Loading...
HomeMy WebLinkAbout20160674E003 Bethany Corner 2023-01-26 TESC 109.pdf www.aesgeo.com This document is considered DRAFT until reviewed and initialed by an AESI Project Manager Temporary Erosion and Sediment Control Monitoring DATE PROJECT NAME AESI PROJECT NO. TESC REPORT NO. 1/26/2023 Bethany Corner 20160674E003 109 LOCATION CITY MUNICIPALITY CSWGP 16451 111th Ave SE Renton Renton WAR307077 PREVIOUS SITE VISIT CLIENT/OWNER WEATHER 24 HOUR RAINFALL PAST WEEK RAINFALL 1/20/2023 Mark Seek (Tiger Mountain Homes) Cloudy, 40's 0.00" 0.30" AESI FIELD REP Catherine Ikeda AESI PROJECT MANAGER Matthew A. Miller, P.E. Catherine Ikeda QUALITY/CONDITION (SEE SWPPP FOR BMP LOCATIONS) CONSTRUCTION ENTRANCE SITE RESTRICTED ACCESS Asphalt pavement No WHEEL WASH SEDIMENT TRACK OUT N/A Some sediment trackout ROADWAY SURFACE CATCH BASIN Asphalt silt socks installed, along 165th St - need repair LIMITS BUFFER AREA STABILIZATION Silt fence Landscaping grass, bark SILT FENCING CONCRETE WORK (Sidewalks, curbing, foundation) Installed along N, S, and W perimeter - needs repairs None observed COVER MEARSURES OVERALL STRAW Fair N/A PLASTIC SHEETING HYDROSEED N/A Sidewalk planters CONVEYENCE CHANNEL CHECK DAMS N/A N/A STOCKPILE COVER PIPE SLOPE DRAINS N/A N/A LEVEL SPREADER LANDSCAPE/MULCH South side of site Sidewalk planters, actively landscaping SEDIMENT POND TRAP SEDIMENT POND INLET/OUTLET Detention vault N/A SEDIMENT POND SIDE SLOPES SURFACE WATER OBSERVATION (Creek, Wetland, or Lake) (Clear, Turbid, Sheen) Concrete (detention vault) turbid puddles WATER QUALITY SAMPLE TURBIDITY (NTU) pH OVERALL Yes 3 6.0 BMPs adequate SAMPLE LOCATION AREAS OF CONCERN SE of site: 111th Ave swale outfall Silt fence, silt socks CORRECTIVE ACTIONS repair silt fence, replace silt socks PAST CORRECTIVE ACTIONS None Is this site in compliance with the terms and conditions of the SWPP and CSWGP discharge Permit? Yes www.aesgeo.com TESC REPORT DATE CSWGP PROJECT NO. TESC REPORT NO. 1/26/2023 WAR307077 20130674E003 109 Sample Location Approximate Flow Turbidity NTU/Transparency pH Compliance 111th Ave Swale outfall 3 6.0 Yes ADDITIONAL COMMENTS: While onsite, AESI observed the silt fence to need repairs in some areas around the site. AESI recommended repairing the silt fence on the western perimeter by building 6 and replacing the silt socks in the catch basins on 165th St. Utility and sewer work were ongoing. AESI took a water sample from the 111th Ave swale outfall. The turbidity of the water came back at 3 NTU. This is in compliance with the SWPP.