Loading...
HomeMy WebLinkAboutWeston Heights Utility Plan III Comments16-002651PRIVATE REMOVE CONDITION #2. UNDER SEPARATE PERMITDEMOLITOIN UNDERSEPARATE PERMIT (TYP)IS A CATCH BASIN FILTERSTILL BEING USED? PROVIDE DIMENSIONSOF SEDIMENT TRAP FORCONTRACTORINSTALLATION ADD COR STD. PLAN 216.30FOR CATCH BASIN INLETPROTECTION IF IT IS BEINGPROPOSED.UPDATE. SHOULDREAD SEDIMENTTRAP. PRIVATELABEL 10' UTILITYEASEMENT FORCITY UTILITIESADD DIMENSIONSHOW ACCESSEASEMENT IN THISAREA AS WELLSTATION STREETINTERSECTION14 ftCHECKSTATION STATION ISINCORRECT PRIVATEPROVIDE POSTMASTERAPPROVAL FORMAILBOX LOCATIONPROVIDE POSTMASTERAPPROVAL FORMAILBOX LOCATIONFILL IN GRINDAND OVERLAYSHOW, CALL OUT,STATION, ANDDIMENSION, NOTCH INCURB FOR RAMPRECEIVING AREA REMOVE DETAIL MAINTAIN 8'PLANTER WIDTHAT CURBS (TYP)LABEL CURVERADIUSLABEL CURVERADIUSSHOW SLOPESPROVIDE EXISTING ANDPROPOSED SPOTELEVATIONS TO ENSURECONSTRUCTABILITY PRIVATEADD NOTE TO PLAN STATING THAT ALLGRADING ALONG THE EASTERN EDGE OFPRIVATE ROAD C NEEDS TO BE DONE ON SITE.LABEL PADELEVATIONSMOVE CB #7 SO THAT IT ISON THE CURB LINE AND NOTIN THE FLOW LINE. THIS CBINSTALLATION WILL STILLHAVE A VANED GRATE.1 ft SHOW SURVEY BACKGROUND TEXTTHAT SHOWS INFORMATION ABOUTEXISTING STRUCTURES.PROVIDE DETAILS SHOWINGHOW PIPES WILL ENTER CB #4AND CB #7. A TYPE 1L OR TYPE2 CATCH BASIN MAY BENECESSARY TO ACCOMODATETHE PIPE LAYOUT DOESN'T MATCHHORIZONTAL CONTROLPLAN. CHECKSTATIONS (TYP)EX.LABEL MATERIAL OF PIPESEGMENTS. THE PIPESEGMENTS FROM CB #1 TOOUTLET #1 AND CB #12 TO CB#11 SHALL BE DUCTILE IRON.INLET #1CB #2 SHALL BE ATYPE 2 STRUCTURESINCE RIM TO INVERTIS GREATER THAN 5'.DOESN'TMATCH LEFT13.93%LABEL IE OF INLET #1DOESN'T MATCHCONTROLSTRUCTURE DETAIL PRIVATEPROVIDE THISDETAIL IN THEPLAN SETPIPE MATERIALTHIS DOESN'T MATCH CB#10 DETAIL TO THE LEFTTHIS DOESN'T MATCH CB #10 INTHE PROFILE TO THE RIGHTTURN OFFLABELS (TYP)DIAMETER OF ORIFICEDOESN'T MATCH KCRTSINPUT, 7/8"?STORMWATER POND TOBE INSTALLED ON FENCEPER CITY STANDARDS.PER COR STD. PLAN 224.00 A 50 FOOT DISPERSIONTRENCH CAN ONLY ACCOMODATE A MAXIMUM OF 0.5CFS OF FLOW. THE OUTLET FLOW FROM THE KCRTSMODEL IS GREATER THAN 0.5 CFS. REVISE DESIGN. MATCH PROFILE SHEET C4.1 REVISE TABLE. NUMEROUS ITEMS DONOT MATCH PLANSAND PROFILE.SHOW SURVEY BACKGROUND TEXTTHAT SHOWS INFORMATION ABOUTEXISTING STRUCTURES.UPDATE NOTETO ACCOUNTFOR SSMH #8. LABEL MATERIAL OF ALLPIPE SEGMENTS.THIS MANHOLE SHALLBE A SHALLOWMANHOLE PER CORSTD. PLAN 400.2. SHOW WATER ANDPOWER CROSSINGCLEAN UPEX. IE OUT:520.00 (8" W)EX. IE OUT:501.58 (8" W)SHOW AND LABEL ROADINTERSECTIONS. UPDATE TO MOST RECENT DETAILS.ADD COR STD. PLAN 400.2 SANITARYSHALLOW MANHOLE TO PLANS. Horiz. Scale Vert. Scale Project No.Date No. Client Contact Approved By Checked By Designed By Drawn By REVISIONS DateDescriptionKnow what'sbelow.before you dig.CallRTDR TDR JLS CTB 04-22-2016TENW 5221 1"=20'SEC. 11, TWP. 23 N, RGE. 5 E., W.M.WESTON HEIGHTS, LLC 15 LAKE BELLEVUE, STE 102 BELLEVUE WA 98005 (425)869-1300 ROBERT FITZMAURICE WESTON HEIGHTSU15-006162TENW Transportation Planning | Design | Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 Transportation Engineering NorthWest Project Contact: Elyse Hanson, P.E. Phone: 425-250-5004 ILLUMINATION DETAILSIL-04 The civil base shown on Sheet LA-1 (storm lines, structures,etc.) does not match what is shown on the civil plans. Revise sheet so that it matches the civil plans.