Loading...
HomeMy WebLinkAboutKiddie Research Light pole base 03132023.pdfEdward C. Robison, PE 14 DEC. 2022 Rev’d 31 JAN 2023 Rev’d 13 March 2023 Oak Hills Construction 901 Algona Blvd. North, Suite A Algona, WA 98001 SUBJ: KIDDIE RESEARCH DAYCARE 1025 N 36TH ST, RENTON, WA LIGHT POST BASES The project requires the installation of light posts on concrete bases. The project plans don’t specify the depth of the post bases. The design is based on compliance with the applicable requirements of the 2018 International Building Code as adopted by Washington State and the AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals Fifth Edition. Based on the the attached design calculations the the recommended post base size is: For 40’ poles: Pier depth = 3’-3” x 3’-6” diameter: SF = 3.2 (requires plan variance) Pier depth = 5’-0” x 3’-0” diameter: SF = 10.5 For 18’ poles: Pier depth = 3’-0” x 2’-6” diameter: SF = 6.8 (requires plan variance) Pier depth = 4’-0” x 2’-6” diameter: SF = 14.0 Those depths that are less than the minimum required by the City of Renton and thus require a variance approval. As shown these footing sizes will provide a safety factor greater than 2.5 as required by the AASHTO manual. Calculations Page Loading 2 Soil parameters used in design 3 Depth calculations 3 - 4 Safety factors 5 If you have any questions please e-mail me at elrobison@narrows.com. Edward Robison, P.E. 10012 Creviston DR NW 253-858-0855 Gig Harbor, WA 98329 fax 253-858-0856 email: elrobison@narrows.comSTATEOFWASHIN G T ON29129REGIST ERE D Sealed 13 March 2023 Kiddie Research Light Post Base Page ! of !2 5 DESIGN LOADING: Luminaire weight = 100# Arm length 10’ Ice loads = 3 psf on surface Wind loads: AASHTO F = qhGCfAs V = 100mph for location Kz = 1.04 AASHTO Table 3-5 40’ height G = 1.3 Cd = 0.5 AASHTO Table 3-6 for generally round surfaces vpz = 0.00256KzGV2IrCd = 0.00256*1.04*1.3*1002*1.0*0.5 = 17.3 psf Total wind load On post: 12” average diameter Wp = 1’*40’*17.3 = 692# on luminaire Conic shape Wl = 2’*2’*(2/3)*17.3 = 46.1# on arm: Wa = 0.5’*10’*17.3 = 86.5# Combined moment on the post base: Group Load: I DL II DL + W III DL + Ice + 1/2W IV Fatigue - not applicable for this application M = D + W M = (100*10’) + 692*20’+(64.1+86.5)*35’ 20,111’# V = 692+64.1+86.5 = 843# As ice load is so small relative to wind it is trivial case. Edward C. Robison, P.E. 10012 Creviston DR NW 253-858-0855 Gig Harbor, WA 98329 fax 253-858-0856 email: elrobison@narrows.com SHEET NO.: OF REVISION DATE BY DESIGNED BY: DRAWN BY: APPROVED BY: ISSUE DATE: 02-26-2020 JOB NO.: TENW #6002 DRAWING FILE NO.: DRAWING NO.: DMA DMA EMS 2 KIDDIE RESEARCH DAYCARETENW Transportation Planning | Design | Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 Transportation Engineering NorthWest Project Contact: Danielle Allen , E.I.T. Phone: 425-250-0584 KIDDIE RESEARCH, LLC 1025 N 36TH ST.RENTON, WA 98056KIDZRESEARCH@HOTMAIL.COMYING CHIAO CHEN 02-26-2020 ILLUMINATION PLAN 2 IL-02 T-411101TRO-41-4111 Kiddie Research Light Post Base Page ! of !3 5 FOUNDATION DESIGN: 3’ DIAMETER ROUND PIER Soil strength based on geotechnical report for the project from Mud Bay Geotechnical Services, LLC: Geotechnical Engineering Design Report: 3123 Sunset Blvd NE Renton, WA prepared by Carson AuYeung and Livia Chen, sealed by Chris J. Heathman, P.E. on 03/18/2019. Allowable bearing pressure based on section 4.2.1 = 3,500 psf Lateral resistance on the pier based on the ultimate passive earth pressure: Kpult = 1,185 psf Reduce by safety factor of 2.5 per AASHTO manual (1.5 specified in report). Kpdes = 1,185/(2.5) = 474 psf (use 590 psf) Cohesive strength = 0 Check required pier depth based on AASHTO formula C13-7 L3- 2VFL/(KpγD) - 2MF/(KpγD) = 0 Use iterative process to find L to satisfy the equation using Kpγ = 474 psf Edward C. Robison, P.E. 10012 Creviston DR NW 253-858-0855 Gig Harbor, WA 98329 fax 253-858-0856 email: elrobison@narrows.com Kiddie Research Light Post Base Page ! of !4 5 Minimum pier length as required by the City of Renton Standard Detail is 5’ - requires variance CHECK FOR 18’ TALL POSTS: Loading: Wp = 1’*18’*17.3 = 311# M = (100*10’) + 311*9’+(64.1+86.5)*16’ = 6,161’# V = 311+64.1+86.5 = 462# Minimum pier length as required by the City of Renton Standard Detail is 4’ MF VF Kpγ = Diameter 20111 843 474 3.5 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 1 1 1.016 24.245 -24.261 2 8 2.033 24.245 -18.277 3 27 3.049 24.245 -0.294 3.125 30.517578125 3.176 24.245 3.097 3.25 34.328125 3.303 24.245 6.781 5 125 5.081 24.245 95.674 MF VF Kpγ = Diameter 6161 462 474 2.5 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 1 1 0.780 10.398 -10.178 2 8 1.559 10.398 -3.958 2.25 11.390625 1.754 10.398 -0.762 2.333 12.698260037 1.819 10.398 0.481 2.4167 14.114588665463 1.884 10.398 1.832 3 27 2.339 10.398 14.262 Edward C. Robison, P.E. 10012 Creviston DR NW 253-858-0855 Gig Harbor, WA 98329 fax 253-858-0856 email: elrobison@narrows.com Kiddie Research Light Post Base Page ! of !5 5 Determine maximum load for revised base size: Find by trial and error: 35’ poles SF = 2.5*25730/20111 = 3.2 (42” diameter x 3’3” depth) SF = 2.5*84660/20111 = 10.5 (36” diameter x 5’0” depth) 18’ pole SF = 2.5*16660/6161 = 6.8 (3’ diameter x 3’ depth) SF = 2.5*34548/6161 = 14.0 (3’ diameter x 3’ depth) MF VF Kpγ = Diameter 25730 843 474 3.5 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 3.25 34.328125 3.303 31.019 0.007 MF VF Kpγ = Diameter 84660 843 474 3 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 5 125 5.928 119.072 -0.000 MF VF Kpγ = Diameter 16660 843 474 3 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 3 27 3.557 23.432 0.011 MF VF Kpγ = Diameter 34548 843 474 2.5 Trial length L3 2VFL/(KpγD)2MF/(KpγD)∆ 4 64 5.691 58.309 0.000 Edward C. Robison, P.E. 10012 Creviston DR NW 253-858-0855 Gig Harbor, WA 98329 fax 253-858-0856 email: elrobison@narrows.com