HomeMy WebLinkAboutA_Response to TIR and Site Plan Redline Comments_LUA14-000708_v2PROJECT IS VESTED TO 2009 CITY OF RENTON SURFACE WATER DESIGN MANUAL AMMENDMENTS. EDITS to the text in the drainage report is needed to correctly describe the proposed stormwater elements as mentioned in THE STORMWATER MANUAL. please set up meeting with rohini nair AFTER 8.17.2017 TO DISCUSS THE CHANGES. the threshold for requiring flow coontrol facility is the difference in more than 0.1 cfs of flow from exisitng forested site conditions to the post developed conditions. basic dispersion basic dispersion appendix a of 2009 PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT (6') HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE-QUARTER FEET (1.25') FOR EVERY ONE INCH (1") OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50') INDICATING THE WORDS, “NO TRESPASSING – PROTECTED TREES,” OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET (50'). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES. PLEASE SHOW PROTECTION FENCING ON EROSION CONTROL PLAN. DISPERSION TRENCH CONFLICTS WITH TREE PROTECTION. LABEL PIPE DIAMETER, LENGTH, PIPE MATERIAL ETC. TYPICAL