Loading...
HomeMy WebLinkAboutChange Order - 29            CAG-20-065, CO #29-23 Approved by Cheryl Beyer via 2/13/2023 email                   NE 10TH STDUVALL AVENUE NE5L091PLANSCALE IN FEET0204041722NUMBERBY APP.REVISION DESCRIPTIONDRAWN BY:DESIGN BY:CHECK BY:PROJ MGR: FILE:PU2141779045-IL.dwgCITY OF RENTONBY:DATE:APPROVED FOR CONSTRUCTION___________________________________DATEDRAWING NO.PROJECT NO.FED AID NO.DATE: SHEET NO.OFSURVEYED:2141779045CMCFEB 202194DUVALL AVE NE1019 39TH AVENUE SE, SUITE 100PUYALLUP, WASHINGTON 98374T. 253.604.6600 F. 253.604.6799www.parametrix.comPUBLIC WORKS DEPARTMENTTRANSPORTATION DIVISIONCONFORMED SET02/22/2021E269MEKMEKMATCH LINE STA 908+00, SEE SHEET E3MATCH LINE STA 903+00, SEE ABOVEMATCH LINE STA 903+00, SEE BELOWMATCH LINE STA 898+50, SEE SHEET E1L0614L0714L0813L1013PLANSCALE IN FEET02040L1114L12DUVALL AVENUE NENE 9TH ST454EX SVCSC12212ELECTRICAL PLANSTA 898+50 TO STA 908+00SHEET 2 OF 1114511011111111102222899992121175C-LINEC-LINEELECTRICAL NOTES:CONSTRUCT DECORATIVE LUMINAIRE, POLE ANDFOUNDATION. SEE LUMINAIRE SCHEDULE ON SHEET E11FOR MORE DETAILS.INSTALL JUNCTION BOX WITH SLIP RESISTANT LID ATFINISHED GRADE IN SIDEWALK.INSTALL JUNCTION BOX WITH PAD AT APPROXIMATELOCATION SHOWN, PER COR STD PLAN 120.REMOVE EXISTING JUNCTION BOX AND REPLACE WITHJUNCTION BOX TYPE 2. REINSTALL CONDUIT AND WIREIN JUNCTION BOX. SEE WIRE SCHEDULE.INSTALL NEW CONDUIT INTO EXISTING JUNCTION BOX.REMOVE EXISTING LIGHT STANDARD, FOUNDATIONAND ADJACENT JUNCTION BOX. SALVAGE LIGHTSTANDARD TO CITY.EXISTING UTILITY POLE (PSE) AND LUMINAIRE TOREMAIN.EXISTING LUMINAIRE POLE (CITY) TO REMAIN.CONNECT NEW LIGHTING (CIRCUIT LTG1) IN EXISTINGSERVICE CABINET.REMOVE EXISTING SOLAR POWERED FLASHING BEACONASSEMBLY AND FOUNDATION. CONSTRUCT NEWFOUNDATION PER WSDOT STD PLAN J-21.10-04 WITHMODIFIED BOLT PATTERN TO MATCH EXISTING POLEAND REINSTALL SOLAR POWERED FLASHING BEACONASSEMBLY AT LOCATION SHOWN.PROVIDE TWO, 12 COUNT PATCH PANELS ANDETHERNET SWITCH FOR INSTALLATION IN EXISTINGCONTROLLER CABINET. SPLICE FIBER 1-12 OF THE BLUETUBE AND FIBER 13-24 OF THE ORANGE TUBE ANDINSTALL IN PATCH PANELS. COORDINATE WORK WITHCITY.SPLICE NEW STREET LIGHT WIRING TO EXISTINGILLUMINATION WIRING IN EXISTING JUNCTION BOX.REMOVE EXISTING LIGHT STANDARD AND FOUNDATION.SALVAGE LIGHT STANDARD TO CITY.1345791112141722CS2411111188GENERAL NOTES:1. THE LOCATION OF CONDUIT AND JUNCTION BOXES ARE SHOWN SCHEMATICALLY. FINAL LOCATIONSSHALL BE VERIFIED BY THE ENGINEER IN THE FIELD.2. UTILITY LOCATION PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.3. ALL CONDUCTORS FOR SIGNAL HEADS, PEDESTRIAN HEADS, PUSH BUTTONS AND STREET LIGHTS SHALL BELABELED IN EACH JUNCTION BOX.4. SIGNAL POLES AND FOUNDATIONS SHALL BE EQUIPPED WITH IDENTIFICATION TAGS PER STD PLAN 139.5. FOR SIGNAL SYSTEM COORDINATION WITH THE CITY OF RENTON, CONTRACTOR SHALL CALL CITYTRANSPORTATION MAINTENANCE DEPARTMENT SUPERVISOR ERIC CUTSHALL AT (425) 430-7423.6. SEE COR STD PLAN 135 FOR ADDITIONAL ELECTRICAL NOTES.ELECTRICAL LEGEND:JUNCTION BOXES (WSDOT TYPES 1, 2, 8)DECORATIVE ROADWAY POLE AND LUMINAIRESTREET LIGHTTYPE PS SIGNAL POLEPEDESTRIAN PUSH BUTTONSIGNAL POLESIGNAL POLE W/ LUMINAIREPEDESTRIAN SIGNAL HEADVEHICLE SIGNAL HEADEMERGENCY PRE-EMPTION DETECTORCONTROLLER CABINETSERVICE CABINETSMALL CABLE VAULTPOWER POLEFLASHING BEACON SIGN ASSEMBLYRADAR SPEED SIGNCONDUIT (SEE WIRE SCHEDULE)POLE IDENTIFIERCONDUIT/WIRE NOTESEE WIRE SCHEDULE ON SHEET E11ELECTRICAL NOTE###LIGHT STANDARD REMOVAL AND RELOCATION MEK 3/15/202203/15/20221241111E2-013123E2-012623         Coil up 1,000 LF of fiber in the FO vault for future to new signal at NE 10th E3-013123E3-012623         Leave 100’ of slack in the 72ct cable (do not cut) and continue to 10th & Duvall.Install a 72ct drop from the signal cabinet to the 25TA vault. Leave 50’ of slack in the vault. City crew will install a splice enclosure and splice the cables.Leave 100’ of cable where the run ends at 10th St. Leave 1,000 feet of cable at FO vault at Sta 911+25 LTE4-013123E4-012623         25-3031-3631-36Splicing note: N 1st & Wells 31-36 to TSC Hoquiam/Hazel 31-36 are existing splices. Do not remove.E5-013123E5-012623Leave 1000 feet of slack in the FO vault at Sta 911+25 LT         72ct drop to the signal cabinet72ct to 10th & Duvall72ct from NE corner of Sunset & Duvall100Leave 100’ of slack in the fiber vault. Do not cut the cable. Leave 50’ of slack in the fiber vaultLeave 100’ of cable where the run ends at 10th St. Leave 1,000 feet of cable at FO vault at Sta 911+25 LTE6-013123E6-012623         LUMINAIRE SCHEDULEPOLE #SERVICE CIRCUIT STATION OFFSET POLE AND FIXTUREPOLE IDNUMBERL01 SC122 LTG1 892+41.0 39.5' RTLED ROAD/120W/TYPE 3L02 SC122 LTG1 893+61.1 40.5' RTLED ROAD/120W/TYPE 3L03 SC122 LTG1 894+61.6 41.0' RTLED ROAD/120W/TYPE 3L04 SC122 LTG1 896+02.4 39.5' RTLED ROAD/120W/TYPE 3L05 SC122 LTG1 897+23.7 39.5' RTLED ROAD/120W/TYPE 3L06 SC122 LTG1 900+44.8 39.8' RTLED ROAD/120W/TYPE 3L07 SC122 LTG1 901+90.3 39.5' RTLED ROAD/120W/TYPE 3L08 SC122 LTG1 903+27.6 39.5' RTLED ROAD/120W/TYPE 3L09 SC354 EX 904+16.2 40.1' LTLED ROAD/120W/TYPE 3L10 SC122 LTG1 904+91.4 39.5' RTLED ROAD/120W/TYPE 3L11 SC354 EX 905+66.6 39.5' LTLED ROAD/120W/TYPE 3L12SC122 LTG1 899+55.0 39.5' RTLED ROAD/120W/TYPE 3L13 SC066 B 913+46.7 39.5' RTLED ROAD/120W/TYPE 3L14 SC066 B 914+66.7 39.5' RTLED ROAD/120W/TYPE 3L15 SC066B915+86.9 39.5' RTLED ROAD/120W/TYPE 3L16 SC066B917+06.8 39.5' RTLED ROAD/120W/TYPE 3L17SC066B918+25.9 39.5' RTLED ROAD/120W/TYPE 3L18 SC066B919+43.1 35.7' RTLED ROAD/120W/TYPE 3L19 SC066B920+81.3 39.5' LTLED ROAD/120W/TYPE 3L20 SC066B921+74.9 39.5' LTLED ROAD/120W/TYPE 3L21SC066 B 922+79.8 39.5' LTLED ROAD/120W/TYPE 3L22SC066 B 924+00.1 39.5' LTLED ROAD/120W/TYPE 3L23 SC066 B 925+17.1 39.5' LTLED ROAD/120W/TYPE 3L24SC066 B 926+21.2 39.5' LTLED ROAD/120W/TYPE 3L25 SC066 B 927+21.7 39.9' LTLED ROAD/120W/TYPE 3LUMINAIRE SCHEDULE NOTES:1. ALL POLES/LUMINAIRES SHALL BE ARTERIAL STREET DECORATIVE LUMINAIRE POLES, INCLUDING; POLE, ARM, FIXTURE,BASE PLATE AND ANCHOR BOLT DETAILS PER CITY OF RENTON STANDARD PLAN 117.1, DATED 5/19/15 (NOT CURRENTVERSION-SEE DETAIL SHEET IN APPENDIX IN SPECIAL PROVISIONS). PEDESTRIAN LUMINAIRE AT 14' MOUNTING HEIGHTIS NOT REQUIRED. ARM LENGTH SHALL BE 10 FT AND MOUNTING HEIGHT SHALL BE 35 FT. FOUNDATION DEPTH SHALL BE5.0 FT.2. LUMINAIRE ARM AND MOUNTING BRACKET DETAILS PER CITY OF RENTON STANDARD PLAN 117.3.3. ALL POLE ARMS SHALL BE ORIENTED PERPENDICULAR TO THE FLOW LINE OF THE ADJACENT CURB.4. SEE TABLES 1 AND 2, SHEET E10 FOR FOUNDATION INFORMATION.5. OFFSET SHOWN IS TO CENTER OF POLE.XXNUMBERBY APP.REVISION DESCRIPTIONDRAWN BY:DESIGN BY:CHECK BY:PROJ MGR: FILE:PU2141779045-IL.dwgCITY OF RENTONBY:DATE:APPROVED FOR CONSTRUCTION___________________________________DATEDRAWING NO.PROJECT NO.FED AID NO.DATE: SHEET NO.OFSURVEYED:2141779045CMCFEB 202194DUVALL AVE NE1019 39TH AVENUE SE, SUITE 100PUYALLUP, WASHINGTON 98374T. 253.604.6600 F. 253.604.6799www.parametrix.comPUBLIC WORKS DEPARTMENTTRANSPORTATION DIVISIONCONFORMED SET02/22/2021E1178MEKMEKTRAFFIC SIGNAL PLAN AND SCHEDULESSHEET 11 OF 11WIRE SCHEDULERUN NO. CONDUITTYPEVEH.HEADPED.HEADPPB EVPILLUMINATION FLASHINGBEACONFIBERSERVICEPOWERSIGNALPOWERSPARE NOTES5C 5C 2C/S 3C/S SVC SC354 SVC SC122 SVC SC06672SMFOEX CIRCUIT CIRCUIT LTG1 CIRCUIT A CIRCUIT B02"112"2 X #822"2 X #832"2 X #842"2 X #852"2 X #8 2 X #86EX 2" 2 X #87EX 3"1INCL. EX 24CT & 36CT SMFO8EX 2" 2 X #89EX 2"1(1)102"111 EX 4"1 INCL. EX 24CT & 36CT SMFO12 EX 2" 213EX 2" 1 114 EX 2" 2 1 1152" 222162" 2 1173"422118 EX 3"3 X #2(4)192"2 X #820EX 2"121EX 2"2 X #8222"1123EX 2"1 INCL. EX 24CT & 36CT SMFO242"2 X #8 2 X #8252"2 X #8 2 X #8 2 X #8WIRE SCHEDULE NOTES:(1) EXISTING CONDUIT MAY CONTAIN WIRES TO REMAIN. SIZES AND QUANTITIES UNKNOWN.(2) ALL CONDUIT CONTAINING WIRE SHALL INCLUDE A #8 GROUND WIRE NOT SHOWN IN THE SCHEDULE.(3) ALL CONDUIT SHALL BE SCHEDULE 40 PVC APART FROM STREET CROSSINGS, WHICH SHALL BE SCHEDULE 80 PVC.(4) COORDINATE POWER CONNECTION TO SERVICE WITH PUGET SOUND ENERGY.CSLIGHT STANDARD REMOVAL AND RELOCATION MEK 3/15/202203/15/202211E11-013123E11-012623