Loading...
HomeMy WebLinkAboutEX_05_P_Chase_Plan_SetLAO57"x30"6'-2" HOLDENTRANCE 2 (STREET FACING)LIVING ROOMATM1AHDSOL. #3 - 75"8'-6"8'-6"JAN.LOUNGERESTROOM 2RESTROOM 1DATAMSTCR1AST2F.D.ELEC. PNL.ATM257"x30"6'-2" HOLDATMICR140"COMMUNITY WALLSOL. #7 - 32"BOOTH 2BOOTH 1CONFERENCE 3PCS 4PCS 5PCS 6PCS 7PCS 8COPY RMEQUIP/ WORK RMMANUALTELLERSTATIONENTRANCE 1(PARKING)108TH AVENUESE PETROVISKY STREETVESTIBULE 1VESTIBULE 243'-0"66'-4"A2.01A2.02A2.1111/09/2022CBR22002.0PROJECT INFORMATION BLOCKJOB #DATE:DRAWN BY:CHECKED BY:MODELSHEET TITLESHEET NUMBERISSUEDATEDESCRIPTIONARCHITECT/ ENGINEER OF RECORDPMASISSUED FOR PRE-APP11/09/22 DRAWING STANDARDS v20.5These drawings and specifications are the confidential and proprietary propertyof JP Morgan Chase and shall not be copied or reproduced without writtenauthorization. The contract documents were prepared for use on this specificsite in conjunction with its issue date and are not suitable for use on a differentsite or at a later time. Use of these drawings for reference or example onanother project requires the services of properly licensed architects andengineers. Reproduction of the contract documents for reuse on anotherproject is not authorized.PREPARED FOR: CHASE # 48200R002273 LINEAR MEDIUM (STANDARD PALETTE) 17426 BENSON DRIVE RENTON, WA 980556930 Destiny Drive, #100Rocklin, CA. 95677PROPOSEDFLOOR PLANA1.01A1.01/4 = 1'-0"PROPOSED FLOOR PLANEXHIBIT 5RECEIVED12/21/2022 JDingPLANNING DIVISIONDocuSign Envelope ID: AA4FA6BA-AA72-4A92-A78C-D1916105F712 Lobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedLobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedADDRESST.O. SLAB0'-0"T.O. PARAPET+ 19'-4"T.O. PARAPET+ 21'-6"B.O. OVERHANG+ 10'-0"RC-1FC-1ST-4RC-1FC-2FC-2FC-1ACM-1A-1A-2A-8A-3A-6A-4Lobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedLobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedADDRESST.O. SLAB0'-0"T.O. PARAPET+ 19'-4"T.O. PARAPET+ 21'-6"T.O. WINDOW+ 10'-0"T.O. PARAPET+ 17'-10"FC-2RC-1FC-1ST-4ACM-1A-1A-1A-2A-3A-5A-6A-4TOWER AT ANGLE1A2.01/4"=1'-0"EAST ELEVATION (FRONT)11/09/2022CBR22002.0PROJECT INFORMATION BLOCKJOB #DATE:DRAWN BY:CHECKED BY:MODELSHEET TITLESHEET NUMBERISSUEDATEDESCRIPTIONARCHITECT/ ENGINEER OF RECORDPMASISSUED FOR PRE-APP11/09/22 DRAWING STANDARDS v20.5These drawings and specifications are the confidential and proprietary propertyof JP Morgan Chase and shall not be copied or reproduced without writtenauthorization. The contract documents were prepared for use on this specificsite in conjunction with its issue date and are not suitable for use on a differentsite or at a later time. Use of these drawings for reference or example onanother project requires the services of properly licensed architects andengineers. Reproduction of the contract documents for reuse on anotherproject is not authorized.PREPARED FOR: CHASE # 48200R002273 LINEAR MEDIUM (STANDARD PALETTE) 17426 BENSON DRIVE RENTON, WA 980556930 Destiny Drive, #100Rocklin, CA. 956772A2.01/4"=1'-0"SOUTH ELEVATION (SIDE)PROPOSEDEXTERIORELEVATIONSA2.0EXTERIOR FINISH MATERIALSST-4CAST STONE- ROCKFACE FIELD UNITSMANUFACTURERCORONADO STONE PRODUCTSPRODUCTMANUFACTURED STONE VENEERCOLORCREAMFINISHCHISELED LIMESTONESIZE24" WIDE x 12" HIGH x 1" THICKGROUT1/4" NOMINAL JOINTS WITH FULL SMOOTH TOOLED NATURALOFF-WHITE PORTLAND CEMENT GROUTNOTESRUNNING BOND MANUFACTURED THIN STONE FIELD-CUTTO MAX. LENGTHS POSSIBLE WITH BUTTED AND LAPPEDINSIDE AND OUTSIDE CORNERS UTILIZINGMANUFACTURER'S FABRICATED RETURN CORNER PIECES-MITERED CORNERS ARE NOT ACCEPTABLE- PLACECONTROL JOINTS AS RECOMMENDED BY THEMANUFACTURER- REFER TO WALL SECTIONS AND DETAILSFC-1FIBER CEMENT PANEL- DARKMANUFACTURERNICHIHA FIBER CEMENTPRODUCTVINTAGEWOOD AWP 1818 (AVAILABLE AS AWP 3030 FORNON-PROTOTYPICAL PROJECTS)COLORBARKSIZE18" NOMINAL x 72" NOMINAL AND 120" NOMINALNOTESINCLUDE 3.5" MANUFACTURED CORNERS ANDMANUFACTURER'S "ESSENTIAL" FLASHING SYSTEM.FC-2FIBER CEMENT PANEL- LIGHTMANUFACTURERNICHIHA FIBER CEMENTPRODUCTVINTAGEWOOD AWP 3030 (AVAILABLE AS AWP 1818 FORNON-PROTOTYPICAL PROJECTS)COLORASHSIZE18" NOMINAL x 72" NOMINAL AND 120" NOMINALNOTESINCLUDE 3.5" MANUFACTURED CORNERS ANDMANUFACTURER'S "ESSENTIAL" FLASHING SYSTEM.RC-1ROOF COPINGMANUFACTURERPETERSEN ALUMINUM / PAC-CLADPRODUCTPAC-CONTINUOUSCOLORAGED BRONZEACM-1ALUMINUM COMPOSITE MATERIALMANUFACTURERALCOA ARCHITECTURAL PRODUCTSPRODUCTREYNOBONDCOLORDURAGLOSS 5000 CHASE PROGRAM "CHASE SILVER"EXTERIOR ELEVATION KEYNOTESA-1BLACK ANODIZED STOREFRONT SYSTEM - CLEAR GLAZINGA-2CLEAR ANODIZED STOREFRONT SYSTEM - CLEAR GLAZINGA-3ACM METAL PANELA-4ENTRANCE CANOPY:SHOP FABRICATED SITE-ASSEMBLED PRE-FINISHED BLACK CUSTOM ALUMINUMCANOPY UNIT WITH PREPPED ELECTRICAL OPENINGS AND INTEGRALDRAINAGE SYSTEM FASTENDED TO BUILDING STRUCTURE- MAPESARCHITECTURAL CANOPIES SUPER LUMIDECK WITH FLAT SOFFIT AND 12"FASCIA, OR APPROVED EQUALA-5METAL SUN SCREENA-6SIGNAGE BY SIGN VENDOR, UNDER SEPARATE PERMIT.A-7HOLLOW METAL DOORA-8SURFACE-MOUNT DECORATIVE LIGHT FIXTUREA-9SURFACE-MOUNT EMERGENCY LIGHT FIXTUREA-10GAS METERA-11ELECTRICAL EQUIPMENTEPT-2EXTERIOR PAINTMANUFACTURERSHERWIN-WILLIAMSPRODUCTMETALATEX ACRYLIC SEMI-GLOSSCOLORSW 7036 ACCESSIBLE BEIGEFINSHSEMI-GLOSSDocuSign Envelope ID: AA4FA6BA-AA72-4A92-A78C-D1916105F712 Lobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedLobby HoursMon - Sat SunDrive-up HoursMon - SatSun9:00 - 5:00Closed9:00 - 5:00ClosedADDRESST.O. SLAB0'-0"T.O. PARAPET+ 17'-6"T.O. PARAPET+ 19'-4"T.O. STOREFRONT+ 10'-0"ST-4RC-1FC-1FC-2RC-1A-1A-1A-6A-6A-4A-8TOWER AT ANGLET.O. SLAB0'-0"T.O. PARAPET+ 19'-4"T.O. PARAPET+ 21'-6"B.O. OVERHANG+ 10'-0"ST-4RC-1RC-1FC-1FC-1A-1A-7EPT-2A-11A-10A-9A-8PROPOSEDEXTERIORELEVATIONSA2.11A2.11/4"=1'-0"WEST ELEVATION (REAR)11/09/2022CBR22002.0PROJECT INFORMATION BLOCKJOB #DATE:DRAWN BY:CHECKED BY:MODELSHEET TITLESHEET NUMBERISSUEDATEDESCRIPTIONARCHITECT/ ENGINEER OF RECORDPMASISSUED FOR PRE-APP11/09/22 DRAWING STANDARDS v20.5These drawings and specifications are the confidential and proprietary propertyof JP Morgan Chase and shall not be copied or reproduced without writtenauthorization. The contract documents were prepared for use on this specificsite in conjunction with its issue date and are not suitable for use on a differentsite or at a later time. Use of these drawings for reference or example onanother project requires the services of properly licensed architects andengineers. Reproduction of the contract documents for reuse on anotherproject is not authorized.PREPARED FOR: CHASE # 48200R002273 LINEAR MEDIUM (STANDARD PALETTE) 17426 BENSON DRIVE RENTON, WA 980556930 Destiny Drive, #100Rocklin, CA. 956772A2.11/4"=1'-0"NORTH ELEVATION (SIDE)EXTERIOR FINISH MATERIALSST-4CAST STONE- ROCKFACE FIELD UNITSMANUFACTURERCORONADO STONE PRODUCTSPRODUCTMANUFACTURED STONE VENEERCOLORCREAMFINISHCHISELED LIMESTONESIZE24" WIDE x 12" HIGH x 1" THICKGROUT1/4" NOMINAL JOINTS WITH FULL SMOOTH TOOLED NATURALOFF-WHITE PORTLAND CEMENT GROUTNOTESRUNNING BOND MANUFACTURED THIN STONE FIELD-CUTTO MAX. LENGTHS POSSIBLE WITH BUTTED AND LAPPEDINSIDE AND OUTSIDE CORNERS UTILIZINGMANUFACTURER'S FABRICATED RETURN CORNER PIECES-MITERED CORNERS ARE NOT ACCEPTABLE- PLACECONTROL JOINTS AS RECOMMENDED BY THEMANUFACTURER- REFER TO WALL SECTIONS AND DETAILSFC-1FIBER CEMENT PANEL- DARKMANUFACTURERNICHIHA FIBER CEMENTPRODUCTVINTAGEWOOD AWP 1818 (AVAILABLE AS AWP 3030 FORNON-PROTOTYPICAL PROJECTS)COLORBARKSIZE18" NOMINAL x 72" NOMINAL AND 120" NOMINALNOTESINCLUDE 3.5" MANUFACTURED CORNERS ANDMANUFACTURER'S "ESSENTIAL" FLASHING SYSTEM.FC-2FIBER CEMENT PANEL- LIGHTMANUFACTURERNICHIHA FIBER CEMENTPRODUCTVINTAGEWOOD AWP 3030 (AVAILABLE AS AWP 1818 FORNON-PROTOTYPICAL PROJECTS)COLORASHSIZE18" NOMINAL x 72" NOMINAL AND 120" NOMINALNOTESINCLUDE 3.5" MANUFACTURED CORNERS ANDMANUFACTURER'S "ESSENTIAL" FLASHING SYSTEM.RC-1ROOF COPINGMANUFACTURERPETERSEN ALUMINUM / PAC-CLADPRODUCTPAC-CONTINUOUSCOLORAGED BRONZEACM-1ALUMINUM COMPOSITE MATERIALMANUFACTURERALCOA ARCHITECTURAL PRODUCTSPRODUCTREYNOBONDCOLORDURAGLOSS 5000 CHASE PROGRAM "CHASE SILVER"EXTERIOR ELEVATION KEYNOTESA-1BLACK ANODIZED STOREFRONT SYSTEM - CLEAR GLAZINGA-2CLEAR ANODIZED STOREFRONT SYSTEM - CLEAR GLAZINGA-3ACM METAL PANELA-4ENTRANCE CANOPY:SHOP FABRICATED SITE-ASSEMBLED PRE-FINISHED BLACK CUSTOM ALUMINUMCANOPY UNIT WITH PREPPED ELECTRICAL OPENINGS AND INTEGRALDRAINAGE SYSTEM FASTENDED TO BUILDING STRUCTURE- MAPESARCHITECTURAL CANOPIES SUPER LUMIDECK WITH FLAT SOFFIT AND 12"FASCIA, OR APPROVED EQUALA-5METAL SUN SCREENA-6SIGNAGE BY SIGN VENDOR, UNDER SEPARATE PERMIT.A-7HOLLOW METAL DOORA-8SURFACE-MOUNT DECORATIVE LIGHT FIXTUREA-9SURFACE-MOUNT EMERGENCY LIGHT FIXTUREA-10GAS METERA-11ELECTRICAL EQUIPMENTEPT-2EXTERIOR PAINTMANUFACTURERSHERWIN-WILLIAMSPRODUCTMETALATEX ACRYLIC SEMI-GLOSSCOLORSW 7036 ACCESSIBLE BEIGEFINSHSEMI-GLOSSDocuSign Envelope ID: AA4FA6BA-AA72-4A92-A78C-D1916105F712 DocuSign Envelope ID: AA4FA6BA-AA72-4A92-A78C-D1916105F712 DocuSign Envelope ID: AA4FA6BA-AA72-4A92-A78C-D1916105F712