HomeMy WebLinkAboutP_Civil Plan_Solera Block B_ Fire Sprinkler Underground Plan20220615_v3SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVAMUSTBESUBMITTEDTORENTONFIREPREVENTIONDEPARTMENTFORREVIEWANDAPPROVAL. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED. 1. MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY SHALL NOT BE MORETHAN50FEETTOBUILDING) 2. BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER3. CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) ALL PIPE ANDFITTINGSSHALLBERESTRAINEDWITHSHACKLERODSANDCONCRETETHRUSTBLOCKSPERNFPAANDAWWASTANDARDS. 4. POST—INDICATOR VALVE (MJ) WITH TAMPER SWITCH5. 2-90` BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6. 18" LONG SPOOL (FL x PE) 7. FLANGE COUPLING ADAPTOR 8. APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PERLATESTDEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVEFLOORLEVELANDNOTHIGHERTHAN3FEETMAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA9. O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & I 10. METERED 3/4 INCH BY—PASS DCVA — BY—PASS METER SHALL BE A 3/4 INCH "SENSUS—ECR" SR POSITIVE DISPLACEMENT METER EQUIPPEDICEREGISTERWITHAREMOTEREADSENSORPLATEMOUNTEDONTHE OUTSIDE OF THE BUILDING WALL (WALL MOUNT TYPE). 11. SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULTOROUTSIDEBUILDING 12. 4"x 4" x 6" BULL, ELBOW, THREADED13. UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY—PASS DCVAMUSTBETESTEDSATISFACTORILYBYADEPARTMENTOFHEALTHCERTIFIEDBACKFLOWASSEMBLYTESTER. TEST REPORT MUST BESUBMITTEDTOCITYOFRENTONWATERUTILITYENGINEERINGDEPARTMENTPRIORTOACTIVATIONOFNEWLINE. INSTALLBRASSY4" FLARE TEST COCKS WITH Y4„ FLARE CAPS. STANCHIONS BOLTED TO FLOOR. Y O INSIDE BUILDING INSTALL FOR 3" AND STD. PLAN — 360.5GashPUBLICWORKSLARGERDETECTORDOUBLECHECKDEPARTMENTVALVEASSEMBLYMARCH2010 CITYOWNEDANDMAINTAINED PRIVATELY OWNED AND MAINTAINED BUILDING WALLMAXIMUMPIPELENGTHFROMPROPERTYLINETODDCVAMUSTNOTEXCEED50FEET CONCRETE BOLLARDS x 2 3OO 4 10 cN O PERIMETERS OF MINIMUM CLEARANCES TOBEPAINTED ONFLOORIN WHITE1041:!S5FT. MAX. O ENAMEL PAINT STRIPE, WITH 2 INCH p N STENCILED BLACK LETTERS TO SAY: DO zz Z U a NOT BLOCK ACCESS" 3 J PG i yHSUFWILFWWJJOm IL a Q O zz0dWwooz4INCHN48INCH0J 13 12 11 ZNDDCVAMUSTBEINSTALLEDIMMEDIATELYAFTERPIPEPENETRATIONTHROUGHBUILDINGFLOORSLAB. wwROOMINWHICHDDCVAISLOCATEDSHALL: g A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. z LiB. HAVE AHEATING SYSTEM (40° F MIN. TEMP.) NO HEAT TAPE C. NOTBEUSED FORSTORAGE AROUND THEDDCVA m D. HAVE CLEARLYDELINEATED ACCESSWAYSTODDCVAAND PIVs. Cww ARIGHT—OF—ENTRY AGREEMENT MUST BE GRANTED TO THECITYOFRENTONFORINSPECTIONOFTHEDDCVA AND METER. OCLU) SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVAMUSTBESUBMITTEDTORENTONFIREPREVENTIONDEPARTMENTFORREVIEWANDAPPROVAL. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED. 1. MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY SHALL NOT BE MORETHAN50FEETTOBUILDING) 2. BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER3. CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) ALL PIPE ANDFITTINGSSHALLBERESTRAINEDWITHSHACKLERODSAND CONCRETETHRUSTBLOCKSPERNFPAANDAWWASTANDARDS. 4. POST—INDICATOR VALVE (MJ) WITH TAMPER SWITCH5. 2-90` BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6. 18" LONG SPOOL (FL x PE) 7. FLANGE COUPLING ADAPTOR 8. APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PERLATESTDEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVEFLOORLEVELANDNOTHIGHERTHAN3FEETMAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA9. O.S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L & I 10. METERED 3/4 INCH BY—PASS DCVA — BY—PASS METER SHALL BE A 3/4 INCH "SENSUS—ECR" SR POSITIVE DISPLACEMENT METER EQUIPPEDICEREGISTERWITHAREMOTEREADSENSORPLATEMOUNTEDONTHE OUTSIDE OF THE BUILDING WALL (WALL MOUNT TYPE). 11. SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULTOROUTSIDEBUILDING 12. 4"x 4" x 6" BULL, ELBOW, THREADED13. UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY—PASS DCVAMUSTBETESTEDSATISFACTORILYBYADEPARTMENTOFHEALTHCERTIFIEDBACKFLOWASSEMBLYTESTER. TEST REPORT MUST BESUBMITTEDTOCITYOFRENTONWATERUTILITYENGINEERINGDEPARTMENTPRIORTOACTIVATIONOFNEWLINE. INSTALLBRASSY4" FLARE TEST COCKS WITH Y4„ FLARE CAPS. STANCHIONS BOLTED TO FLOOR. Y O INSIDE BUILDING INSTALL FOR 3" AND STD. PLAN — 360.5GashPUBLICWORKSLARGERDETECTORDOUBLECHECKDEPARTMENTVALVEASSEMBLYMARCH2010 PIV REVISION Received: 06/15/2022 / striplett BUILDING DIVISION F22002908_v3By: cthomas Date: 06/16/2022 FIRE DEPARTMENT For Construction Subject to Corrections Noted in Red APPROVED SEE ATTACHED STANDARD CITY DETAIL NUMBER 360.5