HomeMy WebLinkAboutUG Electrical Revisions at FrontageTRTRTR44444444430.82429.34428.48430.86429.50427.98427.25xxxxxxxxxxxxx4444444444444444444444444 4 444444444444444444444GENERATORGENERATORBACKUPFUEL TANKUTILITYTRANSFORMER& VAULTE7.0214"C - UTILITY PRIMARYFURNISHED BY UTILITYINSTALLED BY CONTRACTOR(E) UTILITY POLE W/ (E)POLE-MOUNT XFMR(E) UTILITY POLE W/(E) POLE-MOUNTXFMR TO REMAIN(E) UTILITY POLE W/(E) POLE-MOUNTXFMR TO REMAIN(E) OVERHEADSERVICE LATERAL -POWER & TV(E) UTILITY POLE(E) OVERHEADSERVICE LATERAL -POWER(E)WEATHERHEAD(E) STREETLUMINAIRE (TYP OF 2)(E) STREETLUMINIARE MOUNTEDTO UTILITY POLE(E) STREET LIGHTINGPEDESTAL(E) 37.5 KVA PAD-MOUNTEDUTILITY TRANSFORMER(E) TV PEDESTAL(E) TELEPHONE PEDESTAL(E) STREETLUMINAIRE (TYP OF 2)(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITYTHREE-PHASEOVERHEADDISTRIBUTION(E) UTILITY POLE(E) STREET LIGHTINGHANDHOLE (TYP)(E) SIGNALIZATIONPEDESTAL(E) STREET LIGHTINGPEDESTAL(E) UTILITY POWERMETER(E) TELEPHONEPEDESTAL(E) CATV AND PHONESERVICE AERIAL CABLINGTO REMAIN(E) OVERHEADSERVICE - CATVUTILITY JUNCTION VAULTFURNISHED BY UTILITYINSTALLED BY CONTRACTOR (1) 4"C - FURNISHED BYUTILITY INSTALLED BYCONTRACTORNEW THREE-PHASEOVERHEAD UTILITYDISTRIBUTION BY PSEE3E1E1E1E3E3E6E2E2E2E5E5 E5E5FGFGFGFGFG(2) 2-1/2"C - POWER(1) 2"C - FIRE ALARMV4V4(2) 1"C - FUTURE EVCHARGING STATIONS(1) 2"C - READERBOARDV3READERBOARDFAAPFAAP FACPGENERATORMANUALTRANSFERSWITCHNEW RENTONELEMENTARYSCHOOL #161(E) SERVICE1(E) SERVICE1222124"C - UTILITY PRIMARYFURNISHED BY UTILITYINSTALLED BY CONTRACTOR(E) SERVICE12(E) SERVICE12FUTURE EVCHARGINGSTATIONSFUTUREPORTABLESE5FGV3(1) 1"C - LIGHTING(1) 1"C - POWER(N) 2" CONDUIT RISERFURNISHED ANDINSTALLED BY UTILITY4(N) UTILITY POLE WITH (E) POLE-TOPTRANSFORMER AND (N) CONDUIT RISERSFURNISHED AND INSTALLED BY UTILITYNEW THREE-PHASEOVERHEAD UTILITYDISTRIBUTION BY PSE12(1) 2"C - POWERE2E4E4E3E3E5FGE5E5FG(2) 1"C - LIGHTINGV3FGE5E5E5FGFG(1) 1"C - POWER(1) 1"C - LIGHTINGV3(1) 1"C - LIGHTINGIRRIGATIONBOOSTER PUMPSEE CONTINUATIONTO IRRIGATIONCONTROLLER ONSHEET E3.12E5E5FGFGE4E2E4E6E5FGE4E4SL1SL1SL1SL1SL1E11GFWPGFWPFAAP LB1-9LB1-9LB1-9LB1-9LB1-9LB1-9LB1-7LB1-7LB1-7LB1-8LB1-8LB1-8LB1-8LB1-8LB1-8LB1-8LB1-8LB1-8LB1-11LA1-12LA1-12LA1-12LA1-12LA1-12LA1-12LA1-12LA1-12LA1-12LA1-10LA1-10LA1-10LA1-10LA1-10LA1-10LA1-10LA1-10P3A-43MA1-30,32,34P1A-26P1A-26SL2SL2SL1SL2SL1STREETLIGHTING PEDESTALSL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2E7.091,2E7.083,4E7.085,6E7.081,2(TYP)(TYP)(TYP)V5V5V5V5V5V5V5V5V5V5V5V5V5V5E7.086(TYP)E7.093DUVALL AVE NECHELAN AVE NESTREET LIGHTINGSERVICE LATERALSTREET LIGHTINGSERVICE POINT(IN 1324 HANDHOLE)335677FAAP (3) 10AFJ PIV1"C TOFACP(1) 2"C - POWERV5(1) SPARE 2"C FOR COMM8SL3V5SL2V5V5(1) SPARE 2"C FOR COMM8SL4SL2V5SL49101111004CCD004CCD004R1CCD004R1CCD004R1CCD004R1CCD004.2CCD004.2CCDVAULT SCHEDULEVAULT TYPEMANUFACTURERVAULT MODELCOVER MODELCOVER RATINGCOVER LABELVAULT DIMENSIONSNOTES(L X W X D)V1V2OLDCASTLE444-BL44-332PMEDIUM DUTY: H-20 OFF STREET4'-0" X 4'-0" X 4'-0"V3OLDCASTLEB1324 BOXN1324-51JHHEAVY DUTY: H-20 ROADWAYELECTRIC29-1/2" X 18-3/4" X 12"V4OLDCASTLE233-BL23-2436PMEDIUM DUTY: H-20 OFF STREETELECTRIC3'-8" X 2'-8" X 3'-6"V5OLDCASTLETYPE-1-MEDIUM DUTY: H-20 OFF STREETLT22"X17"X12"1NOTES1.COORDINATE WITH CITY OF RENTON REQUIREMENTS STANDARDS 119,120.2.3.FLAG NOTES:SHEET NOTES:1.REFER TO CIVIL, LANDSCAPE AND SURVEY DRAWINGS FOR ADDITIONAL INFORMATION.2.COORDINATE PLACEMENT OF SITE LIGHTING, VAULTS AND RACEWAY WITH DIVISION 31, CIVIL AND DIVISION 32,LANDSCAPE CONTRACTORS. COORDINATE WITH TREE PROTECTION PLANS AND AVOID CRITICAL ROOT ZONES OFEXISTING TREES. CONFLICTS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TOCOMMENCEMENT OF SITE WORK.3.COORDINATE ELECTRICAL UTILITY SERVICE AND OFF-SITE UTILITY ELECTRICAL WORK WITH PUGET SOUND ENERGYPRIOR TO COMMENCING WORK. INSTALLATION SHALL COMPLY WITH POWER COMPANY'S ELECTRICAL INSTALLATIONREQUIREMENTS. CONTACT JENNY CHAU WITH PUGET SOUND ENERGY AT 253-208-9480, JENNY.CHAU@PSE.COM FORADDITIONAL REQUIREMENTS.4.MINIMUM CONDUIT SIZE SHALL BE 1 INCH. MINIMUM CONDUCTOR SIZE SHALL BE #10 AWG FOR BRANCH CIRCUIT WORKSHOWN ON THIS SHEET.5.PROVIDE #8 AWG CONDUCTORS FOR LIGHTING BRANCH CIRCUIT WORK SHOWN ON THIS SHEET.6.PROVIDE A WATER-TIGHT SEAL FOR EACH UNDERGROUND RACEWAY ENTERING THE ELECTRICAL ROOM AFTERCONDUCTORS HAVE BEEN INSTALLED. REFER TO RACEWAY SPECIFICATION SECTION 260533 FOR ADDITIONALINFORMATION.7.REFER TO ONE-LINE DIAGRAM ON SHEET E9.01 FOR ADDITIONAL INFORMATION.8.ROUTE SITE LIGHTING CIRCUITS TO PANELS INDICATED VIA ASSOCIATED LIGHTING CONTROL PANELS. REFER TO E2SERIES DRAWINGS FOR SITE LIGHTING CONTROL REQUIREMENTS. PROVIDE WIRING AND CONTROL DEVICES REQUIREDFOR COMPLETE SYSTEM.9.INSTALL UNDERGROUND CONDUIT PER TRENCHING DETAIL. REFER TO DETAIL 3, SHEET E7.03.10.PROVIDE CONCRETE BASE FOR SITE LIGHTING POLES. REFER TO DETAILS 1 AND 2, SHEET E7.03 FOR ADDITIONALINFORMATION.11.REFER TO VAULT SCHEDULE ON THIS SHEET FOR VAULT AND HANDHOLE TYPES. REFER TO SPECIFICATIONSECTION 260543 FOR ADDITIONAL INFORMATION.12.PRIMARY CABLING IS PROVIDED BY UTILITY.COORDINATE RECONNECTION OF EXISTING SERVICES TO REMAIN FROM DEMOLISHED UTILITY POLETO BE FED FROM NEW RELOCATED POLE-TOP TRANSFORMER/UTILITY PRIMARY.NEW CONDUCTORS PROVIDED BY UTILITY TO RECONNECT EXISTING SERVICES TO REMAIN.MATERIAL SHALL BE FURNISHED AND INSTALLED BY UTILITY FROM EXISTING UTILITY POLE TOSERVICE POINT. PROVIDE EXCAVATION, TRENCHING, AND BACKFILL REQUIRED BY UTILITY. SEEONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.UTILITY SHALL PROVIDE REFEED OF PRIMARY SIDE OF EXISTING POLE-TOP TRANSFORMER.COORDINATE FINAL LOCATION WITH LANDSCAPE.COORDINATE FINAL LOCATION WITH CIVIL.PROVIDE ADDITIONAL HANDHOLE AT +24" TO CENTER INTEGRAL TO POLE FOR RECEPTACLEINDICATED.1234STREET LIGHTING NOTES:1.THE CONTRACTOR SHALL ACQUIRE AN ELECTRICAL PERMIT FROM THE CITY'S BUILDING DEPARTMENT. THE ELECTRICALPERMIT SHALL BE KEPT IN THE UPPER BAY OF THE SERVICE CABINET.2.UPON COMPLETION OF UNDERGROUND INSTALLATION OF POWER FROM POWER VAULT OR POLE TO SERVICE CABINET,NOTIFY THE BUILDING DEPARTMENT. UPON FINAL ELECTRICAL PERMIT APPROVAL, ELECTRICAL INSPECTOR WILL PLACEAN APPROVAL TAG NEXT TO THE METER BASE SO ELECTRICAL SERVICE CAN BE AUTHORIZED.3.COORDINATE POWER SOURCE AND SERVICE LOCATION WITH UTILITY.4.CONTACT THE UTILITIES UNDERGROUND LOCATION CENTER AT LEAST 3 DAYS PRIOR TO COMMENCING EARTHWORK.5.SEE CITY OF RENTON MUNICIPAL CODE AND SECTION J ILLUMINATION DESIGN STANDARDS FOR ADDITIONALINFORMATION.6.SEE STREET LIGHTING DETAILS ON SHEETS E7.08 AND E7.09 FOR ADDITIONAL INFORMATION.7.COORDINATE FINAL LOCATION OF STREET LIGHTING LUMINAIRE WITH CIVIL AND LANDSCAPE DRAWINGS. POLE SHALL BECENTERED IN CONCRETE HOUSEKEEPING PAD. CENTER OF POLE BASE SHALL BE 3'-0" FROM EDGE OF SIDEWALK AND 7'-0"FROM EDGE OF DUVALL AVENUE. LOCATE LIGHT POLE BASES, JUNCTION BOXES, AND CONCRETE PADS IN ACCORDANCEWITH CITY OF RENTON MUNICIPAL STANDARDS AND ALLOWING FOR LUMINAIRES TO ADHERE TO MAXIMUM ARM LENGTHREQUIREMENTS AND TO OVERHANG ROADWAY OR SIDEWALK BY MAXIMUM 2 FEET.8.DURING CONSTRUCTION, EXISTING ILLUMINATION LEVELS SHALLB E MAINTAINED BY KEEPING EXISTING ILLUMINATIONSYSTEM OPERTAIONAL, OR BY PROVIDING TEMP LIGHTING.9.FOR ILLUMINATION SYSTEMS COORDINATION WITH THE CITY OF RENTON, CONTRACTOR SHALL CONTACTTRANSPORTATION MAINTENANCE DEPARTMENT REPRESENTATIVE ERIC CUTSHALL AT (425) 430-7423.10.REFER TO GEOTECHNICAL REPORT AND WSDOT STANDARD PLAN J-28.30-03 FOR STREET LIGHTING POLE BASEFOUNDATION DESIGN.567004CCD004CCDFLAG NOTES:PROVIDE CONDUIT IN EXISTING LANDSCAPE BUFFER ON DUVALL SIDE OF EXISTING SIDEWALK.PROVIDE TRENCHING, COMPACTION, AND BACKFILL. COORDINATE INSTALLATION WITH EXISTINGUTILITIES & LANDSCAPE. INSTALL CONDUIT FROM V5 VAULT AT 10TH ST NE TO V5 VAULT AT 12TH STNECOORDINATE RECONNECTION OF EXISTING SERVICES TO REMAIN FROM DEMOLISHED UTILITY POLETO BE FED FROM NEW RELOCATED POLE-TOP TRANSFORMER/UTILITY PRIMARY.PROVIDE 5'X4'X17" (LXWXD) WORK PIT, 5-1/3 CUBIC YARD 6" CRUSHED ROCK PER UTILITY STANDARDS.PROVIDE TRENCHING, BACKFILL, COMPACTION, AND RESTORATION.COORDINATE TERMINATION OF STREET LIGHTING SERVICE SECONDARY.COORDINATE FINAL LOCATION OF STREET LIGHTING LUMINAIRE WITH CIVIL AND LANDSCAPEDRAWINGS. POLE SHALL BE CENTERED IN CONCRETE HOUSEKEEPING PAD.910118004CCD004R1CCD4010 LAKE WASHINGTON BLVD NESUITE 320KIRKLAND, WA 98033425.828.8948HOARCH.COMPROJECT INFORMATIONCONSULTANT STAMPARCHITECT STAMPSCHOOL DISTRICT LOGOPROJECT NUMBER:SHEET NAMESHEET NUMBER3.4.2022CONFORMED SETNewElementaryNo. 16ADDENDUM NO. 4Renton, WA 98059RENTON SCHOOL DISTRICTNO. 40311.4.2020SCHEMATIC DESIGN1.21.202150% DESIGN DEVELOPMENT3.26.2021100% DESIGN DEVELOPMENT8.27.2021PERMIT SUBMITTAL10.15.202175% CONTRACT DOCUMENTS12.3.202190% CD12.20.2021PERMIT RESUBMITTAL1.20.2022BP-06.11.24.2022BID SET2.3.2022ADDDENDUM NO. 12.10.2022ADDENDUM NO. 22.17.2022ADDENDUM NO. 32.24.2022ADDENDUM NO. 4CONFORMED SET3.4.2022201412345PR1ELECTRICAL SITE PLAN1SCALE: 1" = 40'-0"RONHTE1.00ElectricalSite Plan