Loading...
HomeMy WebLinkAboutR-412719DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 ', 4', 6', 12', OR 24- ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION 6 PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP', 17, STD. SPEC.9-05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15„ ' CORRUGATED POLYETHYLENE STORM SEWER PIPE ���0'CE sFFNo, NOTES: s res 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION. FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 1 / 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH 43 BAR EACH CORNER I i \I I HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER #3 BAR EACH SIDE �. #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20'. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2' MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9104.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN, 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED ATTHE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR #3 BAR EACH NON -SHRINK APPLICATIONS IN ACCORDANCE WITH CORNER 18" MIN. STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-D4.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS. RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION. ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 200.00 v�• PUBLIC WORKS APPR ED: '�„ DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 I work,ae DATE CATCH BASIN TYPE 1 C6.3 NTS DocuSign Envelope ID: 6EEC F586-602A-4E4A-B436-A317AA638878 25 1J4' 29 1A' BOLT -DOWN HOLE (TYP.) - 5/8 11 NO. SEE DETAIL AND NOTE 2 TOP RECESSED ALLEN HEAD CAP SCREW 518" - I I NC x 2" GRATE FRPME SECTION BOLT -DOWN DETAIL SEE NOTE 2 24 114" I SECTION A SEE DETAIL _ ISOMETRIC VIEW 1 ur, 1 NOTES: 4 1�" 1. THIS FRAME IS DESIGNED TO ACCOMMODATE 20" x 24" GRATES OR COVERS, SEE STANDARD PLANS 204.10, 204.20, 204.30, AND 204.40. I 1 518" I 2. BOLT -DOWN CAPABILITY I$ REQUIRED ON ALL FRAMES, GRATES, AND ` I COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. 314" / THE BEING APPED,4LL ACCEPT OR CREW BY OTH R THEAPPROVED M CHAR SM. LOCATION F BOLT-DOWN HOLES VARIES BY MANUFACTURER. \ \ 21/2 / 3. REFER TO STANDARD SPECIFICATION 91 FOR ADDITIONAL \ DETAIL REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTD SCALE (NTS) STD. PLAN - 204.00 DEPARTMENT a PUBLIC WORKS RECTANGULAR FRAME D 9/28/2018 1 GAZ a DATE RECTANGULAR FRAME :45 AI :45 m PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 18" CONCRETE ALL METAL PIPE 21" CPSSP', 18" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 21 PROFILE WALL PVC, STD. SPEC. 9-05.12(2I 21" " CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE .4', 6", 12', OR 24" SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE JR 6" HEIGHT RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF INCREMENT (SPACED EQUALLY), 0.12 SQUARE INCHES PER FOOT MAY BE USED. SEE NOTE 1 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 26". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM RECTANGULAR ADJUSTMENT SECTION GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE 15 INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE V. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NOWSHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. - 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. HP 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. „ n. •�c 6� / \SEER �8" 93 BAR HOOP REDUCING SECTION #3 BAR EACH CORNER 18" MIN. #3 BAR EACH CORNER #3 BAR EACH SIDI 43 5-11 PRECAST BASE SECTION • PUBLIC WORKS DR) BASIN TYPE 1L "` DEPARTMENT GAZ 9/28/2018 1 wark,A DATE CATCH BASIN TYPE 1L C6.3 NTS DocuSign Envelope ID: 6EEC F586-602A-4E4A-B436-A317AA638878 24" O 21.' DIA. HOLE i 201, A Q �CipQpQ -cz:-��d �pQpQpQ-<C­ Q�Q� QpQp TOP m ISOMETRIC SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 200.10 PPR D: I 1!2" BOLT -DOWN SLOT, glq I SEE DETAIL AND NOTE 1 "1 114' I S,B•' I I I I I BOLT -DOWN SLOT DETAIL SEE NOTE 1 3' R26", SEE NOTE 2 1 1/2' 4 314" 1 1!2" SECTION B 1 5,W MAX. R39". SEE NOTE 2 5„ NOTES: J 12" -- r 14" 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. 1 5/8" PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THIEF RAME SHALL ACCEPT THE 5/8'-11 NC x 2' ALLEN 4" HEAD CAP SCREW BY BEING TAPPED, OR OTHER II` DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 112' DIA. HANDLE 1 V2" 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. SECTION C 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING 15 NOT70 SCALE (NTS) STD. PLAN - 204.10 PUBLIC WORKS ,� RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 I ^I� DEPARTMENT v"rk,aem„nrrm. DATE RECTANGULAR SOLID METAIL COVER NTS C6.3 NTS cPm*ote r r a ENGINEERING PLLC 321 3rd Ave South, Suite 406 Seattle, Washington 98104 Lij ph 206.596.7115 Ud coterraeng I neen ng.com U- I� REVISION :45 AI :45 AN CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28' MAX. 16" MAX. FLAT SLAB TOP 96% 120" OR 144" SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER L- 12" (TYP.) �o I- 1"MIN. "O' RING 24' 2.5' MAX. REINFORCING STEEL, (TYP.) 12" MIN. 12" MAX. GRAVEL BACKFILL FOR PIPE ZONE 12"' BEDDING PER WSDOT STD, SPECIFICATION SECTION 9-03.12(3) 6' 6" SEPARATE BASE INTEGRAL BASE PRECAST PRECASTWITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5' MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE. USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. PUBLIC WORKS '41� DEPARTMENT CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS *.. 4' IF, 36. 8., 1.. 4.5" 8" 42• 8" W, 51 8" 48" 8" 72" 6" 8" 80' 12" M, 81 12" 72' 12" 96" 81 1Y" 84' 12" 120" 10• 1z, 96' 12" 144' 12' 12" 108" 17 PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP SOLID WALL PVC � PROFILE WALL PVC, 48' 24" 30" 24" 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42' 36" 42" 42" 72" 42' 54' 42" 4B" 49" 84" 54' 60" 54" 45" 48" 96' 60' 72" 1 60" 1 48" 1 48" 120" 66' 1 84" 60" 48" 48" 144' 78' 1 96" 60" 48" 48" CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 'SM. SPEC. 9-05.12(1) 'SM. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 CATCH BASIN TYPE 2 HERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 201.00 R GAZ 9/28/2018 I warksAem DATE :45 AI CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION I I I I I I I I SEE NOTE 4 F7�Z NOTES: 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS 15 PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND ORY2 BOND. 5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. 6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOTIAPWA STANDARD SPECIFICATION 9-04.3. 7. PICK ! LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) PUBLIC WORKS STD. PLAN - 202.00 • PRo ` 2, DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 1 9 wark,an DATE CATCH BASIN INSTALLATION C6,3 NTS C6.3 NTS DocuSign Envelope ID: 6EEC F586-602A-4E4A-B436-A317AA638878 n i rc i LL FLOW 8 o OUTFACE TO STREAM DUMP NO POLLUTANTS � I 1 I I I I BOLT -DOWN SLOT, 1 112" SEEDETAILAND NOTE 1 3/4' 1 1I14- A I 5re I I TI I I I I I I BOLT -DOWN SLOT DETAIL SEE NOTE 1 TOP (m) 3ED LETTERING ISOMETRIC SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 518•-11 NO x 2' ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING 15 NOT70 SCALE (NTS) STD. PLAN - 204.20 •�• PUBLIC WORKS `�„ DEPARTMENT RECTANGULAR VANED GRATE PRO GAZ 9/28/2018 1 v"rk,aem" r". DATE RECTANGULAR VANED GRATE NTS SURVEYED: DESIGNED: HS DRAWN: HS CHECKED: PA BY DATE APPR APPROVED: SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL, NAD 1983/1991 DATUM :45 AN CONSTRUCTOR RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS BASED UPON UTILITY AS -BUILT SURVEY PREPARED BY D.R. STRONG CONSULTING ENGINEERS INC., DATED 12/10/21, AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ENGINEER. +_ CITY OF RENTON Planning/Building/Public Works Dept. :45 A R-412718 , Li N O O 1 O) T D J H z IN COMPLIANCE WITH CITY OF RENTON STANDARDS w SUNSET OAKS APARTMENTS SUNSET LANE NE, RENTON, WA CITY OF RENTON CML DETAILS rr a 0- Q U) Q DATE: 10/5/20 O � I FIELDBOOK: ' PAGE: V i DRAWING NO: C6.3 Z SHEET. OF, 18 36 U)