HomeMy WebLinkAbout161028 Vuecrest Arch Drawing_Review Stamped.pdfCONTECH PROJECT ID #521539
PRE-521539-010-MP-PRO-B
MULTI-PLATE SINGLE RADIUS ARCH
RENTON, WA
521539-INDEX
PAGE NUMBER PAGE TITLE
1 COVER SHEET
2 SITE PLAN
3 PLAN/PROFILE/SECTION
4-5 DETAILS
10/5/16
C STREAML SMITHERS AVE. SC ROADL35'-1"45'-3"R/WR/WR/WR/WE/PE/PE/PE/P80'-4" (OUT TO OUT LENGTH)
21'-0"
SPAN
21'-0" SPAN x 8'-10" RISE
10 GAGE, HOT-DIP GALVANIZED
MULTI-PLATE SINGLE RADIUS ARCH
CONCRETE FOOTING
(BY OTHERS)
MAZ
SCC
CHECKED:
DRAWN:
XXX
DESIGNED:
APPROVED:I:\MERLIN\PROJECT\ACTIVE\521500\521539\521539-010-MP\PROPOSAL\PRE-521539-010-MP-PRO-B.DWG 10/5/2016 4:00 PMSHEET NO.:
OF 5
XXX
3/7/2016
DATE:PROJECT No.:
521539
SEQ. No.:
010
PRE-521539-010-MP-PRO-B
2
PROPOSAL
CONTECH
DRAWINGREVISION DESCRIPTIONDATEMARK BY
1 10/5/2016 REV. NOTATIONS AND BACKFILL DETAIL SCC
800-338-1122 513-645-7000 513-645-7993 FAX
9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon which
the drawing is based and actual field conditions are encountered
as site work progresses, these discrepancies must be reported
to Contech immediately for re-evaluation of the design. Contech
accepts no liability for designs based on missing, incomplete or
inaccurate information supplied by others.
www.ContechES.com
SITE PLAN
SCALE: 1/8" = 1'-0"
STRUCTURAL PLATE
RENTON, WA
VUECREST
111 PI, MULTI-PLATE SINGLE RADIUS ARCH
21'-0" SPAN x 8'-10" RISE
10/5/16
80'-4" (OUT TO OUT LENGTH)
C STRUCTUREL
21'-0" SPAN
CONCRETE FOOTING
(BY OTHERS)
21'-0" SPAN x 8'-10" RISE
10 GAGE, HOT-DIP GALVANIZED
MULTI-PLATE SINGLE RADIUS ARCH
FLOW
8'-10" RISE
80'-4" (OUT TO OUT LENGTH)
21'-0" SPAN x 8'-10" RISE
10 GAGE, HOT-DIP GALVANIZED
MULTI-PLATE SINGLE RADIUS ARCH
FLOW
CONCRETE FOOTING
(BY OTHERS)
21'-0" SPAN 8'-10" RISER1
0
'
-
8
"
8'-0" MIN.
HEIGHT OF COVER
GRADE
(8'-10" RISE)4" MIN.8" MIN.
(21'-0" SPAN)
X" MIN.
REINFORCED CONCRETE
FOOTING (DESIGN
BY OTHERS)
MULTI-PLATE
ARCH
INSIDE OF
MULTI-PLATE ARCH
GROUT
1'-3"3'-0"
MAZ
SCC
CHECKED:
DRAWN:
XXX
DESIGNED:
APPROVED:I:\MERLIN\PROJECT\ACTIVE\521500\521539\521539-010-MP\PROPOSAL\PRE-521539-010-MP-PRO-B.DWG 10/5/2016 4:00 PMSHEET NO.:
OF 5
XXX
3/7/2016
DATE:PROJECT No.:
521539
SEQ. No.:
010
PRE-521539-010-MP-PRO-B
3
PROPOSAL
CONTECH
DRAWINGREVISION DESCRIPTIONDATEMARK BY
1 10/5/2016 REV. NOTATIONS AND BACKFILL DETAIL SCC
STRUCTURAL PLATE
RENTON, WA
VUECREST
111 PI, MULTI-PLATE SINGLE RADIUS ARCH
21'-0" SPAN x 8'-10" RISE
800-338-1122 513-645-7000 513-645-7993 FAX
9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon which
the drawing is based and actual field conditions are encountered
as site work progresses, these discrepancies must be reported
to Contech immediately for re-evaluation of the design. Contech
accepts no liability for designs based on missing, incomplete or
inaccurate information supplied by others.
www.ContechES.com
PLATE MAKE-UP: 3 @ 21Pi, 2 @ 24Pi
111 Pi Total
AREA= 139.2 SF
NOTES:
1. ALL DIMENSIONS ARE TO INSIDE OF CORRUGATION CREST,
UNLESS OTHERWISE NOTED.
2. ALL DIMENSIONS ARE SUBJECT TO MANUFACTURING
TOLERANCES.
BRIDGE PLAN
SCALE: 1/8" = 1'-0"
BRIDGE PROFILE
SCALE: 1/8" = 1'-0"
21'-0" SPAN x 8'-10" RISE MULTI-PLATE
SINGLE RADIUS ARCH
SCALE: 1/8" = 1'-0"
NOTES:
1) SIZE AND REINFORCING OF FOOTING TO BE CONTROLLED BY
SOIL-BEARING CAPACITY AND LOADING CONDITIONS.
DESIGNED BY OTHERS.
2) BLOCKING OR SHIMMING SIDE PLATES TO ACHIEVE AND
MAINTAIN PROPER BOTTOM SPAN AND SIDE RETURN
ANGLE MAY BE REQUIRED.
3) GROUT SHOULD BE NON-METALLIC, NON-SHRINK MATERIAL.
4) GROUT AND SHIMMING MATERIAL SHOULD NOT CONTAIN ANY
CORROSION-PROMOTING AGENTS.
SLOTTED FOOTING DETAIL
SCALE: N.T.S.
FINAL DESIGN (TBD)
10/5/16
NATURAL
UNDISTURBED
EMBANKMENT
COMPACTED NORMAL
ROAD FILL
5'-0"
MINIMUM LIMITS OF
COMPACTED NORMAL
ROAD FILL
5'-0"
H
LIFTS-COMPACTEDNORMAL ROAD FILLMINIMUM LIMITS OF COMPACTED SELECT
GRANULAR STRUCTURAL BACKFILL
NORMAL ROADFILL ABOVE
MIN. COVER LEVEL
INSIDE
MULTI-PLATE
ARCH
3'-0" MINIMUM COVER LEVEL**ADDITIONAL NOTES FOR SELECT GRANULAR FILL:
SATISFACTORY BACKFILL MATERIAL, PROPER PLACEMENT, AND COMPACTION ARE KEY
FACTORS IN OBTAINING MAXIMUM STRENGTH AND STABILITY.
THE BACKFILL MATERIAL SHOULD BE FREE OF ROCKS, FROZEN LUMPS, AND FOREIGN
MATERIAL THAT COULD CAUSE HARD SPOTS OR DECOMPOSE TO CREATE VOIDS.
BACKFILL MATERIAL SHOULD BE WELL GRADED GRANULAR MATERIAL THAT MEETS
THE REQUIREMENTS OF AASHTO M-145 FOR SOIL CLASSIFICATIONS A-1, A-2, A-3.
BACKFILL MUST BE REPLACED SYMMETRICALLY ON EACH SIDE OF THE STRUCTURE
IN 6" LOOSE LIFTS. EACH LIFT IS TO BE COMPACTED TO A MINIMUM OF 90% DENSITY
PER AASHTO T-180.
A HIGH PERCENTAGE OF SILT OR FINE SAND IN THE NATIVE SOILS SUGGESTS THE
NEED FOR A WELL GRADED GRANULAR BACKFILL MATERIAL TO PREVENT SOIL
MIGRATION.
SELECT GRANULAR FILL LIMITS.CRITICAL BACKFILL ZONE, PRESSURE ON SOIL GREATEST HERE.
INITIAL LIFTS OVER CROWN OF STRUCTURE AS INDICATED BY
SHADED AREA TO BE COMPACTED TO REQUIRED DENSITY
WITH HAND OPERATED EQUIPMENT OR WITH SMALL TRACTOR
(D-4 OR SMALLER) DRAWN EQUIPMENT.
NOTES:
1. ALL SELECT GRANULAR BACKFILL TO BE PLACED IN A BALANCED FASHION IN THIN LIFTS (6"-8" LOOSE TYPICALLY) AND COMPACTED
TO 90 PERCENT DENSITY PER AASHTO T-180. **
2. THE USE OF WALK BEHIND COMPACTION EQUIPMENT IS RECOMMENDED IN THE BACKFILL ZONE.
SECTION
℄
MAZ
SCC
CHECKED:
DRAWN:
XXX
DESIGNED:
APPROVED:I:\MERLIN\PROJECT\ACTIVE\521500\521539\521539-010-MP\PROPOSAL\PRE-521539-010-MP-PRO-B.DWG 10/5/2016 4:00 PMSHEET NO.:
OF 5
XXX
3/7/2016
DATE:PROJECT No.:
521539
SEQ. No.:
010
PRE-521539-010-MP-PRO-B
4
PROPOSAL
CONTECH
DRAWINGREVISION DESCRIPTIONDATEMARK BY
1 10/5/2016 REV. NOTATIONS AND BACKFILL DETAIL SCC
800-338-1122 513-645-7000 513-645-7993 FAX
9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon which
the drawing is based and actual field conditions are encountered
as site work progresses, these discrepancies must be reported
to Contech immediately for re-evaluation of the design. Contech
accepts no liability for designs based on missing, incomplete or
inaccurate information supplied by others.
www.ContechES.com
BACKFILL ZONE DETAIL
SCALE: N.T.S.
STRUCTURAL PLATE
RENTON, WA
VUECREST
111 PI, MULTI-PLATE SINGLE RADIUS ARCH
21'-0" SPAN x 8'-10" RISE
1
10/5/16
I - GENERAL
1.0 STANDARDS AND DEFINITIONS
1.1 STANDARDS - All standards refer to latest edition unless otherwise noted.
1.1.1 ASTM A-761 "Corrugated Steel Structural Plate, Zinc Coated for Field-Bolted Pipe,
Pipe-Arches and Arches" (AASHTO Designation M-167).
1.1.2 AASHTO Standard Specification for Highway Bridges - Section 12.
1.1.3 AASHTO Standard Specification for Highway Bridges - Section 26.
1.2 DEFINITIONS
1.2.2 Engineer - In these specifications the word "Engineer" shall
mean the Engineer of Record or Owner's designated engineering
representative.
1.2.3 Manufacturer - In these specifications the word "Manufacturer"
shall mean CONTECH Construction Products Inc. 800-338-1122
1.2.4 Contractor - In these specifications the word "Contractor" shall
mean the firm or corporation undertaking the execution of any
installation work under the terms of these specifications.
1.2.5 Approved - In these specifications the word "approved" shall
refer to the approval of the Engineer or his designated
representative.
1.2.6 As Directed - In these specifications the words "as directed"
shall refer to the directions to the Contractor from the Owner
or his designated representative.
2.0 GENERAL CONDITIONS
2.1 The Contractor shall furnish all labor, material and equipment and
perform all work and services except those set out and furnished by the
Owner, necessary to complete in a satisfactory manner the site
preparation, excavation, filling, compaction, grading as shown on the
plans and as described therein. This work shall consist of all mobilization
clearing and grading, grubbing, stripping, removal of existing material
unless otherwise stated, preparation of the land to be filled, filling of the
land, spreading and compaction of the fill, and all subsidiary work
necessary to complete the grading of the cut and fill areas to conform
with the lines, grades, slopes, and specifications. This work is to be
accomplished under the observation of the Owner or his designated
representative.
2.2 Prior to bidding the work, the Contractor shall examine, investigate and
inspect the construction site as to the nature and location of the work, and
the general and local conditions at the construction site, including without
limitation, the character of surface or subsurface conditions and obstacles
to be encountered on and around the construction site and shall make
such additional investigation as he may deem necessary for the planning
and proper execution of the work.
If conditions other than those indicated are discovered by the Contractor,
the Owner shall be notified immediately. The material which the
Contractor believes to be a changed condition shall not be disturbed so
that the owner can investigate the condition.
2.3 The construction shall be performed under the direction of the Engineer.
2.4 All aspects of the structure design and site layout including foundations, backfill,
end treatments and necessary scour consideration shall be performed by the Engineer.
Any installation guidance provided herein shall be endorsed by the
Engineer or superceded by the Engineer's plans and specifications.
SPECIFICATIONS FOR MANUFACTURE AND INSTALLATION OF CONTECH MULTI-PLATE® SINGLE RADIUS ARCH
II - MULTI-PLATE SINGLE RADIUS ARCH.
1.0 GENERAL
1.1 Manufacturer shall fabricate the MP Single Radius Arch culvert as shown on the plans.
Fabrication shall conform to the requirements of ASTM A-761 and shall consist of
plates, fasteners, and appurtenant items.
Plate thickness, end treatment and type of invert and foundation shall be as indicated
on the plans. All manufacturing processes including corrugating, punching, curving
and required galvanizing shall be performedwithin the United States of America.
1.2 The contractor shall verify all field dimensions and conditions prior to ordering materials.
2.0 DIMENSIONS
2.1 The proposed structure shall be a MP Single Radius Arch with the following
dimensions:
Span: 21'-0" Rise: 8'-10"
Gage: 10
2.2 All plan dimensions on the contract drawings are measured in a true horizontal plan
unless otherwise noted.
3.0 ASSEMBLY AND INSTALLATION
3.1 Bolts and nuts shall conform to the requirements of ASTM A-449. The structure shall
be assembled in accordance with the plate layout drawings provided by the
manufacturer and per the manufacturer's recommendations.
Bolts shall be tightened using an applied torque of between 100 and 300 ft.-lbs.
3.2 The structure shall be installed in accordance with the plans and specifications, the
manufacturer's recommendations, and AASHTO Standard Specification for Highway
Bridges - Section 26.
3.3 Trench excavation shall be made in embankment material that is structurally adequate.
The trench width shall be shown on the plans. Poor quality in situ embankment
material must be removed and replaced with suitable backfill as directed by the
Engineer.
3.4 Bedding preparation is critical to both structure performance and service life. The bed
should be constructed to uniform line and grade to avoid distortions that may create
undesirable stresses in the structure and/or rapid deterioration of the roadway. The bed
should be free of rock formations, protruding stones, frozen lumps, roots, and other
foreign matter that may cause unequal settlement.
3.5 Bedding shall provide a minimum of 4,000 psf bearing capacity. Foundation details for
bearing capacity less than 4,000 psf shall be approved by the Engineer.
3.6 The structure shall be assembled in accordance with the Manufacturer's instructions.
All plates shall be unloading and handled with reasonable care. Plates shall not be
rolled or dragged over gravel rock and shall be prevented from striking rock or other
hard objects during placement in trench or on bedding.
When assembled on a cast in place spread footing, the structure shall be assembled in
the footing starting at the upstream end. When assembled on a full invert or on flexible
footing pads, the invert or footing pad shall be placed starting at the downstream end.
The structure shell shall be assembled on the invert or footing pad starting at the inlet
end. Circumferential seams shall be installed with the plate laps shingled downstream
as viewed from the inside of the structure.
The structure shall be backfilled using select granular fill* that meets
the requirements of AASHTO M-145 for soil classifications A-1, A-2 or A-3.
Backfill must be placed symmetrically on each side of the structure in 6 to 8 inch loose
lifts. Each lift shall be compacted to a minimum of 90 percent density per
AASHTO T-180.
3.7 Construction loads that exceed highway load limits are not allowed to cross the
structure without approval from the Engineer.
Normal highway traffic is not allowed to cross the structure until the structure has
been backfilled and paved. If the road is unpaved, cover allowance to accommodate
rutting shall be as directed by the Engineer.
GROUP CLASSIFICATION
Sieve Analysis Percent Passing
No. 10 (2.000 mm)
No. 40 (0.425 mm)
No. 200 (0.075 mm)
Characteristics of Fraction
A-1 A-2 A-3*
Liquid Limits
Plasticity Index
Usual Materials
50 max.
----
51 max.
----
25 max.35 max.10 max.
---- ----40 max.
6 max.10 max. Non Plastic
Gravel or Sand
With Silt or clay
Stone Fragment,
Gravel and Sand Sand
Adapted from AASHTO M-145
----
----
Passing No. 40 (0.425 mm)
* Fine beach sands, windblown sands, stream deposited sands, etc., exhibiting fine, rounded
particles and typically classified by AASHTO M-145 as A-3 material should be avoided.
*SELECT GRANULAR FILL
MAZ
SCC
CHECKED:
DRAWN:
XXX
DESIGNED:
APPROVED:I:\MERLIN\PROJECT\ACTIVE\521500\521539\521539-010-MP\PROPOSAL\PRE-521539-010-MP-PRO-B.DWG 10/5/2016 4:00 PMSHEET NO.:
OF 5
XXX
3/7/2016
DATE:PROJECT No.:
521539
SEQ. No.:
010
PRE-521539-010-MP-PRO-B
5
PROPOSAL
CONTECH
DRAWINGREVISION DESCRIPTIONDATEMARK BY
1 10/5/2016 REV. NOTATIONS AND BACKFILL DETAIL SCC
800-338-1122 513-645-7000 513-645-7993 FAX
9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069
The design and information shown on this drawing is provided
as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this
drawing, nor any part thereof, may be used, reproduced or
modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for
such use.
If discrepancies between the supplied information upon which
the drawing is based and actual field conditions are encountered
as site work progresses, these discrepancies must be reported
to Contech immediately for re-evaluation of the design. Contech
accepts no liability for designs based on missing, incomplete or
inaccurate information supplied by others.
www.ContechES.com
STRUCTURAL PLATE
RENTON, WA
VUECREST
111 PI, MULTI-PLATE SINGLE RADIUS ARCH
21'-0" SPAN x 8'-10" RISE
1
10/5/16