Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
26 00 00-6-0 - Roundabout Lighting
MATERIAL TRANSMITTAL To: Skanska Transmittal No.: 019 Attn: Paul Tosello Date: 3-29-23 Project: SWA2 Amazon Project No.: Owner: Amazon Location: Renton, WA Previous Transmittal No. (if resubmitted) Bid Item Spec. Paragraph Number Item Description and Use Manufacturer Dwg. No(s). Approval Status (Engineer) 1 Lighting 16th and Raymond Roundabout Various By this submittal, the Contractor represents that he has determined and verified all field measurements, field construction criteria, materials, catalog numbers and similar data, or will do so, and that he has checked and coordinated each Shop Drawing with the project requirements and the Contract Documents. Deviations from the Contract Documents are noted below. COMMENTS: Contractor Ceccanti, Inc. Signature Brandon McDonald (THIS SPACE FOR REVIEW ENGINEER) To: Date: Approval status as noted above is in accordance with the following legend: A. No Exceptions Taken B. Make Corrections Noted C. Revise and Resubmit D. Submit Specified Item By: E. Rejected cc: F. See attached Review Comment Sheet dated Request for Approval of Material Contract Number 221110 FA Number SR Date Section / Title of Pr Roundabout Lighting SW 16th ST and Raymond Ave SW County King Contractor Ceccanti Subcontractor West Coast Signal This form shall be completed prior to submittal. If this form is not complete at time of submittal it may be returned for information that was omitted. For assistance in completing, see Instructions and Example Project Engineer Distribution State Materials Engineer Distribution Contractor Region Materials General File Signing Inspection Region Operations Engineer Fabrication Inspection DOT Form 350-071 EF Revised 12/2012 State Materials Lab M/S 47365 Other For WSDOT Use Only RAM # Bid Item No. Material or Product/Type Name and Location of Fabricator, Manufacturer or Pit Number Specification Reference PE/QPL Code Hdqtr./QPL Code 2A Light Poles P&K Tubular Products – East Setauket N.Y. 9-29.6(1) 2A Fixtures Cyclone – Terrebone Q.C. 9-29.10(1)A 2A Deco Arms Garmire – Marysville, WA 9-29.6(1) 2A Deco Bases Visco – Eugene, OR 9-29.6(1) 2A Anchor Bolts Portland Bolt – Portland, OR 9-06.6(4) 2A Service Cabinets Skyline MFG – Seattle, WA 9-29.24 2A Adaptor Plates Garmire – Marysville, WA 9-29.6(1) Project Engineer Date State Materials Engineer Date Acceptance Action Codes for use by Project Engineer and State Materials Laboratory 1. Acceptance Criteria: Acceptance based upon 'Satisfactory' Test Report for samples of materials to be incorporated into project. 2. Acceptance Criteria: Mfg. Cert. of Compliance for 'Acceptance' prior to use of material. 3. Acceptance Criteria: Catalog Cuts for 'Acceptance' prior to use of material. Catalog Cut Approved Yes No 4. Acceptance Criteria: Submit Shop Drawings for 'Approval' prior to fabrication of material. 5. Acceptance Criteria: Only 'Approved for Shipment', 'WSDOT Inspected' or 'Fabrication Approved Decal' material shall be used. 6. Acceptance Criteria: Submit Certificate of Materials Origin to Project Engineer Office. 7. Acceptance Criteria: Request Transmitted to State Materials Laboratory for Approval Action. 8. Source Approved: 9. Approval Withheld: Submit samples for preliminary evaluation. 10. Approval Withheld: 11. Miscellaneous Acceptance Criteria. Remarks: Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: RTA0X40AYBX-ALUM 40FT-RAL9005TX PRIMER- PLUS TOP COAT-REF DWG # 18655.1 Notes: Type: LGNW23-96717 Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: CY55P1B-FGC-T3-P70-40K-240- 10KV-TBC-BK-TX-MG-CP3624 Notes: Type: 100W LGNW23-96717 Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: COR-PL-10-CA-A-BK70TX Notes: Type: (*) LGNW23-96717 Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: OCT10-CAST IRON SPLIT BASE-10- 1/8 ID" TOP ID-RAL9005TX Notes: Type: LGNW23-96717 Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: (SET=4) 1-1/4 X 54 F1554 GR55- GALV 14.5" BC Notes: Type: SETS LGNW23-96717 APPROVED BYAPPROVED BY DATEDATE Bill of Material Bill of Material (Line 1)(Line 1) QTY.QTY.SIZESIZE LEN.LEN.GRADE / DESCRIPTIONGRADE / DESCRIPTION 36 1-1/4 54 ASTM F1554 Grade 55 rod 216 1-1/4 ASTM A563 Grade DH heavy hex nut 216 1-1/4 ASTM F436 Type 1 hardened washer NotesNotes Meets the S1 requirement for weldability Heavy hex nut dimensions meet ASME B18.2.2 Finish: Galvanized per ASTM F2329 and A153 Hardware is not provided assembled Drawings are not to scale xx PROJECTPROJECT Renton Housing Authority CUSTOMERCUSTOMER THE LIGHTING GROUP Portland Bolt & Manufacturing Co.Portland Bolt & Manufacturing Co. 3441 NW Guam St. Portland, OR 97210 [p] 800.547.6758 [f] 503.227.4634 [e] sales@portlandbolt .com [w] www.portlandbolt.com© PORTLAND BOLT 2023© PORTLAND BOLT 2023 PAGEPAGE 1 of 4 ORDERORDER QUOTEQUOTE 173915 rev. 3 BYBY KT DATEDATE 3/28/2023 PROVIDED BY PORTLAND BOLT Submitted by The Lighting Group LLCMichelle Alexander Job Name: City of Renton - SW 19Th St/Lind Ave SW & SW 19Th St/Raymond Ave SW-Roundabout (aka Job 1332 Renton Amazon Signal and Lighting) Architect: Pending Architect Catalog Number: (SET=4) 1-1/4 X 54 F1554 GR55- GALV 14.5" BC Notes: Type: SETS LGNW23-96717 APPROVED BYAPPROVED BY DATEDATE Bill of Material Bill of Material (Line 2)(Line 2) QTY.QTY.SIZESIZE LEN.LEN.GRADE / DESCRIPTIONGRADE / DESCRIPTION 18 1 ASTM A36 round plate NotesNotes Finish: Galvanized per ASTM F2329 and A153 Drawings are not to scale xx PROJECTPROJECT Renton Housing Authority CUSTOMERCUSTOMER THE LIGHTING GROUP Portland Bolt & Manufacturing Co.Portland Bolt & Manufacturing Co. 3441 NW Guam St. Portland, OR 97210 [p] 800.547.6758 [f] 503.227.4634 [e] sales@portlandbolt .com [w] www.portlandbolt.com© PORTLAND BOLT 2023© PORTLAND BOLT 2023 PAGEPAGE 2 of 4 ORDERORDER QUOTEQUOTE 173915 rev. 3 BYBY KT DATEDATE 3/28/2023 PROVIDED BY PORTLAND BOLT SWA2 AMAZON GRAYBAR for WEST COAST SIGNAL SKYLINE ELECTRIC & MFG. CO. SCALE DATE / DRAWN BY DRAWING NO. N.T.S. 3-21-23 / C.S.T. 67987 1 2 3 4 5 6 FRONT SIDE CITY OF RENTON SKYLINE SERIES# 64380-5G 1 REQUIRED SEE COMPONENT SCHEDULE AND CABINET SPECIFICATIONS THE METER DOOR IS REMOVABLE AND COMES STANDARD HINGED ON THE LEFT. HINGING ON THE RIGHT IS AVAILABLE AS A NO-CHARGE OPTION FOOTPRINT DEADFRONT SERVICE WIREWAY WIRING SCHEMATIC METER BASE MAIN CONTROL LTG. GROUND FAULT RECEPT. NEUTRAL GROUND PHOTO CELL TEST SWITCH 120/240V, SINGLE PHASE, 3 WIRE CITY OF RENTON SERVICE CABINET PER STANDARD PLANS 122.1, 122.2 SKYLINE SERIES# 64380-5G COMPONENT SCHEDULE 1 METERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5TH JAW AT 9:00 POSITION 2 PANELBOARD: 120/240 VAC, 250 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, 65K AIC SERIES RATED MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON PDD22G0200TFFJ BOLT-ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 40/1 SIGNAL 2 - 60/2 SMALL CELL BRANCH 1 - 15/1 CONTROL 3 - 20/1 SPARE NO BREAKER SCHEDULE PROVIDED, PLEASE VERIFY PRIOR TO RELEASE 3 CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 8910DPA34V02 – 1 REQUIRED 4 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 5 PHOTO-CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) 6 GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8” 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2” ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, “BEST” LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER-TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 – REQUIRED UL LISTED PER STANDARD #508A “SUITABLE FOR USE AS SERVICE ENTRANCE” SWA2 AMAZON CITY OF RENTON GRAYBAR P.O.# 4703630923 WEST COAST SIGNAL 3-21-23 C.S.T. S.O.# 67987 SKYLINE ELECTRIC & MFG. COMPANY I N C O R P O R A T E D Switchboards Panelboards Steel Cabinets UL Registered Metal Punching . . Forming . . Welding Industrial Control Panels 3619 7TH AVENUE SOUTH SEATTLE, WASHINGTON 98134 TELEPHONE (206) 682-4422 FAX (206) 682-0927 Garmire IronWorks, Inc. 5620-48th Drive N.E. • Marysville, WA 98270 (360) 651-1001 • Fax (360) 651-1002 • sales@garmireironworks.com GABP1X15X15-15BCX1.25TO11.5BCX1-45DEG-HDG TOP VIEW: SIDE VIEW: (NO SCALE) 8"DIAMETERCENTER HOLE 1"A36PLATE X 15" X 15" SQUARE FIISH: HDG-HOT DIP GALVANIZED (4) 1-1/2"BOLT HOLES AT 90-DEGREES ON A 15" BOLT CIRCLE (10.6" BOLT SQUARE) (4) 1" X 8" ATR AT 90-DEGREES ON A 11- 1/2" BOLT CIRCLE (8-1/8" BOLT SQUARE)