALE:1"=10'-0"
NOTE:PENETRATIONS ARE STAGGERED
SITE INFORMATION - WIND SPEED: 98 MPH AND SNOW LOAD: 25 PSF
SR.
NO AZIMUTH PITCH NO. OF
MODULES
ARRAY AREA
(SQ. FT.)ROOF TYPE ATTACHMENT ROOF
EXPOSURE FRAME TYPE FRAME
SIZE
FRAME
SPACING
MAX RAIL
SPAN
OVER
HANG
MP-01 179 °18°21 450.1 COMPOSITIONSHINGLE NANOMOUNTDECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0"
MP-02 269 °18°7 150.0 COMPOSITION
SHINGLE
NANOMOUNT
DECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0"
MP-03 269 °18°2 42.9 COMPOSITIONSHINGLE NANOMOUNTDECKING ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0"
ARRAY MP-02
ARRAY MP-03
1'-6"
1'-6"
6'B22006281RECEIVED
12/05/2022 striplett
BUILDING DIVISION
MODULE
END CLAMPMID CLAMPMODULE
ADDRESS:600 PASCO PL NE, RENTON,WA 98059
47.492130, -122.139720APN:947-79-40-110
CUSTOMER INFORMATION
NAME:KEVIN VAN FLANDER
DATE:11/28/2022
SCALE:AS NOTED REV:A
AHJ:WA - CITY OF RENTON
UTILITY:PUGET SOUND ENERGY
PRN NUMBER:PGT-68979
DRAFTED BY :S.HARISH
QC'ED BY :A.AJITH PAPER SIZE:17"X11"
.\pgt logo.png
PM INFO:BILL ULSUND /(253) 951-0385
STRUCTURAL DETAIL
S-02
DEAD LOAD CALCULATIONS
BOM QUANTITY LBS/UNIT TOTAL WEIGHT
(LBS)
MODULES 30 49 1470.00
MID-CLAMP 44 0.050 2.20
END-CLAMP 32 0.050 1.60
RAIL LENGTH 223 0.680 151.64
SPLICE BAR 8 0.360 2.88
NANOMOUNTDECKING 56 1.35 75.60
MICRO-INVERTER 30 2.38 71.40
TOTAL WEIGHT OF THE SYSTEM (LBS)1775.32
TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)643.04
WEIGHT PER SQ. FT.(LBS)2.76
WEIGHT PER PENETRATION (LBS)31.70
MID-CLAMP AND END-CLAMP ANATOMY
GROUNDING LUG
MID CLAMPASSEMBLY
MODULE
FRAME
RAIL
MODULE TO MODULE & MODULE TO RAIL
GROUNDING MID-CLAMP
SCALE: NTS
GROUNDING DETAILS
IRONRIDGE RAIL
IRONRIDGE INTERNAL SPLICE
SELF-DRILLING SCREW
SCALE: NTS
RAIL TO RAIL
T-BOLT
2 X 4 RAFTERS
@2'-0" SPACING
COMPOSITION SHINGLE ROOF
MODULE
LOAD BEARING WALL SCALE:NTS
ROOF FRAMING DETAILS
MODULES DATA
MISSION SOLAR MSE385SX5R 385W
MODULE DIMS 75.1 "x41.1 "x1.6 "
LAG SCREWS (4)3" SELF-TAPPING
SCREW
ATTACHMENT DETAIL-NANOMOUNT DECKING
NANOMOUNT DECKINGSOLAR MODULE
XR100 RAIL
(4)3" SELF-TAPPING SCREW
6" MAX
SCALE:NTS
(4)3" SELF-TAPPING SCREW
DECK B22006281RECEIVED
12/05/2022 striplett
BUILDING DIVISION
ROOF STRUCTURE
SECURE TO
ROOF STRUCTURE