HomeMy WebLinkAboutMFP23001352.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP23001352
IVR Number: 23001352
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:03/14/2023Application Date:1494500030Parcel Number: 4621 NE SUNSET BLVD
Permit Type:03/28/2023Issue Date:Franchise
Permit Work Class:03/27/2024Expiration Date:Major Utility
Job Number: JB0001247483Franchise Type:Cable
Description: PRE CONSTRUCTION MEETING REQUIRED
Comcast JB0001247483 TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075] OVERLASH (1) 96CT FIBER ON
EXISTING AERIAL STRAND. TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]. TIE IN TO EXISTING SPLICE CASE
[KV07S.7A] OVERLASH (2) 96CT FIBER ON EXISTING AERIAL STRAND. TIE IN TO EXISTING SPLICE CASE
[SP.WAKV.0951]. TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]. PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052. PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT. POTHOLE ALL
EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
David Standring
Cannon Construction LLC
406 Porter Way
Milton, WA 98354
ApplicantX
David Standring
Cannon Construction LLC
406 Porter Way
Milton, WA 98354
Contact
Jessamin Santos
Comcast
410 Valley Ave NW, Suite 12 Bldg C
Puyallup, WA 98371
B: (206) 401-2188Contact
David Standring
Cannon Construction LLC
406 Porter Way
Milton, WA 98354
Contractor
Business License Number: 20838Construction Contractor: CANNOCL791JK
Jessamin Santos
Comcast
410 Valley Ave NW, Suite 12 Bldg C
Puyallup, WA 98371
B: (206) 401-2188Emergency
Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Comcast Cable Communications Management
JB0001247483
Jessamin Santos
408-644-1694
jessamin_santos@comcast.com
4621 NE SUNSET BLVD RENTON, WA 98059 ALBERTSONS COMPANIES, INC
- PROOF & PULL (1) 96CT FIBER FROM SP.0042WAKV TO SP.WABV.0052 - PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT
Cannon Construction LLC - David Standring 253-922-2787
601590363 20838
03/14/2023
MFP23001352
Scott Warlick
RESTORATION PER CITY OF RENTON STANDARDS
3/28/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2.The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
-Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
98371
JB0001247483
4621 NE SUNSET BLVD RENTON, WA 98059
Monday Friday 8:00am 3:00pm
Cannon
Jessamin Santos 408-644-1694
410 Valley Ave NW, Suite 12, Bldg C Puyallup
- PROOF & PULL (1) 96CT FIBER FROM SP.0042WAKV TO SP.WABV.0052 - PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT
MFP23001352
Scott Warlick CED 3/28/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
David Standring, Permitting Coordinator
03/14/2023
TRAFFIC CONTROL NOTES:
1. The designed traffic controls contained within this TCP will not be implemented until approved by the public authority having
jurisdiction
2. The contractor is advised that all lane closures shall be kept to a minimum. Local jurisdictions will approve only those lane and
roadway closures determined to be necessary for the contractor to accomplish a specific task. No lane or roadway closures will
be permitted without prior approvals.
3. The contractor shall keep all traffic lanes and shoulders clear of equipment and materials during non-working hours. Equipment
and materials shall not be stored on the streets. The contractor's employees and agents shall not park private vehicles along the
roadway or median.
4. All traffic control setups, sign spacing, and procedures will conform to the specifications stated in the federal manual on uniform
traffic control devices (m.u.t.c.d).
5. Cities and various municipalities may have also adopted specialized guidelines for traffic control within their jurisdiction. It is the
responsibility of the on-site traffic control personnel to verify if any special conditions exist.
6. Traffic control equipment shall maintain a minimum 15' clearance from railroad tracks.
7. Recessed steel plates shall be placed over open trench during non-work hours. W8-24 signs shall be placed as advanced warning
to vehicles.
8. Will coordinate with any businesses that will be affected by construction
9. Access to driveways must be maintained at all times.
10. No park signs to be placed 72 hours prior to construction.
11. Signs within roadway will be protected by channelization devices
12. All traffic control devices used for night work must be retroreflective
PEDESTRIAN & BICYCLE NOTES:
1. Bike lane traffic must be maintained with a minimum of 2' clearance throughout work area.
2. Pedestrian traffic must be maintained with a minimum of 4' clearance within crosswalk.
3. Pedestrian traffic must be maintained with a minimum of 4' clearance within sidewalk.
4. Flagger/spotter to direct and assist pedestrians around work area unless otherwise noted.
5. All work will stop while pedestrians are escorted through work zones
ADDITIONAL NOTES:
1. Contact property owner(s) 72 hours prior to start of work to alert owner(s) to possible driveway closures and alternate access
when applicable.
2. Contractor shall coordinate work hours with local school bell schedule. no traffic control equipment shall be placed until after
school is in session when applicable.
3. Notify fire station 72 hours prior to start of work. access for emergency vehicles shall be maintained at all times when applicable.
4. Contact transit authority 72 hours prior to start of work for temporary relocation of bus stop when applicable.FLAGGERSPOTTERLEGEND
Work Vehicle Truck Mounted Attenuator Work Area
Flagger Spotter Traffic Safety Cone/Drum
WT WT
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
TRAFFIC CONTROL NOTE
1 10
MFP23001352
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSUNSET BLVD NESUNSET BLVD NEB50'-100'XXXFLAGGER
B50'-100'WTXXXFLAGGER
R2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
2 10
MFP23001352
EOPEOPEOPEOPEOPEOP EOP EOP EOP
EOP EOP EOP EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSUNSET BLVD NESUNSET BLVD NENE 6TH CT
WTFLB50'-100'XXXXXXXXXXB50'-100'FAS
FLAGGER
FLAGGER
FLAGGER
R2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
3 10
MFP23001352
EOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOPFLFL
EOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOPEOP
EOPEOPEOPEOPEOPEOP
EOP
EOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOP EOPEOPEOPEOPEO
P
EOPEOPEOPEOPEOPEOP
EOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOPWTSUNSET BLVD
NE
BRONSON WAY NE
B50'-100'XXXXEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPXXXB50'-100'XXXXFASFAS FLAGGERFLAGGER
SUNSET BLVD NESUNSET BLVD NER2-1
R2-1
WT/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
4 10
MFP23001352
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP
EOP EOP EOP EOP EOP EOP
WT
TCP TO BE USED AT MULTIPLE
LOCATIONS:
- EDMONDS AVE NE
- FERNDALE CT NE
- FERNDALE PL NE
- HARRINGTON AVE NE
- INDEX PL NE
- KIRKLAND AVE NE
B50'-100'XXX
FLAGGER 6 DEVICE MIN
50'-100'XXXXXXXXXFLAGGER
FLAGGER
FLAGGER
*MULTIPLE LOCATIONS *MULTIPLE LOCATIONS
95.5391
PARKINGNO
FROM
TO
NAME OF FIRM 000-0000PHONE (CONTACT #)
TOW-AWAY AREA
R2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
5 10
MFP23001352
EOP
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EOP
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EOP
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EOP
WTB
50'-
1
0
0
'
X
X
X
6 D
E
V
I
C
E
M
I
N
50'-
1
0
0
'XXXFL
A
G
G
E
R
FL
A
G
G
E
R
NE
7
T
H
S
T
NE
7
T
H
S
T
146.7436
PA
R
K
I
N
G
NO
FR
O
M
TO
NAM
E
O
F
F
I
R
M
0
0
0
-
0
0
0
0
PH
O
N
E
(
C
O
N
T
A
C
T
#
)
TO
W
-
A
W
A
Y
A
R
E
A
R2-
1
R2-
1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
6 10
MFP23001352
EOP
E
O
P
EOPEOPEOPEOPEOPEOP
E
O
P
EOP
EOPEOPEOPEOPEOPWTEOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP EOP
EOPEOP
E
O
PEOP
E
O
P
BL/
3XX
X XSUNSET BL
V
D
NE SUNSET BL
V
D
NE
A
N
A
C
O
R
T
E
S
A
V
E
N
E
ANACORTES AVE NE6 DEVICE MIN50'-100'X11'MIN
R2-1R2-
1
100.0760 PARKINGNOFROMTONAME OF FIRM 000-0000PHONE (CONTACT #)TOW-AWAY AREAAN
A
C
O
R
T
E
S
A
V
E
N
E
R2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
7 10
MFP23001352
EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP
SUNSET BLVD NE
EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPXXXL
R2-1FAS
B
6 DEVICE MIN
50'-100'
WT
X
SUNSET BLVD NE
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
8 10
MFP23001352
WT
POLICE
OFFICER
B50'-100'XXXX
6 DEVICE MIN
50'-100'XXXXXXXXXFASR2-1
R2-1
SUNSET BLVD NE SUNSET BLVD NEANACORTES AVE NEANACORTES AVE NER2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
9 10
MFP23001352
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP EOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
POLICE
OFFICER
WT XXXXXXB
50'-10
0'
X
X
X
X FAS6 DEVI
C
E
MI
N
50'-10
0'XXXSUNS
E
T
B
L
V
D
N
E
SUNS
E
T
B
L
V
D
N
EDUVALL AVE NEDUVALL AVE NER2-1
R2-1
R2-1
R2-1
/
PM CONTACT INFORMATION:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCChristopher White
(P): (253) 348-9733
(E): cwhite@teamcannon.comJB0001247483ALBERTSONS COMPANIES, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
03/10/2023
C.WHITE
D.DELEON
SHEET NAME
10 10
MFP23001352
PAGE 4
PAGE 5 PAGE 6
PAGE 7
PAGE 8
PROJECT MAP:
POLE INFORMATION:
POLE COUNT =
POLES THAT NEED PERMIT =
POLES THAT NEED MAKE READY =
TRANSMISSION =
DISTRIBUTION =
28
28
2
0
28
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
SITE ADDRESS:
4621 NE SUNSET BLVD
RENTON, WA 98059
CONTACTS:
CANNON COMPANIES
Christopher White - (253) 348-9733 - cwhite@teamcannon.com
COMCAST COMMUNICATION
Danny Cooley - (253)-215-7020 - Danny_Cooley@comcast.com
BUSINESS/JOB CONTACT
POC: SANDY RHINEHART - (425) 467-8584
SCOPE OF WORK:
JB0001247483
ALBERTSONS COMPANIES, INC
SHEET INDEX
1 -COVER
2 -GENERAL NOTES
3 -LEGEND
4-8 -CONSTRUCTION PLAN
9-10 -POLE DATA
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
- OVERLASH (1) 96CT FIBER ON EXISTING AERIAL STRAND.
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
- TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
- OVERLASH (2) 96CT FIBER ON EXISTING AERIAL STRAND.
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
- PROOF & PULL (1) 96CT FIBER FROM SP.0042WAKV TO SP.WABV.0052.
- PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT.
N
S
EW
*ALL FOOTAGES AND MATERIALS ARE ESTIMATEDBILL OF MATERIALS*:
NEW AERIAL =
OVERLASH =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
RISER =
TOTAL ROW FOOTAGE =
FT.
FT.
FT.
FT.
FT.
FT.
ROW FOOTAGES*:
NEW BUILDING PATHWAY =
EXISTING BUILDING PATHWAY =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
TOTAL SITE FOOTAGE =
FT.
FT.
FT.
FT.
FT.
SITE FOOTAGES*:
TOTAL PROJECT FOOTAGE = FT.
0
6,164
0
1,718
(0)0
7,882
0
0
0
0
0
7,882
FT + 20% STORAGE = FT96CT FIBER 7,882 9,458
Metro-E Wholesale
MFP23001352
This permit is for Major construction work in the ROW and will be billed at an additional
$158/HR for inspections. After hours and weekend work will be billed at $175/HR
RESTORATION PER CITY OF RENTON STANDARDS
Pre-Construction meeting required
STANDARD
1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO CONSTRUCTION.
THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS NECESSARY, TO DETERMINE
THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT THERE WILL BE INTERFERING UTILITIES AND
OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE
PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD. THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL
OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT
WORK IN SOME CASES PROPOSED PATH MAYBE IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES
NOT SHOWN ON THE PLANS WHICH MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL
TRAFFIC CONTROL, ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF
THESE OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES TO
PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES AND/OR UTILITY
RELOCATIONS DUE TO SAID CONFLICTS.
2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811
3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES.
4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEWATER,
AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES.
5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM.
6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO PREVENT ANY
HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE.
7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS.
8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED
TO NORMAL WORKING HOURS.
10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR WRITTEN
APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED.
11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT PROPERTIES
WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS OTHERWISE REQUIRED.
12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT,
UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE ONLY THOSE
LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A SPECIFIC TASK. NO LANE OR
ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS.
2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING NON-WORKING HOURS.
EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES AND AGENTS SHALL NOT PARK
PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN.
SITE PREPARATION
1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE EITHER
REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE.
2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE MATERIAL
(I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE).
3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
TRENCH EXCAVATION AND BACKFILL
1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL BACKFILL WITH
BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX 351 IS ACCEPTABLE IN ALL
LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN TRAFFIC-BEARING LOCATIONS.
2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
UTILITY DUCT
1. BURIED DUCT SHALL BE SCHEDULE 80 PVC OR EQUIVALENT, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36" WITH A
MINIMUM SLOPE OF 1/2 % TO VAULT.
2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED, PLUG ENDS OF
CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP CONDUITS CLEAR OF CONCRETE,
DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION.
3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL ROPE AND
PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE SIMPLEX COMPRESSION
PLUGS SEALING THE CONDUITS AROUND THE CABLE.
4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL ROPES AND
PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED.
CEMENT CONCRETE PAVEMENT
1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD SPECIFICATIONS OF
EACH JURISDICTION.
ASPHALT CONCRETE PAVEMENT
1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT CONCRETE
ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION.
GRAVEL AREAS
1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN ACCORDANCE
WITH THE REQUIREMENTS OF EACH JURISDICTION.
SITE RESTORATION
1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED PRIOR TO
PLACEMENT OF THE CONDUIT AND STRUCTURES.
2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED AND
WATERED IN TO ENSURE ITS SURVIVAL.
3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED PRIOR TO
CONSTRUCTION.
WATER QUALITY
1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF WASHINGTON'S
WATER QUALITY STANDARDS
2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE.
DIRECTIONAL BORING
1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS.
2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING UTILITIES.
FIRE PROTECTION
1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT.
2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE REPAIRED OR
REPLACED UPON DUCT OR CABLE PLACEMENT.
AERIAL INSTALLATION
1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS.
2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION.
3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO POWER MAIN
WHERE APPLICABLE.
4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG WITH APPLICABLE LOCAL AND REGIONAL
GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS IS TO BE VALIDATED
WITH THE DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION.
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
GENERAL NOTES
2 10
SCALE:
NO
SCALE
MFP23001352
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
LEGEND
3 10
SCALE:
NO
SCALE
LEGEND
Dual Mini Bridger
Line Extender
Telephone Pole
Power Pole
Joint Pole
Pedestal
Vault
End Of Line Block
500 Distribution
750 Trunk
A
M
V
HA
HD
LA
MFP23001352
1
2
3
4
5
6
SUN
S
E
T
B
L
V
D
N
E
BRONSON WAY NE
MATCHLINE SHEET 05
EDMONDS AVE NE1
2
2
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
4 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
7
8
9
10
11
12
13
NE
7
T
H
S
T
EDMONDS AVE NESUNSET BLVD NEMATCHLINE SHEET 04MATCHLINESHEET 062
2
4
5
3
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
5 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
14
15
16
17
18 19 20 21
22 23
24
25
26
27
28
NE
7
T
H
S
T
HARRINGTON AVE NEMATCHLINESHEET 056
6
6
7
8
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
6 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
MATCHLINESHEET 089
9
9
10
WHITMAN CT NESUNS
E
T
B
L
V
D
N
E
SUN
S
E
T
B
L
V
D
N
E
ANACORTES AVE NE10
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
7 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
MATCHLINESHEET 079
DUVALL AVE NESUN
S
E
T
B
L
V
D
N
E
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
8 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:1 PSE
318207-166477/A1366438
SECONDARY DRIP 30 06 N/A
COMCAST #1 23 06 N/A
TELCO #1 19 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:2 PSE
318212-166481/A1366437
SECONDARY DRIP 28 06 N/A
COMCAST #1 23 10 N/A
TELCO #1 21 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:3 PSE
318219-166484/A3767581
SECONDARY DRIP 32 00 N/A
COMCAST #1 25 05 N/A
TELCO #1 21 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:4 PSE
318230-166485
NEUTRAL 28 02 N/A
COMCAST #1 22 07 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:5 PSE
318252-166479
NEUTRAL 31 00 N/A
COMCAST #1 21 09 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:6 PSE
318270-166474
NEUTRAL 33 04 N/A
COMCAST #1 21 04 N/A
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:7 PSE
318286-166468
NEUTRAL 33 00 N/A
COMCAST #1 26 01 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:8 PSE
318306-166465
NEUTRAL 35 00 N/A
COMCAST #1 24 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:9 PSE
318323-166455
NEUTRAL 35 00 N/A
COMCAST #1 25 06 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:10 PSE
318336-166452
NEUTRAL 33 06 N/A
COMCAST #1 FIBER GLASS 28 06 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:11 PSE
318351-166447
NEUTRAL 35 00 N/A
COMCAST #1 26 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:12 PSE
318364-166446
NEUTRAL 35 00 N/A
COMCAST #1 23 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:13 PSE
318339-166600
NEUTRAL 32 06 N/A
COMCAST #1 WOOD ARM 20 06 N/A
TELCO #1 WOOD ARM 20 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:14 PSE
318340-166622
NEUTRAL 26 06 N/A
COMCAST #1 METAL ARM 22 07 N/A
TELCO #1 21 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:15 PSE
318334-166636/A11003378
SECONDARY DRIP 30 01 N/A
COMCAST #1 22 05 N/A
TELCO #1 WOOD ARM 19 07 N/A
D
N
N
N
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
POLE DATA
9 10
SCALE:
NO
SCALE
MFP23001352
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:16 PSE
318329-166648/A11003379
SECONDARY DRIP 28 04 N/A
COMCAST #1 25 00 N/A
TELCO #1 WOOD ARM 21 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:17 PSE
318322-166664/A11003380
SECONDARY DRIP 28 04 N/A
COMCAST #1 22 07 N/A
TELCO #1 WOOD ARM 20 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:18 PSE
318317-166685
SECONDARY DRIP 25 08 N/A
COMAST #1 20 09 N/A
TELCO #1 WOOD ARM 19 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:19 PSE
318315-166702/A0506039
NEUTRAL 27 04 N/A
COMCAST #1 23 04 N/A
TELCO #1 21 05 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:20 PSE
318315-166706/A0506038
SECONDARY DRIP 25 08 N/A
COMCAST #1 METAL ARM 22 06 N/A
TELCO #1 19 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:21 PSE
318316-166725/A0506037
SECONDARY DRIP 25 09 N/A
COMCAST #1 METAL ARM 19 09 N/A
TELCO #1 18 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:22 PSE
318317-166744/A0506036
SECONDARY DRIP 23 09 N/A
COMCAST #1 METAL ARM 20 10 LOWER TO 20'-04"
TELCO #1 19 01 N/A
D
N
Y
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:23 PSE
318320-166761/A3264921
SECONDARY DRIP 28 06 N/A
COMCAST #1 FIBER GLASS 22 09 N/A
TELCO #1 18 01 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:24 PSE
318326-166782
SECONDARY DRIP 30 04 N/A
COMAST #1 FIBER GLASS 25 08 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:25 PSE
318333-166793/A0506033
SECONDARY DRIP 23 00 N/A
COMCAST #1 METAL ARM 21 00 LOWER TO 19'-06"
TELCO #1 17 07 N/A
D
N
Y
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:26 PSE
318339-166805/A3812200
SECONDARY DRIP 28 01 N/A
COMCAST #1 FIBER GLASS 24 02 N/A
TELCO #1 WOOD ARM 22 02 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:27 PSE
318351-166823/A0506031
SECONDARY DRIP 30 09 N/A
COMCAST #1 26 10 N/A
TELCO #1 22 09 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:28 PSE
318352-166830/A1627540
SECONDARY DRIP 29 10 N/A
COMCAST #1 FIBER GLASS 26 03 N/A
TELCO #1 WOOD ARM 21 06 N/A
D
N
N
N
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
POLE DATA
10 10
SCALE:
NO
SCALE
MFP23001352
Cannon Construction LLC.
406 Porter Way
Milton, WA 98354
3/28/2023
City of Renton
1055 South Grady Way
Renton, WA 98057
RE: Aerial Variance Request for JB0001247483
To whom it may concern:
Cannon Construction has been contracted to design and engineer this project on behalf of
Comcast Cable Communications Management. Comcast is applying for a variance request in
order to upgrade their existing facilities.
Comcast proposes to TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075].OVERLASH (1) 96CT FIBER ON
EXISTING AERIAL STRAND.TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077].TIE IN TO EXISTING SPLICE
CASE [KV07S.7A]. OVERLASH (2) 96CT FIBER ON EXISTING AERIAL STRAND. TIE IN TO EXISTING SPLICE
CASE [SP.WAKV.0951]. TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]. PROOF & PULL (1) 96CT FIBER
FROM SP.0042WAKV TO SP.WABV.0052. PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT at
4621 NE Sunset Blvd Renton, WA 98059
Comcast is requesting that the City of Renton approve this variance request based on the fact
that the requirements for undergrounding this proposed over-lash on existing plant will cause
undue hardship.
1. Installation of undergrounding facilities will increase the total cost of construction
roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand.
2. Risk of potential damage to underground facilities will be increased.
3. Over-lash will not cause substantial adverse impact to other persons or entities in the
immediate area. Over-lashing the cable will be accomplished in a few days, and the
residents will not notice any impact. Comcast will clean up the over-lashed spans as
necessary and identify and remove any existing dead cables along this route.
4. The variance is necessary to prevent any undue hardship due to the increased
construction costs if forced to install the proposed extension underground.
5. The granting of the variance will not be materially detrimental to the public welfare.
Comcast does agree to participate in future underground improvements for its
proportionate share of the undergrounding costs, waiving the obligation into the future
when all other utilities are undergrounded to prevent an undue hardship against
Comcast currently.
Upon the granting of the variance, Comcast will coordinate construction and traffic control as
per your requirements. Comcast and their contractors want to cooperate at the highest level
and agree to adhere to all provisions and requirements set forth by the City of Renton to insure
safe installation and maintenance of the proposed facilities.
If you have any further questions regarding this project, please contact Christopher White
phone (253) 348-9733
Thank you for your consideration in this matter.
David Standring
Permit Coordinator
Cannon Construction Inc.
o 253-922-2787 | permitting@teamcannon.com
March 28, 2023
David Standring
Cannon Construction Inc.
4610 Tacoma Avenue,
Sumner WA 98390
Via Email: Permitting@teamcannon.com
SUBJECT: Request for Undergrounding Exemption (JB#1247483, MFP23001352, 4621 NE Sunset Blvd)
Dear Mr. Standring:
The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal
Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required
to be installed underground, pursuant to the standards of the section of RMC.
Comcast proposes to have Cannon Construction Inc overlash new 96Ct fiber for a total of approximately
6,164 lineal feet to existing Puget Sound Energy (PSE) poles along Sunset Blvd NE and NE 7th St within the
City. See the enclosed Site Plan showing the proposed overlashing limits.
ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720
grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below,
through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton.
Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service
providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service
provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are
underground, Grantee shall place its Cable System’s distribution cables underground within that area;
provided that such underground locations are actually capable of accommodating Grantee’s cable and
other equipment without technical degradation of the Cable Systems’ signal quality.
The proposal would utilize existing poles with other attached franchisee communication facilities and
overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need
to be provided for, any existing obsolete cable will need to be removed; staff recommends these as
conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast
franchise agreement which allows new overhead facilities to be placed overhead provided there are other
similar providers overhead as well. Comcast is required to obtain all necessary private utility easements
for work on private property.
DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C)
as requested by the applicant is approved with conditions subject to the conditions below as the request
complies with the Comcast Franchise Agreement.
Comcast Job JB#1247483
Page 2 of 2
March 28, 2023
Conditions of Approval:
1. Any existing height violations within the Project Reach must be resolved at the time of
construction. New aerial lines within the Project Reach must have a minimum vertical clearance
of 15’-6”.
2. Any abandoned or unused lines within the Project Reach must be removed at the time that
construction is taking place.
3. A traffic control plan must be separately submitted to the City, and no construction may take
place until the City has approved a traffic control plan.
4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in
the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other
utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a
franchisee within the Project Reach, in which case the Applicant shall participate in the joint use
trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made
available within the Project Reach that will accommodate the aerial lines. The new aerial lines
must be undergrounded within one year, or approved otherwise by the City of Renton Community
and Economic Development Administrator or designee, from the first event triggering the
requirement to underground the aerial lines.
This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period
from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed
with the City Clerk, along with the required appeal fee, by 5:00 pm, April 11, 2023. Due to the ongoing
state of emergency enacted by Governor’s Proclamation 20-28.14 (and as amended), the City Clerk’s
Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at
cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal
fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is
submitted electronically. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional
information regarding the appeal process may be obtained from the City Clerk’s Office,
cityclerk@rentonwa.gov.
Sincerely,
Brianne Bannwarth, PE
Development Engineering Director
cc: C.E. “Chip” Vincent, CED Administrator
Justin Johnson, Construction Engineering Manager
Scott Warlick, Engineering Specialist III
Holly Powers, Engineering Specialist III
Franchise Permits
Enclosures: Site Plan
PAGE 4
PAGE 5 PAGE 6
PAGE 7
PAGE 8
PROJECT MAP:
POLE INFORMATION:
POLE COUNT =
POLES THAT NEED PERMIT =
POLES THAT NEED MAKE READY =
TRANSMISSION =
DISTRIBUTION =
28
28
2
0
28
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
SITE ADDRESS:
4621 NE SUNSET BLVD
RENTON, WA 98059
CONTACTS:
CANNON COMPANIES
Christopher White - (253) 348-9733 - cwhite@teamcannon.com
COMCAST COMMUNICATION
Danny Cooley - (253)-215-7020 - Danny_Cooley@comcast.com
BUSINESS/JOB CONTACT
POC: SANDY RHINEHART - (425) 467-8584
SCOPE OF WORK:
JB0001247483
ALBERTSONS COMPANIES, INC
SHEET INDEX
1 -COVER
2 -GENERAL NOTES
3 -LEGEND
4-8 -CONSTRUCTION PLAN
9-10 -POLE DATA
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
- OVERLASH (1) 96CT FIBER ON EXISTING AERIAL STRAND.
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
- TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
- OVERLASH (2) 96CT FIBER ON EXISTING AERIAL STRAND.
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
- TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
- PROOF & PULL (1) 96CT FIBER FROM SP.0042WAKV TO SP.WABV.0052.
- PROOF & PULL (1) 96CT FIBER THROUGH EXISTING CONDUIT.
N
S
EW
*ALL FOOTAGES AND MATERIALS ARE ESTIMATEDBILL OF MATERIALS*:
NEW AERIAL =
OVERLASH =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
RISER =
TOTAL ROW FOOTAGE =
FT.
FT.
FT.
FT.
FT.
FT.
ROW FOOTAGES*:
NEW BUILDING PATHWAY =
EXISTING BUILDING PATHWAY =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
TOTAL SITE FOOTAGE =
FT.
FT.
FT.
FT.
FT.
SITE FOOTAGES*:
TOTAL PROJECT FOOTAGE = FT.
0
6,164
0
1,718
(0)0
7,882
0
0
0
0
0
7,882
FT + 20% STORAGE = FT96CT FIBER 7,882 9,458
Metro-E Wholesale
MFP23001352
STANDARD
1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO CONSTRUCTION.
THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS NECESSARY, TO DETERMINE
THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT THERE WILL BE INTERFERING UTILITIES AND
OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE
PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD. THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL
OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT
WORK IN SOME CASES PROPOSED PATH MAYBE IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES
NOT SHOWN ON THE PLANS WHICH MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL
TRAFFIC CONTROL, ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF
THESE OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES TO
PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES AND/OR UTILITY
RELOCATIONS DUE TO SAID CONFLICTS.
2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811
3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES.
4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEWATER,
AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES.
5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM.
6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO PREVENT ANY
HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE.
7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS.
8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED
TO NORMAL WORKING HOURS.
10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR WRITTEN
APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED.
11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT PROPERTIES
WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS OTHERWISE REQUIRED.
12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT,
UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE ONLY THOSE
LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A SPECIFIC TASK. NO LANE OR
ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS.
2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING NON-WORKING HOURS.
EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES AND AGENTS SHALL NOT PARK
PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN.
SITE PREPARATION
1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE EITHER
REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE.
2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE MATERIAL
(I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE).
3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
TRENCH EXCAVATION AND BACKFILL
1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL BACKFILL WITH
BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX 351 IS ACCEPTABLE IN ALL
LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN TRAFFIC-BEARING LOCATIONS.
2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
UTILITY DUCT
1. BURIED DUCT SHALL BE SCHEDULE 80 PVC OR EQUIVALENT, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36" WITH A
MINIMUM SLOPE OF 1/2 % TO VAULT.
2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED, PLUG ENDS OF
CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP CONDUITS CLEAR OF CONCRETE,
DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION.
3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL ROPE AND
PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE SIMPLEX COMPRESSION
PLUGS SEALING THE CONDUITS AROUND THE CABLE.
4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL ROPES AND
PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED.
CEMENT CONCRETE PAVEMENT
1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD SPECIFICATIONS OF
EACH JURISDICTION.
ASPHALT CONCRETE PAVEMENT
1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT CONCRETE
ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION.
GRAVEL AREAS
1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN ACCORDANCE
WITH THE REQUIREMENTS OF EACH JURISDICTION.
SITE RESTORATION
1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED PRIOR TO
PLACEMENT OF THE CONDUIT AND STRUCTURES.
2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED AND
WATERED IN TO ENSURE ITS SURVIVAL.
3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED PRIOR TO
CONSTRUCTION.
WATER QUALITY
1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF WASHINGTON'S
WATER QUALITY STANDARDS
2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE.
DIRECTIONAL BORING
1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS.
2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING UTILITIES.
FIRE PROTECTION
1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT.
2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE REPAIRED OR
REPLACED UPON DUCT OR CABLE PLACEMENT.
AERIAL INSTALLATION
1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS.
2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION.
3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO POWER MAIN
WHERE APPLICABLE.
4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG WITH APPLICABLE LOCAL AND REGIONAL
GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS IS TO BE VALIDATED
WITH THE DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION.
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
GENERAL NOTES
2 10
SCALE:
NO
SCALE
MFP23001352
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
LEGEND
3 10
SCALE:
NO
SCALE
LEGEND
Dual Mini Bridger
Line Extender
Telephone Pole
Power Pole
Joint Pole
Pedestal
Vault
End Of Line Block
500 Distribution
750 Trunk
A
M
V
HA
HD
LA
MFP23001352
1
2
3
4
5
6
SUN
S
E
T
B
L
V
D
N
E
BRONSON WAY NE
MATCHLINE SHEET 05
EDMONDS AVE NE1
2
2
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
4 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
7
8
9
10
11
12
13
NE
7
T
H
S
T
EDMONDS AVE NESUNSET BLVD NEMATCHLINE SHEET 04MATCHLINESHEET 062
2
4
5
3
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
5 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
14
15
16
17
18 19 20 21
22 23
24
25
26
27
28
NE
7
T
H
S
T
HARRINGTON AVE NEMATCHLINESHEET 056
6
6
7
8
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
6 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
MATCHLINESHEET 089
9
9
10
WHITMAN CT NESUNS
E
T
B
L
V
D
N
E
SUN
S
E
T
B
L
V
D
N
E
ANACORTES AVE NE10
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
7 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
MATCHLINESHEET 079
DUVALL AVE NESUN
S
E
T
B
L
V
D
N
E
CONSTRUCTION NOTES:
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0075]
OVERLASH (1) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0076]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0077]
TIE IN TO EXISTING SPLICE CASE [KV07S.7A]
OVERLASH (2) 96CT FIBER ON EXISTING AERIAL
STRAND.
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0951]
TIE IN TO EXISTING SPLICE CASE [SP.WAKV.0107]
PROOF & PULL (1) 96CT FIBER FROM
SP.0042WAKV TO SP.WABV.0052.
PROOF & PULL (1) 96CT FIBER THROUGH
EXISTING CONDUIT.
1
2
3
4
5
6
7
8
9
10
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
CONSTRUCTION PLAN
8 10
SCALE:
0 50'100'
N
S
EW
MFP23001352
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:1 PSE
318207-166477/A1366438
SECONDARY DRIP 30 06 N/A
COMCAST #1 23 06 N/A
TELCO #1 19 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:2 PSE
318212-166481/A1366437
SECONDARY DRIP 28 06 N/A
COMCAST #1 23 10 N/A
TELCO #1 21 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:3 PSE
318219-166484/A3767581
SECONDARY DRIP 32 00 N/A
COMCAST #1 25 05 N/A
TELCO #1 21 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:4 PSE
318230-166485
NEUTRAL 28 02 N/A
COMCAST #1 22 07 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:5 PSE
318252-166479
NEUTRAL 31 00 N/A
COMCAST #1 21 09 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:6 PSE
318270-166474
NEUTRAL 33 04 N/A
COMCAST #1 21 04 N/A
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:7 PSE
318286-166468
NEUTRAL 33 00 N/A
COMCAST #1 26 01 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:8 PSE
318306-166465
NEUTRAL 35 00 N/A
COMCAST #1 24 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:9 PSE
318323-166455
NEUTRAL 35 00 N/A
COMCAST #1 25 06 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:10 PSE
318336-166452
NEUTRAL 33 06 N/A
COMCAST #1 FIBER GLASS 28 06 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:11 PSE
318351-166447
NEUTRAL 35 00 N/A
COMCAST #1 26 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:12 PSE
318364-166446
NEUTRAL 35 00 N/A
COMCAST #1 23 02 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:13 PSE
318339-166600
NEUTRAL 32 06 N/A
COMCAST #1 WOOD ARM 20 06 N/A
TELCO #1 WOOD ARM 20 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:14 PSE
318340-166622
NEUTRAL 26 06 N/A
COMCAST #1 METAL ARM 22 07 N/A
TELCO #1 21 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:15 PSE
318334-166636/A11003378
SECONDARY DRIP 30 01 N/A
COMCAST #1 22 05 N/A
TELCO #1 WOOD ARM 19 07 N/A
D
N
N
N
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
POLE DATA
9 10
SCALE:
NO
SCALE
MFP23001352
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:16 PSE
318329-166648/A11003379
SECONDARY DRIP 28 04 N/A
COMCAST #1 25 00 N/A
TELCO #1 WOOD ARM 21 06 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:17 PSE
318322-166664/A11003380
SECONDARY DRIP 28 04 N/A
COMCAST #1 22 07 N/A
TELCO #1 WOOD ARM 20 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:18 PSE
318317-166685
SECONDARY DRIP 25 08 N/A
COMAST #1 20 09 N/A
TELCO #1 WOOD ARM 19 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:19 PSE
318315-166702/A0506039
NEUTRAL 27 04 N/A
COMCAST #1 23 04 N/A
TELCO #1 21 05 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:20 PSE
318315-166706/A0506038
SECONDARY DRIP 25 08 N/A
COMCAST #1 METAL ARM 22 06 N/A
TELCO #1 19 07 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:21 PSE
318316-166725/A0506037
SECONDARY DRIP 25 09 N/A
COMCAST #1 METAL ARM 19 09 N/A
TELCO #1 18 00 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:22 PSE
318317-166744/A0506036
SECONDARY DRIP 23 09 N/A
COMCAST #1 METAL ARM 20 10 LOWER TO 20'-04"
TELCO #1 19 01 N/A
D
N
Y
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:23 PSE
318320-166761/A3264921
SECONDARY DRIP 28 06 N/A
COMCAST #1 FIBER GLASS 22 09 N/A
TELCO #1 18 01 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:24 PSE
318326-166782
SECONDARY DRIP 30 04 N/A
COMAST #1 FIBER GLASS 25 08 N/A
D
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:25 PSE
318333-166793/A0506033
SECONDARY DRIP 23 00 N/A
COMCAST #1 METAL ARM 21 00 LOWER TO 19'-06"
TELCO #1 17 07 N/A
D
N
Y
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:26 PSE
318339-166805/A3812200
SECONDARY DRIP 28 01 N/A
COMCAST #1 FIBER GLASS 24 02 N/A
TELCO #1 WOOD ARM 22 02 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:27 PSE
318351-166823/A0506031
SECONDARY DRIP 30 09 N/A
COMCAST #1 26 10 N/A
TELCO #1 22 09 N/A
D
N
N
N
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:28 PSE
318352-166830/A1627540
SECONDARY DRIP 29 10 N/A
COMCAST #1 FIBER GLASS 26 03 N/A
TELCO #1 WOOD ARM 21 06 N/A
D
N
N
N
/
DATE:
DRAWN BY:
PROJECT MANAGER:
CODE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0001247483ALBERTSONS COMPANIE, INC4621 NE SUNSET BLVDRENTON, WA 98059METRO-E WHOLESALE17-050
02/22/2023
C.WHITE
D.DELEON
POLE DATA
10 10
SCALE:
NO
SCALE
MFP23001352
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Conditions for Permit MFP23001352
Engineering
1 A traffic control plan must be separately submitted to the City, and no construction may take place until the City
has approved a traffic control plan.
2 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial
lines within the Project Reach must have a minimum vertical clearance of 15'-6".
3 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the
Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the
Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the
Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or
(3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial
lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and
Economic Development Administrator or designee, from the first event triggering the requirement to underground
the aerial lines.
4 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking
place.
Page 1 of 1