Loading...
HomeMy WebLinkAboutMFP22002140DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Comcast Cable Communications Management jessamin_santos@cable.comcast.com (206) 401-2188 Jessamin Santos Cannon Construction LLC - 253-922-2787 20838601590363 JB0000935334 F61271-JB-935334-RENTON-1 REV1620 S 7TH ST, RENTON WA 98057 The proposed work within the ROW is to BURY NEW 347 of (1) 2" CONDUIT AND PULL NEW .875 SERIES COAX TO 620 S 7TH ST; PLACE NEW (2) 17"x30" VAULT IN LANDSCAPE. x x x 347' 1/4/23 Kip Braaten CED 2-3-2023 Restorations Per C.O.R. Standards Pothole all Existing Utilities Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering 425.941.7820 Milton,WA 98354406 Porter Way Nate Pinson x x Project Name: F61271-JB-935334-RENTON-1 Permit #: Site Address: 620 S 7TH ST, RENTON WA 98057 Work Date: From 2/6/2023 TO 2/17/2023 Work Time: Start ____9AM__________ End ____3PM__________ Construction Company: Cannon Construction LLC The proposed work within the ROW is to BURY NEW 347' of (1) 2" CONDUIT AND PULL NEW .875 SERIES COAX TO 620 S 7TH ST; PLACE NEW (2) 17"x30" VAULT IN LANDSCAPE. REV1 MFP22002140 Kip Braaten 2-3-2023CED Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) 4/22/22 Sandra Castro DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION SHEET INDEX: C1 - 0VERVIEW MAP C2 - LEGEND TCPG - TCP SPECS & GENERAL NOTES PS - PROJECT SHEET 1 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437CHRIS.ATKINSON@CABLECOMLLC.NET C1 PROJECT DESCRIPTION: . BEGIN ROW WORK: 47.47388, -122.20961 END ROW WORK: 47.47382, -122.20835 MFP22002140 LINETYPES RISER POLE POLE ANCHOR/DOWN GUY STREET LIGHT MISC. UTILITY UTILITY POLE GROUND/BOND FIRE HYDRANT CULVERT WING WALL BRIDGE MANHOLE PULL-BOX VAULT/BUILDING STORAGE COIL AERIAL STORAGE A A AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED STRAND - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED B B B B B B B B UNK UNK UNKNOWN UTILITY EOP EOP EOP RIGHT OF WAY EDGE OF PAVEMENT U R 0' 0' STREET SIGN - NO POWER STREET SIGN - w/ POWER TRAFFIC LIGHT PERMANENT SIGNS CONCRETE BOLLARD GATE ARMS ROAD YELLOW LINES ROAD WHITE LINES PARKING LINES RAILROAD SIDEWALK SIDEWALK HATCH - CONCRETE SIDEWALK HATCH - ASPHALT OVERHEAD CABLE GUARDRAIL P/L P/L PROPERTY LINE EASEMENT HANDICAP PARKING - PAINT R/W R/W A A A A SYMBOLS TRENCH INSTALLATION VAULT/PROPOSED VAULTVV DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems C2 MFP22002140 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH 50/70 35/45 25/30 TAPER TANGENT 40 30 20 80 60 40 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' WORKZONE TRAFFIC CONTROL GENERAL INFO PCMS TM A SEQUENTIAL ARROW SIGN TRANSPORTABLE ATTENUATOR PORTABLE CHANGEABLE MESSAGE SIGN VERY SHORT DURRATION INTERSECTION CROSSING PRPOTECTIVE VEHICLE VERY SHORT DURRATION INTERSECTION CROSSING FLAGGING STATION LEGEND FLAGGING STATION TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE SPOTTER STATION GENERAL NOTES: 1. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-950302. 2. PRIORITY PASSAGE THROUGH WORK AREA FOR EMERGENCY VEHICLES SHALL BE PROVIDED AT ALL TIMES. 3. ALL SIGNS, CHANNELIZED DEVICES AND SPACING SHALL CONFORM TO THE MUTCD. 4. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES (SEE TABLE FOR SPACING DISTANCES) 5. ALL SPACING MUST ACCOMMODATE AT-GRADE INTERSECTION AND/OR DRIVEWAYS. 6. MAINTAIN 4' MINIMUM SIDEWALK WIDTHS. 7. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTHS. 8. SPACING MAY BE REDUCED IN URBAN AREA TO FIT CONDITIONS. 9. SPOTTER TO ASSISTS PEDESTRIANS AROUND WORK ZONE. 10. SPACING MAY BE REDUCED IN URBAN AREA TO FIT CONDITIONS. 11. UNIFORMED POLICE OFFICER REQUIRED ON SITE WHEN WORKING WITHIN 150' OF A SIGNALIZED INTERSECTION. NEW TRAFFIC FLOW UNIFORM POLICE OFFICER TCPG > MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST (DEAD END) T A L BO T R D S ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A CLOSED RIGHT LANE W20-5R AHEAD W4-2r X X X X X X X X X X X X X SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT25CONTRACTOR TO POST NOPARKING SIGNS 72HRS IN ADVANCEWITH DATE / TIME POSTED WORK AREA WORK AREA 34'34' 28'17'76' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH50/70 35/4525/30 TAPER TANGENT40 3020 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAY 16'SPOTTER TO ASSIST PEDESTRIANS THROUGH WORK ZONE TCP PHASE 1 X ROADWORK W21-4 AHEAD ONE LANE ROAD W20-5L AHEAD X X PS-1 MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST (DEAD END) T A L BO T R D S ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A CLOSED RIGHT LANE W20-5R AHEAD W4-2r X X X X X X X X X X X X X SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT25WORK AREA WORK AREA34'34' 28'17'76' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH50/70 35/4525/30 TAPER TANGENT40 3020 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAY SPOTTER TO ASSISTPEDESTRIANS THROUGH WORK ZONE TCP PHASE 2 X ROADWORK W21-4 AHEAD ONE LANE ROAD W20-5L AHEAD X X PS-1 MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST (DEAD END) T A L BO T R D S ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A CLOSED RIGHT LANE W20-5R AHEAD W4-2r X X X X X X X X X X X X X SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT25WORK AREAWORK AREA34'34' 28'17'76' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH50/70 35/4525/30 TAPER TANGENT40 3020 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAY SPOTTER TO ASSISTPEDESTRIANS THROUGHWORK ZONE TCP PHASE 3 ROADWORK W21-4 AHEAD ONE LANE ROAD W20-5L AHEAD X X WORK AREA WORK AREA 48" 48" W20-7A X SIDEWALK CLOSEDR9-9 12" 24" SIDEWALK CLOSED R9-9 12" 24" PS-1 MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST (D E A D E N D ) T A L BO T R D S ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A CLOSED RIGHT LANE W20-5R AHEAD W4-2r X X X X X X X X X X X X X SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT2534'34' 28'76' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH50/70 35/4525/30 TAPER TANGENT40 3020 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAY TCP PHASE 4 WORK AREA SIDEWALK CLOSEDR9-9 12" 24" SIDEWALK CLOSED R9-9 12" 24" CLOSE BUSINESS DRIVE; NOTIFY OWNER5 DAYS IN ADVANCE WORK AREA FLAGGER TO ASSIST LOCAL TRAFFIC TO 620S 7TH ST (NO ALTACCESS) SIDEWALK CLOSEDR9-9 12" 24" PS-1 MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC 1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST (D E A D E N D ) T A L BO T R D S ROADWORK W21-4 AHEAD ONE LANE ROAD W20-5L AHEAD ROADWORK W21-4 AHEAD ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A ROADWORK W21-4 AHEAD ONE LANEROAD W20-5L AHEAD 48" 48" W20-7A X X X SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT2534'34' 28'76' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH50/70 35/4525/30 TAPER TANGENT40 3020 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAY TCP PHASE 5 CLOSE BUSINESS DRIVE; NOTIFY OWNER5 DAYS IN ADVANCE WORK AREA FLAGGER TO ASSIST LOCAL TRAFFIC TO 620S 7TH ST (NO ALTACCESS) SIDEWALK CLOSEDR9-9 12" 24" 11' X X X X X PS-1 MFP22002140 Pothole all Utilities Restoration per C.O.R. Standards DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION SHEET INDEX: C1 - OVERVIEW MAP C2 - LEGEND C3 - GENERAL NOTES PS - PROJECT SHEET 1 TYP - TYPICALS 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E C1 PROJECT DESCRIPTION: The proposed work within the ROW is to BURY NEW 347' of (1) 2" CONDUIT AND PULL NEW .875 SERIES COAX TO 620 S 7TH ST; PLACE (2) NEW 17"x30" VAULT IN LANDSCAPE. BEGIN ROW WORK: 47.47388, -122.20961 END ROW WORK: 47.47384, -122.20849 MFP22002140 LINETYPES RISER POLE POLE ANCHOR/DOWN GUY STREET LIGHT MISC. UTILITY UTILITY POLE GROUND/BOND FIRE HYDRANT CULVERT WING WALL BRIDGE MANHOLE PULL-BOX VAULT/BUILDING STORAGE COIL AERIAL STORAGE A A AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED STRAND - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED B B B B B B B B UNK UNK UNKNOWN UTILITY EOP EOP EOP RIGHT OF WAY EDGE OF PAVEMENT U R 0' 0' STREET SIGN - NO POWER STREET SIGN - w/ POWER TRAFFIC LIGHT PERMANENT SIGNS CONCRETE BOLLARD GATE ARMS ROAD YELLOW LINES ROAD WHITE LINES PARKING LINES RAILROAD SIDEWALK SIDEWALK HATCH - CONCRETE SIDEWALK HATCH - ASPHALT OVERHEAD CABLE GUARDRAIL P/L P/L PROPERTY LINE EASEMENT HANDICAP PARKING - PAINT R/W R/W A A A A SYMBOLS TRENCH INSTALLATION G G W W T T E E SEW SEW SD SD X X X TV TV GAS WATER TELEPHONE ELECTRIC SANITARY SEWER (SEW) STORM DRAIN FENCE CABLE TV VAULT/PROPOSED VAULTVV 3'x5' BORE PIT 8" POTHOLE DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems C2 MFP22002140 EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO P EO P EOP EO P EOPEOPEOPEOPEOPEO P EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSMITHERS AVE SParcel 2963900055633 SMITHERS AVE S BURNETT AVE SS 7TH ST S 7TH ST T A L BO T R D S SPEE D LIMIT25 SPEEDLIMIT25 SPEEDLIMIT2534'34' 28'17'76' Parcel 1923059025423 S 7TH ST Parcel 1823059061633 BURNETT AVE S Parcel 1823059046620 S 7TH ST Parcel 9154600005800 S GRADY WAYSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSDSDSDSDSDSDSDSDSDSDWWWWWWWWWWWWWWWWWWW WWWWWWWWW WWW W WW W W W W W W WWWWWSEWSEWSEWSEWSEWSEW SE W SE W SE W SE W SEWSEWSEWSEWSE W SE W SE W SE W SE W SEWSEWR/ W R/ W R/ W R/ W R/ WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ WR/WR/WR/WR/WR/WR/WR/W R/W R/ W R/ W R/ W R/ W R/ WR/WR/WR/WR/WR/WR/W R/W R/ W R/ W R/ W R/ W R/ W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/ W R/ W R/ W R/ W R/WR 5' PLACE (1) 30"17"VAULT IN LANDSCAPE; END ROW WORK47.47384, -122.20849 BEGIN ROW WORK:47.47388, -122.20961TIE INTO EXISTING ARIALPLANT: PLACE NEW 2"RISER, PULL NEW .875COAX V Bore Pit; PLACE (1) 30"x17" VAULT INLANDSCAPE VB BB B B B B B B BB B B B B6' TRENCH BURY 42' of (1)2" CONDUIT MIN 36"DEEP ; PULL (1) .875SERIES COAX TRENCH BURY 25' of (1) 2" CONDUIT MIN 36"DEEP ; PULL (1) .875 SERIES COAXDIRECTIONAL DRILL 128'of (1) 2" CONDUIT MIN36" DEEP ; PULL (1) .875 SERIES COAX DIRECTIONAL DRILL 152'of (1) 2" CONDUIT MIN36" DEEP ; PULL (1) .875SERIES COAX W W 5' ESTIMATED GRINDAND OVERLAY ESTIMATED GRINDAND OVERLAY9'DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/20221" = 50' PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E 1.UTILIES SHOWN ARE APPROXIMATE. CONTRACTOR TOHAVE ALL UTILITIES VERFIED PRIORTO CONSTRUCTION START 2.EXISTING DRAINAGE SYSTEM(GRATE INLET, DITCH, ETC.) SHALLBE PROTECTED AND FUNCTIONAL THROUGHOUT THECONSTRUCTION PROJECT. IF ANYPARTS OF THE SYSTEM AREIMPACTED BY CONSTRUCTIONACTIVITIES, THEY SHALL BERESTORED TO THE ORIGINALCONDITIONS. 3.POTHOLE IS SOFT SURFACES WHEN AVAILABLE. PATCH POTHOLELOCATION PER LOCALJURISDICTION SPECIFICATION 4.PROPOSED PATH MAY CHANGEAT TIME OF CONSTRUCTION DUETO UTILITY LOCATIONS ANDINSPECTOR REQUIREMENTS 5.UNKNOWN UTILITY DEPTHS TO BEVERIFIED IN FIELD DURING TIME OFCONSTRUCTION PS-1 MFP22002140 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems STANDARD DETAILS BORE AT PAVEMENT BORE PIT DETAIL POTHOLE REPAIR POTHOLE REPAIR TYP MFP22002140 Restorations Per C.O.R. Standards Pothole all Existing Utilities DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 935334 MSJD04/20/2022 PROJECT FOR: RENTON, WA 98057 620 S 7TH ST Watershed Apts Plus 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems RENTON TYPMFP22002140