Loading...
HomeMy WebLinkAboutAs-Builts.pdfGRAPHIC SCALE (IN FEET) 030 30 60 120 ELECTRICAL PERMITTING MANAGEMENT CONSTRUCTION NO: SHEET TITLE: MANAGEMENT PROJECT 355 110TH AVE NE, BELLEVUE WA. 98004 NAMEGROUP CIVIL NO: DRAWINGPSE ENGINEERING CONTACTS PHONE EMAIL 425-495-6239 425-396-3776 425-462-3954 DRAWING LIST: LEGEND SUBSTATION FENCE CATCH BASIN PROPERTY LINE GATE VALVE GRAVEL DRIVEWAY VICINITY MAP NO SCALE Know what'sbelow. before you dig.Call R SITE INFORMATION: ZONING: ADDRESS: PARCEL NO: PROPERTY OWNER: LEGAL DESCRIPTION: SUBSTATION SHUFFLETON EXISTING FOUNDATION NICHOLE PORTER ZERECK JONES zereck.jones@pse.com nichole.porter@pse.com SECTIONS 5 & 8, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR 22 25 GC (GENERAL COMMERCIAL) RENTON, WA 98056 1095 LAKE WASHINGTON BOULEVARD NORTH 0823059178 PUGET SOUND ENERGY AND THE POINT OF BEGINNING. LINE A DISTANCE OF 369.00 FEET TO SAID NORTHERLY MOST CORNER SAID LOT; THENCE NORTH 46°43'23" EAST ALONG SAID NORTHWESTERLY WEST A DISTANCE OF 278.00 FEET TO THE NORTHWESTERLY LINE OF SAID LOT A DISTANCE OF 369.00 FEET; THENCE NORTH 43°47'07" THENCE SOUTH 46°43'23" WEST ALONG THE SOUTHEASTERLY LINE OF LOT AND ITS SOUTHEASTERLY EXTENSION A DISTANCE OF 278.00 FEET; SOUTH 43°47'07" EAST ALONG THE NORTHEASTERLY LINE OF SAID COMMENCING AT THE NORTHERLY MOST CORNER OF SAID LOT; THENCE RECORDS OF KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: LUA-98-176-LLA AS FILED UNDER RECORDING NUMBER 9902019014, THAT PORTION OF LOT "A", CITY OF RENTON LOT LINE REVISION CODY SPENCE 425-466-8946 cody.spence@pse.com KERRY KRINER 425-462-3821 kerry.kriner@pse.comNRYAN WIEDER ryan.wieder@pse.com PROPOSED RETAINING WALL EXISTING RETAINING WALL N 46°43'23" E 369.00' S 46°43'23" W 369.00'S 43°47'07" E 278.00'STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481 EASEMENT LINE 50'-0"ACCESS EASEMENT5'-0"4'-0" RETAININGWALL EASEMENT (TYP)PERMIT #C21000323 CITY OF RENTON, KING COUNTY, WASHINGTON PURPOSE GRANTEE EASEMENT FOR EXCLUSIVE #8407260401 MAIN EASEMENT 15'-0" FIRE #8407260401 MAIN EASMENT 15'-0" FIRE #20010629002927 UTILITY EASMENT 2 1 OF 2 SITE SHUFFLETON SUBSTATION AND GENERAL NOTES SITE PLAN D-20891 SHU 1"=30'-0" 141005363 CITY OF RENTON R-417001TED-404170N 43°47'07" W 278.00'CHAIN LINK FENCING SECTIONS AND DETAILS IRRIGATION NOTES AND DETAILS IRRIGATION PLAN LANDSCAPE NOTES LANDSCAPE DETAILS LANDSCAPE PLAN STRUCTURAL PLAN FOUNDATION PLAN DRAINAGE DETAILS DRAINAGE PLAN GRADING AND FENCING SECTIONS AND DETAILS GRADING AND FENCING PLAN DEMOLITION PLAN TEMPORARY EROSION/SEDIMENT CONTROL DETAILS TEMPORARY EROSION/SEDIMENT CONTROL PLAN SITE PLAN AND GENERAL NOTES SITE PLAN AND GENERAL NOTES 1 2 1 3 2 1 1 1 2 1 2 1 1 2 1 2 1 D-18381 D-20899 D-20898 D-20897 D-10163 D-20895 D-20894 D-20893 D-20892 D-20891 SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:1/12/20234:36:55 PMD-20891_01.dgnUSER: jinelsAS-BUILT c:\pwworking\projectwise\jinels\dms14623\D-20891_01.dgn INTERNAL USE Know what'sbelow. before you dig.Call R 17. 16. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. NOTES: LESS THAN 2 INCH ROCK/10-20% PASSING 2-4 INCH ROCK/30-40% PASSING; AND 4-8 INCH ROCK/40-70% PASSING; THE CITY LOGO. OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE OF THE ROADWAY. RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE BOTTOM OF THE DITCH. LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 204.30, 204.40 AND 204.50. STRUCTURES SHALL HAVE: DUCTILE IRON, BOLT-LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH INSIDE AND OUTSIDE. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2 OR 5 220.00, 220.10, AND 220.20. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORM DENSE, UNYIELDING BASE. COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION BY THE CITY. OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, TO THE GRADE AS STAKED. THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO STANDARDS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT TESTS OF THE WSDOT STANDARD SPECIFICATIONS, IN PERMEABLE PAVEMENT AND OTHER MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D-COMPACTION AND MOISTURE CONTROL ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 ENGINEER OF RECORD IF A CONFLICT EXISTS. CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ON THE AS-BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HERON HAVE BEEN ESTABLISHED CONSTRUCTION IS IN PROGRESS. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER FROM THE CITY. APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL BE CONTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY SEWER, GAS, ELECTRICAL, ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FROUND IN THE IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), THE STANDARDS SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, CONTRACTOR. HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB OF THE RENTON SWDM. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.1.2.A2 SHALL BE MAINTAINED BY THE APPLICANT. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS PER ADA REQUIREMENTS. SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON-SLIP OR NON-SKID LID AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, REGULATIONS (RMC 4-3-050). WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION PROJECTS LOCATED WITH THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY PUBLIC AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND DURING CONSTRUCTION. FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF TESTED. SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN PROJECT CURBS, GUTTERS AND/OR PAVEMENT. SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL ACCORDING TO THE CITY STANDARD PLAN 266.00. CCVT INSPECTIONS AND REPORTS CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ALL NEWLY-INSTALLED AND NEWLY-REHABILITATED (PUBLIC AND PRIVATE) STORM PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE A BOLT-LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH ON-SITE BMPS. APPROVED BY THE CITY, FOOTING DRAINS SHALL NOT BE CONNECTED TO CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE MEET THE FOLLOWING SPECIFICATIONS: OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE 31. 30. 29. 28. 27. 26. 25. 24. 23. 22. 21. 20. 19. 18. SURFACE WATER PLAN NOTES:STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481 CITY OF RENTON R-417002 2 2 OF 2 SITE SHUFFLETON SUBSTATION AND GENERAL NOTES SITE PLAN D-20891 SHU NONE 141005363 TED-404170SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:12/28/20222:39:43 PMD-20891_02.dgnUSER: jinelsAS-BUILT c:\pwworking\projectwise\jinels\dms14623\D-20891_02.dgn INTERNAL USE LEGEND SUBSTATION FENCE PROPERTY LINE GRAVEL DRIVEWAYNPROPOSED CONTOURS EXISTING MAJOR CONTOURS EXISTING MINOR CONTOURS21 21 25 SEE D-18381 GATE (TYP 2 PLACES), 20' WIDE STATIONR=25' R=25'R=30'R=1 0 'R=45' R=25' R=25' SEE SHEET 2, DETAIL 1 (TYP AROUND SUBSTATION). 5'-0" GRAVEL SHOULDER SPOT ELEVATION23.03 LANDSCAPE BUFFER REFERENCE DRAWINGS D-18381 D-20897 D-20896 D-20895 D-20892 D-20891 CHAIN LINK FENCING SECTIONS AND DETAILS STRUCTURAL PLAN FOUNDATION PLAN DRAINAGE PLAN TEMPORARY EROSION/SEDIMENT CONTROL PLAN SITE PLAN 16'-0" 20'-0" 5'-0" 20'-0" 20'-0" 2 D 2 C 2 B 2 A (TYP), SEE D-18381 LINK STATION FENCE NEW 7' HIGH CHAIN THIS DRAWING SUPERSEDES D-5423_01 SEE SHEET 2, DETAIL 2 CATCH BASIN (TYP), 4'-0" 10'-0"25 EQUAL SECTIONS @ 9'-10" = 246'-0"= 24'-11"@ 8'-3•"SECTIONS3 EQUAL20'-0"EXISTING RETAINING WALL PROPOSED RETAINING WALL R=43' EXISTING FOUNDATION (REF ONLY) CATCH BASIN (REF ONLY) GATE VALVE (REF ONLY) SANITARY SEWER MANHOLE (REF ONLY) PROPOSED STORM DRAINAGE PIPE (REF ONLY) EXISTING STORM DRAINAGE PIPE (REF ONLY)STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481 GRAPHIC SCALE (IN FEET) 020 20 40 80 35 EQUAL SECTIONS @ 9'-9•" = 343'-0" FOR INTERIM TO REMAIN BUILDING EXISTING FOR INTERIM TO REMAIN BUILDING EXISTING EASEMENT LINE ACCESS ROAD EASEMENT50'-0"SCREENING LANDSCAPE 6'-0" SCREENING LANDSCAPE 15'-0" SCREENING LANDSCAPE 6'-0" WALL EASEMENT 4'-0" RETAINING WALL EASEMENT 4'-0" RETAINING GRADING NOTE:SIDE OF BUILDINGGRAVEL PATH AT SOUTH2 1 OF 2 SITE SHUFFLETON SUBSTATION FENCING PLAN GRADING AND D-20894 SHU 1"=20'-0" 141005363 CITY OF RENTON R-417006 Know what'sbelow. before you dig.Call R @ 9'-9•" = 284'-0" 29 EQUAL SECTIONS 15,151.07 SF PURPOSE GRANTEE FOR EASEMENT EXCLUSE 5'-0" #8407260401 MAIN EASEMENT 15'-0" FIRE #8407260401 MAIN EASMENT 15'-0" FIRE #20010629002927 UTILITY EASMENTTED-404170G W SS E FO WATER LINE (REF ONLY) GAS LINE (REF ONLY) SANITARY SEWER (REF ONLY) POWER LINE (REF ONLY) FIBER OPTIC LINE (REF ONLY) T TELEPHONE LINE (REF ONLY) BUILDING VACANT EXISTING BLDG COMM EXST EACH LAYER UNIFORMLY TO THE REQUIRED DENSITY. 8" THICK, LOOSE MEASUREMENT. SPREAD AND COMPACT PLACE LOAD BEARING BACKFILL IN LAYERS NOT MORE THAN PRIOR TO BACKFILLING. REMOVE ALL DEBRIS FROM THE AREA TO BE BACKFILLED ACCORDANCE WITH ASTM D4254 FOR COHESIONLESS SOILS. COHESIVE SOILS, OR 75% OF RELATIVE DENSITY IN MAXIMUM DENSITY IN ACCORDANCE WITH ASTM D1557 FOR ALL FILL OR BACKFILL SHALL BE COMPACTED TO 95% OF PER DETAIL 1 ON SHEET 2). GRADE AND ADD 9" BASE COURSE AND YARD ROCK (AS REMOVE EXISTING ASPHALT, GRADE TO SUB-BASE FINAL FOR AREAS REQUIRING FILL OR CUT IN EXCESS OF 9": GRADE AND ADD YARD ROCK PER PSE STANDARD DETAIL. REMOVE EXISTING ASPHALT, GRADE TO BASE COURSE FINAL DETAIL 1 ON SHEET 2): EXCESS OF THE REQUIRED 9" OF BASE MATERIAL (AS PER FOR AREAS OF THE SITE THAT DO NOT REQUIRE CUT IN 4. 3. 2. 1.NORTH-SOUTH BASELINEN 43°47'07" EEAST-WEST BASELINE S 46°43'23" W 5'-0"20'-0"22.28 22.47 22.34 22.43 22.74 22.55 22.60 22.74 23.01 23.31 23.50 23.64 22.26 22.0922.08 22.3022.3622.52 22.7322.9923.17 22.31 23.25 23.24 23.48 23.19 23.40 23.16 23.29 23.36 23.36 23.29 23.36 23.38 23.27 23.27 23.18 ECO BLOCKS EXISTING WALL USING RETAINING 35' X 2' 23.81 23.25 23.90 23.78 ON FENCE LINE TOE OF SLOPE TOP OF SLOPE 22.09 22.14 22.1922.21 22.90 22.26 22.7922.33 22.55 22.38 22.06 22.01 22.95 21.75 21.57 SCREENING FOR LANDSACPE 23.26 23.37 23.27 23.24 23.00 22.70 22.28 22.08 22.00 24.1524.16 23.92 23.91 24.21 23.80 23.86 23.74 23.90 23.67 23.58 23.51 23.42 23.86 23.68 23.34 23.27 23.10 23.28 23.20 23.50 23.70 23.70 23.54 23.70 23.30 23.69 23.14 23.00 23.02 23.29 23.78 22.00 SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:1/13/20239:13:52 AMD-20894_01.dgnUSER: jinelsAS-BUILTGGG24 23 232422 23 T FO 22 23 23 23 23 2323 c:\pwworking\projectwise\jinels\dms14623\D-20894_01.dgn INTERNAL USE 2 2 OF 2 SITE Know what'sbelow. before you dig.Call R D-20894 SHU NONE 141005363 SHUFFLETON SUBSTATION DETAIL 2 1 THIS DRAWING SUPERSEDES D-5423_02 OUTLET PIPE INLET PIPE 6"MIN 2'-0" TAPER (TYP) 9" BASE COURSE OF FOUNDATIONS, ETC FROM 10' AWAY OR FROM EDGE SLOPE TOP OF BASE COURSE OUTSIDE OF SPCC AREA TYPICAL CATCH BASIN GRADING COURSE STATION FENCE SHOULDER 2 1 9"BASE COURSE 2% SLOPE NATIVE SOIL OR COMPACTED SUBBASE FILL TYPICAL STATION SECTION DETAIL 1 1 20'-0"5'-0" 1 SECTION D NTS STATION DRIVEWAY 16'-0" STATION DRIVEWAY STATION DRIVEWAY SECTION A 1NTS SECTION B 1NTS 5'-0" SHOULDER DRIVEWAY 5'-0"5'-0"4"13"STATION FENCE COURSE 4" YARD BASE COURSE > DRIVEWAY COURSE 4" TOP OR SUBBASE FILL NATIVE SOIL > DRIVEWAY TOP COURSE BASE COURSE 10'-0"10'-0"4"9"13"OR SUBBASE FILL NATIVE SOIL 20'-0" 1 SECTION NTS STATION DRIVEWAY C COURSE 4" TOP > DRIVEWAY STATION FENCE OR SUBBASE FILL NATIVE SOIL OR SUBBASE FILL NATIVE SOIL > DRIVEWAY COURSE 4" TOP STATION FENCE COURSE 4" YARD BASE COURSE13"SHOULDERDRIVEWAY 9"9"13"4"4"9"DRIVEWAY SHOULDER 5'-0" COURSE BASE SECTIONS AND DETAILS GRADING AND FENCING STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481 COURSE 4" YARD 4" YARD CAST FRAME INTO ADJUSTMENT SECTION OLYMPIC FDRY NO. SM 60 D/T OR EQUAL. GRATE (WA STATE STD PLAN B-30.50-03) (WA STATE STD PLAN B-30.10-03) & REVERSIBLE CAST IRON FRAME CITY OF RENTON R-417007TED-4041708'-6"5'-0" SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:1/11/202310:57:54 AMD-20894_02.dgnUSER: jinelsAS-BUILT c:\pwworking\projectwise\jinels\dms14623\D-20894_02.dgn INTERNAL USE LEGEND SUBSTATION FENCE PROPERTY LINE GRAVEL DRIVEWAY GRAPHIC SCALE (IN FEET) 020 20 40 80 CATCH BASIN SCHEDULE CB34 CB33 CB35 CB38 CB19 CB37 CB21 CB32 CB29 CB26NCB24 CB15 CB17 60 LF CB36 60 LF 60 LF 60 LF PVC ROOF DRAIN 4" SCH 40 PIPE 12" CONC PIPE 12" CONC 12" CONC PIPE ABANDONED50 LFREINF CONCPIPE12" CONCCB25 CONC PIPE 12 LF 8"31 LF 12"@ 0.5%CONC PIPE59 LF 8" CONCPIPE @ 0.5%31 LFDRAIN ROOF 8" PVC 26 LF 8" PVC 13 LF DETAIL 1 (TYP). SEE SHEET 2, TYPE 1 CATCH BASIN THIS DRAWING SUPERSEDES D-5424_01 CB52 6" SCH 80 PVC 6" SCH 80 PVC 6" SCH 80 PVC 6" SCH 80 PVC CB40 CB41 CB46 12" CONC67 LFPROPOSED CATCH BASIN TYPE 1 EXISTING CATCH BASIN TYPE 1 EXISTING GATE VALVE BUILDING VACANT EXISTING BLDG COMM EXST CB43 CB44 CB47 CB50 CB48 CB49 CB51 @ 1.58% 15 LF 8" PVC @ 0.5% 61 LF 8" PVC 49 LF 8" PVC@ 0.25%40 LF 8" PCV@ 0.2%80 LF 8" PVC@ 0.125%59 LF 8" PVC @ 0.5%64 LF 12" PVC @ 0,25%EXISTING RETAINING WALL PROPOSED RETAINING WALL EXISTING FOUNDATION (REF ONLY) SE IE 19.42 RIM EL 20.78 CLEANOUT NE IE 19.28 NW IE 19.28 SE IE 19.28 RIM EL 20.51 CLEANOUT NW IE 19.76 RIM EL 21.48 CLEANOUT NW- 8" IE 20.89 RIM EL 22.80 CB52- TYPE 1 W- 8" IE 19.49 RIM EL 22.70 CB51 - TYPE 1 NW- 8" IE 19.42 E- 8" IE 19.42 RIM EL 22.86 CB50 - TYPE 1 SW- 8" IE 19.53 RIM EL 22.70 CB49 - TYPE 1 NE- 8" IE 19.30 NW- 8" IE 19.30 SE- 8" IE 19.30 RIM EL 22.85 CB48 - TYPE 1 SW- 8" IE 19.50 RIM EL 22.34 CB47 - TYPE 1 SW- 8" IE 19.14 NE- 8" IE 19.14 NW- 8" IE 19.14 SE- 8" IE 19.14 RIM EL 22.63 CB46 - TYPE 1 N IE 19.74 SW IE 18.76 NE IE 18.76 SDMH 54" SW IE 20.37 RIM EL 21.84 CLEANOUT 250 LF 4" PERF PVC @ 0.25% PLAN, D-20893 PER DEMOLITION WITH CONCRETE AND PLUGGED PROPERTY LINE PIPE REMOVED TO REFERENCE DRAWINGS D-20897 D-20896 D-20894 D-20892 D-20891 STRUCTURAL PLAN FOUNDATION PLAN GRADING AND FENCING PLAN TEMPORARY EROSION/SEDIMENT CONTROL PLAN SITE PLAN STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481 SHEET 2, DETAIL 4 STRIP @ 0.25%. SEE IN CENTER OF PLANTER 4" PERF PVC UNDERDRAIN DETAIL 4 SEE SHEET 2, STRIP @ 0.25%. IN PLANTER UNDERDRAIN 4" PERF PVC * SEE DETAIL 2 ON SHEET 2 E- 21.09 RIM EL 22.58 CB36 - TYPE 1 (EXIST) E- 20.79 W- 20.79 RIM EL 22.58 CB35 - TYPE 1 (EXIST) E- IE 21.51 RIM EL 22.58 CB34 - TYPE 1 (EXIST) E- IE 21.21 W- IE 21.21 RIM EL 22.58 CB33 - TYPE 1 (EXIST) SW- IE 20.53 SE- IE 20.48 RIM EL 22.88 CB32 - TYPE 1a DESIGN D* (EXIST) NW- 12" IE 20.12 S- 12" EXISTING PIPE ELEVATION RIM EL 3" BELOW SURROUNDING GRADE CB29 - TYPE 1a DESIGN D* (EXIST) SW- 8" IE 19.37 E- 12" IE 19.42 NE- 8" IE 19.82 RIM EL 21.07 CB26 - TYPE 1 (EXIST) SE- 8" IE 20.35 NE- 8" IE 20.25 NW- 12" IE 20.15 RIM 21.90 CB25 - TYPE 1 (EXIST) SE- 12" IE 20.03 SW- 8" IE 20.06 RIM EL 21.83 CB24 - TYPE 1 (EXIST) SW- IE 20.95 E- IE 21.69 NW- IE 20.89 RIM EL 22.79 CB21 - TYPE 1a DESIGN D* (EXIST) N- 12" IE 20.34 S- 12"IE 20.34 RIM EL 22.68 CB19 - TYPE 1a DESIGN D* (EXIST) SE- 8" IE 20.79 NW- 8" IE 20.74 RIM EL 22.09 CB17 - TYPE 1A DESIGN D* (EXIST) SW- 6" IE 20.00 NE- 8" IE 20.55 SE- 8" IE 20.55 RIM EL 21.80 CB15 - TYPE 1a DESIGN D* (EXIST) FOR INTERIM TO REMAIN BUILDING EXISTING FOR INTERIM TO REMAIN BUILDING EXISTING WAS REMOVED WHERE VALVE INSTALL PIPE PVC @ 0.25%56 LF 4" PERF@ 0.5% 8" PVC 29 LF 193 LF 4" PERF PVC @ 0.25%ACCESS ROAD EASEMENTWALL ESMT RETAINING 4'-0" WALL EASEMENT 4'-0" RETAINING 50'-0"@ 0.5% 169 LF 15" SD IE 18.59 SE 8" PVC IE 18.69 SW 15" CPEP RIM 22.00 CB W/SOLID LID 2 SITE SHUFFLETON SUBSTATION PLAN DRAINAGE D-20895 01 OF 02 SHU 1"=20'-0" 141005363 #8407260401 MAIN EASEMENT 15'-0" FIRE #8407260401 MAIN EASMENT 15'-0" FIRE #20010629002927 UTILITY EASMENT GRANTEE PURPOSE EASEMENT FOR 5'-0" EXCLUSIVE CITY OF RENTON R-417008 Know what'sbelow. before you dig.Call RTED-404170G W SS E FO T WATER LINE (REF ONLY) GAS LINE (REF ONLY) SANITARY SEWER (REF ONLY) POWER LINE (REF ONLY) FIBER OPTIC LINE (REF ONLY) TELEPHONE LINE (REF ONLY) MANHOLE (REF ONLY) SANITARY SEWER @ 0.5%STORM DRAINAGE PIPE VALVE EXISTING GRATE INLET w/OIL STOP SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:1/13/20232:51:38 PMD-20895_01.dgnUSER: jinelsAS-BUILT 146 LF 8" PVC @ 0.4%110 LF 8" PVC @ 0.2%@ 0.3%29 LFSE- 8" IE 18.86 W- 8" IE 18.71 NE- 8" IE 18.76 SW- 8" IE 18.86 RIM EL 21.85 CB44 - TYPE 1 (EXIST) SW- 8" IE 18.80 NE- 8" IE 18.82 SE- 4" IE 19.63 RIM EL 21.80 CB43 - TYPE 1 (EXIST) NW- 6" IE 21.04 RIM EL 22.69 CB41 - TYPE 1 (EXIST) NW- 8" 20.97 SE- 6" IE 20.97 RIM EL 22.68 CB40 - TYPE 1 (EXIST) NE- IE 20.47 S- IE 20.47 W- IE 20.47 RIM EL 22.68 CB38 - TYPE 1 (EXIST) N- IE 20.47 E- IE 20.47 RIM EL 22.68 CB37 - TYPE 1a DESIGN D* (EXIST)8" PVC21 LFc:\pwworking\projectwise\jinels\dms14623\D-20895_01.dgn INTERNAL USE 2 2 OF 2 SITE D-20895 SHU NONE 141005363 SHUFFLETON SUBSTATION DRAINAGE DETAILS 22"x 26" 6"MIN 1'-6"(MIN)TYPICAL CATCH BASIN, TYPE 1 DETAIL 1 1 DETAIL 2 1 THIS DRAWING SUPERSEDES D-5424_02 STATEOFWASHIN G T ONRE GISTEREDPROFE S SIONAL ENGINEERSENOJ KCEREZ 49481MIN1'-6"TYPICAL CATCH BASIN, TYPE 1a, DESIGN D DETAIL 4 1 IRON FRAME AND GRATE THE REVERSIBLE CAST ALL RISERS SHALL ACCEPT (WA STATE STD PLAN B-2a) FDRY NO. 5435 OR EQUAL) FRAME & GRATE (OLYMPIC REVERSIBLE CAST IRON COURSE 4" YARD TOP COURSE 3" YARD OR TOP OF 9" BASE COURSE INLET PIPE OUTLET PIPE STD. PLAN B-1a) 1a,DESIGN D (WA STATE CATCH BASIN, TYPE PLAN B-5.20-00) (WA STATE STANDARD CATCH BASIN, TYPE 1 2'-0" TAPER (TYP) 2'-0" 6" MIN (TYP) TAPER 6"MINPERFORATED DRAIN TYPICAL APPROVED EQUAL) PIPE (HANCOR HIGH-Q OR HIGH DENSITY POLYETHYLENE SMOOTH INTERIOR WALL, PERFORATED CORRUGATED, CAST FRAME INTO ADJUSTMENT SECTION OLYMPIC FDRY NO. SM 60 D/T OR EQUAL. GRATE (WA STATE STD PLAN B-30.50-03) (WA STATE STD PLAN B-30.10-03) & REVERSIBLE CAST IRON FRAME 9" BASE COURSE INLET PIPE OUTLET PIPE NOTE: FINISH GRADE FOR DRAINS WASHED AGGREGATE VARIES12" AMENDED SOIL MIN TRENCH WIDTH 6"O.D.6"6"PIPE ZONEO.D.6"DETAIL 3 1 (WSDOT STANDARD PLAN B-55.20-02) FOR GRAVEL BACKFILL FOR PIPE ZONE BEDDING. 1. SEE WSDOT STANDARD SPECIFICATIONS SECTION 9-03.12(3) NOTES: FOUNDATION LEVEL (SEE NOTE 1) PIPE ZONE BEDDING GRAVEL BACKFILL FOR HDPE/PVC PIPE TYPICAL PIPE BEDDING (TYP) 6" MIN (TYP) EXISTING SUBGRADE CITY OF RENTON R-417009 Know what'sbelow. before you dig.Call RTED-404170SCALE:FILE NO: SHEET: REV NODRAWING NO 2345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE SUBSTATION ENGINEERING DEPARTMENT CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CADD APPROVED WO NUMBER:12/28/20222:53:14 PMD-20895_02.dgnUSER: jinelsAS-BUILT c:\pwworking\projectwise\jinels\dms14623\D-20895_02.dgn INTERNAL USE