HomeMy WebLinkAboutP_0_TT T35277 CR Levee 90% Plans 221114PROJECT SITE
LAT:47° 29' 34.12"
LONG:122° 12' 47.07"
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 G-01 COVER SHEET.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEE IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
COVER SHEET
GENERAL NOTES
1.PRIOR TO GRADING, ALL VEGETATION, TRASH, AND DEBRIS SHALL BE REMOVED
FROM ALL AREAS OF CONSTRUCTION.
2.IMPORT SOILS SHALL BE OBSERVED AND EVALUATED BY THE PROJECT
ENGINEER PRIOR TO TRANSPORTING THE SOILS TO THE PROJECT SITE.
3.EXISTING ROCK RIPRAP SHALL BE PROTECTED IN PLACE. REMOVE AND
STOCKPILE INTERFERING PORTION OF EXISTING ROCK RIPRAP BANK
PROTECTION AND REPLACE PER SPECIFICATIONS.
4.PORTIONS OF THE CONSTRUCTION SITE ARE ADJACENT TO OR LOCATED WITHIN
THE RENTON MUNICIPAL AIRPORT. THE CONTRACTOR SHALL COORDINATE WITH
THE RENTON MUNICIPAL AIRPORT WHEN SITE ACCESS REQUIRES TRAVELING
THROUGH THE AIRPORT LIMITS OR WHEN WORKING WITHIN THE AIRPORT LIMITS.
5.EXISTING SIDEWALKS, SHARED USE PATHS, ROADWAYS, FENCES, GATES, GUARD
RAILS, MARKED UTILITIES, AND OTHER EXISTING INFRASTRUCTURE SHALL BE
PROTECTED IN PLACE UNLESS OTHERWISE NOTED.
6.ANY DAMAGE TO THE EXISTING SHARED USE PATHS, SIDEWALKS, ROADWAYS,
UTILITIES, OR OTHER EXISTING INFRASTRUCTURE SHALL BE REPLACED IN KIND
PER CURRENT CITY OF RENTON STANDARDS AT THE CONTRACTOR'S EXPENSE.
7.THE TEMPORARY WORK AREA LIMITS SHALL BE STAKED AND ALL EQUIPMENTS
SHALL BE OPERATED WITHIN THE TEMPORARY WORK AREA LIMITS.
8.THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION AND INVERT
ELEVATIONS OF EXISTING UTILITY PIPES CROSSING UNDER THE EXISTING LEVEE
PRISM PRIOR TO CONSTRUCTION AND REPORT THAT INFORMATION TO THE
PROJECT ENGINEER.
9.PROTECT ALL TREES, BUSHES, SHRUBS, OR OTHER LARGE VEGETATION UNLESS
OTHERWISE NOTED.
10.CONTRACTOR SHALL VERIFY THE LOCATION OF TREES, BUSHES, SHRUBS, OR
OTHER LARGE VEGETATION PRIOR TO BEGINNING EXCAVATION/GRADING
ACTIVITIES IN AREAS ADJACENT TO TREES OR LANDSCAPING AREAS.
11.NO CONSTRUCTION EQUIPMENT SHALL CROSS THE EXISTING PUBLIC ACCESS
PATH WITHOUT A GROUND GUIDE.
12.NO WORK SHALL OCCUR WITHIN THE ORDINARY HIGH WATER. SHOULD
CHANGING CONSTRUCTION CONDITIONS REQUIRE WORK WITHIN THE ORDINARY
HIGH WATER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE
NECESSARY PERMITS PRIOR TO SUCH WORK OCCURING.
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 G-02 GENERAL NOTES.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
GENERAL NOTES
AGENCY DEPARTMENT/UTILITY CONTACT PHONE EMAIL
PSE GAS JEFF KIESZ 206.348.2347 Jeffrey.Kiesz@pse.com
BOEING 1ST SHIFT PLUMBER LEAD (6:00AM - 2:00PM)KYLE GROBLER 253.273.8727 kyle.e.grobler@boeing.com
BOEING 2ND SHIFT PLUMBER (2:00PM - 10:00PM)MIKE HANSOW 425.336.9183 michael.h.hansow@boeing.com
BOEING BOEING INFRASTRUCTURE MANAGER GABE BERG 206.495.7773
BOEING MECHANICAL ENGINEER JOHN TAYLOR 206.245.9301 john.taylor20@boeing.com
BOEING MECHANICAL ENGINEER THOMAS KAJOR 253.241.2072 thomas.p.kajor@boeing.com
BOEING DISPATCH (IF UNABLE TO REACH STAFF)206.544.6500
BOEING EMERGENCY HOTLINE 206.655.2222
KING COUNTY WASTEWATER MARK LAMPARD 206.477.5414 Ipa.team@kingcounty.gov
COR WATER ABDOUL GAFOUR 425.430.7210 Agafour@Rentonwa.gov
COR WASTEWATER JOE STOWELL 425.430.7212 jstowell@Rentonwa.gov
COR SURFACE WATER CHESTER BENNETT 425.430.7205 CBennett@Rentonwa.gov
COR AIRPORT WILLIAM ADAMS 425.430.7473 wadams@rentonwa.gov
COR TRANSPORTATION BOB HANSON 425.430.7223 bhanson@rentonwa.gov
UTILITIES AND CITY OF RENTON CONTACT LIST
EROSION AND SEDIMENT CONTROL (ESC)
STANDARD PLAN NOTES
1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY
OCCURS, A PRE-CONSTRUCTION MEETING SHALL BE HELD AMONG
THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE
APPLICANT, AND THE APPLICANT'S CONTRACTOR.
2.THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE
WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY)
CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS
REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE
THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO
ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER
GENERAL PERMIT.
3.THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION
SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE
FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO
POST-PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC
REQUIREMENTS.
4.THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND
THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND
TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE
CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD
IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON
SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE
START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD,
NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE
PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE
APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
5.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT
THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE
DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS
CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE
REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN
AND TRACK-OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR
THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED
OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE
END OF EACH DAY, OR MORE FREQUENTLY DURING WET
WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM
ENTERING WATERS OF THE STATE.
6.WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED
OFF-SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY.
DO NOT WASH OUR CONCRETE TRUCKS ONTO THE GROUND, OR
TO STORM DRAINS OR OPEN DITCHES. ON-SITE DUMPING OF
EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED
CONCRETE WASHOUT AREAS.
7.ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN
OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO
PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER,
DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES. ALL ESC BMPS
SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH
TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND
POTENTIAL FOR ON-SITE EROSION HAS PASSED. ALL ESC BMPS
SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND
THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR
ON-SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION,
MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF
ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8.ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE
THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF
PROPERLY.
9.THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE
MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS.
AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR
SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL
ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO
ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE.
DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE
OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS
ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES
AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE
MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT
ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING
DRAINAGE SYSTEM.
10.APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT
CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE,
NOR LOCATION OF PIPES, RESTRICTIONS, CHANNELS, OR
STORMWATER FACILITIES.
11.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION
OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY
FOR REVIEW AND APPROVAL.
12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY
EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS
DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH)
OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH
SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE
APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING,
PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF
THE RENTON SWDM.
13.WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION
SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS
OTHERWISE APPROVED BY THE CITY.
14.ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING
IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7)
DAYS.
15.THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND
MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24
HOURS FOLLOWING A STORM EVENT. INSPECTION AND
MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED
BY THE CITY.
16.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY,
CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30
SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE
AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA,
UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED
TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL
BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO
ENSURE FULLY FUNCTIONING CONDITION.
17.AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE
CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND
CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE
CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN
WATER INTO THE DOWNSTREAM SYSTEM.
18.ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A
TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE
NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE
CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY
FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE,
THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT
THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE
FINAL GRADE OF THE PERMANENT FACILITY.
19.AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING
STORMWATER FACILITIES OR ON-SITE BMPS (AMENDED SOILS,
BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY
FENCED AND PROTECTED USING ESC BMPS TO AVOID
SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20.PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST),
ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH
ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE
WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED
WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN
EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE
AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY
FOR REVIEW.
21.PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE
SHALL BE STABILIZED TO PREVENT SEDIMENT-LADEN WATER FROM
LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED,
AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND
ON-SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING
CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL
BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A
MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND
MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP
SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS
ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER
1ST.
22.ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK
STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE
CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN
CITY ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN
ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF
ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE INTERNATIONAL BUILDING CODE.
RECOMMENDED CONSTRUCTION SEQUENCE
1.PRE-CONSTRUCTION MEETING.
2.POST SIGN WITH NAME AND PHONE NUMBER OF CSWPP/ESC SUPERVISOR (MAY BE
CONSOLIDATION WITH THE REQUIRED NOTICE OF A CONSTRUCTION SIGN).
3.FLAG OR FENCE CLEARING LIMITS.
4.INSTALL CATCH BASIN PROTECTION AND STORMWATER BMP AREA PROTECTION AS REQUIRED.
5.GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
6.INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
7.CONSTRUCT SEDIMENT PONDS AND TRAPS.
8.GRADE AND STABILIZE CONSTRUCTION ROADS.
9.CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.)
SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. CONSTRUCT
SWPPS CONTROLS IN ANTICIPATION OF SCHEDULED CONSTRUCTION ACTIVITY (E.G.,
CONCRETE-RELATED pH MEASURES FOR UTILITY, VAULT, OR ROADWAY CONSTRUCTION).
10.MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE CITY OF
RENTON SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS.
11.RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE
CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL AND POLLUTION PREVENTION IS
ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS.
12.COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY
SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH,
COMPOST, OR EQUIVALENT.
13.STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
14.SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
15.UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS
REMOVED IF APPROPRIATE.
FLOODWALL / FLOODWALL ADDITION
FLOODWALL / FLOODWALL ADDITION
(PROFILE AND SECTION VIEW)
ORDINARY HIGH WATER
100-YEAR WSE
MINIMUM FREEBOARD
TEST HOLE LOCATIONS
EMBANKMENT FILL
EMBANKMENT OVERBUILD
EXCAVATION LIMITS
SHORING
FULL DEPTH ROAD REPLACEMENT
REPLACED PAVEMENT
(SECTION VIEW)
CONCRETE SIDEWALK
CRUSHED SURFACING
BASE COURSE
GRADE BREAK
PROTECT EXISTING TREE
CONCRETE CURB WALL
CUT LINE
FILL LINE
CRUSHED SURFACING TOP COURSE
GRAVEL BACKFILL
OHW
C
F
FOUND MONUMENT (AS NOTED)
FOUND REBAR (AS NOTED)
CALCULATED MONUMENT
SET STAKE
MEASURED DISTANCE
CALCULATED DISTANCE
PLAT DISTANCE
SANITARY SEWER MANHOLE
YARD DRAIN
CATCH BASIN (CB)
STORM DRAIN MANHOLE
STORM DRAIN CLEANOUT
WATER VALVE
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION
IRRIGATION CONTROL VALVE
CONCRETE VALVE MARKER
WATER METER
HOSE BIB
POST-INDICATOR VALVE
GAS VALVE
GAS METER
ELECTRIC HANDHOLE
ELECTRIC JUNCTION BOX
ELECTRIC METER
UTILITY POLE WITH LIGHT
YARD LIGHT
UTILITY POLE
STREET LIGHT VAULT
GUY ANCHOR
BOLLARD
SIGN - WOODEN POST
SIGN - METAL POST
WETLAND FLAG
MONITORING WELL
BORE HOLE
CONIFEROUS TREE
DECIDUOUS TREE
SPECIAL EXCEPTION (#)
OVERHEAD POWER
WHEELCHAIR RAMP
CONCRETE
CONCRETE CURB EXTRUDED
CONCRETE CURB
EXISTING
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 G-03 LEGEND, SYMBOLS AND ABBREVIATIONS.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
INVERT ELEVATION
CONCRETE PIPE
CHAINLINK FENCE
WOOD FENCE
SANITARY SEWER MANHOLE
STORM DRAIN LINE
SANITARY SEWER LINE
RIGHT OF WAY
FENCE
ROCKERY
CENTERLINE
RIGHT OF WAY
PLAT LOT LINE
PROPERTY LINE
EXISTING PAVEMENT (SECTION VIEW)
EXISTING FLOODWALL
EXISTING GAS LINE
EXISTING WATER LINE
TELECOMMUNICATIONS LINE
SD
SS
X
APPROX
AVE
B/FTG
BMP
C
CB
CL
CONC
CONST
CONT
COR
CSBC
CSTC
CSWPP
DESC
DIA
E
EG
EL
EX / EXST
F
FG
GAL
HMA
H / HORIZ
HPW
IE
L
LB
LF
MAX
MIN
MSE
N
NTS
O.C.
O.D.
OHW
PC
PG
PSE
PT
R
RB
RCP
ROW
RT
S
SD
SF
SP
SPEC
SS
STA
STD
SWPPP
T/C
T/FTG
T/W
TESC
TYP
USACE
V / VERT
W/
W
WSDOT
WSE
APPROXIMATELY
AVENUE
BOTTOM OF FOOTING
BEST MANAGEMENT PRACTICE
CELSIUS
CATCH BASIN
CENTERLINE / CLASS
CONCRETE
CONSTRUCTION
CONTINUED
CITY OF RENTON
CRUSHED SURFACING BASE COURSE
CRUSHED SURFACING TOP COURSE
CONSTRUCTION STORMWATER POLLUTION PREVENTION
DESCRIPTION
DIAMETER
EAST
EXISTING GROUND
ELEVATION
EXISTING
FAHRENHEIT
FINISHED GRADE
GALLON
HOT MIX ASPHALT
HORIZONTAL
HIGH PRESSURE WATER
INVERT ELEVATION
LEFT
LEFT BANK
LINEAR FEET
MAXIMUM
MINIMUM
MECHANICALLY STABILIZED EARTH
NORTH
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
ORDINARY HIGH WATER
POINT OF CURVATURE
PAVEMENT GRADE
PUGET SOUND ENERGY
POINT OF TANGENCY
RIGHT
RIGHT BANK
REINFORCED CONCRETE PIPE
RIGHT OF WAY
RIGHT TANGENT
SOUTH
STORM DRAIN
SQUARE FEET
STOCKPILE
SPECIFICATION
SANITARY SEWER
STATION
STANDARD
STORMWATER POLLUTION PREVENTION PLAN
TOP OF CURB
TOP OF FOOTING
TOP OF WALL
TEMPORARY EROSION AND SEDIMENT CONTROL
TYPICAL
UNITED STATES ARMY CORPS OF ENGINEERS
VERTICAL
WITH
WATER / WEST
WASHINGTON STATE DEPARTMENT OF TRANSPORTATION
WATER SURFACE ELEVATION
ABBREVIATIONS
PROPOSED
LEGEND
LEGEND, SYMBOLS AND ABBREVIATIONS
TOPSOIL STRIPPING
RIP RAP REMOVAL AREA
SILT FENCE
STRAW WATTLES
HIGH VISIBILITY FENCE
SAWCUT
INLET PROTECTION
REMOVE SHRUB
REMOVE TREE
REMOVE EXISTING FLOODWALL
CLEAR AND GRUB LIMITS
REMOVE EXISTING FEATURE
TEMPORARY CONSTRUCTION FENCE
PAVEMENT REMOVAL
SF
TESC LEGEND
HVF
C&G
GAS
W
T
TOPSOIL HATCH
100' FROM NORTH BOEING BRIDGE
PUBLIC ROW
RIGHT BANK USACE ALIGNMENT
NORTH BOEING BRIDGESEE SHEETS C-101
AND TEC-01CEDAR RIVER
LEFT BANK USACE ALIGNMENTRENTON MUNICIPAL AIRPORT
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00
10+0
0
11+0
0
12+00 13+00
14+00 15+00 16+00 17+00 18+00 19+00
20+00
21+00 22+00
23+00 24+00
25+00 26+00 27+00 28+00
29+00 30+00
31+00 32+00
CONTROL POINT 1686 CONTROL POINT 1687
100' FROM SOUTH BOEING BRIDGEBOEING RENTON FACILITY
RENTON MUNICIPAL AIRPORT
RENTON MEMORIAL STADIUM
RIGHT BANK USACE ALIGNMENT
SEE SHEETS C-109
AND TEC-04
SEE SHEETS C-102
AND TEC-02
CEDAR RIVER
SEE SHEETS C-103
AND TEC-02
LEFT BANK USACE ALIGNMENT
22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00
30+00 31+00 32+00 33+00 34+00 35+00
36+00 37+00
38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 46+00
SOUTH BOEING BRIDGE32+00 33+00
34+0
0 35+00 36+00
37+00
38+00
39+00 40+00 41+00 42+00
43+00
44+00 45+00
46+00 47+00 48+00 49+00 50+00 51+00 52+00
53+00
54+00 55+00 56+00
EXISTING 12" CITY WATER LINE
CROSSING UNDER CEDAR RIVER
OERIGHT BANK USACE ALIGNMENT
LEFT BANK USACE ALIGNMENT
RENTON SENIOR ACTIVITY CENTER
LOGAN
AVENUE
BR
IDGE
SEE SHEETS C-112
AND TEC-05
SEE SHEETS C-105
AND TEC-03
SEE SHEETS C-107
AND TEC-03
CEDAR RIVER
CEDA
R
R
I
V
E
R
RIGHT RIVER BANK
100' FROM LOGAN
AVENUE BRIDGE
LEFT RIVER BANK
47+
0
0
48+00
49+00
50+0
0
51+0
0
52+00 53+00 54+00 55+00 56+00
57+00
58+00 59+00
60
+
0
0 61+0062+00
63+00
63+94.85
56+00
57+
0
0
58+00
59+00
60+00 61+00
62+00
63+00
64+00
65+00
66+00
67+00 68+00
68+84.19
2-12" BOEING HIGH PRESSURE
WATER LINES
SEE SHEETS C-110
AND TEC-04
CONTROL POINT 301
CONTROL POINT 302
CONTROL POINT 3667
SEE SHEETS C-111
AND TEC-04
100' FROM LOGAN
AVENUE BRIDGE
100' FROM LOGAN
AVENUE BRIDGE
100' FROM LOGAN
AVENUE BRIDGE
SURVEY CONTROL TABLE
PT#
300
3667
NORTHING
178057.70
180338.67
EASTING
1302312.06
1300258.90
ELEVATION
112.41
40.16
DESCRIPTION
GP17405-66
3 1/2" BRASS DISK, IN CONCRETE SIDEWALK
AT THE SR-405 - RENTON AVE. UNDERCROSSING
(NOT SHOWN ON PLANS)
GP17405-66
3 1/2" BRASS DISK, IN CONCRETE SIDEWALK
AT THE SR-405 - RENTON AVE. UNDERCROSSING
(NOT SHOWN ON PLANS)
COR BM 2120
2 1/2" BRASS DISK IN CONCRETE GUARDRAIL
AT LOGAN AVENUE BRIDGE
GP17405-66
3 1/2" BRASS DISK, IN CONCRETE SIDEWALK
AT THE SR-405 - RENTON AVE. UNDERCROSSING
(NOT SHOWN ON PLANS)NNNMATCHLINE STATION 32+00RIGHT BANK USACE ALIGNMENTMATCHLINE STATION 56+00RIGHT BANK USACE ALIGNMENTMATCHLINE STATION 56+00RIGHT BANK USACE ALIGNMENTMATCHLINE STATION 32+00RIGHT BANK USACE ALIGNMENT0
SCALE:
50'100'200'
1'' = 100'
AND SURVEY CONTROL
OVERALL SITE PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 C-01 OVERALL SITE PLAN - USACE.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
BOEING RENTON PLANT NOTE
1.USACE STATIONING BASED ON "LOWER CEDAR RIVER FLOOD CONTROL:
LEVEES AND FLOODWALLS" PREPARED BY THE US ARMY CORPS OF
ENGINEERS, SEATTLE DISTRICT DATED DECEMBER 03, 1998
SURVEY CONTROL NOTES
1.HORIZONTAL DATUM: NAD 83/11, WASHINGTON STATE PLANE NORTH.
2.VERTICAL DATUM: NAVD 88, WSDOT MONUMENT GP17405-66.
HVFHVFHVFC&GC&GC&GC&GC&G C&G
C&G
SF
SF
SP
19+00
1
2
3
4
5
6
25
25
23
24
24
26
26
27
27
20
18
19
21
22
23
CEDAR RIVER
7
8
100-YEAR FLOOD
EXTENTS
9
SUGGESTED TOPSOIL
STOCKPILE LOCATION
LB STA 18+50 TO 19+50
TESC AND SITE PREPARATION PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 TEC-01 TESC AND SITE PREP PLAN.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
IMPROVE FLOODWALL TO EMBANKMENT TRANSITION
LB STA 18+50 TO 19+50
SCALE: 1" = 10'
KEY NOTES
EXISTING PAVEMENT TO SERVE AS CONSTRUCTION ENTRANCE.
INSTALL SILT FENCE PER CITY OF RENTON STANDARD PLAN 214.00 ON RIVER SIDE OF
EXISTING LEVEE, DOWN SLOPE FROM CONSTRUCTION SITE.
INSTALL STRAW WATTLES PER CITY OF RENTON STANDARD PLAN 213.40.
INSTALL HIGH VISIBILITY FENCE PER WSDOT STANDARD PLAN I-10.10-01.
SURROUND WEATHER STATION WIND TOWER WITH HIGH VISIBILITY FENCE (SEE KEY NOTE 4).
PROTECT WEATHER STATION WIND TOWER DURING CONSTRUCTION.
PROTECT EXISTING 3" BRASS DISK.
REMOVE EXISTING RIP RAP AND STOCKPILE FOR REUSE.
STRIP EXISTING TOPSOIL AND STOCKPILE FOR REUSE.
0
SCALE:
5'10'20'
1'' = 10' ON 22x34 SHEETN EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES
SEE SHEET G-02 FOR THE CITY OF RENTON'S ESC STANDARD PLAN NOTES.
CONSTRUCTION CONSTRAINTS
1.ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL PROJECT PERMITS.
2.THIS SITE IS LOCATED WITHIN THE RENTON MUNICIPAL AIRPORT LIMITS. THE CONSTRUCTION
CONTRACTOR SHALL COORDINATE WITH THE RENTON MUNICIPAL AIRPORT WHEN TRAVELING
WITHIN THE AIRPORT LIMITS AND WHEN WORKING WITHIN THE AIRPORT LIMITS.
3.NO TEMPORARY OR PERMANENT ESC BMPS MAY BE PLACED WITHIN THE ORDINARY HIGH
WATER MARK.
4.ROADWAY SHALL NOT BE IMPEDED DURING CONSTRUCTION BY STOCKPILING OR STAGING.
2
3
1
4
5
6
7
8
9
252426272825
23
24
26+00 27+00 28+00
29+0
0
SF SF SF SF SF
SF
SF
1
CEDAR RIVER
100-YEAR FLOOD
EXTENTS
1
3
2
4
5
1
6
3
7
2
25
25
23
23
24
24
26
26
27
27
28
28
29
29
SF SF SF SF SF SF SF SF SF
CEDAR RIVER
100-YEAR FLOOD
EXTENTS
3
2
4
1
5
2
6
4
DESCRIPTIONBEGIN REMOVING AND RESETTING GUARDRAILEND REMOVING AND RESETTING GUARDRAILBEGIN REMOVING AND RESETTING CHAINLINK FENCEEND REMOVING AND RESETTING CHAINLINK FENCEPOINT TABLE
POINT
1
2
3
4
NORTHING
182674.5±
182319.3±
182675.2±
182319.8±
EASTING
1299266.8±
1299355.3±
1299269.3±
1299357.3±
DESCRIPTION
BEGIN REMOVING AND RESETTING GUARDRAIL
END REMOVING AND RESETTING GUARDRAIL
BEGIN REMOVING AND RESETTING CHAINLINK FENCE
END REMOVING AND RESETTING CHAINLINK FENCE
LB STA 26+50 TO 33+50
TESC AND SITE PREPARATION PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 TEC-02 TESC AND SITE PREP PLAN.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
LEVEE EMBANKMENT WITH CURB WALL
LB STA 30+00 TO 33+50
SCALE: 1" = 20'
FLOODWALL ADDITION AND CURB WALL
LB STA 26+50 TO 30+00
SCALE: 1" = 20'
KEY NOTES
EXISTING PAVEMENT TO SERVE AS CONSTRUCTION ENTRANCE.
INSTALL SILT FENCE PER CITY OF RENTON STANDARD PLAN 214.00 ON RIVER SIDE OF
EXISTING LEVEE, DOWN SLOPE FROM CONSTRUCTION SITE. ENSURE SILT FENCE DOES NOT
ENCROACH ON OHW LINE.
INSTALL STRAW WATTLES PER CITY OF RENTON STANDARD PLAN 213.40.
INSTALL INLET PROTECTION PER CITY OF RENTON STANDARD PLAN 216.30 AT ALL INLETS
WITHIN 500 FEET DOWNSTREAM OF THE PROJECT SITE.
REMOVE AND RESET EXISTING GUARDRAIL AT NEAREST JOINT OR POST.
SEE SHEET C-103 FOR GUARDRAIL LOCATION.
REMOVE EXISTING CHAINLINK FENCE AT NEAREST POST.
REMOVE EXISTING BIRD PREVENTION WIRE.
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES
SEE SHEET G-02 FOR THE CITY OF RENTON'S ESC STANDARD PLAN NOTES.
CONSTRUCTION CONSTRAINTS
1.ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL PROJECT PERMITS.
2.THIS SITE IS LOCATED WITHIN THE RENTON MUNICIPAL AIRPORT LIMITS. THE CONSTRUCTION
CONTRACTOR SHALL COORDINATE WITH THE RENTON MUNICIPAL AIRPORT WHEN TRAVELING
WITHIN THE AIRPORT LIMITS AND WHEN WORKING WITHIN THE AIRPORT LIMITS.
3.NO TEMPORARY OR PERMANENT ESC BMPS MAY BE PLACED WITHIN THE ORDINARY HIGH
WATER MARK.
4.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE CEDAR RIVER TRAIL WILL REQUIRE A
RIGHT OF ENTRY PERMIT AND TRAFFIC CONTROL PLAN. CONTRACTOR SHALL MAKE EVERY
EFFORT TO MINIMIZE IMPACTS TO CEDAR RIVER TRAIL AND MAINTAIN PEDESTRIAN TRAFFIC.MATCHLINE SEE BELOWMATCHLINE SEE ABOVE0
SCALE:
10'20'40'
1'' = 20' ON 22x34 SHEET
0
SCALE:
10'20'40'
1'' = 20' ON 22x34 SHEETN
N2
3
1
4
5
6
7
OE
OE
OE
OE
OE
OE
OE
OE
SF SF
SF SF SF
SF
55+00
56+00
57+00
C&G
C&G
C&G
C&G
C&G
C&G
C&G
C&G C&GC&GC&GC&GC&GC&GC&GC&GC&GC&GC&G100-YEAR FLOOD
EXTENTS
30
35313233343637LAKE WASHINGTON LOOP TRAIL
PROJECT LIMITS (PERMIT ###).
IMPROVEMENTS BY OTHERS.
3
6
6
6
8
8 88
9
9
12
13
1
4
5
16
18
19
20
OE OEOESFSFSF
SF
SF
SF
SF
SF
SF
C&GC&GC&GC&G
C&G
C&G
C&G
C&G
C&G
C&G
C&G
C&G
C&GC&GC&GC&GC&GC&GC&GC&GC&GC&GC&G100-YEAR FLOOD
EXTENTS
3
5
3
5
33
3434
36
363532
33
34LS2 TRAIL
SUB SHOP
LOGAN AVE S
14
3
4
5
5
6
17
6
4
7
8
10
13
15
15
16
2
2
12
6
6
6
LB STA 55+40 TO 56+90, 58+00 TO 60+00
TESC AND SITE PREPARATION PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 TEC-03 TESC AND SITE PREP PLAN.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
KEY NOTES
ACCESS SITE VIA EAST PERIMETER ROAD AND EAST PERIMETER DRIVE.
ACCESS SITE VIA "SUB SHOP #8" PARKING LOT AND LOGAN AVE SOUTH.
INSTALL SILT FENCE PER CITY OF RENTON STANDARD PLAN 214.00.
INSTALL STRAW WATTLES PER CITY OF RENTON STANDARD PLAN 213.40.
INSTALL TEMPORARY CONSTRUCTION FENCE (EMERALD CITY STATEWIDE TEMPORARY CHAINLINK FENCE OR
EQUAL).
INSTALL INLET PROTRECTION PER CITY OF RENTON STANDARD PLAN 216.30 AT ALL INLETS WITHIN 500 FEET
DOWNSTREAM OF THE PROJECT SITE.
REMOVE EXISTING SHRUB.
REMOVE EXISTING TREE.
REMOVE EXISTING SIGN AND POST. RETAIN SIGN FOR RELOCATION. SEE SHEET C-105.
REMOVE EXISTING CONCRETE FLOODWALL.
PLACE STRAW WATTLES AROUND EXISTING CATCH BASIN RIM. SEE KEY NOTE 4.
PROTECT EXISTING FLOOD WALL.
PROTECT EXISTING MANHOLE / CATCHBASIN.
PROTECT EXISTING LIGHT.
PROTECT EXISTING SIDEWALK.
STRIP EXISTING TOPSOIL AND STOCKPILE FOR REUSE.
REMOVE EXISTING CATCH BASIN. REMOVE EXISTING PIPES WHERE THEY CONFLICT WITH THE REINFORCED
CONCRETE FLOODWALL TYPE 2 AS SHOWN ON SHEET C-107. PLUG AND ABANDON IN PLACE ELSEWHERE.
REMOVE EXISTING ASPHALT PAVEMENT.
REMOVE EXISTING STOP BAR.
SIGN REMOVED BEFORE CONSTRUCTION. CONTRACTOR TO VERIFY.
1
CONSTRUCTION CONSTRAINTS
1.ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL PROJECT PERMITS.
2.NO TEMPORARY OR PERMANENT ESC BMPS MAY BE PLACED WITHIN THE ORDINARY HIGH WATER MARK.
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES
SEE SHEET G-02 FOR THE CITY OF RENTON'S ESC STANDARD PLAN NOTES.
REPAIR AND RAISE FLOODWALL
LB STA 58+00 TO 60+00
SCALE: 1" = 10'
WIDEN LEVEE EMBANKMENT
LB STA 55+40 TO 56+90
SCALE: 1" = 10'NN
0
SCALE:
5'10'20'
1'' = 10' ON 22x34 SHEET
0
SCALE:
5'10'20'
1'' = 10' ON 22x34 SHEET
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
30
27
28
29
31
3230282931
1
4
6
10
7
12
13
100-YEAR FLOOD
EXTENTS
SOUTH BOEING
BRIDGE
SF
SF SF SF SF SFHVFHVF HVFC&G
C&GC&G
C&G C&G C&G C&G
C&G C&GC&GC&GC&GC&GC&GC&G49+00 50+00
14
11
5
CEDAR RIVER TRAIL
35
35
34
353534 365
2
6
10
7
13
LAKE WASHINGTON LOOP TRAIL
PROJECT LIMITS (PERMIT ###).
IMPROVEMENTS BY OTHERS.
100-YEAR FLOOD
EXTENTS
RENTON MEMORIAL STADIUM PARKING LOT
HVFC&GC&G
C&G
C&G C&GC&G
C&G
C&GC&GC&GC&GC&GC&GC&G64+00 8
14
LOGAN AVE N
15
16
CEDAR RIVER TRAIL
7
OEOEOE403738394138 373
5
6
13
9
100-YEAR FLOOD
EXTENTS C&GC&GC&GC&G13
14LOGAN AVE N17
RB STA 49+30 TO 50+30, 63+00 TO 64+30, 65+50
TESC AND SITE PREPARATION PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 TEC-04 TESC AND SITE PREP PLAN.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RAISE LEVEE EMBANKMENT LANDSCAPING BERM
RB STA 63+30 TO 64+30
SCALE: 1" = 10'
IMPROVE FLOODWALL TO EMBANKMENT TRANSITION
RB STA 49+30 TO 50+30
SCALE: 1" = 10'
KEY NOTES
ACCESS SITE FROM RENTON AIRPORT VIA SOUTH BOEING BRIDGE.
CONSTRUCTION CONTRACTOR SHALL COORDINATE WITH RENTON AIRPORT
AND BOEING FOR ACCESS.
ACCESS SITE VIA STAGING AREA IN EXISTING RENTON MEMORIAL STADIUM
PARKING LOT.
ACCESS SITE VIA EXISTING SIDEWALKS.
INSTALL SILT FENCE PER CITY OF RENTON STANDARD PLAN 214.00.
INSTALL STRAW WATTLES PER CITY OF RENTON STANDARD PLAN 213.40.
INSTALL TEMPORARY CONSTRUCTION FENCE (EMERALD CITY TEMPORARY
CONSTRUCTION FENCE OR EQUAL).
INSTALL INLET PROTECTION PER CITY OF RENTON STANDARD PLAN 216.30 AT
ALL INLETS WITHIN 500 FEET DOWNSTREAM OF THE PROJECT SITE.
REMOVE EXISTING SHRUB.
REMOVE EXISTING TREE PER PROJECT LANDSCAPING PLANS SHEET L-02.
PROTECT EXISTING BENCH. SURROUND THE EXISTING BENCH WITH HIGH
VISIBILITY FENCE PER WSDOT STANDARD PLAN I-10.10-01 TO MARK THE
PROTECTED AREA.
PROTECT EXISTING LIGHT AND ELECTRICAL BOX.
PROTECT EXISTING CONCRETE POCKET WALL.
PROTECT EXISTING ASPHALT/CONCRETE WALK.
STRIP EXISTING TOPSOIL AND STOCKPILE FOR REUSE.
PROTECT EXISTING COMMUNICATIONS.
PROTECT EXISTING CONCRETE CURB.
REMOVE EXISTING CONCRETE PAVEMENT.
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES
SEE SHEET G-02 FOR THE CITY OF RENTON'S ESC STANDARD PLAN NOTES.
CONSTRUCTION CONSTRAINTS
1.ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL PROJECT PERMITS.
2.NO HEAVY MACHINERY SHALL BE DRIVEN ON PUBLIC TRAIL
3.NO TEMPORARY OR PERMANENT ESC BMPS MAY BE PLACED WITHIN THE ORDINARY HIGH
WATER MARK.
4.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE CEDAR RIVER TRAIL WILL REQUIRE A
RIGHT OF ENTRY PERMIT AND TRAFFIC CONTROL PLAN. CONTRACTOR SHALL MAKE EVERY
EFFORT TO MINIMIZE IMPACTS TO CEDAR RIVER TRAIL AND MAINTAIN PEDESTRIAN
TRAFFIC.
REMOVE AND REPLACE SIDEWALK AREA
RB STA 65+50
SCALE: 1" = 10'
0
SCALE:
5'10'20'
1'' = 10' ON 22X34 SHEETN
NN
0
SCALE:
5'10'20'
1'' = 10' ON 22X34 SHEET
0
SCALE:
5'10'20'
1'' = 10' ON 22X34 SHEET
9
10
11
12
13
14
15
16
17
2
3
1
4
5
6
7
8
HVF HVFHVF HVF HVF HVF HVF HVF HVFHVFHVFHVFHVFC&G C&GC&G C&G C&G C&G C&G C&G
C&GC&GC&G
C&G C&G C&G C&G
C&GC&G
3
6
6
2
4
5
7
8
9
4
100-YEAR FLOOD
EXTENTS
(2 TREES)40363
7
3839414235
35
3233
343636
37
373534
2
10
RENTON SENIOR ACTIVITY CENTER
11
RB STA 65+90 TO 68+50
TESC AND SITE PREPARATION PLAN
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 TEC-05 TESC AND SITE PREP PLAN.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RAISE LEVEE EMBANKMENT WITH FLOODWALL
RB STA 65+90 TO 68+50
SCALE: 1" = 10'
KEY NOTES
ACCESS SITE FROM THE RENTON MEMORIAL STADIUM PARKING LOT.
INSTALL STRAW WATTLES PER CITY OF RENTON STANDARD PLAN 213.40.
INSTALL HIGH VISIBILITY FENCE PER WSDOT STANDARD PLAN I-10.10-01.
INSTALL INLET PROTECTION PER CITY OF RENTON STANDARD PLAN 216.30 AT ALL INLETS WITHIN 500 FEET
DOWNSTREAM OF THE PROJECT SITE.
REMOVE EXISTING HEDGE.
REMOVE EXISTING TREE.
REMOVE EXISTING FLAGPOLE, PLAQUE, AND FOUNDATION.
RETAIN FLAGPOLE AND PLAQUE FOR RESETTING. SEE SHEET C-114
PROTECT EXISTING BUILDING AND FOUNDATION.
PROTECT EXISTING CONCRETE WALK.
STRIP EXISTING TOPSOIL AND STOCKPILE FOR REUSE.
PROTECT EXISTING STORM, ROOF DRAIN, AND IRRIGATION LINES.
2
3
1
CONSTRUCTION CONSTRAINTS
1.ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL PROJECT PERMITS.
2.NO TEMPORARY OR PERMANENT ESC BMPS MAY BE PLACED WITHIN THE ORDINARY HIGH WATER MARK.
3.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE CEDAR RIVER TRAIL WILL REQUIRE A RIGHT OF ENTRY
PERMIT AND TRAFFIC CONTROL PLAN. CONTRACTOR SHALL MAKE EVERY EFFORT TO MINIMIZE IMPACTS TO CEDAR
RIVER TRAIL AND MAINTAIN PEDESTRIAN TRAFFIC.
4
5
6
7
8
9
0
SCALE:
5'10'20'
1'' = 10' ON 22X34 SHEETN EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES
SEE SHEET G-02 FOR THE CITY OF RENTON'S ESC STANDARD PLAN NOTES.
10
11
15
20
25
30
15
20
25
30
0+00 0+20 0+40 0+60 0+80 1+00
EXCAVATION
LIMIT
BOTTOM OF
FLOODWALL
FOOTING KEY
EG 27.0'±
T/W 27.1' MIN
TOP OF LEVEE EMBANKMENT FILL 27.1' MIN EXST T/W 27.1'±
8
EXST GROUND
ALONG LANDWARD
TOE OF WALL
2
4
54
3
13
2' FREEBOARD
100 YEAR WSE
1
12
FLOODWALL
T/FTG
FLOODWALL
B/FTG
2H:1V
5H:1V
1.5H:1V
1.5H:1V
5
20
18
19
21
22
23
24
27
26
24
23
25
25
25
25
2
3
CEDAR RIVER
0+00 0+20 0+40
0+60
0+80 1+001+00.01
X X X
18+60 18+80 19+00 19+20 19+40 19+60
C C
C
F
F FRENTON MUNICIPAL AIRPORT
LIMIT OF EXCAVATION
100-YEAR FLOOD EXTENTS
ROTATED ARM EL 29.5'
26± LF FLOODWALL
EXST USACE
LEFT BANK ALIGNMENT
TOP OF
EMBANKMENT
2
3
4
BEGIN CONSTRUCTION
STA 18+50.00
END CONSTRUCTION
STA 19+50.00
1
3
2
4
5
6
6
7
B
-A
-
10
12
11
14
CONSTRUCTION
ALIGNMENT ALONG
LANDWARD EDGE OF
EMBANKMENT AND
LANDWARD FACE OF
WALL
5
7
8
9
MATCH EXST
EL 27.00'
MATCH EXST
EL 27.15'
8
COORDINATE TABLE
POINT
1
2
3
4
5
6
7
8
9
NORTHING
183747.24
183715.76
183708.71
183701.93
183680.30
183652.85
183719.33
183677.58
183676.95
EASTING
1299006.87
1299014.61
1299026.81
1299018.15
1299032.20
1299040.54
1299028.24
1299037.97
1299035.19
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN EMBANKMENT (LANDWARD EDGE OF EMBANKMENT)
BEGIN EMBANKMENT (RIVERWARD EDGE OF EMBANKMENT)
BEGIN NEW FLOODWALL (LANDWARD FACE OF WALL)
END NEW FLOODWALL (LANDWARD FACE OF WALL) / BEGIN EXST
END CONSTRUCTION
BEGIN AIRPORT SECURITY FENCE
ANGLE POINT OF AIRPORT SECURITY FENCE
END AIRPORT SECURITY FENCE
OHW OHW
15
20
25
30
35
15
20
25
30
35
0 5 10 15 200-5-10-15-20
1.5
1
FLOODWALL FOOTING KEY
EXCAVATION LIMIT
100 YEAR WSE
2' FREEBOARD
EXST GROUND
TOP OF LEVEE EMBANKMENT FILL
5
WIDTH VARIES
0.0' - 10.0'
FINISHED GRADE
9
2%
1.5
1
GRADE TO EXST
GROUND AT MAX 2H:1V
NEAT LINE EXCAVATION AROUND KEY
1'1'
14
MATCH
EXST
12
15
20
25
30
35
15
20
25
30
35
0 5 10 15 200-5-10-15-20
APPROXIMATE LOCATION
OF WEATHER STATION ARM
1.5
1
FLOODWALL FOOTING KEY
EXCAVATION LIMIT
100 YEAR WSE
2' FREEBOARD
EXST GROUND
FINISHED GRADE
5
2
4.9'±
WIDTH VARIES
0.0' - 10.0'
OHW OHW
5.9'±
FINISHED GRADE
9
2%
11
GRADE TO EXST
GROUND AT MAX 2H:1V
NEAT LINE EXCAVATION
AROUND KEY
1'
14
MATCH
EXST
12
CONSTRUCTION NOTES
1.LOCATION OF EXISTING EMBEDDED FLOODWALL AND EXISTING STEEL SHEET PILE WALL
ARE APPROXIMATE. PROTECT IN PLACE.
2.PROVIDE TEMPORARY PROTECTION FOR WEATHER STATION DURING CONSTRUCTION.
SEE CONTRACT SPECIFICATION SECTION 8-27.
3.PROTECT EXISTING FLOODWALL.
4.MATCH EXISTING FLOODWALL TOP ELEVATION.
5.LEVEE EMBANKMENT FILL SHALL BE IN ACCORDANCE WITH CONTRACT SPECIFICATION
SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS
THIS SPECIFICATION.
6.PROTECT EXISTING 3" BRASS DISK DURING CONSTRUCTION.
7.TOP OF LEVEE EMBANKMENT WIDTH SHALL BE 10' MINIMUM AT NORTHERN END OF
FLOODWALL.
8.EMBED FLOODWALL 5' MINIMUM INTO EMBANKMENT AT TRANSITION.
9.REINFORCED CONCRETE FLOODWALL TYPE 1 PER DETAIL 1, THIS SHEET.
10.REPLACE STOCKPILED RIPRAP DISTURBED DURING CONSTRUCTION ON RIVERWARD
SLOPE.
11.SHORE EXCAVATION WHEN IN THE VICINITY OF THE WEATHER STATION.
12.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B) AS SHOWN ON
SHEETS L-08 AND L-10.
13.JOIN NEW FLOODWALL STEM TO EXISTING FLOODWALL WITH WATERSTOP. SEE DETAIL 2,
THIS SHEET.
14.INSTALL AIRPORT SECURITY FENCE (BY OTHERS).
1
2
3
4
5
8
6
7
9
10
11
12
13
14
1'-3"3'-6"1'-3"1'-0"1'-6"3'-9"
4'-0"
5'-3"2'-0"3"2"#5@12" O.C. EACH
WAY, EACH FACE
#5@12" O.C. EACH WAY, EACH FACE #5 TIE @ 12" O.C.
2-#5 BARS
FINISHED GRADE
0
SCALE:
5'10'20'
1'' = 10' ON 22X34 SHEET
FLOODWALL PLAN
SCALE: 1" = 10'
FLOODWALL PROFILE
SCALE: HORIZ: 1" = 10', VERT: 1" = 2'NLB STA 18+50 TO 19+50
IMPROVE FLOODWALL TO EMBANKMENT TRANSITION
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 C-101 IMPROVE FLOODWALL TO EMBANKMENT TRANSITION.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
KEY MAP
SCALE: 1" = 1000'
N
PLAN AND PROFILE
SITE LOCATION
FLOODWALL SECTIONA
_SCALE: HORIZ: 1" = 5', VERT: 1" = 5'
FLOODWALL SECTIONB
_SCALE: HORIZ: 1" = 5', VERT: 1" = 5'
REINFORCED CONCRETE FLOODWALL TYPE 1 DETAIL
SCALE: NTS1
FLEXIBLE JOINT SEALANT
COMPRESSIBLE
BACKER
SEALANT DEPTHSEE NOTE 3.0 AFLEXIBLE JOINT SEALANT NOTES:
1.0 FLEXIBLE JOINT SEALANT:
A.FLEXIBLE JOINT SEALANT SHALL BE SIKAFLEX-2C NS, OR APPROVED EQUAL.
B.JOINT SEALANT MATERIAL SHALL BE A GUNNABLE OR CAULKABLE MATERIAL
MEETING THE REQUIREMENTS OF ASTM C 920, TYPE S (SINGLE COMPONENT) OR
TYPE M (MULTICOMPONENT). GRADE NS (A NON-SAP OR GUNNABLE SEALANT THAT
PERMITS APPLICATION IN JOINTS ON VERTICAL SURFACES WITHOUT SAGGING OR
SLUMPING WHEN APPLIED AT TEMPERATURES BETWEEN 4.4 AND 50°C (40 AND
122°F))
2.0 JOINT SURFACE PREPARATION:
A.JOINT SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
B.ALL JOINT WALL SURFACES MUST BE CLEAN, SOUND, AND FROST-FREE. JOINT
WALLS MUST BE FREE OF OLD SEALANT, OILS, GREASE, CURING COMPOUND
RESIDUES, AND ANY OTHER FOREIGN MATTER THAT MIGHT PREVENT BOND.
SUBSTRATE SHALL BE CLEANED BY MECHANICAL MEANS.
C.PLANT MATERIAL SHALL BE REMOVED FROM JOINT AND REMOVED FROM ADJACENT
AREAS TO PREVENT FUTURE GROWTH FROM ENTERING THE JOINT.
D.SIKAFLEX 429 PRIMER SHALL BE APPLIED TO THE JOINTS AFTER CLEANING, PRIOR
TO FLEXIBLE JOINT SEALANT APPLICATION, ACCORDING TO THE MANUFACTURER'S
WRITTEN INSTRUCTIONS, INCLUDING HEALTH AND SAFETY RECOMMENDATIONS.
FLEXIBLE JOINT SEALANT NOTES (CONT.)
3.0 FLEXIBLE JOINT SEALANT APPLICATION:
A.FINISHED DEPTH OF SEALANT SHALL BE ½ OF THE JOINT WIDTH, BUT NOT LESS THAN
¼ INCH OR GREATER THAN ½ INCH. DEPTH SHALL BE MEASURED FROM INSIDE OF
CHAMFERED EDGE TO OUTSIDE FACE OF BACKER MATERIAL.
B.BACKER SHALL BE INSTALLED IN BOTTOM OF JOINT TO ACHIEVE THE REQUIRED
SEALANT DEPTH. BACKER MATERIAL SHALL BE COMPRESSIBLE TO ALLOW
UNRESTRICTED MOVEMENT OF THE JOINT AND COMPATIBLE WITH THE SEALANT.
C.JOINT SEALANT APPLICATION SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
D.APPLICATION SHALL OCCUR IN TEMPERATURES BETWEEN 40° F AND 100°F.
E.SEALANT SHALL ONLY BE APPLIED TO CLEAN, SOUND, DRY, AND FROST-FREE
SUBSTRATES.
F.AVOID OVERLAPPING OF SEALANT AS OVERLAPS MAY ENTRAP AIR IN THE JOINT.
G.TOOL SEALANT TO ENSURE FULL CONTACT WITH JOINT WALLS AND REMOVE AIR
ENTRAPMENT.
EXST FLOODWALL
NEW FLOODWALL
COMPRESSIBLE BACKER
FLEXIBLE JOINT SEALANT
WATERSTOP
WALL CONNECTION DETAIL
SCALE: NTS2
WATERSTOP NOTES:
1.WATERSTOP SHALL BE A JP320L RETROFIT
EXPANSION JOINT L-SHAPED THERMOPLASTIC
WATERSHOP AS MANUFACTURED BY J P
SPECIALTIES, INC. (OR APPROVED EQUAL).
INSTALL PER MANUFACTURER SPECIFICATIONS.
1
1
15
20
25
30
35
15
20
25
30
35
0+00 1+00 2+00 3+00 3+50
BOTTOM OF CURB WALL
/ EXCAVATION LIMIT
T/W 29.0' MIN
EXST T/W 28.5'±
EG 28.2'±
T/W 28.7'±
EXST T/W 28.2'±
2
xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx
xx
xx
xx
xx
4
TOP OF FLOODWALL
FINISHED GRADE TOP OF FENCE
TOP OF BARBED WIRE
9
9
EXST GROUND ALONG
LANDWARD TOE OF WALL
2
STA 0+15.0±
8" EXST SD CROSSING
IE 18.86'
1
EXST FLOODWALL
100 YEAR WSE
2' FREEBOARD
FREEBOARD
T/W = 28.9' MIN 3
252426272820
2525
22
23
24
26
27 282323
22
21
CEDAR RIVER
X X
0+00 1+00 2+00
3+00
o o o o o o o o o o oEXST USACE
LEFT BANK ALIGNMENT
1
2
3
1
2
3
100-YEAR FLOOD EXTENTS
25
EXCAVATION LIMITS
5
25
2324
26 27
28
68
7
9
CONSTRUCTION ALIGNMENT
ALONG CENTERLINE OF WALL
10
26+00 27+00 28+00
29+0
0
30+00
BEGIN CONSTRUCTION
STA 26+50.00
4 8
STA 2+18.09
STA 3+09.78
CONSTRUCTION NOTES1.FLOODWALL RAISE PER DETAIL 1, C-104.2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.3.REMOVE EXISTING BIRD PREVENTION WIRE ALONG LENGTH OFFLOODWALL RAISE. SEE SHEET TEC-02.4.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACTSPECIFICATION SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BESUBSTITUTED PROVIDED IT MEETS THIS SPECIFICATION.5.PROTECT EXISTING CATCH BASIN.6.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.7.REMOVE AND RESET BEAM GUARDRAIL FOR FULL LENGTH OFREINFORCED CONCRETE CURB WALL. THE FACE OF GUARDRAIL SHALLBE FLUSH WITH THE FACE OF THE REINFORCED CONCRETE CURB WALL.8.INSTALL BEAM GUARDRAIL ANCHOR TYPE 10 PER WSDOT STANDARDPLAN C-23.60-04.9.WHERE FLOODWALL TOP IS LESS THAN 6' ABOVE EXISTING GROUND,BOLT AIRPORT SECURITY FENCE TO TOP OF FLOODWALL. ADJUST FENCEHEIGHT SO THAT THE TOP OF FENCE IS 6' ABOVE ADJACENT GRADE. (BYOTHERS).CONSTRUCTION NOTES1.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACT SPECIFICATIONSECTION 2-03. NATIVE MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THISSPECIFICATION.2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.3.REMOVE AND RESET BEAM GUARDRAIL IN ORIGINAL ALIGNMENT FOR FULL LENGTHOF CONCRETE CURB WALL. THE FACE OF THE GUARDRAIL SHALL BE FLUSH WITHTHE FACE OF THE CONCRETE CURB WALL.4.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.5.PROTECT EXISTING CARSONITE MARKER.
COORDINATE TABLE
POINT
1
2
3
4
8
10
NORTHING
182976.76
182970.67
182770.46
182678.96
182674.37
182688.09
EASTING
1299221.18
1299222.67
1299271.51
1299265.53
1299266.06
1299266.06
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN FLOODWALL RAISE (WALL CENTERLINE). BEGIN SECURITY FENCE.
ANGLE POINT (WALL CENTERLINE)
END FLOODWALL RAISE, BEGIN NEW CONCRETE CURB WALL (WALL CENTERLINE)
BEGIN GUARDRAIL
SECURITY FENCE ANGLE POINT. TRANSITION SECURITY FENCE OFF OF FLOOD WALL.
CONSTRUCTION NOTES
1.FLOODWALL RAISE PER DETAIL 1, C-104.
2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.
3.REMOVE EXISTING BIRD PREVENTION WIRE ALONG LENGTH OF
FLOODWALL RAISE. SEE SHEET TEC-02.
4.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACT
SPECIFICATION SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BE
SUBSTITUTED PROVIDED IT MEETS THIS SPECIFICATION.
5.PROTECT EXISTING CATCH BASIN.
6.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.
7.REMOVE AND RESET BEAM GUARDRAIL FOR FULL LENGTH OF
REINFORCED CONCRETE CURB WALL. THE FACE OF GUARDRAIL SHALL
BE FLUSH WITH THE FACE OF THE REINFORCED CONCRETE CURB WALL.
8.INSTALL BEAM GUARDRAIL ANCHOR TYPE 10 PER WSDOT STANDARD
PLAN C-23.60-04.
9.WHERE FLOODWALL TOP IS LESS THAN 6' ABOVE EXISTING GROUND,
BOLT AIRPORT SECURITY FENCE TO TOP OF FLOODWALL. ADJUST FENCE
HEIGHT SO THAT THE TOP OF FENCE IS 6' ABOVE ADJACENT GRADE. (BY
OTHERS).
1
2
3
4
5
6
7
8
9
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 C-102 RAISE FLOODWALL AND EMBANKMENT.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
33
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
0
SCALE:
10'20'40'
1'' = 20' ON 22X34 SHEET
FLOODWALL RAISE PLAN
SCALE: 1" = 20'
FLOODWALL RAISE PROFILE
SCALE: HORIZ: 1" = 20' VERT: 1" = 4'NKEY MAP
SCALE: 1" = 1000'
N
SITE LOCATIONMATCHLINE - STATION 3+50SEE SHEET C-103LB STA 26+50 TO 30+00
FLOODWALL RAISE AND CURB WALL
PLAN AND PROFILEMATCHLINE - STATION 3+50SEE SHEET C-103
20
25
30
35
20
25
30
35
3+50 4+00 5+00 6+00 7+007+00
TOP OF CURB WALL
6
BOTTOM OF CURB WALL
/ EXCAVATION LIMIT
2' FREEBOARD
100 YEAR WSE
T/W 29.8' MIN
EG 28.9'±
FINISHED GRADE AT
TOE ON BOTH SIDES
16"
8"
EXST GROUND
FINISHED GRADE
FREEBOARD
EXISTING HIGH GROUND
1
25
24
26
27
28
29
19202122
23
24
25
26
27
28
29
28
27
26
25
24
23
23
22
CEDAR RIVER
X X X X X X X X X X X X X4+00 5+00 6+00 7+00
o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o
100-YEAR FLOOD EXTENTS
EXST USACE
LEFT BANK ALIGNMENT
A
C-104EXST ACCESS
ROAD
END CONSTRUCTION
STA 33+50.00
6
7
EXST
GUARDRAIL
3
EXCAVATION LIMITS
EXST CITY WATER
LINE CROSSING
UNDER CEDAR RIVER
4 5
CONSTRUCTION ALIGNMENT
ALONG CENTERLINE OF WALL
9
5
30+00 31+00 32+00 33+00
CONSTRUCTION NOTES1.FLOODWALL RAISE PER DETAIL 1, C-104.2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.3.REMOVE EXISTING BIRD PREVENTION WIRE ALONG LENGTH OFFLOODWALL RAISE. SEE SHEET TEC-02.4.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACTSPECIFICATION SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BESUBSTITUTED PROVIDED IT MEETS THIS SPECIFICATION.5.PROTECT EXISTING CATCH BASIN.6.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.7.REMOVE AND RESET BEAM GUARDRAIL FOR FULL LENGTH OFREINFORCED CONCRETE CURB WALL. THE FACE OF GUARDRAIL SHALLBE FLUSH WITH THE FACE OF THE REINFORCED CONCRETE CURB WALL.8.INSTALL BEAM GUARDRAIL ANCHOR TYPE 10 PER WSDOT STANDARDPLAN C-23.60-04.9.WHERE FLOODWALL TOP IS LESS THAN 6' ABOVE EXISTING GROUND,BOLT AIRPORT SECURITY FENCE TO TOP OF FLOODWALL. ADJUST FENCEHEIGHT SO THAT THE TOP OF FENCE IS 6' ABOVE ADJACENT GRADE. (BYOTHERS).CONSTRUCTION NOTES1.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACT SPECIFICATIONSECTION 2-03. NATIVE MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THISSPECIFICATION.2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.3.REMOVE AND RESET BEAM GUARDRAIL IN ORIGINAL ALIGNMENT FOR FULL LENGTHOF CONCRETE CURB WALL. THE FACE OF THE GUARDRAIL SHALL BE FLUSH WITHTHE FACE OF THE CONCRETE CURB WALL.4.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.5.PROTECT EXISTING CARSONITE MARKER.
COORDINATE TABLE
POINT
5
6
7
9
NORTHING
182323.10
182327.40
182298.95
182327.25
EASTING
1299356.32
1299353.88
1299349.24
1299353.29
DESCRIPTION
END SECURITY FENCE
END CONCRETE CURB WALL (WALL CENTERLINE)
END CONSTRUCTION
END GUARDRAIL
CONSTRUCTION NOTES
1.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACT SPECIFICATION
SECTION 2-03. NATIVE MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THIS
SPECIFICATION.
2.CONCRETE CURB WALL PER SECTION A, SHEET C-104.
3.REMOVE AND RESET BEAM GUARDRAIL IN ORIGINAL ALIGNMENT FOR FULL LENGTH
OF CONCRETE CURB WALL. THE FACE OF THE GUARDRAIL SHALL BE FLUSH WITH
THE FACE OF THE CONCRETE CURB WALL.
4.INSTALL AIRPORT SECURITY FENCE PER DETAIL 3, SHEET C-104.
5.PROTECT EXISTING CARSONITE MARKER.
1
3
4
5
2
0
SCALE:
10'20'40'
1'' = 20' ON 22X34 SHEET
CONCRETE CURB WALL PLAN
SCALE: 1" = 20'
CONCRETE CURB WALL PROFILE
SCALE: HORIZ: 1" = 20' VERT: 1" = 4'NDATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 C-102 RAISE FLOODWALL AND EMBANKMENT.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
33
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
KEY MAP
SCALE: 1" = 1000'
N
SITE LOCATION
LB STA 30+00 TO 33+50
LEVEE EMBANKMENT WITH CURB WALL
PLAN AND PROFILEMATCHLINE - STATION 3+50SEE SHEET C-102MATCHLINE - STATION 3+50SEE SHEET C-102
8"3'±EXISTING ASPHALT
PAVEMENT
RESTORED GRASS STRIP
SEE LANDSCAPE SHEET
L-08 FOR PLANTING PLAN.18"3/4" CHAMFER
FINISHED
GROUND
EXST
GROUND
CONCRETE CURB WALL
3" CLEAR MIN
#4 @ 12"6"VARIES#4 LONGITUDINAL
BARS
EXST GROUND
#4 LONGITUDINAL BARS
#4 DOWEL BARS
@ 12" O.C.
EXST CONC FLOODWALL
LONGITUDINAL SECTION
NTS
CROSS SECTION
NTS6"VARIESxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxEXST CONC
FLOODWALL
FLOODWALL NOTES
1.WHERE THE RAISED FLOODWALL TOP IS LESS THAN 6' ABOVE EXISTING GROUND,
BOLT AIRPORT SECURITY FENCE TO TOP OF FLOODWALL. ADJUST FENCE HEIGHT SO
THAT THE TOP OF FENCE IS 6' ABOVE ADJACENT GRADE. SEE DETAIL 3, THIS SHEET
FOR AIRPORT SECURITY FENCE.
1
1
12"12"
1" EXPANSION JOINTS, MATCH
EXST FLOODWALL LOCATIONS 1
#4 DOWEL BARS
INTO EXST
FLOODWALL (TYP)
@ 12" O.C.
8" EMBEDMENT
STANDARD HOOK EXST GROUND 2' FREEBOARD
100 YEAR WSE
3
1
EXST
GUARDRAIL
EXST PAVEMENT
1
4
CONCRETE CURB WALLA
C-103 NTS
EXCAVATION
LIMITS
34
1
2
CONCRETE CURB WALL NOTES
1.BACKFILL SHALL BE WITH LEVEE EMBANKMENT FILL PER CONTRACT SPECIFICATION
SECTION 2-03. NATIVE MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THIS
SPECIFICATION.
2.REMOVE AND RESET BEAM GUARDRAIL FOR FULL LENGTH OF CONCRETE CURB
WALL. THE FACE OF THE GUARDRAIL SHALL BE FLUSH WITH THE FACE OF THE
CONCRETE CURB WALL.
3.FILL ON BACKSIDE OF CURB WALL SHALL BE COMMON BORROW PER 9-03.14(3).
SLOPE AT MAX 2H:1V FROM BACK OF CURB WALL TO EXCAVATION LIMIT.
4.CONCRETE CURB WALL PER DETAIL 2, THIS SHEET. TOP OF WALL ELEVATION PER
PROFILE, SHEET C-103.
5.AIRPORT SECURITY FENCE. SEE DETAIL 3, THIS SHEET.
1
3
4
2
5
5
STEEL POST SCHEDULE
USE AND SECTION
CORNER, END & PULL POSTS
TUBULAR - ROUND
LINE POSTS
TUBULAR - ROUND
BOTTOM & BRACE RAILS
TUBULAR - ROUND
LINE POST
EXTENSION ARM DETAILS
CORNER POST
BRACE RAIL ATTACHMENT
END OR GATE POST DETAIL
TENSION BAND DETAIL
FASTENING DETAILS
LINE POST ATTACHMENTS
BRACE RAIL CLAMP DETAIL
TRUSS ROD AND BAND
BRACE PANEL DETAIL
PROVIDE BRACE PANEL WHENEVER
STRAIGHT RUNS EXCEED 500 FEET.
NOTE:
GROUNDING DETAIL
10' MAXIMUM
10' MAXIMUM
LINE POSTS TO BE EQUALLY SPACED
16" MIN. DIA.12"1/2" (TYP.)
10' MAX.10'12"45°24"35°12"NO SCALE
MINIMUM OUTSIDE
DIMENSIONS (NOMINAL)A.WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED ON THE SECURE
SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK FABRIC SHALL BE PLACED ON THE SIDE
OPPOSITE THE SECURE AREA.
B.ONLY 9-GAGE GALVANIZED STEEL TIE WIRES SHALL BE USED FOR FASTENING THE
FENCE FABRIC TO FENCE POSTS AND RAILS. 16-GAGE, STAINLESS STEEL TIE WIRES
SHALL BE USED FOR FASTENING FENCE FABRIC TO TENSION WIRES. HOG RINGS
SHALL NOT BE ALLOWED ON SENSORED FENCES.
C.BOTTOM RAIL SHALL BE ATTACHED TO DOUBLE RAIL ENDS USING 1
2" CARRIAGE BOLTS
AS SHOWN. ADDITIONAL HOLES SHALL BE DRILLED THROUGH THE BOTTOM RAIL ENDS
TO ENSURE THAT CARRIAGE BOLTS PASS THROUGH THE BOTTOM RAIL AS SHOWN.
D.ALUMINUM OR ALUMINIZED MATERIAL SHALL BE ISOLATED FROM CONCRETE USING
HDPE OR APPROVED EQUAL IN ALL LOCATIONS. STAINLESS STEEL ANCHORS SHALL BE
USED TO ATTACH ALUMINUM TO CONCRETE.6"36"6'1" MAX10" MIN. DIA.
6" (TYP.)
24"
8" (T
Y
P.)
2 7/8" O.D.
2" O.D.12"HORIZONTAL CONNECTION
2 3/8" O.D.
1.3 STRAND BARBED -WIRE APRON ON EXTENSION ARMS
2.TOP TENSION WIRE, 2" BELOW TOP OF FABRIC
3.BRACE RAIL
4.9-GAGE STEEL TIE WIRES, 16" O.C.
MAX & W/IN 4" FROM TOP & BOTTOM OF FABRIC
5.TRUSS ROD (1
2" MIN. DIA.)
6.CORNER, END, OR PULL POST
7.LINE POST
8.9-GAGE STEEL TIE WIRES (TYP.),(12" O.C. MAX.)
9.CHAIN-LINK FABRIC (9 GAGE, 2" MESH), BLACK
WEATHER RESISTANCE GRATED STEEL WIRE
10.BOTTOM OF FABRIC, ABOVE FINISHED GRADE - 1 1
2" MIN,
2 1
2" MAX
11.BOTTOM TENSION WIRE, 2" ABOVE BOTTOM OF FABRIC
12.CONCRETE BASE
13.GRADE LINE
14.TENSION BAND (16" O.C. MAX. & W/IN
2" FROM TOP & BOTTOM OF FABRIC)
15.TENSION BAR TO ENGAGE EACH FABRIC LINK
16.CARRIAGE BOLT W/PEENED THREADS
17.PULL POST
18.#8 AWG SOLID COPPER WIRE
19.MOLDED EXOTHERMIC WELD OR APPROVED
CLAMP-TYPE FITTING OF COPPER
20.3" DIA. COPPER-CLAD STEEL GROUND ROD
21.ENDS TWISTED AT LEAST THREE FULL TURNS
22.1
2" PLAIN PIN RIVETED FLUSH (TYP.)
23.SECURE SIDE
24.LOCK PIN, TYP
25.1" X 1
8" FLAT BAR FASTEN TO STEEL BEAM
26.1
2" BOLT
10' MAX.
SECURITY FENCE NOTES
NO SCALE
NO SCALE
NO SCALE
SECURITY FENCE KEY NOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1
2
2
2
3
3 3
4
4
5
5
5 5
6
5
7
7
7 7
7
8
8
9 9
9
9
10
11
11
12
12
13
14
14
15
16
17
18
19
20
21
22 22
23 23
24 24
25
26
12"
FLOODWALL RAISE WITH CAST-IN-PLACE CONCRETE
SCALE: NTS1
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\T35277 C-104 FLOODWALL ADDITION AND LEVEE EMBANKMENT WITH CURBWALL DETAILS.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
CONCRETE CURB WALL DETAIL
SCALE: NTS2
LB STA 26+50 TO 33+50
FLOODWALL ADDITION AND LEVEE EMBANKMENT WITH CURBWALL
DETAILS
AIRPORT SECURITY FENCE DETAIL
SCALE: NTS3
34
35
35
3530
38
30
29
37
34
33
31
323533343736OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
CEDAR RIVER
100' FROM LOGAN AVENUE BRIDGE
56+50 57+00
57+50
58+00 58+5059+0
0
55+00 55+20 55+40 55+60
55+80
56+00
56+20
56+40
56+60
56+80
57+00
57+20
57+40
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+50FC
C
C
C
C
C C
C
C
100-YEAR FLOOD
EXTENTS
LOGAN
AVENUE
BR
IDGE
A
C-106
1
2
3
4
EXCAVATION LIMIT
TEST HOLE #1A
EG 30.10
IE 25.02
TEST HOLE #1
EG 30.06
IE 26.23
TEST HOLE #3
EG 34.98
IE 27.15
LAKE WASHINGTON LOOP TRAIL
PROJECT LIMITS (PERMIT ###).
IMPROVEMENTS BY OTHERS.
1
2
2
2
2
3
3
4
5
6 12
9
B
C-106 C
C-106 D
C-106
7 3533343635313233348
5
6
EXST FLOODWALL
FL 30.1±
MATCH EXST FL 36.5±
MATCH EXST
13
14
10
11
11
CONSTRUCTION ALIGNMENT
ALONG LANDWARD FACE OF WALL
5
MSE FLOODWALL
LEVELING PAD
EXCAVATION
LIMIT
14
7
8
9
10 36BEGIN CONSTRUCTION
STA 0+00.00 END CONSTRUCTION
STA. 1+50.00
USACE LEFT
BANK ALIGNMENT
12 END OF EXST WALL
STA 0+28.55
OFF 15.47'L
15
16
CONSTRUCTION NOTES
1.SHORE ON SOUTHERN END OF WALL EXCAVATION TO PROTECT NEW
SIDEWALKS, RAMPS, AND ROAD INSTALLED UNDER THE LAKE
WASHINGTON LOOP TRAIL PROJECT.
2.PROTECT EXISTING CATCH BASIN / MANHOLE.
3.PROTECT EXISTING 12" HIGH PRESSURE WATER MAINS (BOEING).
CONTRACTOR TO VERIFY IN FIELD VIA POTHOLING.
4.PROTECT EXISTING 12" WATER LINE (CITY OF RENTON). CONTRACTOR
TO VERIFY IN FIELD VIA SURFACE LOCATES.
5.RESTORE 16" STOPBAR IN PAVEMENT RESTORATION AREA PER CITY
OF RENTON STANDARD PLAN 128.
6.PROTECT EXISTING 4" GAS (PSE). CONTRACTOR TO VERIFY IN FIELD
VIA SURFACE LOCATES.
7.SAWCUT EXISTING ROAD AND REPLACE PAVEMENT PER CITY OF
RENTON STANDARD PLAN 110.1.
8.STEP MSE FLOODWALL IN SINGLE-BLOCK INCREMENTS. SEE WALL
PROFILE, THIS SHEET.
9.INSTALL CEMENT CONCRETE TRAFFIC CURB AND GUTTER PER CITY
OF RENTON STANDARD PLAN 101 ON THE NORTHEAST SIDE OF
PERMITER ROAD.
10.PROTECT EXISTING FLOODWALL.
CONSTRUCTION NOTES (CONT.)
11.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B)
AS SHOWN ON SHEET L-09.
12.PLACE 20' WIDTH OF 4" THICK CSBC. SEE MSE FLOODWALL AT
ACCESS POINT, SECTION D, C-106.
13.RELOCATE EXISTING STOP SIGN.
14.RELOCATE EXISTING NO PARKING / BIKE ROUTE / E. PERIMETER RD.
SIGNS FROM CURRENT LOCATION TO NEW LOCATION BEYOND MSE
FLOODWALL.
15.STEEL PIPE HANDRAIL PER CITY OF RENTON STANDARD PLAN H024.
FOUNDATION FOR HANDRAIL SHALL BE PER MSE FLOODWALL
MANUFACTURER SPECIFICATIONS.
16.INSTALL ASPHALT RAMP PER DETAIL 3, SHEET C-106.
17.ADJUST GEOTEXTILE LOCATION UPWARDS BY ONE (1) MASONRY
BLOCK WHERE THE WALL HEIGHT INCREASES.
18.PROTECT EXISTING 24" SEWER (KING COUNTY). CONTRACTOR TO
VERIFY IN FIELD VIA SURFACE LOCATES.
19.GRAVEL LEVELING PAD PER DETAIL 1, SHEET C-106.
20.LEVELING PAD STEP PER DETAIL 2, SHEET C-106.
6
2
3
4
5
1
7
8
9
10
11
12
13
14
TRAFFIC CONTROL NOTES
1.THE CONTRACTOR SHALL BE RESPONSIBLE
FOR PREPARING AND IMPLEMENTING A
TRAFFIC CONTROL PLAN. THE CONTRACTOR
SHALL SUBMIT A TRAFFIC CONTROL PLAN TO
THE ENGINEER FOR REVIEW AND APPROVAL
PRIOR TO START OF ANY CONSTRUCTION
ACTIVITY.
15
16
17
18
19
20
COORDINATE TABLE
POINT
1
2
3
4
5
6
7
8
9
10
11
12
NORTHING
180285.97
180278.02
180269.67
180178.61
180273.67
180170.51
180282.10
180226.90
180222.80
180216.14
180166.66
180272.64
EASTING
1300117.84
1300123.90
1300130.26
1300199.68
1300118.20
1300196.81
1300121.01
1300161.07
1300155.70
1300146.95
1300208.75
1300147.45
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN MSE FLOODWALL / BEGIN STEPPED WALL
(LANDWARD FACE OF WALL)
END STEPPED WALL (LANDWARD FACE OF WALL)
END MSE FLOODWALL (LANDWARD FACE OF
WALL)
BEGIN CURB AND GUTTER (FLOW LINE)
END CURB AND GUTTER (FLOW LINE)
BIKE ROUTE, NO PARKING, AND STREET SIGN AND
POST
STOP SIGN AND POST
STOP BAR CENTER (CURBSIDE)
STOP BAR CENTER (ROADSIDE)
END CONSTRUCTION
END OF EXISTING FLOODWALL (CENTERLINE)
25
30
35
40
25
30
35
40
2' MINIMUM
FREEBOARD
3' MINIMUM
FREEBOARD
4.1'±3.6'±10
12
1
19
20 (TYP)
17
17
STA 0+20.50
T/W 36.3'±
EXST FLOODWALL
B/FTG 28.11'
B/FTG 28.78'
B/FTG 29.45'
B/FTG 30.11'
B/FTG 30.78'
B/FTG 31.45'
B/FTG 32.11'
B/FTG 32.78'
B/FTG 33.45'
STA 0+72.25
T/W 36.3'±
STA 1+35.00
T/W 36.9'±
MATCH EXST
EG 36.6'±
STA 0+20.50
FG 35.50' MIN
1.5H:1V
GEOGRID (TYP)
EXCAVATION
LIMITS
STA 1+12.6±
12" EXST HPW CROSSING
IE 27.0'±
STA 1+15.6±
12" EXST HPW CROSSING
IE 28.2'±
2H:1V
EXST GROUND
(RIVERWARD TOE OF FLOODWALL)
FINISHED GRADE
(RIVERWARD TOE OF FLOODWALL)
3
3
17
EXST GROUND
(LANDWARD TOE OF FLOODWALL)
15
STA 0+89.9±
24" EXST SS CROSSING
IE 17.4'±
STA 0+72.25
T/W 36.9'±EXST HIGH
GROUND (RIVERWARD
OF FLOODWALL)
100' FROM LOGAN
AVENUE BRIDGE
STA 0+10.00
T/W 31.6'±STEP WALL DOWNTO APPROXIMATE2H:1V SLOPE8FREEBOARD
FREEBOARD
15 15
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+50
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-106 WIDEN LEVEE EMBANKMENT.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR
OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUMMSE FLOODWALL PLAN
SCALE: 1" = 10'
0
SCALE:
5'10'20'
1" = 10' ON 22X34 SHEETN
KEY MAP
SCALE: 1" = 1000'
N
SITE LOCATION
8' MIN TOP OF
LEVEE WIDTH
LB STA 55+40 TO 56+90
WIDEN LEVEE EMBANKMENT
PLAN AND PROFILE
MSE FLOODWALL PROFILE
SCALE: HORIZ: 1" = 10' VERT: 1" = 2' ON 22X34 SHEET
15
20
25
30
35
40
45
15
20
25
30
35
40
45
0 5 10 15 200-5-10-15-20 EXST 12" HPWLOCATION APPROX.IE 25.2' ±EXST 12" HPWLOCATION APPROX.IE 26.4' ±EXST 4" GASLOCATION APPROX.IE 27.5' ±3362' FREEBOARD
EXST
GROUND
EXST 24" SS
LOCATION APPROX.
IE 17.4' ±
FINISHED
GRADE
GEOGRID (TYP)
GRAVEL BACKFILL
FOR WALLS
8' MIN CROWN
WIDTH
EXCAVATION
LIMIT
EXST
FLOODWALL
1.5H:1V
(TYP)
MSE WALL
11" WIDTH
6'
7'
6'-8" PEDESTRIAN
PATH
EXST 12" WATER
LOCATION APPROX.
IE 26.4 ±
EXST 24" STORM
LOCATION APPROX.
IE 23.8' ±
9
7
8
4
22.8'
5
13
1'
MIN
4.5'±
2.7'±1.6'±
1
11
15
20
25
30
35
40
45
15
20
25
30
35
40
45
0 5 10 15 200-5-10-15-20
3' FREEBOARD
EXST 24" SS
LOCATION APPROX.
IE 17.4' ±EXST 12" HPWLOCATION APPROX.IE 25.9' ±EXST 12" HPWLOCATION APPROX.IE 27.1' ±EXST 4" GASLOCATION APPROX.IE 27.5' ±336EXST 12" WATER
LOCATION APPROX.
IE 28.2' ±
7'
8'
FINISHED
GRADE
GEOGRID (TYP)
GRAVEL BACKFILL
FOR WALLS
8' MIN CROWN
WIDTH
EXCAVATION LIMIT
MSE WALL
11" WIDTH
4' MIN PEDESTRIAN
ACCESS ROUTE
30" STOP SIGN
7'6'-8" PEDESTRIAN
PATH
EXST
GROUND
EXST 24" STORMLOCATION APPROX.IE 23.9' ±6'
9
7
8
4
2
12
5
8.4'±
4.8'±
3.4'±
1.5H:1V (TYP)13
1'
MIN
1
2.7'
15
20
25
30
35
40
45
15
20
25
30
35
40
45
0 5 10 15 200-5-10-15-20
3' FREEBOARD EXST
GROUND
EXST 4" GASLOCATION APPROX.IE 27.7' ±6EXST 24" SS
LOCATION APPROX.
IE 17.4' ±
EXST 12" WATER
LOCATION APPROX.
IE 31.7' ±EXST 24" STORMLOCATION APPROX.IE 24.0' ±EXST 12" HPWLOCATION APPROX.IE 27.5' ±3EXST 12" HPWLOCATION APPROX.IE 28.6' ±38'
FINISHED GRADE
GEOGRID (TYP)
GRAVEL BACKFILL FOR
WALLS PER CONTRACT
SPECIFICATION 6-13
8' MIN CROWN
WIDTH
EXCAVATION LIMIT
1.5H:1V
(TYP)
MSE WALL
11" WIDTH
6'-8" PEDESTRIAN
PATH
2.9'
9
7
8
4
2
10H:1V 10
7.3'±
5.0'±
13
1'
MIN 6.1'±
15
20
25
30
35
40
45
15
20
25
30
35
40
45
0 5 10 15 200-5-10-15-20
3' FREEBOARD
EXST 24" SS
LOCATION APPROX.
IE 17.4' ±EXST 4" GASLOCATION APPROX.IE 27.6' ±6EXST 12" WATER
LOCATION APPROX.
IE 30.8' ±EXST 24" STORMLOCATION APPROX.IE 24.0' ±PIPES ADJACENT TO
SECTION ARE SHOWN
FOR REFERENCE
12" EXST HPW
12" EXST HPW
SKEWED
6.4' PIPE
CROSSING
3
8'
EXST
GROUND
FINISHED GRADE
GRAVEL BACKFILL
FOR WALLS
8' MIN CROWN
WIDTH
EXCAVATION LIMIT
MSE WALL
11" WIDTH
6'-8" PEDESTRIAN
PATH
2.7'
9
7
8
4
2
SLOP VARIES
TRANSITION AREA
BETWEEN 10% AND 0%
5
4.7'±
13
1'
MIN
1.5H:1V (TYP)
GEOGRID (TYP)
7.3'±
1
2'-0"6"61
2"11"
STANDARD MASONRY UNIT
(MSE FLOODWALL)
1/2"-3/4" CRUSHED STONE OR GRAVEL
PER CONTRACT SPECIFICATIONS 6-13
(95% STANDARD PROCTOR DENSITY)6"8"9"1'-6"
6"45°'
STANDARD MASONRY UNIT
(MSE FLOODWALL)
1/2"-3/4" CRUSHED STONE OR GRAVEL
PER CONTRACT SPECIFICATIONS 6-13
(95% STANDARD PROCTOR DENSITY)
PLAN
ELEVATION
NOTES
1.REMOVE A MINIMUM OF 3' (FT)
OF EXISTING SHOULDER AT
THE BOTTOM OF THE RAMP,
FOR EMBEDMENT OF NEW HMA.
SIDEWALK HMA SIDEWALK RAMP
EXISTINGSHOULDEREXISTING JOINT SEAL
PREMOLDED JOINT FILLER ~ MATCH
WIDTH OF EXISTING JOINT SEAL
3' - 0" MIN.
(SEE NOTE 1)
1.5% MAX
6"
7.5% MAX
HEIGHT VARIES
0" - 6"
SAWCUT IN EXISTING PAVEMENT
SEE NOTE 1
SECTION
2" HMA CL 1/2"
PG 64-22
PROPOSED MSE WALL
6' - 8" PEDESTRIAN PATH
EDGE OF TRAVELED WAY
EXISTING SHOULDER
(SEE NOTE 1)
SIDEWALK RAMP (HMA)
SELECT FILL
6"
10'
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-106 WIDEN LEVEE EMBANKMENT.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
MSE FLOODWALL SECTION - HPW CROSSINGA
C-105 SCALE: HORIZ: 1" = 5' VERT: 1" = 5' ON 22X34 SHEET
MSE FLOODWALL SECTION - STOP SIGN RELOCATIONB
C-105 SCALE: HORIZ: 1" = 5' VERT: 1" = 5' ON 22X34 SHEET
MSE FLOODWALL SECTION - HPW CROSSINGC
C-105 SCALE: HORIZ: 1" = 5' VERT: 1" = 5' ON 22X34 SHEET
MSE FLOODWALL SECTION - MAINTENANCE ACCESSD
C-105 SCALE: HORIZ: 1" = 5' VERT: 1" = 5' ON 22X34 SHEET
CONSTRUCTION NOTES
1.STEEL PIPE HANDRAIL PER CITY OF RENTON STANDARD PLAN H024.
FOUNDATION FOR HANDRAIL SHALL BE PER MSE FLOODWALL
MANUFACTURER SPECIFICATIONS.
2.SAWCUT EXISTING ROAD AND REPLACE PAVEMENT 2' OFFSET FROM
EDGE OF NEW CURB AND GUTTER PER CITY OF RENTON STANDARD
PLAN 103.
3.PROTECT EXISTING 12" HIGH PRESSURE WATER MAINS (BOEING).
CONTRACTOR TO VERIFY IN FIELD VIA POTHOLING.
4.INSTALL CEMENT CONCRETE TRAFFIC CURB AND GUTTER PER CITY
OF RENTON STANDARD PLAN 101 ON NORTHEAST SIDE OF
PERIMETER ROAD.
5.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B)
AS SHOWN ON SHEET L-09.
6.PROTECT EXISTING 4" GAS (PSE). CONTRACTOR TO VERIFY IN FIELD
VIA SURFACE LOCATES.
7.GRAVEL LEVELING PAD PER DETAIL 1, THIS SHEET.
8.BACKFILL WITH CSBC.
9.LEVEE EMBANKMENT FILL SHALL BE IN ACCORDANCE WITH
CONTRACT SPECIFICATION SECTION 2-03. EXCAVATED NATIVE
MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THIS
SPECIFICATION.
10.4" DEPTH CSBC.
11.PROTECT EXISTING FLOODWALL.
12.SIGN MOUNTING POST PER CITY OF RENTON STANDARD PLAN 129.
13.6" HMA CL 1/2" PG 64-22 OR MATCH EXISTING THICKNESS.
6
2
3
4
5
1
7
8
9
10
11
12
LB STA 55+40 TO 56+90
WIDEN LEVEE EMBANKMENT SECTIONS
----
GRAVEL LEVELING PAD - SECTION VIEW
SCALE: NTS1
LEVELING PAD STEP - PROFILE VIEW
SCALE: NTS2
13
ASPHALT RAMP
SCALE: NTS3
25
30
35
40
45
25
30
35
40
45
0+00 1+00 2+00 3+00
100' FROM LOGAN
AVENUE BRIDGE
2' MINIMUM
FREEBOARD
3' MINIMUM
FREEBOARD
T/W 38.0' MIN
T/W 37.4' MIN
T/W 37.3' MIN
EXCAVATION
LIMITS
TOP OF EXST
WALL
EXST GROUND AT
LOGAN AVENUE BRIDGE
EXST GROUND
ADJACENT TO
EXST WALL
2
4
3
2
EXST CONCRETE WALK
1.5H:1V
EXST HIGH GROUND TIE IN
100 YEAR WSE
TEST HOLE #6A
IE 29.1'±
TEST HOLE #6
IE 26.6'±
12
8
T/FTG
B/FTG
B/FTG KEY
14
EXST GROUND
EXST WALL
EXST WALL
EXST HIGH GROUND
RIVERWARD SIDE
TOP OF OVERBUILD FILL 37.8'±
TOP OF EMBANKMENT FILL 36.4' MIN
T/W 37.3' MIN
TOP OF EMBANKMENT FILL 36.4' MIN 8
3 6
5
7
1.5H:1V
SHORING
FREEBOARD
FREEBOARD
11
17
6
5 T/W 37.3'
MIN
T/W 37.3'
MIN
TOP OF EXST
WALL
CEDAR RIVE
R
100' FROM LOGAN AVENUE BRIDGE
8
57+
4
0
57+
6
0
57+
8
0
58+
0
0
58+
2
0
58+
4
0
58+6
0
58+8
0
59+0
0
59+20
59+40
59+6
0
59
+
8
0
6
0
+
0
0
6
0
+
2
0
6
0
+
4
0
60+60
0+00
1+00
2+00
LIMIT OF TOP OF
EMBANKMENT FILL100-YEAR FLOOD EXTENTSLOGAN AVENUE
BR
IDGE
EXCAVATION LIMIT
C
-
A
-
3
32
6
4
24
13
1
12
8
8
9
5
8
9
9
TEST HOLE #6
TEST HOLE #6A
B
-
35
35
33
34
36
3
6
5
13
14
BEGIN CONSTRUCTION
STA 58+00.00
CONSTRUCTION ALIGNMENT
ALONG CENTERLINE OF WALL
AND EMBANKMENT
L2S TRAIL
15
CB1
N 180028.97
E 1300363.65
RIM= 33.5'±
IE OUT= 31.20' (8", SE)
STA 0+93.19
STA 1+48.67
STA 0+86.43
STA 1+75.01
7
2
10
CB2
N 179969.48
E 1300389.59
RIM= 33.1'±
IE IN= 30.85 (8", NW)
IE IN= 30.8'± (4", S)
IE OUT= 30.8'± (4", N)
EXST USACE
LEFT BANK
ALIGNMENT
16
19
65 LF 8" PVC @ 0.5%
19
STA 0+80.35
END CONSTRUCTION
STA 60+50.00
STA 0+32.97
STA 2+18.75
14.2' EMBANKMENT WIDTH
8.0' EMBANKMENT WIDTH
EXST CONC WALL
VARIESCONCRETE FLOODWALL RAISE SECTIONA
_NTS
EXST SIDEWALK
EXST GROUND
EXISTING CURB
AT LOGAN AVE.
6.5' ±LOGAN AVENUE
1
18
COORDINATE TABLE
POINT
1
2
3
4
5
6
7
8
9
NORTHING
180110.86
180098.02
180051.51
180047.29
180041.82
180032.68
180010.92
179976.57
179926.95
EASTING
1300285.68
1300312.61
1300303.67
1300308.04
1300312.01
1300366.73
1300381.58
1300408.64
1300425.01
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN FLOODWALL RAISE (WALL CENTERLINE)
END FLOODWALL RAISE (WALL CENTERLINE)
BEGIN REINFORCED CONCRETE FLOODWALL TYPE 2 (WALL CENTERLINE)
ANGLE POINT (WALL CENTERLINE)
ANGLE POINT (WALL CENTERLINE)
END REINFORCED CONCRETE FLOODWALL TYPE 2 /BEGIN EMBANKMENT (WALL/EMBANKMENT CENTERLINE)
END EMBANKMENT (EMBANKMENT CENTERLINE)
END CONSTRUCTION
CONSTRUCTION NOTES
1.FLOODWALL RAISE PER DETAIL 1, C-108.
2.REINFORCED CONCRETE FLOODWALL TYPE 2 PER
DETAIL 2, C-108.
3.RAISE EMBANKMENT PER SECTION C, THIS SHEET.
4.TAPER EMBANKMENT AND OVERBUILD AT
TRANSITION TO CONCRETE FLOODWALL.
5.LEVEE EMBANKMENT FILL SHALL BE IN
ACCORDANCE WITH CONTRACT SPECIFICATION
SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY
BE SUBSTITUTED PROVIDED IT MEETS THIS
SPECIFICATION.
6.EMBANKMENT OVERBUILD FILL SHALL BE 6" MIN,
THE TOP 4" SHALL BE TOPSOIL, THE REMAINDER
SHALL BE COMMON BORROW PER 9-03.14(3).
7.STRIP EXISTING TOPSOIL AND STOCKPILE FOR
RE-USE.
CONSTRUCTION NOTES (CONT.)
8.PROTECT EXISTING 12" HIGH PRESSURE WATER
MAINS (BOEING).
9.PROTECT EXISTING 24" SEWER MAIN (KING
COUNTY).
10.INSTALL NEW CONCRETE INLET PER CITY OF
RENTON STANDARD PLAN 200.30.
11.BACKFILL SHALL BE LEVEE EMBANKMENT FILL IN
ACCORDANCE WITH CONTRACT SPECIFICATION
SECTION 2-03.
12.PROTECT EXISTING 1" UNKNOWN UTILITY.
13.REPLACE EXISTING CATCH BASIN WITH CATCH
BASIN TYPE 2 PER CITY OF RENTON STANDARD
PLAN 201.00.
14.SEED, FERTILIZE, AND MULCH AND PLACE
TOPSOIL (WSDOT TYPE B) AS SHOWN ON SHEET
L-09.
CONSTRUCTION NOTES (CONT.)
15.PROTECT EXISTING SHRUBS.
16.CONTRACTOR TO FIELD LOCATE EXISTING PIPE
AND INSTALL NEW CATCH BASIN TYPE 1 PER CITY
OF RENTON STANDARD PLAN 200.00. THE CATCH
BASIN SHALL INTERCEPT THE EXISTING PIPE AND
FLOW THROUGH THE STRUCTURE IN THE
POST-CONSTRUCTION CONDITION, AS COMPARED
TO THE PRE-CONSTRUCTION CONDITION, SHALL
NOT BE INHIBITED.
17.EMBED FLOODWALL 5' INTO LANDSCAPE BERM
EMBANKMENT.
18.ELEVATION PER PROFILE. HEIGHT SHALL BE A
MINIMUM OF 6".
19.EXPANSION JOINT. DETAIL TBD @ 100% DESIGN.
6
2
3
4
5
1
7
8
9
10
11
12
13
15
14
16
17
18
19
25
30
35
40
25
30
35
40
0 5 100-5-10
EXCAVATION
LIMIT
11
23' FREEBOARD
EXST
GROUND
100-YR WSE
NEAT LINE EXCAVATION
AROUND KEY
11
25
30
35
40
25
30
35
40
0 5 10 15 200-5-10-15-20
TOP OF OVERBUILD
FG 37.5±
EXCAVATION LIMIT
EXST GROUND
100 YEAR WSE
1.5H:1V
1.5H:1V
3H:1V MAX
2' FREEBOARD
5
7
6 14
BERM TOP WIDTH VARIES,
2' MIN.
0
SCALE:
10'20'40'
1" = 20' ON 22X34 SHEET FLOODWALL AND EMBANKMENT PLAN
SCALE: 1" = 20'
FLOODWALL AND EMBANKMENT PROFILE
SCALE: HORIZ: 1" = 20' VERT: 1" = 4'
N
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-107 REPAIR AND RAISE FLOODWALL.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
KEY MAP
SCALE: 1" = 1000'
N
REINFORCED CONCRETE
FLOODWALL TYPE 2 SECTIONB
_SCALE: HORIZ: 1" = 5' VERT: 1" = 5'
LB STA 58+00 TO 60+00
REPAIR AND RAISE FLOODWALL
PLAN AND PROFILE
SITE LOCATION
CONSTRUCTION CONSTRAINTS
1.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE
CEDAR RIVER TRAIL WILL REQUIRE A RIGHT OF ENTRY
PERMIT AND TRAFFIC CONTROL PLAN. CONTRACTOR
SHALL MAKE EVERY EFFORT TO MINIMIZE IMPACTS TO
CEDAR RIVER TRAIL AND MAINTAIN PEDESTRIAN TRAFFIC.
LANDSCAPE BERM EMBANKMENT SECTIONC
_SCALE: HORIZ: 1" = 5' VERT: 1" = 5'
12"12"6"VARIES#4 LONGITUDINAL
BARS
#4 DOWEL BARS
INTO EXST
FLOODWALL (TYP)
@ 12" O.C.
1" EXPANSION JOINTS,
MATCH EXST FLOODWALL
LOCATIONS
EXST CONC
FLOODWALL
EXST GROUND
#4 LONGITUDINAL BARS
#4 DOWEL BARS
@ 12" O.C.
EXST CONC FLOODWALL
LONGITUDINAL SECTION
NTS
CROSS SECTION
NTS6"MINVARIESELEVATION PER PROFILE.
SEE SHEET C-107.
STANDARD HOOK
8" EMBEDMENT
4'-6"4'-6"1'-3"8"
1'-0 3/4"2'-4 1/2"1'-0 3/4"2'-0"3"2"2"1'-0"1'-6"
3/4" CHAMFER (TYP)
#5@12" O.C. EACH FACE #5@6" O.C. EACH FACE
#5@12" O.C. EACH
WAY, TOP AND BOT
FINISHED GRADE
2-#5 BARS
#5 TIE @ 12" O.C.
FLOODWALL RAISE WITH CAST-IN-PLACE CONCRETE
SCALE: NTS1
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-108 REPAIR AND RAISE FLOODWALL.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
REINFORCED CONCRETE FLOODWALL TYPE 2 DETAIL
SCALE: NTS2
LB STA 58+00 TO 60+00
REPAIR AND RAISE FLOODWALL
DETAILS
25
30
35
40
25
30
35
40
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+30
EXST GROUND
ADJACENT TO
POCKET WALL
1
2
3 5
4
3
5
SOUTH BOEING BRIDGE
100' FROM SOUTH
BOEING BRIDGE
2' MINIMUM
FREEBOARD
3' MINIMUM
FREEBOARD
2H:1V
2H:1V
124
7.2%
5H:1V
100 YEAR WSE
EXCAVATION LIMIT
FLOODWALL/CLOSURE TRANSITION
EXST T/W 32.9'±
TOP OF OVERBUILD
FG 33.3'±
TOP OF LEVEE EMBANKMENT FIILL
EL 32.8' MIN
TOP OF LEVEE EMBANKMENT FILL
EL 32.8' MIN
TOP OF OVERBUILD
FG 33.3'±
MATCH EXST
EG 32.3'±
MATCH EXST
EG 32.2'±
MATCH EXST
EG 31.5'±
MATCH EXST
EG 31.0'±
6
END OF EXST FLOODWALL
EXST T/W 32.8'±
2
FREEBOARD
FREEBOARD
2
5
30
30
25
26
27
28
29
31
322930313228
CEDAR RIVER
48+80 49+00 49+20 49+40 49+60 49+80 50+00 50+20 50+400+00 0+20 0+40 0+60 0+80 1+00 1+20 1+30
FF F F F F
FFF
F
F
F
F
F
F
TOP OF
EMBANKMENT FILL
EXCAVATION LIMIT
100-YEAR FLOOD
EXTENTS
100' FROM SOUTH BOEING BRIDGESOUTH BOEING BRIDGEEXST USACE
RIGHT BANK ALIGNMENT
A
-
8' MIN. CROWN WIDTH
6
5 1
2
3
4
5 6
7
7
TOP OF
EMBANKMENT OVERBUILD
3
9
10
11
12
STA 49+30.00 STA 50+30.00
20
25
30
35
40
20
25
30
35
40
0 5 10 15 20 250-5-10-15-20-25
EXST 8' TRAIL
EXCAVATION
LIMIT
2H:1V MAX SIDESLOPE (TYP)8' MIN CROWN WIDTH
4
7
12 8
100 YEAR WSE
3' FREEBOARD
2
CONSTRUCTION NOTES1.LOCATION OF EXISTING EMBEDDED FLOODWALL AND EXISTING STEEL SHEET PILEWALL ARE APPROXIMATE. LOCATION TO BE VERIFIED IN FIELD BY CONTRACTOR.2.EMBANKMENT OVERBUILD SHALL BE 6" MIN. THE TOP 4" SHALL BE TOPSOIL (WSDOTTYPE B), THE REMAINDER SHALL BE COMMON BORROW.3.EMBED EXISTING FLOODWALL 5' MINIMUM INTO EMBANKMENT AT TRANSITION.4.LEVEE EMBANKMENT FILL SHALL BE IN ACCORDANCE WITH CONTRACTSPECIFICATION SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BESUBSTITUTED PROVIDED IT MEETS THIS SPECIFICATION.5.PROTECT EXISTING FLOODWALL AND POCKET WALL CLOSURE GATE.6.PROTECT EXISTING 4" GAS (PSE).7.NO CONSTRUCTION ACTIVITIES SHALL OCCUR WITHIN 2' OF THE EXISTING TRAIL.8.STRIP EXISTING TOPSOIL AND STOCKPILE FOR RE-USE.9.TAPER EMBANKMENT AT TRANSITION TO EXISTING FLOODWALL.10.ADJUST JUNCTION BOX TO GRADE.11.PROTECT EXISTING LIGHTING POLE.12.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B) AS SHOWN ONSHEET L-06.
COORDINATE TABLE
POINT
1
2
3
4
5
6
7
NORTHING
181781.83
181757.32
181756.84
181751.96
181699.40
181698.92
181684.78
EASTING
1299681.32
1299687.84
1299687.94
1299688.97
1299700.01
1299700.12
1299705.43
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN EMBANKMENT OVERBUILD (EMBANKMENT CENTERLINE)
BEGIN LEVEE EMBANKMENT FILL (EMBANKMENT CENTERLINE)
END OF EXISTING FLOODWALL (WALL/EMBANKMENT CENTERLINE)
END LEVEE EMBANKMENT FILL (EMBANKMENT CENTERLINE)
END EMBANKMENT OVERBUILD (EMBANKMENT CENTERLINE)
END CONSTRUCTION
CONSTRUCTION NOTES
1.LOCATION OF EXISTING EMBEDDED FLOODWALL AND EXISTING STEEL SHEET PILE
WALL ARE APPROXIMATE. LOCATION TO BE VERIFIED IN FIELD BY CONTRACTOR.
2.EMBANKMENT OVERBUILD SHALL BE 6" MIN. THE TOP 4" SHALL BE TOPSOIL (WSDOT
TYPE B), THE REMAINDER SHALL BE COMMON BORROW.
3.EMBED EXISTING FLOODWALL 5' MINIMUM INTO EMBANKMENT AT TRANSITION.
4.LEVEE EMBANKMENT FILL SHALL BE IN ACCORDANCE WITH CONTRACT
SPECIFICATION SECTION 2-03. EXCAVATED NATIVE MATERIAL MAY BE
SUBSTITUTED PROVIDED IT MEETS THIS SPECIFICATION.
5.PROTECT EXISTING FLOODWALL AND POCKET WALL CLOSURE GATE.
6.PROTECT EXISTING 4" GAS (PSE).
7.NO CONSTRUCTION ACTIVITIES SHALL OCCUR WITHIN 2' OF THE EXISTING TRAIL.
8.STRIP EXISTING TOPSOIL AND STOCKPILE FOR RE-USE.
9.TAPER EMBANKMENT AT TRANSITION TO EXISTING FLOODWALL.
10.ADJUST JUNCTION BOX TO GRADE.
11.PROTECT EXISTING LIGHTING POLE.
12.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B) AS SHOWN ON
SHEET L-06.
6
2
3
4
1
7
8
9
5
10
11
12
EMBANKMENT PLAN
SCALE: 1" = 10'
EMBANKMENT PROFILE
SCALE: HORIZ: 1" = 10', VERT: 1" = 2'
0
SCALE:
5'10'20'
1" = 10' ON 22X34 SHEETN EMBANKMENT SECTIONA
_SCALE: HORIZ: 1" = 5' VERT: 1" = 5'
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-109 IMPROVE FLOODWALL TO EMBANKMENT TRANSITION.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
KEY MAP
SCALE: 1" = 1000'
N
RB STA 49+30 TO 50+30
IMPROVE FLOODWALL TO EMBANKMENT TRANSITION
PLAN AND PROFILE
SITE LOCATION
CONSTRUCTION ALIGNMENT ALONG
CENTERLINE OF EMBANKMENT
CONSTRUCTION CONSTRAINTS
1.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE CEDAR RIVER TRAIL WILL
REQUIRE A RIGHT OF ENTRY PERMIT AND TRAFFIC CONTROL PLAN. CONTRACTOR
SHALL MAKE EVERY EFFORT TO MINIMIZE IMPACTS TO CEDAR RIVER TRAIL AND
MAINTAIN PEDESTRIAN TRAFFIC.
30
35
40
30
35
40
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40
100 YEAR WSE
EXISTING
HIGH GROUND
100' FROM LOGAN
AVENUE BRIDGE
3' MINIMUM
FREEBOARD
2' MINIMUM
FREEBOARD
APPROX. SHARED USE
PATH FINISHED GRADE
(BY OTHERS)
TOP OF LEVEE
EMBANKMENT FILL
4H:1V
2H:1V
4H:1V
EXCAVATION
LIMITS
SHORING
2
TOP OF OVERBUILD
FG 36.3'±2
TOP OF LEVEE EMBANKMENT FILL
EL 35.8' MIN3
5 TOP OF LEVEE
EMBANKMENT FILL
EL 36.0' MIN
(VERIFY IN FIELD)
LAKE WASHINGTON
LOOP TRAIL PROJECT
(BY OTHERS)
5
6
TOP OF OVERBUILD
1.5H:1V
FREEBOARD
FREEBOARD
4
3
4
35
35
363433 34353435 34 33 363738T T
T
T
100' FROM LOGAN
AVENUE BRIDGE
100-YEAR FLOOD EXTENTS
0+00
0+20
0+40
0+60
0+80
1+0
0
1+2
0
1
+4
0
1
+
6
0
1+80
1+95.
0
9
63+20
63+40
63+60
63+80
64+00
64
+
2
0
64+40
64+60
64+80
LOGAN
AVENUE
BR
IDGE
A
-
EXISTING USACE
RIGHT BANK ALIGNMENT
EXCAVATION LIMIT
LAKE WASHINGTON LOOP TRAIL
PROJECT LIMITS (PERMIT ###).
IMPROVEMENTS BY OTHERS.
BEGIN CONSTRUCTION
STA 63+30.00
END CONSTRUCTION
STA 64+30.00
1
2
3
6
TOP OF EMBANKMENT OVERBUILD
LIMIT OF TOP OF
EMBANKMENT FILL
4
5
FG 35.3'±
EXCAVATION
LIMIT
35
35
36
36
CONSTRUCTION ALIGNMENT ALONG
LANDWARD EDGE OF EMBANKMENT
RENTON MEMORIAL STADIUM PARKING LOT
CED
A
R
R
I
V
E
R
T
R
A
I
L
4
4
3
1
2
5
7
6
SHARED USE PATH
REVISION PER THE LAKE
WASHINGTON TRAIL LOOP
PROJECT (BY OTHERS)
35
FG 36.0' MIN
(VERIFY IN FIELD)5
STA 0+63.59
OFF 11.18'R
25
30
35
40
45
25
30
35
40
45
0 5 10 15 200-5-10-15-20
TOP OF OVERBUILD
EL 36.4'±
TOP OF LEVEE EMBANKMENT FILL
EL 35.89'
EXCAVATION LIMIT
4H:1V (TYP)
(OVERBUILD)
2H:1V MAX SIDESLOPE (TYP)
100 YEAR WSE
2' FREEBOARD
1
21.5H:1V (TYP)
T
COORDINATE TABLE
POINT
1
2
3
4
5
6
NORTHING
180513.99
180509.63
180509.63
180469.96
180462.39
180456.82
EASTING
1300194.01
1300205.27
1300205.27
1300239.99
1300269.86
1300274.34
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN EMBANKMENT OVERBUILD (LANDWARD EDGE OF EMBANKMENT)
BEGIN EMBANKMENT FILL (LANDWARD EDGE OF EMBANKMENT)
END EMBANKMENT OVERBUILD / EMBANKMENT FILL (RIVERWARD EDGE OF EMBANKMENT)
END EMBANKMENT OVERBUILD / EMBANKMENT FILL (LANDWARD EDGE OF EMBANKMENT)
END CONSTRUCTION
CONSTRUCTION NOTES
1.EMBANKMENT OVERBUILD SHALL BE 6" MIN, THE TOP 4" SHALL BE
TOPSOIL, THE REMAINDER SHALL BE COMMON BORROW.
2.LEVEE EMBANKMENT FILL SHALL BE IN ACCORDANCE WITH
CONTRACT SPECIFICATION SECTION 2-03. EXCAVATED NATIVE
MATERIAL MAY BE SUBSTITUTED PROVIDED IT MEETS THIS
SPECIFICATION.
3.PROTECT EXISTING 4" GAS (PSE).
4.PROTECT EXISTING COMMUNICATION LINES AND FACILITIES.
5.TOP OF EMBANKMENT FILL TO BE FLUSH WITH SHARED USE PATH
CONSTRUCTED BY LAKE WASHINGTON LOOP TRAIL PROJECT.
6.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B)
AS SHOWN ON SHEET L-07.
7.REPLACE EXISTING SIDEWALK WITH NEW SIDEWALK LANDING AND
TRANSITION PANEL PER CITY OF RENTON STANDARD PLAN 102.
1
2
3
4
5
7
6
EMBANKMENT PLAN
SCALE: 1" = 10'
EMBANKMENT PROFILE
SCALE: HORIZ: 1" = 10' VERT: 1" = 2'
0
SCALE:
5'10'20'
1" = 10' ON 22X34 SHEETN PLANTING NOTES
1.SEE SHEET L-06 FOR PLANTING NOTES.
EMBANKMENT SECTIONA
_SCALE: HORIZ: 1" = 5', VERT: 1" = 5'
KEY MAP
SCALE: 1" = 1000'
N
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-111 REMOVE AND REPLACE SIDEWALK AREA.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RB STA 63+30 TO 64+30
RAISE LEVEE EMBANKMENT LANDSCAPING BERM
PLAN AND PROFILE
SITE LOCATION
CONSTRUCTION CONSTRAINTS
1.WORK WITHIN CITY OF RENTON PARKS AND NEAR THE CEDAR
RIVER TRAIL WILL REQUIRE A RIGHT OF ENTRY PERMIT AND
TRAFFIC CONTROL PLAN. CONTRACTOR SHALL MAKE EVERY
EFFORT TO MINIMIZE IMPACTS TO CEDAR RIVER TRAIL AND
MAINTAIN PEDESTRIAN TRAFFIC.
30
35
40
30
35
40
0+00 0+10 0+20 0+30 0+40 0+50 0+60
1
2
MATCH EXISTING
EG 37.2'±MATCH EXISTING
EG 37.3'±
FG 37.2' MIN
FG 37.3' MIN
3' FREEBOARD
100 YEAR WSE
0.6'±
1.25%
1
3
4 4
FREEBOARD
403737 3738393735363938
4040
OEOEOEOEOE66
+
0
0
66+
2
0
0+00 0+10 0+20 0+30 0+40 0+50 0+60
0+00
24.5'± 11'±5% MAX3% MAXLIMIT OF
DISTURBANCE
1
2
3
4
5 6
A
-
32
2
1
LOGAN AVE N
4
4
0.4%
2.6%
EG 36.76'EG 36.80'
EG 35.83'
EG 36.04'
FG 37.10'
FG 37.00'
100-YEAR
FLOOD
EXTENTS
EXISTING USACE
RIGHT BANK ALIGNMENT
T
COORDINATE TABLE
POINT NORTHING EASTING DESCRIPTION
CONSTRUCTION NOTES
1.REPLACE SIDEWALK PER CITY OF RENTON STANDARD PLAN 102.
2.SAWCUT, SEE SHEET TEC-04.
3.PROTECT EXISTING 12" HIGH POWER WATER MAIN (BOEING).
LOCATION SHOWN IS APPROXIMATE. COVER DEPTH IS ASSUMED
BASED ON MINIMUM COVER DEPTHS SPECIFIED IN AVAILABLE
AS-BUILT INFORMATION.
4.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B)
AS SHOWN ON SHEET L-07.
5.PROTECT EXISTING OVERHEAD POWER LINE.
6.PROTECT TREE ROOTS.
1
2
3
4
5
6
GENERAL NOTES
1.CONTRACTOR SHALL RESTORE VEGETATED AREAS DAMAGED
DURING CONSTRUCTION PER CONTRACT SPECIFICATION 9-14.
1
2
3
4
5
6
180338.31
180337.61
180313.42
180314.18
180349.36
180348.80
1300376.95
1300384.95
1300381.04
1300372.99
1300375.54
1300385.26
SIDEWALK HIGH GROUND
SIDEWALK HIGH GROUND
SIDEWALK CORNER
SIDEWALK CORNER
SIDEWALK CORNER
SIDEWALK CORNER
0
SCALE:
5'10'20'
1" = 10' ON 22X34 SHEET
SIDEWALK PLAN
SCALE: 1" = 10'
SIDEWALK SECTION
SCALE: HORIZ: 1" = 10' VERT: 1" = 2'A
N
KEY MAP
SCALE: 1" = 1000'
N
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-111 REMOVE AND REPLACE SIDEWALK AREA.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RB STA 65+50
REMOVE AND REPLACE SIDEWALK AREA
PLAN AND SECTION
SITE LOCATION
66+00
66+20
66+40 66+6066+8067+00 67+20 67+40
67+60 67+80
68+00
68+20
68+40 68+60
0+60SD
SD SD
0+000+200+400+60
0+80 1+00 1+20 1+40 1+60 1+80 2+002+20
100-YEAR FLOOD EXTENTS
EXCAVATION LIMIT
35
4034
36
37
38
39
35
3334
36
37
35403637
3
839414
2 3535353535
403
2
5
2
4
4
4
5
6
36
35
3232
33
34
1
10
EXISTING USACE
RIGHT BANK ALIGNMENT
100' FROM LOGAN
AVENUE BRIDGE
B
C-113
3
4
1
1
9
A
C-113
C
C-113
7
R35'
14
10"
CONSTRUCTION ALIGNMENT
ALONG RIVERWARD FACE
OF FLOODWALL
EXISTING BUILDING FOOTING
EXISTING
BUILDING
FOOTING
RENTON SENIOR ACTIVITY CENTER
CEDAR RIVER TRAIL
FLAGPOLE LIGHTING
TO BE ADJUSTED AS
NEEDED
STA 1+48.20
STA 0+73.0215
STA 1+10.0015
15
STA 0+33.97
STA 0+42.81
COORDINATE TABLE
POINT
1
2
3
4
5
NORTHING
180378.58
180380.51
180381.02
180370.30
180316.05
EASTING
1300433.25
1300467.17
1300475.99
1300503.24
1300555.29
DESCRIPTION
BEGIN CONSTRUCTION
BEGIN FLOODWALL (RIVERWARD FACE)
FLOODWALL PC (RIVERWARD FACE)
FLOODWALL PT (RIVERWARD FACE)
END FLOODWALL (RIVERWARD FACE) / END CONSTRUCTION
9
10
CONSTRUCTION NOTES
1.SHORE TO PROTECT ADJACENT CONCRETE AND SENIOR ACTIVITIES
CENTER BUILDING.
2.EMBED FLOODWALL 5' MINIMUM INTO EXISTING HILL.
3.PROTECT EXISTING 12" HIGH PRESSURE WATER MAIN (BOEING).
CONTRACTOR TO VERIFY IN FIELD.
4.PROTECT EXISTING TREES. SEE CONTRACT SPECIFICATION SECTION
8-02.3(1)A.
5.SEED, FERTILIZE, AND MULCH AND PLACE TOPSOIL (WSDOT TYPE B) AS
SHOWN ON SHEET L-07.
6.REMOVE AND RESET EXISTING FLAGPOLE, PLAQUE, AND FOUNDATION IN
EXISTING LOCATION.
7.REMOVE EXISTING SHRUB. SEE SHEET L-03 FOR REPLACEMENT.
8.BACKFILL SHALL BE LEVEE EMBANKMENT FILL IN ACCORDANCE WITH
CONTRACT SPECIFICATION SECTION 2-03.
9.REINFORCED CONCRETE FLOODWALL TYPE 3. SEE DETAIL 1, SHEET C-113.
10.PROTECT EXISTING STORM AND IRRIGATION LINES.
11.MATCH EXISTING GROUND.
12.MATCH TOP OF FLOODWALL ELEVATION.
13.3H:1V FILL SLOPE ON EITHER SIDE OF FLOODWALL.
14.TRENCH DRAIN TO COLLECT ROOF DRAINAGE. SEE SECTIONS ON
FOLLOWING SHEET.
15.EXPANSION JOINT. DETAIL TBD @ 100% DESIGN.
9
10
11
12
13
14
2
3
4
5
1
6
7
8
15
30
35
40
30
35
40
0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+50
1.5
1
2' MINIMUM
FREEBOARD
3' MINIMUM
FREEBOARD
SENIOR ACTIVITIES CENTER
100' FROM LOGAN
AVENUE BRIDGE
100 YEAR WSE
EXST
GROUND
EXCAVATION LIMIT
FLOODWALL
FOOTING
FLOODWALL FOOTING KEY
EXST BERM BEHIND WALL 2' MIN.
EXST
CONCRETE WALL
5 EXST CONCRETE FOUNTAIN EXST CONCRETE WALL
EXST CONCRETE PAVEMENT
13
TOP OF EMBANKMENT FILL
MATCH EG 37.8'±
FG 37.3' MIN
FG 35.7'±
CONCRETE FLOODWALL
T/W 37.3' MIN
ENTIRE LENGTH
5
2
8
2
11
1
912
11
FREEBOARD
FREEBOARD
FLOODWALL PLAN
SCALE: 1" = 10'
0
SCALE:
5 10 20
1" = 10' ON 22X34 SHEETN PLANTING NOTES
1.SEE SHEET L-06 FOR PLANTING NOTES.
KEY MAP
SCALE: 1" = 1000'
N
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-113 RAISE LEVEE EMBANKMENT WITH FLOODWALL.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RB STA 65+90 TO 68+50
RAISE LEVEE EMBANKMENT WITH FLOODWALL
PLAN AND PROFILE
SITE LOCATION
FLOODWALL PROFILE
SCALE: HORIZ: 1" = 10' VERT: 1" = 2'
25
30
35
40
45
25
30
35
40
45
0 5 10 150-5-10-15
6.7'
5.2'
1.5'
EXCAVATION LIMIT
EXISTING
GROUND
2' MIN.
1.5
1
3' FREEBOARD
100 YEAR WSE
GRAVEL FILLED
TRENCH DRAIN WITH
6" PERFORATED PIPE
1.9'
MIN 1.0' COVER
REINFORCED CONCRETE
FLOODWALL TYPE 3
T/W 37.3'±
SEE DETAIL 1, THIS SHEET
FOOTING KEY
BOTTOM OF BUILDING FOOTING
EL 33.8'±
RENTON
SENIOR
ACTIVITY
CENTER
1'-6"0'-7 1/2"25
30
35
40
45
25
30
35
40
45
0 5 10 150-5-10-15
EXCAVATION LIMIT
EXISTING
GROUND
8.7'
2' MIN.
1.5
1
4.5' OVERHANG
RENTON
SENIOR
ACTIVITY
CENTER
8.2'
6.7'
1.5'
2' FREEBOARD
100 YEAR WSE
3.3'
REINFORCED CONCRETE
FLOODWALL TYPE 3
T/W 37.3'±
SEE DETAIL 1, THIS SHEET
FOOTING KEY
BOTTOM OF BUILDING FOOTING
EL 33.8'±
1'-6"0'-7 1/2"GRAVEL FILLED
TRENCH DRAIN WITH
6" PERFORATED PIPE
25
30
35
40
45
25
30
35
40
45
0 5 10 150-5-10-15
8.1'
6.6'
1.5'
EXCAVATION LIMIT
EXISTING
GROUND
1.5
1
2' FREEBOARD
100 YEAR WSE
4.5' OVERHANG
8.5'
2' MIN.
RENTON
SENIOR
ACTIVITY
CENTER PROPOSED FLOODWALL
T/W 37.3'±
EL 33.28'
EL 32.28'
FOOTING KEY
EL 31.28'
BOTTOM OF BUILDING FOOTING
EL 33.75'
1'-6"0'-7 1/2"1'-0"
MIN5'-0"10"4'-0"1'-0"4'-0"
2"
3/4" CHAMFER (TYP)
#5@9" O.C. EACH WAY #5@12" O.C. EACH
WAY, EACH FACE
#5 TIE @12" O.C.
2-#5 BARS
FINISHED
GRADE
1'-0"1'-6"
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: \\tt.local\wtr\WNW.Seattle\Projects\T35277 - Cedar River Levee Certification\04 CAD\Phase III\Sheet Files\C-113 RAISE LEVEE EMBANKMENT WITH FLOODWALL.dwgCITY OF
RENTON
Public Works Department
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:CEDAR RIVER LEVEES IMPROVEMENTSCEDAR RIVER LEVEE IMPROVEMENTS SWP-27-3708
AS NOTED
39
PGS, INC.
AB/SH/MH
SH/IL
KA
CP
www.tetratech.com
PHONE: 206.728.9655 FAX: 206.728.9670
SEATTLE WASHINGTON 98101
1420 FIFTH AVENUE, SUITE 650
75% SUBMITTAL - NOT FOR CONSTRUCTION
CALL TWO DAYS
PRIOR TO DIG
or 1-800-424-5555
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCH
AT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY
DATUM
RB STA 65+90 TO 68+50
RAISE LEVEE EMBANKMENT WITH FLOODWALL
SECTIONS AND DETAILS
FLOODWALL SECTION AT CORNERA
C-112 SCALE: HORIZ: 1" = 3' VERT: 1" = 3' ON 22X34 SHEET
FLOODWALL SECTION MIDDLEB
C-112 SCALE: HORIZ: 1" = 3' VERT: 1" = 3'
FLOODWALL SECTION BY DOORC
C-112 SCALE: HORIZ: 1" = 3' VERT: 1" = 3'
REINFORCED CONCRETE
FLOODWALL TYPE 3 DETAIL
SCALE: NTS1