Loading...
HomeMy WebLinkAboutWater Revision 2-signed.pdf26.28 T25.28 BData/Power26.34T24.32B28.89T26.45B25.45T24.50BCURB8'011'0"5'0"Gas requiires TOP of 10"Water to have a MIN of 1.25 Top of water needs to be 24.03 MIN.Vertical Concrete Dead-man with Megalugs and Shacklerodsat the 45* fittingVertical Concrete Dead-man with Megalugs and Shacklerodsat the 45* fitting23.3218.3223.3218.32WATER UTILITY ABDOUL GAFOUR 11/4/22 20 25 30 35 20 25 30 35 8" STORM** BOT 28.12 8" STORM** TOP 27.00 24" CPEP STORM TOP 28.23 FG 31.465+50FG 31.77FG 31.926+00FG 32.54FG 33.206+50FG 33.08FG 32.717+00FG 32.35FG 31.947+50FG 31.84FG 32.06DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 2.0' OF COVER AND MAXIMUM 5.0' OF COVER 3.12' PROPOSED ROW DEDICATION 1.5' MIN 15 LF 10" DIP CL 52 1.5' MIN *P(UG) - APPROXIMATE EXISTING UNDERGROUND POWER PROPOSED GRADE AT WATER ℄EXISTING GRADE AT WATER ℄ STA: 7+71.77 1 - 10" 90° BEND (MJ x MJ) 1 - THRUST BLOCK 18 LF 10" DIP CL 52 127 LF 10" DIP CL 5 2 VB #1 VB #2 STA: 5+00.00 CONNECT TO EXISTING WATER MAIN (BY CITY FORCES) PER COR STD PLAN 300.1 1 - 18" x 10" TAPPING TEE (MJ x FL) 1 - 10" TAPPING GATE VALVE (FL x MJ) 1 - THRUST BLOCK 2.28' 4 LF 10" DIP CL 52 STA: 6+44.70 1 - 10" 11.25° BEND (MJ x MJ) 1 - THRUST BLOCK 127 LF 10" DIP CL 5 2 STA: 7+87.02 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (FL x MJ) 1 - 10" GATE VALVE (FL x MJ) 1 - 10" ADAPTER (FL x MJ) 1 - THRUST BLOCK PROPOSED SEWER 14 LF 10" DIP CL 52 STA: 5+03.00 1 - 10" 22.5° BEND (MJ x MJ) 1 - THRUST BLOCK STA: 5+35.31 1 - 10" 45° BEND (MJ x MJ) 1 - THRUST BLOCK 6" DI STORM BOT 29.80 ETHAFOAM PAD 10 15 20 25 30 35 10 15 20 25 30 35 FG 32.048+50FG 31.79FG 31.729+00FG 32.09FG 32.459+50FG 31.68FG 30.7810+00FG 30.41FG 30.1110+50FG FG1.51' 5.67' DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 3.0' OF COVER AND MAXIMUM 6.0' OF COVER 5.14' 1.5' MIN 6.50' PROPOSED ROW DEDICATION APPROX. LOCATION OF EXISTING GAS PROPOSED STORM** PROPOSED FIRE PIPE 1.61' PROPOSED STORM** EXISTING GRADE AT WATER ℄ PROPOSED GRADE AT WATER ℄ PROPOSED GRADE AT WATER ℄ EXISTING GRADE AT WATER ℄ STA: 9+01.47 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F Lx MJ) 1 - 10" FL x MJ ADAPTER 1 - THRUST BLOCK STA: 9+08.47 1 - 10" x 6" TEE (FL xFL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F L x MJ) 1 - 10" FL x MJ ADAPTER 1 - THRUST BLOCK STA: 8+12.97 1- 10" 11.25° BEND (MJ x MJ) 1 - THRUST BLOCK 1.50' 7 LF 10" DIP CL 52 STA: 10+63.70 CONNECT TO EXISTING WATER MAIN CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 1 - 12" x 10" TEE (FL x FL) 1 - 10" GATE VALVE (FL x MJ) 2 - 12" GATE VALVE (FL x MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 1 - THRUST BLOCK INSTALL 84 LF OF 10" D.I. RESTRAINED JOINT WATER MAIN INSIDE OF 20-INCH STEEL CASING 31 LF 10" DIP CL 52 39 LF 10" DIP CL 52 LOCATION OF DATA POWER JOINT UTILITY TRENCH STA: 10+61.60 1- 10" 45° VERTICAL BEND (RJ X RJ) 1 - THRUST BLOCK STA: 10+60.10 1-10" 45° VERTICAL BEND (RJ x RJ) 1- VERTICAL CONCRETE DEAD-MAN THRUST BLOCKSTA: 10+26.18 1-10" 45° VERTICAL BEND (RJ x RJ) 1- VERTICAL CONCRETE DEAD-MAN THRUST BLOCK STA: 10+24.63 1 - 3" WET TAP PER COR STD PLAN 300.1 1-10" 45° VERTICAL BEND (RJ x RJ) 1 - VERTICAL CONCRETE DEAD-MAN THRUST BLOCK VERTICAL BEND TABLE VB # VB #1 VB #2 STATION DESCRIPTION STA: 5+04.17 1-10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK STA: 5+17.73 1- 10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4200WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMITWATERSHED APARTMENTSbelow.Know what'sCallbefore you dig. R Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors T A C O M A 2215 North 30th Street, Suite 300, Tacoma, WA 98403253.383.2422TEL S E A T T L E 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101206.267.2425TEL C21005115 LUA21-000239PR21-000258WATERSHED APARTMENTS1 SCALE: 1" = 20' H 1" = 10' V PROFILE 1 2 SCALE: 1" = 20' H 1" = 10' V PROFILE 2 2 C6.40 2 C6.40 WATER PROFILE AND NOTES APPROX. LOCATION OF EXISTING POWERIN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. **STORM DRAIN AT CROSSING SHALL BE CL 52 DI. CENTER OF WATER MAIN PIPE AND STORM DRAIN PIPE SHALL BE CENTERED AT THE CROSSING POINT TO MAXIMIZE THE DISTANCE OF THE PIPE BELLS FROM THE CROSSING JOINT.W-420003WTRP-27-4200IN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. 46 03/07/2023 DEVELOPMENT ENGINEERING JChavez 03/07/2023