Loading...
HomeMy WebLinkAboutEx_05_Drainage_Report CEKO C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com PRELIMINARY TECHNICAL INFORMATION REPORT GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON City of Renton Permit #: PRE21-000085 Submitted by: CEKO, L.L.C. 2255 Squak Mountain Loop, SW Issaquah, Washington 98027 CEKO PN: 22015.01 For: Magellan Architects 8383 158th Ave., NE Suite 280 Redmond, Washington 98052 October 6, 2022 Prepared by: Christopher P. Kovac, P.E. Exhibit 5 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO i C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com TABLE OF CONTENTS 1.0 PROJECT OVERVIEW ..................................................................................... 1-1 1.1 EXISTING SITE CONDITIONS AND HYDROLOGY ....................................... 1-1 1.2 PROPOSED SITE CONDITIONS AND HYDROLOGY ..................................... 1-2 2.0 CONDITIONS SUMMARY WITH RESPONSES ................................................... 2-1 2.1 APPROVAL CONDITIONS .......................................................................... 2-1 2.2 ADOPTED BASIN PLANS ........................................................................... 2-1 2.3 SEPA MITIGATION .................................................................................... 2-1 2.4 CORE REQUIREMENTS ............................................................................. 2-1 3.0 OFF-SITE ANALYSIS ....................................................................................... 3-1 4.0 HYDROLOGIC ANALYSIS AND DESIGN............................................................ 4-1 4.1 EXISTING SITE HYDROLOGY ..................................................................... 4-1 4.2 DEVELOPED SITE HYDROLOGY ................................................................. 4-1 4.3 PERFORMANCE STANDARDS ................................................................... 4-1 5.0 CONVEYANCE SYSTEM DESIGN AND ANALYSIS .............................................. 5-1 6.0 SPECIAL REPORTS AND STUDIES ................................................................... 6-1 7.0 OTHER LAND USE PERMITS ........................................................................... 7-1 8.0 DESIGN REQUIREMENTS FOR EROSION AND SEDIMENTATION CONTROL AND STORMWATER POLLUTION ...................................................................................... 8-1 9.0 BOND QUANTITIES, FACILITY SUMMARIES, AND PRIVATE COVENANTS ............................................................................................................ 9-1 10.0 OPERATIONS AND MAINTENANCE MANUAL ............................................... 10-1 11.0 BIBLIOGRAPHY ........................................................................................... 11-1 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO ii C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com FIGURES Figure 1 Site Location Map Figures 2A – 2E TIR Worksheets Figures 3A – 3C Drainage Review Requirements Figures Figure 4 Existing Conditions Figures 5A – 5E USDA NRCS Soils Mapping Information Figure 6 FEMA Flood Hazard Map Figure 7 Developed Conditions APPENDICES Appendix A WWHM Hydrologic Modeling Output Report DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 1-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 1.0 PROJECT OVERVIEW CEKO, L.L.C. (CEKO) has been contracted by Magellan Architects, project architect, to provide civil engineering design and consulting services in support of the proposed preschool playground improvements at 4110 Northeast 4th Street in Renton, Washington (herein referred to as the Site). The proposed improvements are to be constructed on an approximately 6,700-square-foot portion of a single parcel, consisting of King County Parcel No. 1023059128. The total parcel area encompasses approximately 3.56 acres of land. A Site location map is provided on Figure 1. It is anticipated that project construction will be completed in a single phase, with commencement of construction activities in 2023 and completion by the winter of 2023. This Technical Information Report (TIR) has been prepared to fulfill City of Renton Land Use and Building Permit application submittal requirements. This TIR includes descriptions and documentation demonstrating how the proposed project design will comply with the requirements set forth by the City of Renton in the adopted City of Renton Surface Water Design Manual, adopted on June 22, 2022 (RSWDM 2022), and the 2021 King County Surface Water Design Manual dated September 25, 2019 (KCSWDM 2021). A TIR worksheet is provided as Figures 2A through 2E in the building permit submittal issue of this report. It is anticipated that a Targeted Drainage Review, per Figures 3A through 3C (RSWDM 2022 Figure 1.1.2.A), is triggered for this project. 1.1 EXISTING SITE CONDITIONS AND HYDROLOGY The project Site area is approximately 6,700 square feet in the highlands of the City of Renton, Washington, and is currently developed as a grass area that is part of an existing commercial shopping center. The Site parcel is bordered as follows: · To the north by multi-family residential; · To the east and south, by other parcels of the same commercial shopping center, and the NE 4th Street right-of-way; and · To the west by commercial and multi-family commercial properties, and the Union Ave., NE right-of-way. See Figure 4 for a depiction of existing conditions. As reported by City of Renton staff, the Site is within the Black River Drainage Basin. Currently, the Site is served by an existing on-Site stormwater collection and management system constructed with the development of the commercial shopping center. Based on a review of information presented on COR MAPS, which is the City of Renton online GIS map system, stormwater runoff flows from the Site and the commercial shopping center are conveyed south via public surface water mains to a discharge to Maplewood Creek, near its headwater, just south of the NE 4th Street right-of-way. Maplewood Creek conveys flows southward to a confluence DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 1-2 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com with the Cedar River, near Maplewood Golf Course and Maple Valley Highway, also known as State Route 169. Based on a review of the USDA NRCS Web Soil Survey, the Site is underlain with Alderwood gravelly sandy loam with 8 percent to 15 percent slopes, abbreviated as AgC. AgC is considered a low permeability, till-like soil. See Figures 5A through 5E. Based on a review of date presented on the Federal Emergency Management Agency (FEMA) online Flood Insurance Rate Map (FIRM), Map No. 53033C0981G, the Site is an area designated as Zone X, which is defined as an area of minimal flood hazard. There are no known flood control facilities on or associated with the Site. See Figure 6. 1.2 PROPOSED SITE CONDITIONS AND HYDROLOGY The proposed project includes construction of the following improvements: · Tenant improvements, interior to the existing building; · Modifications to an existing loading dock; · Construction of a new preschool playground conforming to the standards of the Goddard School; · Construction of associated stormwater management facilities; and · Construction of additional and/or modified landscaping, where required. The new playground area is located on the north end of the existing on-Site building, in an area that is currently vegetated with mowed grass. See Figure 7 for a depiction of proposed developed conditions. The Site is in an area of the City of Renton which is required to meet the Peak Rate Flow Control Standard, which means that the site stormwater management system is required to match peak flow rates of the existing Site conditions for the 2-year, 10-year, and 100-year 24-hour design storm events (RSWDM 2022 1.2.3.1). The proposed stormwater management system for the Site will include detention in the void volume of the base rock beneath the proposed play area pervious surfaces. This approach is often used for synthetic turf athletic field projects and is desirable because of co-location of the flow control stormwater facility beneath the proposed play area and because the facility allows for partial infiltration within a substantial portion of the play area footprint. The proposed improvement surface areas are all non-pollution generating; therefore, no water quality facilities are proposed. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 2-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 2.0 CONDITIONS SUMMARY WITH RESPONSES 2.1 APPROVAL CONDITIONS Once issued, conditions of approval will be provided in an appendix of this report. The project is subject to the City of Renton Stormwater Standards, which, at the time of project vesting, follow the adopted RSWDM 2022 and KCSWDM 2021. These requirements are as described Section 2.2, Adopted Basin Plans. 2.2 ADOPTED BASIN PLANS The project is located within the City of Renton and in the Black River Drainage Basin. Other than the requirements defined by RSWDM 2022, no additional basin plan requirements are in effect. 2.3 STATE ENVIRONMENTAL POLICY ACT REVIEW AND MITIGATION The project size is below thresholds that would trigger review and mitigation under the Washington State Environmental Policy Act (SEPA). SEPA review is not required. 2.4 CORE REQUIREMENTS As described in Table 1.1.2.A of RSWDM 2022, and with the assumption that the project will be subject to Targeted Drainage Review, the project is anticipated to be required to meet the nine Core Drainage Requirements listed below. The six Special Drainage Requirements are not anticipated to be applicable to the project. 2.4.1 DISCHARGE AT NATURAL LOCATION The proposed improvements will not alter the discharge location for the Site. 2.4.2 OFF-SITE ANALYSIS A limited analysis of off-Site downstream drainage conditions has been completed in support of this preliminary report. Additional analyses can be completed if and as required and appropriate, after preliminary review by City of Renton staff of the proposed improvements. 2.4.3 FLOW CONTROL FACILITIES Flow control facilities are proposed, and are anticipated to include detention in the void volume of the base rock beneath the proposed play area pervious surfaces, limited infiltration within the footprint of the proposed play areas, and a flow control structure prior to discharge from the proposed detention system. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 2-2 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 2.4.4 CONVEYANCE SYSTEM The proposed improvements include conveyance system improvements with capacities to adequately convey runoff from the proposed detention system to the existing on-Site stormwater management facilities. 2.4.5 CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN The submitted Temporary Erosion and Sedimentation (TESC), and Demolition Plan, sheet C2.00 of the project engineering drawings set, provides the information required to meet the requirements of the Construction Stormwater Pollution Prevention Plan (CSWPP) Plan described in RSWDM 2022. 2.4.6 MAINTENANCE AND OPERATIONS The final version of this TIR will include maintenance and operations guidance and requirements for the proposed stormwater management facilities. 2.4.7 FINANCIAL GUARANTEES AND LIABILITY Financial guarantees, including cost estimates required to determine financial guarantee amounts, will be prepared and submitted prior to permit approval and as required by the City of Renton. Easements and/or Declarations of Covenants will also be prepared and submitted if and as required. 2.4.8 WATER QUALITY FACILITIES The proposed improvements are entirely non-pollution generating surface. Because of this, the requirement to include water quality facilities is not applicable. No water quality facilities are proposed. 2.4.9 ON-SITE BEST MANAGEMENT PRACTICES (BMPs) The proposed detention system will allow for limited include limited infiltration within the footprint of the proposed play areas, thereby meeting this requirement. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 3-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 3.0 OFF-SITE ANALYSIS The downstream flow route was reviewed on COR MAPS, which is the City of Renton online GIS map system. Based on a review of information presented on COR MAPS, which is the City of Renton online GIS map system, stormwater runoff flows from the Site and the commercial shopping center are conveyed south via public surface water mains to a discharge to Maplewood Creek, near its headwater, just south of the NE 4th Street right-of-way. Maplewood Creek conveys flows southward to a confluence with the Cedar River, near Maplewood Golf Course and Maple Valley Highway, also known as State Route 169. Additional offsite analyses, including a field review of the downstream flow path can be performed if and as required and appropriate, after preliminary review by City of Renton staff of the proposed improvements. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 4-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 4.0 HYDROLOGIC ANALYSIS AND DESIGN 4.1 EXISTING SITE HYDROLOGY The project Site area is approximately 6,700 square feet in the highlands of the City of Renton, Washington, and is currently developed as a grass area that is part of an existing commercial shopping center. The Site parcel is bordered as follows: · To the north by multi-family residential; · To the east and south, by other parcels of the same commercial shopping center, and the NE 4th Street right-of-way; and · To the west by commercial and multi-family commercial properties, and the Union Ave., NE right-of-way. See Figure 4 for a depiction of existing conditions. As reported by City of Renton staff, the Site is within the Black River Drainage Basin. Currently, the Site is served by an existing on-Site stormwater collection and management system constructed with the development of the commercial shopping center. Based on a review of information presented on COR MAPS, which is the City of Renton online GIS map system, stormwater runoff flows from the Site and the commercial shopping center are conveyed south via public surface water mains to a discharge to Maplewood Creek, near its headwater, just south of the NE 4th Street right-of-way. Maplewood Creek conveys flows southward to a confluence with the Cedar River, near Maplewood Golf Course and Maple Valley Highway, also known as State Route 169. Based on a review of the USDA NRCS Web Soil Survey, the Site is underlain with Alderwood gravelly sandy loam with 8 percent to 15 percent slopes, abbreviated as AgC. AgC is considered a low permeability, till-like soil. See Figures 5A through 5E. Based on a review of date presented on the Federal Emergency Management Agency (FEMA) online Flood Insurance Rate Map (FIRM), Map No. 53033C0981G, the Site is an area designated as Zone X, which is defined as an area of minimal flood hazard. There are no known flood control facilities on or associated with the Site. See Figure 6. 4.2 DEVELOPED SITE HYDROLOGY The proposed project includes construction of the following improvements: · Tenant improvements, interior to the existing building; · Modifications to an existing loading dock; · Construction of a new preschool playground conforming to the standards of the Goddard School; DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 4-2 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com · Construction of associated stormwater management facilities; and · Construction of additional and/or modified landscaping, where required. The new playground area is located on the north end of the existing on-Site building, in an area that is currently vegetated with mowed grass. See Figure 7 for a depiction of proposed developed conditions. The Site is in an area of the City of Renton which is required to meet the Peak Rate Flow Control Standard, which means that the site stormwater management system is required to match peak flow rates of the existing Site conditions for the 2-year, 10-year, and 100-year 24-hour design storm events (RSWDM 2022 1.2.3.1). The proposed stormwater management system for the Site will include detention in the void volume of the base rock beneath the proposed play area pervious surfaces. This approach is often used for synthetic turf athletic field projects and is desirable because of co-location of the flow control stormwater facility beneath the proposed play area and because the facility allows for partial infiltration within a substantial portion of the play area footprint. The proposed improvement surface areas are all non-pollution generating; therefore, no water quality facilities are proposed. 4.3 PERFORMANCE STANDARDS As stated above and as described in Table 1.1.2.A of RSWDM 2022, and with the assumption that the project will be subject to Targeted Drainage Review, the project is anticipated to be required to meet the nine Core Drainage Requirements listed below. The six Special Drainage Requirements are not anticipated to be applicable to the project. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 5-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 5.0 CONVEYANCE SYSTEM DESIGN AND ANALYSIS The proposed improvements include conveyance system improvements with capacities to adequately convey runoff from the proposed detention system to the existing on-Site stormwater management facilities. A quantitative capacity analysis will be prepared if and as required and appropriate, after preliminary review by City of Renton staff of the proposed improvements. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 6-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 6.0 SPECIAL REPORTS AND STUDIES Geotechnical Report No Geotechnical report is included as part of this project. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 7-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 7.0 OTHER LAND USE PERMITS Washington State Department of Transportation None required. Washington State Department of Ecology A Construction Stormwater General Permit, commonly referred to as a CSGP, is not required because the Site is less than 1 acre of land. City of Renton Demolition and Building permits will be applied for in conjunction with the project land use application. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 8-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 8.0 DESIGN REQUIREMENTS FOR EROSION AND SEDIMENTATION CONTROL AND STORMWATER POLLUTION Standard temporary erosion and sedimentation control (TESC) elements are required and presented on the project TESC and Demolition Plan, which is sheet C2.00 in the project plan set. The proposed TESC measures include: 1. Silt fences, aligned along the downhill perimeter of work areas; 2. Catch basin inserts, also known as inlet protection, placed in existing catch basins in the project area; 3. Straw wattles, placed where applicable around the existing, paved driveway area that will serve as the project staging area. The existing pavement, the straw wattles, and the relatively long paved driveway route to the street are intended to provide the protections normally addressed with a stabilized construction entrance; and 4. Temporary security fences, installed around construction areas, if and as needed to provide site security. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 9-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 9.0 BOND QUANTITIES, FACILITY SUMMARIES, AND PRIVATE COVENANTS As appropriate, a bond quantity worksheet will be prepared and submitted. Private covenants will be provided if and as required. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 10-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 10.0 OPERATIONS AND MAINTENANCE MANUAL If applicable and required, an operations and maintenance manual will be provided with the final permit submittal issue of this report. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO 11-1 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx CEKO, LLC ■ 425-864-8246 ■ 2255 Squak Mountain Loop SW ■ Issaquah, Washington 98027 ■ www.cekonw.com 11.0 BIBLIOGRAPHY City of Renton. 2022. City of Renton Surface Water Design Manual. June 22. Federal Emergency Management Agency (FEMA). 2020. FIRM Flood Insurance Rate Map, King County, Washington and Incorporated Areas, Map No. 53033C0680G. Accessed August 2, 2022. King County. 2022. King County iMap. <https://www.kingcounty.gov/services/gis/Maps/imap.aspx>. Accessed August 2, 2022. King County Department of Natural Resources and Parks (KCSWDM). 2016. King County, Washington Surface Water Design Manual. April. U.S. Department of Agriculture National Resource Conservation Service (NRCS). 2019. Web Soil Survey. <https://websoilsurvey.sc.egov.usda.gov/App/HomePage.htm>. Accessed August 2, 2022. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx FIGURES TECHNICAL INFORMATION REPORT Goddard Renton 4110 Northeast 4th Street Renton, Washington CEKO PN: 22015.01 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 REFERENCE: 7.5 MINUTE USGS QUADRANGLE RENTON, WASHINGTON. DATED 2020 2000 0 2000 SCALE IN FEET C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 1 SITE LOCATION MAP GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK SITE LOCATION WASHINGTON RENTON • DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 2A TIR WORKSHEET GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 2B TIR WORKSHEET GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 2C TIR WORKSHEET GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 2D TIR WORKSHEET GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 2E TIR WORKSHEET GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 3A DRAINAGE REVIEW REQUIREMENTS FLOW CHART GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 3B DRAINAGE REVIEW REQUIREMENTS GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 3C DRAINAGE REVIEW REQUIREMENTS GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 4 EXISTING CONDITIONS GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK 20 0 20 SCALE IN FEET DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 5A USDA NRCS SOILS MAP GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 5B USDA NRCS SOILS MAP LEGEND GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 5C USDA NRCS SOILS MAP UNIT LEGEND GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 5D USDA NRCS SOILS MAP UNIT DESCRIPTION GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 5E USDA NRCS SOILS MAP UNIT DESCRIPTION GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/6/2022 4:26 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 6 FEMA FLOOD HAZARD MAP GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 · · · ·C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\ACAD22015\CAD\22015.01-TIR-Figures.dwg 10/7/2022 1:25 PM (Chris Kovac)Drawn By:Checked By:CEKO PN: FIGURE 7 DEVELOPED CONDITIONS GODDARD RENTON 4110 NORTHEAST 4TH STREET RENTON, WASHINGTON 22015.01CPKCPK 20 0 20 SCALE IN FEET DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 CEKO C:\CEKO\Projects\Active\22015.01-Magellan-Goddard-Renton\Engineering\TIR\Goddard-Renton-TIR-2022-10-06.docx APPENDIX A WWHM HYDROLOGIC MODELING OUTPUT REPORT TECHNICAL INFORMATION REPORT Goddard Renton 4110 Northeast 4th Street Renton, Washington CEKO PN: 22015.01 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 WWHM2012 PROJECT REPORT DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 2 General Model Information Project Name:Goddard-Renton-001 Site Name:Goddard-Renton Site Address:4110 NE 4th Street City:Renton Report Date:10/6/2022 Gage:Seatac Data Start:1948/10/01 Data End:2009/09/30 Timestep:15 Minute Precip Scale:1.000 Version Date:2021/05/25 Version:4.2.16 POC Thresholds Low Flow Threshold for POC1:50 Percent of the 2 Year High Flow Threshold for POC1:50 Year DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 3 Landuse Basin Data Predeveloped Land Use Goddard-Renton Play Area Existing Bypass:No GroundWater:No Pervious Land Use acre C, Lawn, Flat 0.161 Pervious Total 0.161 Impervious Land Use acre Impervious Total 0 Basin Total 0.161 Element Flows To: Surface Interflow Groundwater DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 4 Mitigated Land Use Goddard-Renton Play Area Developed Bypass:No GroundWater:No Pervious Land Use acre C, Lawn, Flat 0.101 Pervious Total 0.101 Impervious Land Use acre SIDEWALKS FLAT 0.06 Impervious Total 0.06 Basin Total 0.161 Element Flows To: Surface Interflow Groundwater Gravel Trench Bed 1 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 5 Routing Elements Predeveloped Routing DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 6 Mitigated Routing Gravel Trench Bed 1 Bottom Length:42.00 ft. Bottom Width:42.00 ft. Trench bottom slope 1:0 To 1 Trench Left side slope 0:0 To 1 Trench right side slope 2:0 To 1 Material thickness of first layer:0.67 Pour Space of material for first layer:0.3 Material thickness of second layer:0 Pour Space of material for second layer:0 Material thickness of third layer:0 Pour Space of material for third layer:0 Infiltration On Infiltration rate:0.3 Infiltration safety factor:0.5 Total Volume Infiltrated (ac-ft.):9.486 Total Volume Through Riser (ac-ft.):0.039 Total Volume Through Facility (ac-ft.):9.525 Percent Infiltrated:99.59 Total Precip Applied to Facility:0 Total Evap From Facility:0 Discharge Structure Riser Height:0.5 ft. Riser Diameter:12 in. Element Flows To: Outlet 1 Outlet 2 Gravel Trench Bed Hydraulic Table Stage(feet)Area(ac.)Volume(ac-ft.)Discharge(cfs)Infilt(cfs) 0.0000 0.040 0.000 0.000 0.000 0.0074 0.040 0.000 0.000 0.006 0.0149 0.040 0.000 0.000 0.006 0.0223 0.040 0.000 0.000 0.006 0.0298 0.040 0.000 0.000 0.006 0.0372 0.040 0.000 0.000 0.006 0.0447 0.040 0.000 0.000 0.006 0.0521 0.040 0.000 0.000 0.006 0.0596 0.040 0.000 0.000 0.006 0.0670 0.040 0.000 0.000 0.006 0.0744 0.040 0.000 0.000 0.006 0.0819 0.040 0.001 0.000 0.006 0.0893 0.040 0.001 0.000 0.006 0.0968 0.040 0.001 0.000 0.006 0.1042 0.040 0.001 0.000 0.006 0.1117 0.040 0.001 0.000 0.006 0.1191 0.040 0.001 0.000 0.006 0.1266 0.040 0.001 0.000 0.006 0.1340 0.040 0.001 0.000 0.006 0.1414 0.040 0.001 0.000 0.006 0.1489 0.040 0.001 0.000 0.006 0.1563 0.040 0.001 0.000 0.006 0.1638 0.040 0.002 0.000 0.006 0.1712 0.040 0.002 0.000 0.006 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 7 0.1787 0.040 0.002 0.000 0.006 0.1861 0.040 0.002 0.000 0.006 0.1936 0.040 0.002 0.000 0.006 0.2010 0.040 0.002 0.000 0.006 0.2084 0.040 0.002 0.000 0.006 0.2159 0.040 0.002 0.000 0.006 0.2233 0.040 0.002 0.000 0.006 0.2308 0.040 0.002 0.000 0.006 0.2382 0.040 0.002 0.000 0.006 0.2457 0.040 0.003 0.000 0.006 0.2531 0.040 0.003 0.000 0.006 0.2606 0.040 0.003 0.000 0.006 0.2680 0.040 0.003 0.000 0.006 0.2754 0.040 0.003 0.000 0.006 0.2829 0.040 0.003 0.000 0.006 0.2903 0.040 0.003 0.000 0.006 0.2978 0.040 0.003 0.000 0.006 0.3052 0.040 0.003 0.000 0.006 0.3127 0.040 0.003 0.000 0.006 0.3201 0.040 0.003 0.000 0.006 0.3276 0.040 0.004 0.000 0.006 0.3350 0.040 0.004 0.000 0.006 0.3424 0.040 0.004 0.000 0.006 0.3499 0.040 0.004 0.000 0.006 0.3573 0.040 0.004 0.000 0.006 0.3648 0.040 0.004 0.000 0.006 0.3722 0.040 0.004 0.000 0.006 0.3797 0.040 0.004 0.000 0.006 0.3871 0.040 0.004 0.000 0.006 0.3946 0.040 0.004 0.000 0.006 0.4020 0.040 0.004 0.000 0.006 0.4094 0.040 0.005 0.000 0.006 0.4169 0.040 0.005 0.000 0.006 0.4243 0.040 0.005 0.000 0.006 0.4318 0.040 0.005 0.000 0.006 0.4392 0.040 0.005 0.000 0.006 0.4467 0.040 0.005 0.000 0.006 0.4541 0.040 0.005 0.000 0.006 0.4616 0.040 0.005 0.000 0.006 0.4690 0.040 0.005 0.000 0.006 0.4764 0.040 0.005 0.000 0.006 0.4839 0.040 0.005 0.000 0.006 0.4913 0.040 0.006 0.000 0.006 0.4988 0.040 0.006 0.000 0.006 0.5062 0.040 0.006 0.005 0.006 0.5137 0.040 0.006 0.017 0.006 0.5211 0.040 0.006 0.032 0.006 0.5286 0.040 0.006 0.051 0.006 0.5360 0.040 0.006 0.072 0.006 0.5434 0.040 0.006 0.096 0.006 0.5509 0.040 0.006 0.121 0.006 0.5583 0.040 0.006 0.149 0.006 0.5658 0.040 0.006 0.178 0.006 0.5732 0.040 0.007 0.209 0.006 0.5807 0.040 0.007 0.242 0.006 0.5881 0.040 0.007 0.276 0.006 0.5956 0.040 0.007 0.311 0.006 0.6030 0.040 0.007 0.348 0.006 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 8 0.6104 0.040 0.007 0.386 0.006 0.6179 0.040 0.007 0.425 0.006 0.6253 0.040 0.007 0.465 0.006 0.6328 0.040 0.007 0.506 0.006 0.6402 0.040 0.007 0.548 0.006 0.6477 0.040 0.007 0.591 0.006 0.6551 0.040 0.008 0.634 0.006 0.6626 0.040 0.008 0.678 0.006 0.6700 0.040 0.008 0.723 0.006 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:03:44 AM Page 9 Analysis Results POC 1 + Predeveloped x Mitigated Predeveloped Landuse Totals for POC #1 Total Pervious Area:0.161 Total Impervious Area:0 Mitigated Landuse Totals for POC #1 Total Pervious Area:0.101 Total Impervious Area:0.06 Flow Frequency Method:Log Pearson Type III 17B Flow Frequency Return Periods for Predeveloped. POC #1 Return Period Flow(cfs) 2 year 0.012681 5 year 0.023001 10 year 0.031399 25 year 0.043757 50 year 0.054221 100 year 0.065754 Flow Frequency Return Periods for Mitigated. POC #1 Return Period Flow(cfs) 2 year 0 5 year 0 10 year 0 25 year 0 50 year 0 100 year 0 Annual Peaks Annual Peaks for Predeveloped and Mitigated. POC #1 Year Predeveloped Mitigated 1949 0.027 0.000 1950 0.030 0.000 1951 0.014 0.005 1952 0.006 0.000 1953 0.004 0.000 1954 0.009 0.000 1955 0.010 0.000 1956 0.013 0.000 1957 0.015 0.000 1958 0.008 0.000 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 10 1959 0.007 0.000 1960 0.016 0.000 1961 0.011 0.000 1962 0.004 0.000 1963 0.011 0.000 1964 0.012 0.000 1965 0.018 0.000 1966 0.006 0.000 1967 0.030 0.000 1968 0.014 0.000 1969 0.016 0.000 1970 0.010 0.000 1971 0.016 0.000 1972 0.026 0.000 1973 0.005 0.000 1974 0.014 0.000 1975 0.017 0.000 1976 0.011 0.000 1977 0.009 0.000 1978 0.010 0.000 1979 0.003 0.000 1980 0.032 0.000 1981 0.009 0.000 1982 0.028 0.037 1983 0.014 0.000 1984 0.008 0.000 1985 0.010 0.000 1986 0.013 0.004 1987 0.013 0.000 1988 0.005 0.000 1989 0.004 0.000 1990 0.061 0.035 1991 0.038 0.017 1992 0.009 0.000 1993 0.005 0.000 1994 0.004 0.000 1995 0.009 0.000 1996 0.026 0.000 1997 0.016 0.010 1998 0.011 0.000 1999 0.044 0.000 2000 0.012 0.000 2001 0.003 0.000 2002 0.024 0.000 2003 0.019 0.000 2004 0.030 0.038 2005 0.013 0.000 2006 0.014 0.000 2007 0.056 0.023 2008 0.037 0.043 2009 0.019 0.000 Ranked Annual Peaks Ranked Annual Peaks for Predeveloped and Mitigated. POC #1 Rank Predeveloped Mitigated 1 0.0605 0.0432 2 0.0563 0.0378 3 0.0441 0.0367 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 11 4 0.0378 0.0351 5 0.0370 0.0232 6 0.0322 0.0165 7 0.0301 0.0100 8 0.0300 0.0046 9 0.0296 0.0043 10 0.0285 0.0001 11 0.0266 0.0000 12 0.0258 0.0000 13 0.0257 0.0000 14 0.0242 0.0000 15 0.0189 0.0000 16 0.0189 0.0000 17 0.0175 0.0000 18 0.0167 0.0000 19 0.0164 0.0000 20 0.0156 0.0000 21 0.0156 0.0000 22 0.0156 0.0000 23 0.0154 0.0000 24 0.0144 0.0000 25 0.0142 0.0000 26 0.0140 0.0000 27 0.0139 0.0000 28 0.0137 0.0000 29 0.0134 0.0000 30 0.0132 0.0000 31 0.0130 0.0000 32 0.0128 0.0000 33 0.0118 0.0000 34 0.0115 0.0000 35 0.0115 0.0000 36 0.0112 0.0000 37 0.0110 0.0000 38 0.0109 0.0000 39 0.0104 0.0000 40 0.0100 0.0000 41 0.0100 0.0000 42 0.0098 0.0000 43 0.0094 0.0000 44 0.0093 0.0000 45 0.0093 0.0000 46 0.0087 0.0000 47 0.0085 0.0000 48 0.0085 0.0000 49 0.0076 0.0000 50 0.0066 0.0000 51 0.0064 0.0000 52 0.0058 0.0000 53 0.0055 0.0000 54 0.0052 0.0000 55 0.0046 0.0000 56 0.0041 0.0000 57 0.0037 0.0000 58 0.0036 0.0000 59 0.0036 0.0000 60 0.0034 0.0000 61 0.0031 0.0000 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 12 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 13 Duration Flows The Facility PASSED Flow(cfs)Predev Mit Percentage Pass/Fail 0.0063 3480 97 2 Pass 0.0068 2710 95 3 Pass 0.0073 2214 92 4 Pass 0.0078 1824 85 4 Pass 0.0083 1449 84 5 Pass 0.0088 1214 80 6 Pass 0.0092 974 76 7 Pass 0.0097 766 71 9 Pass 0.0102 603 68 11 Pass 0.0107 467 64 13 Pass 0.0112 385 61 15 Pass 0.0117 314 60 19 Pass 0.0121 250 58 23 Pass 0.0126 220 58 26 Pass 0.0131 180 57 31 Pass 0.0136 153 56 36 Pass 0.0141 135 51 37 Pass 0.0146 124 48 38 Pass 0.0150 116 46 39 Pass 0.0155 109 44 40 Pass 0.0160 99 43 43 Pass 0.0165 91 42 46 Pass 0.0170 86 39 45 Pass 0.0175 82 38 46 Pass 0.0179 78 37 47 Pass 0.0184 76 36 47 Pass 0.0189 71 34 47 Pass 0.0194 68 34 50 Pass 0.0199 66 32 48 Pass 0.0204 62 31 50 Pass 0.0208 61 29 47 Pass 0.0213 57 29 50 Pass 0.0218 53 26 49 Pass 0.0223 49 26 53 Pass 0.0228 48 26 54 Pass 0.0233 45 25 55 Pass 0.0238 43 22 51 Pass 0.0242 38 20 52 Pass 0.0247 37 19 51 Pass 0.0252 36 18 50 Pass 0.0257 35 16 45 Pass 0.0262 33 14 42 Pass 0.0267 30 12 40 Pass 0.0271 30 11 36 Pass 0.0276 28 10 35 Pass 0.0281 26 8 30 Pass 0.0286 24 7 29 Pass 0.0291 22 7 31 Pass 0.0296 22 7 31 Pass 0.0300 19 7 36 Pass 0.0305 18 6 33 Pass 0.0310 15 6 40 Pass 0.0315 15 6 40 Pass DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 14 0.0320 13 6 46 Pass 0.0325 11 6 54 Pass 0.0329 11 5 45 Pass 0.0334 10 5 50 Pass 0.0339 9 5 55 Pass 0.0344 9 5 55 Pass 0.0349 8 5 62 Pass 0.0354 8 4 50 Pass 0.0358 8 4 50 Pass 0.0363 7 4 57 Pass 0.0368 7 3 42 Pass 0.0373 6 3 50 Pass 0.0378 6 3 50 Pass 0.0383 5 2 40 Pass 0.0387 5 2 40 Pass 0.0392 5 2 40 Pass 0.0397 5 2 40 Pass 0.0402 5 1 20 Pass 0.0407 5 1 20 Pass 0.0412 5 1 20 Pass 0.0416 4 1 25 Pass 0.0421 4 1 25 Pass 0.0426 4 1 25 Pass 0.0431 3 1 33 Pass 0.0436 3 0 0 Pass 0.0441 3 0 0 Pass 0.0445 2 0 0 Pass 0.0450 2 0 0 Pass 0.0455 2 0 0 Pass 0.0460 2 0 0 Pass 0.0465 2 0 0 Pass 0.0470 2 0 0 Pass 0.0475 2 0 0 Pass 0.0479 2 0 0 Pass 0.0484 2 0 0 Pass 0.0489 2 0 0 Pass 0.0494 2 0 0 Pass 0.0499 2 0 0 Pass 0.0504 2 0 0 Pass 0.0508 2 0 0 Pass 0.0513 2 0 0 Pass 0.0518 2 0 0 Pass 0.0523 2 0 0 Pass 0.0528 2 0 0 Pass 0.0533 2 0 0 Pass 0.0537 2 0 0 Pass 0.0542 2 0 0 Pass DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 15 Water Quality Water Quality BMP Flow and Volume for POC #1 On-line facility volume:0 acre-feet On-line facility target flow:0 cfs. Adjusted for 15 min:0 cfs. Off-line facility target flow:0 cfs. Adjusted for 15 min:0 cfs. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:08 AM Page 16 LID Report DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:14 AM Page 17 Model Default Modifications Total of 0 changes have been made. PERLND Changes No PERLND changes have been made. IMPLND Changes No IMPLND changes have been made. DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:14 AM Page 18 Appendix Predeveloped Schematic DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:14 AM Page 19 Mitigated Schematic DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 20 Predeveloped UCI File RUN GLOBAL WWHM4 model simulation START 1948 10 01 END 2009 09 30 RUN INTERP OUTPUT LEVEL 3 0 RESUME 0 RUN 1 UNIT SYSTEM 1 END GLOBAL FILES <File> <Un#> <-----------File Name------------------------------>*** <-ID-> *** WDM 26 Goddard-Renton-001.wdm MESSU 25 PreGoddard-Renton-001.MES 27 PreGoddard-Renton-001.L61 28 PreGoddard-Renton-001.L62 30 POCGoddard-Renton-0011.dat END FILES OPN SEQUENCE INGRP INDELT 00:15 PERLND 16 COPY 501 DISPLY 1 END INGRP END OPN SEQUENCE DISPLY DISPLY-INFO1 # - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND 1 Goddard-Renton Play Area MAX 1 2 30 9 END DISPLY-INFO1 END DISPLY COPY TIMESERIES # - # NPT NMN *** 1 1 1 501 1 1 END TIMESERIES END COPY GENER OPCODE # # OPCD *** END OPCODE PARM # # K *** END PARM END GENER PERLND GEN-INFO <PLS ><-------Name------->NBLKS Unit-systems Printer *** # - # User t-series Engl Metr *** in out *** 16 C, Lawn, Flat 1 1 1 1 27 0 END GEN-INFO *** Section PWATER*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *** 16 0 0 1 0 0 0 0 0 0 0 0 0 END ACTIVITY PRINT-INFO <PLS > ***************** Print-flags ***************************** PIVL PYR # - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ********* 16 0 0 4 0 0 0 0 0 0 0 0 0 1 9 END PRINT-INFO DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 21 PWAT-PARM1 <PLS > PWATER variable monthly parameter value flags *** # - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT *** 16 0 0 0 0 0 0 0 0 0 0 0 END PWAT-PARM1 PWAT-PARM2 <PLS > PWATER input info: Part 2 *** # - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC 16 0 4.5 0.03 400 0.05 0.5 0.996 END PWAT-PARM2 PWAT-PARM3 <PLS > PWATER input info: Part 3 *** # - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP 16 0 0 2 2 0 0 0 END PWAT-PARM3 PWAT-PARM4 <PLS > PWATER input info: Part 4 *** # - # CEPSC UZSN NSUR INTFW IRC LZETP *** 16 0.1 0.25 0.25 6 0.5 0.25 END PWAT-PARM4 PWAT-STATE1 <PLS > *** Initial conditions at start of simulation ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 *** # - # *** CEPS SURS UZS IFWS LZS AGWS GWVS 16 0 0 0 0 2.5 1 0 END PWAT-STATE1 END PERLND IMPLND GEN-INFO <PLS ><-------Name-------> Unit-systems Printer *** # - # User t-series Engl Metr *** in out *** END GEN-INFO *** Section IWATER*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # ATMP SNOW IWAT SLD IWG IQAL *** END ACTIVITY PRINT-INFO <ILS > ******** Print-flags ******** PIVL PYR # - # ATMP SNOW IWAT SLD IWG IQAL ********* END PRINT-INFO IWAT-PARM1 <PLS > IWATER variable monthly parameter value flags *** # - # CSNO RTOP VRS VNN RTLI *** END IWAT-PARM1 IWAT-PARM2 <PLS > IWATER input info: Part 2 *** # - # *** LSUR SLSUR NSUR RETSC END IWAT-PARM2 IWAT-PARM3 <PLS > IWATER input info: Part 3 *** # - # ***PETMAX PETMIN END IWAT-PARM3 IWAT-STATE1 <PLS > *** Initial conditions at start of simulation # - # *** RETS SURS END IWAT-STATE1 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 22 END IMPLND SCHEMATIC <-Source-> <--Area--> <-Target-> MBLK *** <Name> # <-factor-> <Name> # Tbl# *** Goddard-Renton Play Area Existing*** PERLND 16 0.161 COPY 501 12 PERLND 16 0.161 COPY 501 13 ******Routing****** END SCHEMATIC NETWORK <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # #<-factor->strg <Name> # # <Name> # # *** COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1 <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # #<-factor->strg <Name> # # <Name> # # *** END NETWORK RCHRES GEN-INFO RCHRES Name Nexits Unit Systems Printer *** # - #<------------------><---> User T-series Engl Metr LKFG *** in out *** END GEN-INFO *** Section RCHRES*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG *** END ACTIVITY PRINT-INFO <PLS > ***************** Print-flags ******************* PIVL PYR # - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR ********* END PRINT-INFO HYDR-PARM1 RCHRES Flags for each HYDR Section *** # - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each FG FG FG FG possible exit *** possible exit possible exit * * * * * * * * * * * * * * *** END HYDR-PARM1 HYDR-PARM2 # - # FTABNO LEN DELTH STCOR KS DB50 *** <------><--------><--------><--------><--------><--------><--------> *** END HYDR-PARM2 HYDR-INIT RCHRES Initial conditions for each HYDR section *** # - # *** VOL Initial value of COLIND Initial value of OUTDGT *** ac-ft for each possible exit for each possible exit <------><--------> <---><---><---><---><---> *** <---><---><---><---><---> END HYDR-INIT END RCHRES SPEC-ACTIONS END SPEC-ACTIONS FTABLES END FTABLES EXT SOURCES <-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # *** WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 23 WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP END EXT SOURCES EXT TARGETS <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd *** <Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg*** COPY 501 OUTPUT MEAN 1 1 48.4 WDM 501 FLOW ENGL REPL END EXT TARGETS MASS-LINK <Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->*** <Name> <Name> # #<-factor-> <Name> <Name> # #*** MASS-LINK 12 PERLND PWATER SURO 0.083333 COPY INPUT MEAN END MASS-LINK 12 MASS-LINK 13 PERLND PWATER IFWO 0.083333 COPY INPUT MEAN END MASS-LINK 13 END MASS-LINK END RUN DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 24 Mitigated UCI File RUN GLOBAL WWHM4 model simulation START 1948 10 01 END 2009 09 30 RUN INTERP OUTPUT LEVEL 3 0 RESUME 0 RUN 1 UNIT SYSTEM 1 END GLOBAL FILES <File> <Un#> <-----------File Name------------------------------>*** <-ID-> *** WDM 26 Goddard-Renton-001.wdm MESSU 25 MitGoddard-Renton-001.MES 27 MitGoddard-Renton-001.L61 28 MitGoddard-Renton-001.L62 30 POCGoddard-Renton-0011.dat END FILES OPN SEQUENCE INGRP INDELT 00:15 PERLND 16 IMPLND 8 RCHRES 1 COPY 1 COPY 501 DISPLY 1 END INGRP END OPN SEQUENCE DISPLY DISPLY-INFO1 # - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND 1 Gravel Trench Bed 1 MAX 1 2 30 9 END DISPLY-INFO1 END DISPLY COPY TIMESERIES # - # NPT NMN *** 1 1 1 501 1 1 END TIMESERIES END COPY GENER OPCODE # # OPCD *** END OPCODE PARM # # K *** END PARM END GENER PERLND GEN-INFO <PLS ><-------Name------->NBLKS Unit-systems Printer *** # - # User t-series Engl Metr *** in out *** 16 C, Lawn, Flat 1 1 1 1 27 0 END GEN-INFO *** Section PWATER*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *** 16 0 0 1 0 0 0 0 0 0 0 0 0 END ACTIVITY PRINT-INFO <PLS > ***************** Print-flags ***************************** PIVL PYR # - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ********* DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 25 16 0 0 4 0 0 0 0 0 0 0 0 0 1 9 END PRINT-INFO PWAT-PARM1 <PLS > PWATER variable monthly parameter value flags *** # - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT *** 16 0 0 0 0 0 0 0 0 0 0 0 END PWAT-PARM1 PWAT-PARM2 <PLS > PWATER input info: Part 2 *** # - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC 16 0 4.5 0.03 400 0.05 0.5 0.996 END PWAT-PARM2 PWAT-PARM3 <PLS > PWATER input info: Part 3 *** # - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP 16 0 0 2 2 0 0 0 END PWAT-PARM3 PWAT-PARM4 <PLS > PWATER input info: Part 4 *** # - # CEPSC UZSN NSUR INTFW IRC LZETP *** 16 0.1 0.25 0.25 6 0.5 0.25 END PWAT-PARM4 PWAT-STATE1 <PLS > *** Initial conditions at start of simulation ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 *** # - # *** CEPS SURS UZS IFWS LZS AGWS GWVS 16 0 0 0 0 2.5 1 0 END PWAT-STATE1 END PERLND IMPLND GEN-INFO <PLS ><-------Name-------> Unit-systems Printer *** # - # User t-series Engl Metr *** in out *** 8 SIDEWALKS/FLAT 1 1 1 27 0 END GEN-INFO *** Section IWATER*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # ATMP SNOW IWAT SLD IWG IQAL *** 8 0 0 1 0 0 0 END ACTIVITY PRINT-INFO <ILS > ******** Print-flags ******** PIVL PYR # - # ATMP SNOW IWAT SLD IWG IQAL ********* 8 0 0 4 0 0 0 1 9 END PRINT-INFO IWAT-PARM1 <PLS > IWATER variable monthly parameter value flags *** # - # CSNO RTOP VRS VNN RTLI *** 8 0 0 0 0 0 END IWAT-PARM1 IWAT-PARM2 <PLS > IWATER input info: Part 2 *** # - # *** LSUR SLSUR NSUR RETSC 8 400 0.01 0.1 0.1 END IWAT-PARM2 IWAT-PARM3 <PLS > IWATER input info: Part 3 *** DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 26 # - # ***PETMAX PETMIN 8 0 0 END IWAT-PARM3 IWAT-STATE1 <PLS > *** Initial conditions at start of simulation # - # *** RETS SURS 8 0 0 END IWAT-STATE1 END IMPLND SCHEMATIC <-Source-> <--Area--> <-Target-> MBLK *** <Name> # <-factor-> <Name> # Tbl# *** Goddard-Renton Play Area Developed*** PERLND 16 0.101 RCHRES 1 2 IMPLND 8 0.06 RCHRES 1 5 ******Routing****** PERLND 16 0.101 COPY 1 12 IMPLND 8 0.06 COPY 1 15 RCHRES 1 1 COPY 501 17 END SCHEMATIC NETWORK <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # #<-factor->strg <Name> # # <Name> # # *** COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1 <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # #<-factor->strg <Name> # # <Name> # # *** END NETWORK RCHRES GEN-INFO RCHRES Name Nexits Unit Systems Printer *** # - #<------------------><---> User T-series Engl Metr LKFG *** in out *** 1 Gravel Trench Be-007 2 1 1 1 28 0 1 END GEN-INFO *** Section RCHRES*** ACTIVITY <PLS > ************* Active Sections ***************************** # - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG *** 1 1 0 0 0 0 0 0 0 0 0 END ACTIVITY PRINT-INFO <PLS > ***************** Print-flags ******************* PIVL PYR # - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR ********* 1 4 0 0 0 0 0 0 0 0 0 1 9 END PRINT-INFO HYDR-PARM1 RCHRES Flags for each HYDR Section *** # - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each FG FG FG FG possible exit *** possible exit possible exit * * * * * * * * * * * * * * *** 1 0 1 0 0 4 5 0 0 0 0 0 0 0 0 2 2 2 2 2 END HYDR-PARM1 HYDR-PARM2 # - # FTABNO LEN DELTH STCOR KS DB50 *** <------><--------><--------><--------><--------><--------><--------> *** 1 1 0.01 0.0 0.0 0.5 0.0 END HYDR-PARM2 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 27 HYDR-INIT RCHRES Initial conditions for each HYDR section *** # - # *** VOL Initial value of COLIND Initial value of OUTDGT *** ac-ft for each possible exit for each possible exit <------><--------> <---><---><---><---><---> *** <---><---><---><---><---> 1 0 4.0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 END HYDR-INIT END RCHRES SPEC-ACTIONS END SPEC-ACTIONS FTABLES FTABLE 1 92 5 Depth Area Volume Outflow1 Outflow2 Velocity Travel Time*** (ft) (acres) (acre-ft) (cfs) (cfs) (ft/sec) (Minutes)*** 0.000000 0.040496 0.000000 0.000000 0.000000 0.007444 0.040496 0.000090 0.000000 0.006125 0.014889 0.040496 0.000181 0.000000 0.006125 0.022333 0.040496 0.000271 0.000000 0.006125 0.029778 0.040496 0.000362 0.000000 0.006125 0.037222 0.040496 0.000452 0.000000 0.006125 0.044667 0.040496 0.000543 0.000000 0.006125 0.052111 0.040496 0.000633 0.000000 0.006125 0.059556 0.040496 0.000724 0.000000 0.006125 0.067000 0.040496 0.000814 0.000000 0.006125 0.074444 0.040496 0.000904 0.000000 0.006125 0.081889 0.040496 0.000995 0.000000 0.006125 0.089333 0.040496 0.001085 0.000000 0.006125 0.096778 0.040496 0.001176 0.000000 0.006125 0.104222 0.040496 0.001266 0.000000 0.006125 0.111667 0.040496 0.001357 0.000000 0.006125 0.119111 0.040496 0.001447 0.000000 0.006125 0.126556 0.040496 0.001537 0.000000 0.006125 0.134000 0.040496 0.001628 0.000000 0.006125 0.141444 0.040496 0.001718 0.000000 0.006125 0.148889 0.040496 0.001809 0.000000 0.006125 0.156333 0.040496 0.001899 0.000000 0.006125 0.163778 0.040496 0.001990 0.000000 0.006125 0.171222 0.040496 0.002080 0.000000 0.006125 0.178667 0.040496 0.002171 0.000000 0.006125 0.186111 0.040496 0.002261 0.000000 0.006125 0.193556 0.040496 0.002351 0.000000 0.006125 0.201000 0.040496 0.002442 0.000000 0.006125 0.208444 0.040496 0.002532 0.000000 0.006125 0.215889 0.040496 0.002623 0.000000 0.006125 0.223333 0.040496 0.002713 0.000000 0.006125 0.230778 0.040496 0.002804 0.000000 0.006125 0.238222 0.040496 0.002894 0.000000 0.006125 0.245667 0.040496 0.002985 0.000000 0.006125 0.253111 0.040496 0.003075 0.000000 0.006125 0.260556 0.040496 0.003165 0.000000 0.006125 0.268000 0.040496 0.003256 0.000000 0.006125 0.275444 0.040496 0.003346 0.000000 0.006125 0.282889 0.040496 0.003437 0.000000 0.006125 0.290333 0.040496 0.003527 0.000000 0.006125 0.297778 0.040496 0.003618 0.000000 0.006125 0.305222 0.040496 0.003708 0.000000 0.006125 0.312667 0.040496 0.003799 0.000000 0.006125 0.320111 0.040496 0.003889 0.000000 0.006125 0.327556 0.040496 0.003979 0.000000 0.006125 0.335000 0.040496 0.004070 0.000000 0.006125 0.342444 0.040496 0.004160 0.000000 0.006125 0.349889 0.040496 0.004251 0.000000 0.006125 0.357333 0.040496 0.004341 0.000000 0.006125 0.364778 0.040496 0.004432 0.000000 0.006125 0.372222 0.040496 0.004522 0.000000 0.006125 0.379667 0.040496 0.004612 0.000000 0.006125 0.387111 0.040496 0.004703 0.000000 0.006125 0.394556 0.040496 0.004793 0.000000 0.006125 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 28 0.402000 0.040496 0.004884 0.000000 0.006125 0.409444 0.040496 0.004974 0.000000 0.006125 0.416889 0.040496 0.005065 0.000000 0.006125 0.424333 0.040496 0.005155 0.000000 0.006125 0.431778 0.040496 0.005246 0.000000 0.006125 0.439222 0.040496 0.005336 0.000000 0.006125 0.446667 0.040496 0.005426 0.000000 0.006125 0.454111 0.040496 0.005517 0.000000 0.006125 0.461556 0.040496 0.005607 0.000000 0.006125 0.469000 0.040496 0.005698 0.000000 0.006125 0.476444 0.040496 0.005788 0.000000 0.006125 0.483889 0.040496 0.005879 0.000000 0.006125 0.491333 0.040496 0.005969 0.000000 0.006125 0.498778 0.040496 0.006060 0.000000 0.006125 0.506222 0.040496 0.006150 0.005211 0.006125 0.513667 0.040496 0.006240 0.016957 0.006125 0.521111 0.040496 0.006331 0.032545 0.006125 0.528556 0.040496 0.006421 0.051183 0.006125 0.536000 0.040496 0.006512 0.072430 0.006125 0.543444 0.040496 0.006602 0.095992 0.006125 0.550889 0.040496 0.006693 0.121651 0.006125 0.558333 0.040496 0.006783 0.149239 0.006125 0.565778 0.040496 0.006873 0.178613 0.006125 0.573222 0.040496 0.006964 0.209654 0.006125 0.580667 0.040496 0.007054 0.242254 0.006125 0.588111 0.040496 0.007145 0.276316 0.006125 0.595556 0.040496 0.007235 0.311748 0.006125 0.603000 0.040496 0.007326 0.348467 0.006125 0.610444 0.040496 0.007416 0.386387 0.006125 0.617889 0.040496 0.007507 0.425429 0.006125 0.625333 0.040496 0.007597 0.465514 0.006125 0.632778 0.040496 0.007687 0.506562 0.006125 0.640222 0.040496 0.007778 0.548496 0.006125 0.647667 0.040496 0.007868 0.591236 0.006125 0.655111 0.040496 0.007959 0.634704 0.006125 0.662556 0.040496 0.008049 0.678821 0.006125 0.670000 0.040496 0.008140 0.723505 0.006125 0.677444 0.040496 0.008441 0.768676 0.006125 END FTABLE 1 END FTABLES EXT SOURCES <-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> *** <Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # *** WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP END EXT SOURCES EXT TARGETS <-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd *** <Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg*** RCHRES 1 HYDR RO 1 1 1 WDM 1000 FLOW ENGL REPL RCHRES 1 HYDR O 1 1 1 WDM 1001 FLOW ENGL REPL RCHRES 1 HYDR O 2 1 1 WDM 1002 FLOW ENGL REPL RCHRES 1 HYDR STAGE 1 1 1 WDM 1003 STAG ENGL REPL COPY 1 OUTPUT MEAN 1 1 48.4 WDM 701 FLOW ENGL REPL COPY 501 OUTPUT MEAN 1 1 48.4 WDM 801 FLOW ENGL REPL END EXT TARGETS MASS-LINK <Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->*** <Name> <Name> # #<-factor-> <Name> <Name> # #*** MASS-LINK 2 PERLND PWATER SURO 0.083333 RCHRES INFLOW IVOL END MASS-LINK 2 MASS-LINK 5 DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 29 IMPLND IWATER SURO 0.083333 RCHRES INFLOW IVOL END MASS-LINK 5 MASS-LINK 12 PERLND PWATER SURO 0.083333 COPY INPUT MEAN END MASS-LINK 12 MASS-LINK 15 IMPLND IWATER SURO 0.083333 COPY INPUT MEAN END MASS-LINK 15 MASS-LINK 17 RCHRES OFLOW OVOL 1 COPY INPUT MEAN END MASS-LINK 17 END MASS-LINK END RUN DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 30 Predeveloped HSPF Message File DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 31 Mitigated HSPF Message File DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47 Goddard-Renton-001 10/6/2022 10:04:15 AM Page 32 Disclaimer Legal Notice This program and accompanying documentation is provided 'as-is' without warranty of any kind. The entire risk regarding the performance and results of this program is assumed by the user. Clear Creek Solutions, Inc. disclaims all warranties, either expressed or implied, including but not limited to implied warranties of program and accompanying documentation. In no event shall Clear Creek Solutions, Inc. be liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business information, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear Creek Solutions, Inc. has been advised of the possibility of such damages. Clear Creek Solutions, Inc. 6200 Capitol Blvd. Ste F Olympia, WA. 98501 Toll Free 1(866)943-0304 Local (360)943-0304 www.clearcreeksolutions.com DocuSign Envelope ID: 108D365A-BF86-40BD-88FF-CF3D617C2D47