Loading...
HomeMy WebLinkAboutR-4220261. FOR WIRE SIZES NO. 14, 12, AND 10, ALL CONNECTIONS IN VALVE BOXES ONLY. 2. INSTALL SPEARS DS-100 DRI-SPLICE CONNECTORS WITH DS-300 SEALANT. O STEP 1 SLIP BASE SOCKET OVER END OF J WIRES Ltj��� UI STRIP WIRES APPROX. 1" FROM ENDS - z TWIST ENDS TOGETHER STEP 2 APPLY SEALER TO OUTSIDE OF SEALING PLUG - FILL CAVITY WITH SEALER ry PUT CRIMP SLEEVE OVER WIRE ENDS - CRIMP SLEEVE AND CUT OFF EXCESS WIRE ^Q I..L PULL BASE SOCKET OVER WIRE END STEP 3 AS FAR AS POSSIBLE 7251 PUSH SEALING PLUG INTO BASE SOCKET r STEP 4 PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONNECTION U) DRI-SPLICE TYPE WIRE CONNECTOR O IRRIGATION WIRE CONNECTION 1 SCALE: N.T.S. PERMANENTLY NOTCH OR OTHERWISE MARK HARDSCAPE WHERE SLEEVE OCCURS HARDSCAPE, TYPICAL FINISHED 12" MIN. GRADE 12" MIN. FOR a�a LATERALS 18" MIN. FOR MAINLINES SCH. 40 PVC BACKFILL WITHIN 3" OF SLEEVE SHALL BE PIPE SLEEVE, FREE OF ROCKS AND STONES LARGER SIZE NOTED ON THAN 1/4" DIA. IF ROCK CANNOT BE PLANS REMOVED FROM EXCAVATED SOIL, PROVIDE CLEAN SAND BEDDING. 1 MAINLINE AND LATERAL PIPE SLEEVING SCALE: N.T.S. NOTES: 1. ALL WIRES TO BE INSTALLED PER LOCAL CODE. TAPE AND BUNDLE WIRES EVERY 7'. PROVIDE EXPANSION COIL AT EACH WIRE CONNECTION IN VALVE BOX (WRAP AROUND 1/2" 0 PIPE 15 TIMES). 2. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS ADJACENT UNDISTURBED SOIL. 3. ALL THREADED PVC JOINTS SHALL BE WRAPPED WITH TEFLON TAPE. SCH 80 FEMALE ADAPTER REINFORCED PLASTIC AND NIPPLE ACCESS BOX W/ SCH 80 PVC THREADED COVER UNION AND FITTINGS, TYP. %2" REVEAL SURFACE MULCH PER PLANS WIRE CONNECTORS BRASS BALL VALVE BRICK FOR FOOTING, ONE AT EACH CORNER 17 CONTROL/ COMMON WIRES A1111111111tIII III- v vrn 6� U III III 0 00 - PVC LATERAL I � ELECTRIC REMOTE CONTROL VALVE (OR DRIP ZONE CONTROL KIT), SIZE —III AND MODEL AS NOTED ON PLANS SCH. MAINLINE PVC INE FITTING 12" DEEP (3/4" 0) GRAVEL SUMP 3 ELECTRIC REMOTE CONTROL VALVE SCALE: N.T.S. C! NOTES: 1. SELECT BACKFILL SHALL BE SAND OR SOIL FREE OF ROCKS AND STONES LARGER THAN 1/4" DIA. 2. BACKFILL MATERIAL SHALL BE WATERED IN AND COMPACTED TO DENSITY OF ADJACENT UNDISTURBED SOIL. FINISHED GRADE DETECTABLE MARKING TAPE 12" MIN. 3" MIN. ALL SIDES 8" 18" MIN. 6" MIN EXCAVATED SOIL, REPLACED AND PVC LATERAL/ COMPACTED SELECT BACKFILL DRIP SYSTEM HEADER PIPE LATERAL PIPE FINISHED GRADE DETECTABLE MAINLINE MARKING TAPE EXCAVATED SOIL, PVC MAINLINES REPLACED AND AND LOW COMPACTED SAND BEDDING VOLTAGE COMMON / CONTROL CONTROL WIRES WIRES MAINLINE PIPE 3"MIN. - SIDES AND TOP OF PIPE PIPE TRENCHING AND BACKFILL - MAINLINE, LATERALS, AND MARKING TAPE SCALE: N.T.S. �•. -'II III LOOP, BUNDLE, AND LABEL SPARE WIRES THAT ARE TO CONTINUE, AS OCCURS 1/2" WIRE CLOTH GOPHER PROTECTION SCREEN, WRAP 6" UP SIDES (2) 6x2x16 CONCRETE BLOCK CAPS, ONE ON EACH SIDE OF BOX 5 J BOX RECTANGULAR VALVE BOX AND COVER; HEAD BRAND "J BOX" ON LID WITH 2" HIGH LETTERS 1/2" REVEAL FINISHED GRADE SPARE WIRES THAT ARE TO TERMINATE AT THIS BOX: COIL 30" LENGTH AND I.D. TAG WIRES TO CONTROLLER PVC MAINLINE, SEE PLAN FOR DETAILS IRRIGATION WIRING JUNCTION BOX SCALE: N.T.S. TREE BUBBLER 6 1 SCALE: N.T.S. li i Ld NO. REVISION u- 10 BUBBLER PER LEGEND - 2 PER TREE O2 MULCH O3 FINISH GRADE/TOP OF MULCH O4 UV RADIATION RESISTANT 1/2-INCH PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) O5 1/2-INCH FEMALE NPT x 0.490-INCH BARB ELBOW O6 SWING PIPE, 12-INCH LENGTH PVC LATERAL PIPE 0 O8 1/2-INCH MALE NPT x .490-INCH BARB ELBOW O9 SCH 40 TEE OR ELL 10 EDGE OF ROOTBALL 11 PVC LATERAL LINE - 3/4" SURVEYED: DESIGNED: DRAWN: CHECKED: A P P R I APPROVED: SUBSURFACE DRIPLINE CONNECTION SCALE: N.T.S. FLUSH VALVE SCALE: N.T.S. DRIPLINE LAYOUT SCALE: N.T.S. SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 10 TOP OF MULCH 20 FINISH GRADE O3 DRIP LINE PER PLAN 40 INSERT TEE OR ELBOW O5 SCH. 80 PVC NIPPLE (LINE SIZE) OSCH. 40 PVC TEE (SST) OSCH. 40 PVC SUPPLY HEADER (SIZE PER PLAN) 10" ROUND PLASTIC VALVE BOX OWITH LOCKABLE LID, "CARSON" OR APPROVED EQUAL FINISH GRADE - TOP OF VALVE BOX TO O2 BE 2" ABOVE FINISH GRADE IN PLANTER AREAS O3 DRIP EXHAUST HEADER OBALL VALVE, LINE SIZE 3' COILED LENGTH OF LINE OSIZE FLEX HOSE. SOLVENT WELD TO VALVE 60 RED BRICK TYPICAL, 3 REQUIRED O7 6" DEEP LAYER OF PEA GRAVEL FLUSH VALVE `0 SCH. 40 PVC EXHAUST HEADER 43 SCH. 40 PVC TEE OR ELL 4 COMPRESSION ADAPTER DRIP LINE AIR RELIEF VALVE AT HIGH POINT OF SYSTEM (WHEN INDICATED ON PLANS) �7 SCH. 40 PVC SUPPLY HEADER CONTROL VALVE TREE ROOT BALL (WHERE OCCURS IN DRIP AREA) 10111.RAINBIRD PC-07 EMITTERS (3) OR EQUAL, WITH DIFFUSER CAPS, INSERTED IN DRIP LINE AND GENERALLY SPACED EVENLY AROUND TREE NEAR EDGES OF ROOT BALL (WHERE OCCURS) NOTE: SET DRIP LINES 3"-6" AWAY FROM HARDSCAPE CITY OF RFNTON Planning/Building/Public Works Dept. U Q J `gNDSC O IN COMPLIANCE WITH CITY OF RENTON STANDARDS i f V z 600 SW 10TH PARKING LOT IRRIGATION DETAILS DATE: 04/08/2022 FlELDBOOK: PAGE: DRAWING NO: ) L-503 O SHEET: ---- OF: 22 O