HomeMy WebLinkAboutMFP23001296.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23001296 IVR Number: 23001296 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:03/10/2023Application Date:3344500234Parcel Number: 1417 N 24TH ST Permit Type:03/29/2023Issue Date:Franchise Permit Work Class:03/28/2024Expiration Date:Minor Utility Job Number: JB0001344737Franchise Type:Cable Description: Comcast JB0001344737 This project proposes to remove approx. 160' of existing aerial cable between 2 utility poles. Then proof and pull new cable through existing conduit to new CATV vault and utility pole. Also bore approx. 24'. All excavation work will meet or exceed all current city standards. We will not disturb any monuments we pass. Out path of travel will remain 10' from all monuments. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Leah Ihlenfeldt Cablecom 1316 Bonneville Avenue Snohomish, WA 98290 ApplicantX Jessamin Santos Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (206) 401-2188Contact Corrie Lamb Comcast 2525 Beaufort Dr. Modesto, CA 95355 Contact CABLECOM LLC 20021 120th Ave NE, #101 BOTHELL, WA 98011 B: (360) 668-1300Contractor Business License Number: 52252Construction Contractor: CABLEL*971DP Jessamin Santos Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (206) 401-2188Emergency Contact MANGAT SUKHJINDER & SINGH P 1415 N 24TH ST RENTON , WA 98056 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP23001296 Scott Warlick 3/29/2023 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS MFP23001296 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 3/29/2023 D/WD/WD/WD/WD/WD/WD/WD/WD/WEOPEOPEOPEOP EOP SSWWWW1415 N 24thSt, Renton, WA980562407 MeadowAve N, Renton,WA 980561412 N 24thSt, Renton, WA980561405 N 24thSt, Renton,WA 980561509 N 24thSt, Renton,WA 98056N 24TH ST 25 MPHMEADOW AVE N 25 MPHSPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEV.HOST VEHICLE WEIGHT! 22,000 OEV.MPH50/7035/4525/30TAPERTANGENT403020806040CHANNELIZATION DEVICESPACING (feet)GENERAL NOTES:1.ALL "W" SERIES SIGNS SHALL BE 48" FLUORESCENT ORANGE, UNLESS OTHERWISE NOTED.2.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS.3.PEDESTRIAN SPOTTERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAIN OPEN SIDEWALKS AND ADA RAMPS.4.NOTIFY TRANSIT AUTHORITY FIVE DAYS PRIOR TO STARTING WORK.5.ALL LANES SHOULD BE A MINIMUM OF 10' IN WIDTH AS MEASURED TO THE NEAR FACE OF THE CHANNELIZING DEVICES.RURAL ROADS & URBAN ARTERIALSURBAN STREETS25 MPH OR LESS100' +/- (2)200' +/- (2)35 / 40 MPH25 / 30 MPH350' +/- (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.SIGN SPACING = X (1)RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSSignTraffic Cone or DelineatorLEGENDWork VehicleFlaggerD/W*=SPOTTER SHALL BE PLACED AT ALL " " DRIVEWAYSALONG THE ROUTE TO ASSIST MOTORISTS DURINGCONSTRUCTION**ROADWORKAHEADW20-1XXX ONE LANEROADAHEADW20-4W20-7BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1XXXW20-7XXXONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-710' MIN. 18'-7" 22'TRAFFIC CONTROLTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXISTING AERIAL STRAND AND TRENCHRENTON10ISSUE FOR PERMIT02/24/2023DOMTC-11SCALE: N.T.S.MFP23001296 COVER-TITLETHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OF1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMScope of work to Target address 1415 N 24th St, Renton, WA·This project proposes to remove approx. 160' of existingaerial cable between 2 utility poles. Then proof and pullnew cable through existing conduit to new CATV vault andutility pole. Also bore approx. ~25'. All excavation workwill meet or exceed all current city standards.·We will not disturb any monuments we pass. Our path oftravel will remain 10' from all monuments.BUILD In The City ROW·Bore footage:~25'·3' x 3' Bore Pits: 2·New CATV Pedestal(s): 1·New CATV Vault(s): 2·New Utility Pole: 1·Proof & Pull footage:~185'·Existing Utility Pole(s): 2·Aerial cable removed footage:~160'VICINITY MAPSHEET INDEXSheet #1C-1Cover-Title2G-1General Notes3SW-1Stormwater Protection Plan4CD-1Construction Plans5D-1 Construction Details6SD-1Municipality StandardsSCALE: NONEContactC-1PROJECT ID: JB13447371CD-1Jessamin SantosComcastJessamin_Santos@cable.comcast.com206-401-2188MFP23001296 GENERAL NOTESTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMROADWAY CENTER LINEEXISTING COMCAST ROUTEEXISTING FENCELINEPROPOSED BORE ROUTEEXISTING WATER LINEEXISTING STORM DRAINEXISTING SANITARY SEWEREXISTING JOINT TRENCHEXISTING RECYCLED WATER LINEEXISTING TV SYSTEMEXISTING GAS SYSTEMEXISTING ELECTRICAL SYSTEMEXISTING TELEPHONE SYSTEMPROPERTY LINELINETYPESBORE PITWATER MANHOLEUNIDENTIFIED MANHOLEGAS METERWATER METERELECTRIC MANHOLESEWER CLEAN OUTSANITARY SEWER MANHOLESTORM DRAIN MANHOLECATCH BASINGAS/WATER VALVETREE/BUSHESGWEXISTING POLEEXISTING COMCAST PEDESTALNEW RISER ATTACHED TO POLEEXISTING IRRIGATION VAULTEXISTING COMCAST VAULTEXISTING UTILITY VAULT/PEDESTALSSCOECOWSDMONUMENTFIRE HYDRANTTRAFFIC SIGNAL COMBINATIONSTREET LIGHTTRANSFORMERNEW COMCAST LOW PROFILE NEW COMCAST PEDESTALNEW COMCAST VAULTPOWER SUPPLY W/ METERNEW COMCAST POWER SUPPLYSYMBOLSEXISTING WATEREXISTING TELEPHONEDRIVEWAYMAXIMUMD/WMAXW T RIGHT OF WAYEXISTING SANITARY SEWEREXISTING STORM DRAINPUBLIC UTILITY EASEMENTPROPERTY LINEMINIMUMFACE OF CURBEXISTINGCENTER LINECOMCASTL MINFOC (E) COMCAST CABBREVIATIONSPUEROWSS SDPL JTSSSDW+++TVTEGTVCATVNEW AERIAL STRAND/CABLE ROUTEOFFSETO/SBACK OF WALKBOWREMOVAL/REPAIRR/RNEW(N) G-12EDGE OF PAVEMENTEOPANCHOR SUPPORTPROOF & PULL ROUTE (NEW CABLE IN (E) CONDUITS)PROPOSED TRENCH ROUTERWOPGENERAL NOTES1.ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS.2.CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS(AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800)227-2600.3.CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIORTO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE,CONTRACTOR MUST VERIFY.4.CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OFCONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE.5.CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITEAT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY OF RENTONAND/OR LAW ENFORCEMENT UPON REQUEST.6.CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALLBE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTINGSTRIPING AND REMOVING UNNECESSARY "USA" MARKINGS.7.CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISEAPPROVED IN WRITING BY THE "CITY ENGINEER."8.CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITHTHE CITY OF RENTON AND STATE OF WASHINGTON STANDARD PLANS AND SPECIFICATIONS,AND CURRENT WASHINGTON DEPARTMENT OF TRANSPORTATION "MANUAL OF UNIFORMTRAFFIC CONTROL DEVICES" AND "WASHINGTON MODIFICATION (468-95 WAC)" FOR USE INPERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIREDFOR ALL LANE CLOSURES.9.CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITHREGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVINGJURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OFWASHINGTON UTILITIES AND TRANSPORTATION COMMISSION, THE STATE OF WASHINGTONDEPARTMENT OF LABOR AND INDUSTRIES, DIVISION OF OCCUPATIONAL SAFETY ANDHEALTH (DOSH), THE COUNTY OF KING, ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TOINSPECTION BY CITY ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST.10.CONTRACTOR SHALL "RED-LINE" ALL LAYOUTS, PLANS AND DETAILS, ON THE DAY OFCONSTRUCTION AND SUBMIT A COMPLETE SET OF "AS-BUILT" PLANS TO COMCAST UPONCOMPLETION OF THE PROJECT, AND TO CITY.11.CONTRACTOR SHALL NOTIFY RESIDENTS AFFECTED BY THE WORK IN LANDSCAPED AREA INADVANCE OF CONSTRUCTION.12.CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OFWORK COMMENCING.13.LANE CLOSURES ARE PROHIBITED BEFORE 8:30 AM AND AFTER 4:00 PM (3:00 PM OFFRIDAYS AND ON DAYS PRECEDING DESIGNATED LEGAL HOLIDAYS). NO LANE CLOSURES AREPERMITTED ON WEEKENDS AND HOLIDAYS.MFP23001296 CONCRETE WASHOUT450 MM(18") MIN.450 MM(18") MIN.25 MM (1") MIN.CONCRETEWASHOUTAREA NOTES:1.) FACE SIGN TOWARD NEAREST STREET OR ACCESS POINT.2.) CONCRETE WASHOUT SHALL BE LOCATED BEHIND THE CURB AND 15 M (50 FT.) MINIMUM FROM DRAINAGE INLETS OR WATERCOURSESBALE CONFIGURATIONTHIS SECTION REMOVED FORGRAPHICAL REPRESENTATIONONLY. STRAW BALE PERIMETERSHALL BE CONTINUOUS.SIGN600 MM(24") MIN.36 CM (14") MIN.3 M (10') MIN. TYP. OF 4 SIDES STRAW BALESAA900 MM(36") MIN.SECTION A - A60 MIL POLYETHYLENE50 X 50 MM (2" X2")STAKES OR #4 J-BARS2 PER BALE TYP.STRAW BALESINLET SEDIMENTCONTROL45° NOTES:1.) SEDIMENT TRAPPED UPSTREAM OF SEDIMENT CONTROL BMP SHALL BE REMOVED WEEKLY AND PRIOR TO A RAINFALL EVENT.2.) PLACE BMP'S TIGHTLY TOGETHER AT JOINTS TO PREVENT OR MINIMIZE SEEPAGE AT JOINTS.GRAVEL BAG(S) OR OTHER ACCEPTEDSEDIMENT CONTROL BMP. PLACE BAGSTIGHT AGAINST FACE OF CURB.BACK OF CURBFACE OF CURBLIP OF GUTTERDRAINAGE INLETWITH FILTER BAGPLAN VIEWSEE NOTE 2FLOWTHE MAXIMUM DRAINAGE AREA PER FILTER SHALL BE NO MORE THAN 0.8 HECTARES (2 ACRES).THE FILTER BAG SHALL BE MANUFACTURED FROM UV RESISTANT POLYPROPYLENE, NYLON, POLYESTER, OR ETHYLENE FABRIC WITH A MINIMUM TENSILE STRENGTH OF 50 LBS PER LINEAL FOOT, AN EQUIVALENT OPENING SIZE NOT GREATER THAN 20 SIEVE AND WITH A MINIMUM FLOW RATE OF 40 GALLONS/MINUTE/SQ FT.THE FILTER BAG MAY BE SUSPENDED FROM OR HELD IN PLACE BY THE EXISTING INLET GRATE (OR OTHER APPROVED METHOD), PROVIDING NO MODIFICATION OR DAMAGE SHALL BE DONE TO THE INLET GRATE OR FRAME. THE INLET GRATE SHALL NOT BE CAUSED TO REST MORE THAN 13MM (.5") ABOVE THE INLET FRAME (SEE DETAIL A).THE FILTER BAG MAY EXTEND TO THE BOTTOM OF THE INLET BOX PROVIDED THE OUTLET PIPE IS UNOBSTRUCTED.FLOWS SHALL NOT BE ALLOWED TO BYPASS THE BAG. THE BAG OR ITS FRAME SHALL CATCH FLOWS AT ALL SIDES OF THE INLET, EXCEPT AS SHOWN FOR FLOOD RELEASE.INLET FILTER BAGS SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL DURING THE WET SEASON AND MONTHLY DURING THE DRY SEASON. SEDIMENT AND DEBRIS SHALL BE REMOVED BEFORE ACCUMULATIONS HAVE REACHED ONE THIRD THE DEPTH OF THE BAG. BAGS SHALL BE REPAIRED OR REPLACED AS SOON AS DAMAGE OCCURS. EXISTING DROPINLET GRATEPLACEMENT AT TYPE A, C, D, & F DROP INLETSAND PARKING LOTSEXISTING DROPINLET FRAMEFILTER BAG(OPTIONAL)FRAME EXISTING DROPINLET GRATEBAG DEPTHMAXIMUMDETAIL AOUTLET PIPE1.3 CM (.5")MAXIMUMPLACEMENT AT TYPE B AND E DROP INLETSMINIMUMAT BACK(FLOODRELEASE)5 CM (2")18" MINIMUM EXISTING OPENBACK HOODCONTACTAT FRONTAND SIDESDETAIL AGRATE)MINIMUMBAG WIDTH(BACK OF5 CM (2")MINIMUMDAM CONTACT,ALL SIDESCURBSTORM DRAIN INLETFILTER BAGOUTLET PIPE65DETAIL A4.3.2.NOTES1.FILTER BAGFILTER BAGSTORM WATERPROTECTION PLANSTORM WATER PROTECTION PLANTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMSW-13MFP23001296 D/WD/WD/WEOPEOPEOPEOP EOP SSWWWSDWSSSSSSSSSSWWWWWWCATVCATVCATVCATVOPOPOPOPOPOPOP1415 N 24th St,Renton, WA 980562407 Meadow Ave N,Renton, WA 980561412 N 24th St,Renton, WA 980561405 N 24th St,Renton, WA 980561509 N 24th St,Renton, WA 98056N 24TH STMEADOW AVE NEXISTING UTILITY POLE(TO BE REMOVED ATA LATER DATE BY POWERCOMPANY)NEW CATV VAULT-REF. DETAIL ON SHEET D-1~160' OF EXISTING AERIAL CABLE TO BE REMOVEDPROOF AND PULL ~185' OF NEWCABLE IN EXISTING CONDUITNEW CATV PEDESTAL-RE. DETAIL ON SHEET D-1EXISTING UTILITY POLE(TO BE REMOVED ATA LATER DATE BY POWERCOMPANY)3' X 3' BORE PIT. PLACE NEW CATV VAULTUPON COMPLETION-REF. DETAIL ON SHEET D-1NEW UTILITY POLE~25' BORE ROUTE-REF. DETAIL ON SHEET D-1SCALE: 1:20CONSTRUCTION PLANSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMCD-14MFP23001296RESTORATION PER CITY OF RENTON STANDARDSPOTHOLE ALL EXISTING UTILITIES A HIGH DENSITY REINFORCED CONCRETE BOX,WITH NON-SETTLING SHOULDERS POSITIONED TOMAINTAIN GRADE AND FACILITATE BACKFILLING.APPROXIMATE DIMENSIONS SHOWN.B36 VAULT DETAILSCALE: N.T.S.BORE PIT DETAILSCALE: N.T.S.(E) CURB & SIDEWALK3'x3' BORE/RECEIVING PITTRENCH RESTORATIONPER CITY OF RENTONSTANDARD DETAILS2" CONDUIT.BORE DEPTH SHALLBE BELOWSANITARYSEWER MAIN TOCLEAR ALL UTILITYCONSTRUCTION DETAILSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMD-15MFP23001296 CONSTRUCTION DETAILSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1415 N 24TH ST, RENTON, WAJB1344737-FORCED RELOCATEREMOVE EXIST. AERIAL STRAND, BORE, PROOF & PULLRENTON60ISSUE FOR PERMIT02/24/20231FIELD REVISIONS03/07/2023DOMSD-16MFP23001296