Loading...
HomeMy WebLinkAboutP_Permit_Set_Neptune_Lobby_Restroom_TI_230230315_v1ARCHITECT: GENERAL CONTRACTOR: PROPERTY MANAGER: TENANT: NEPTUNE TOWERS UPDATES DESCRIPTION: VICINITY MAP: PROJECT TEAM:1 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 TOWER TWO CODE INFORMATION: COVER SHEET I-0.0 SITE PLAN · · WORK UNDER SEPARATE PERMITS: · DRAWING INDEX GENERAL NOTES:ABBREVIATIONS: SYMBOL LEGEND:GENERAL NOTES & SYMBOLS I-0.1 DEMOLITION NOTES:REFLECTED CEILING NOTES:DOOR NOTES: “” “ ” ” DIMENSION NOTES: ELECTRICAL NOTES: FINISH NOTES:1 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 EXIT EXIT FLOOR 2 EXIT PLAN EXIT PLAN & CODE SUMMARY I-CS.2 EXIT1 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 FLOOR 2 OCCUPANCY OCC ROOM NAME RM #SF LOAD FACTOR OCC. LOAD EXIT EXIT FLOOR 4 EXIT PLAN EXIT PLAN & CODE SUMMARY I-CS.3 EXIT1 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 FLOOR 4 OCCUPANCY OCC ROOM NAME RM #SF LOAD FACTOR OCC LOAD LEVEL 4 FINISH & FLOOR PLAN FINISH & FLOOR PLAN I-2.11 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 FLOOR PLAN KEY NOTES: FINISH SPECIFICATIONS: LEVEL 2 FINISH & FLOOR PLAN SYMBOLS LEGEND SYMBOL MFG. RCP KEY NOTES: LEVEL 4 REFLECTED CEILING PLAN REFLECTED CEILING PLAN I-3.11 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 LEVEL 2 REFLECTED CEILING PLAN K-2882VERTICYLLAVATORIESVITREOUS CHINA 2'-10"9 I-8.1 NEW MIRROR, SEE FLOOR PLAN FOR SPEC NEW FAUCET, SOAP DISPENSER, & SINK, SEE FLOOR PLAN FOR SPEC SOLID SURFACE COUNTER, SS-1 UPDATED LIGHTING PER RCP. BASE AS SPECIFIED WALL TILE WT-1 UPDATED LIGHTING. REFER TO RCP FOR INFORMATION. WALL TILE WT-2 EXISTING TOILETS TO REMAINPAINT BELOW COUNTER NEW STAINLESS STEEL TOILET PARTITIONS5"NEW CEILING PANELS CP-1, SEE RCP FOR MORE INFO UPDATED LIGHTING PER RCP WOOD BASE, WB-1 EXISTING ELEVATOR DOORS/FRAMES TO REMAIN WALL COVERING, WC-1 RUBBER BASE, RB-1 ACCENT PAINT, P-2 NEW FAUCET, SOAP DISPENSER, & SINK, SEE FLOOR PLAN FOR SPEC SOLID SURFACE COUNTER, SS-1 UPDATED LIGHTING PER RCP. BASE AS SPECIFIED WALL TILE, WT-1 PAINT BELOW COUNTER NEW STAINLESS STEEL TOILET PARTITIONS EXISTING TOILETS TO REMAIN NEW TOILET ACCESSORIES 5'-6"5'-10"NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3" OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EACH. CONNECTION POINT NO. 9 GA. LATERAL SUPPORT WIRE AT CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR MAIN STRUCTURAL RUNNER 4'-0" O.C. CROSS TIE RECESSED FIXTURE 45° 45° 60° MAX. TYP. NEW FINISHED GWB SURFACE NEW CEILING PANELS CP-1, SEE RCP FOR MORE INFO UPDATED LIGHTING PER RCP NEW FINISHED GWB SURFACE EXISTING RUBBER BASE HI/LOW DRINKING FOUNTAIN W/BOTTLE FILLER, SPEC: ELKAY LZSTL8WSLK 36" MAX38"-43"MAX5'-10"2'-10"5"2'-5"2'-3"9"6" 1'-5"5"8" 2'-0" U.N.O. PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED SEE FINISH PLAN FOR COUNTERTOP AND BACKSPLASH INFORMATION KOHLER SINK, SEE FLOOR PLAN FOR MORE INFORMATION INSULATED EXPOSED DRAIN PIPING HATCHED AREA INDICATES CLEARANCES REQUIRED PER ADA SLOAN FAUCET. SEE FLOOR PLAN FOR MORE INFORMATION. BASE AS SPECIFIED PAINT WALL. REFER TO 5/I-8.1 FOR MORE INFORMATION. HANGER WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE ATTACHED WALLS AT CATEGORY D, E & F USE BERC2 BY ARMSTRONG OR EQ. CEILING NOTED AS 'B' ON 3/ I-9.2, CATEGORY C ALWAYS USES BERC2 8" MAX. 7/8" STABILIZER BAR OR OTHER SUITABLE SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART TYPICAL WALL MOULDING PER SCHEDULE. TYPICAL HEAVY DUTY SUSPENDED CEILING GRID SYSTEM PER SCHEDULE UNATTACHED WALLS CAN USE BERK CLIP OR POP RIVET NOTED AS 'B/P' ON 3/ I-9.2 FOR CATEGORY D,E,F 8" MAX. 7/8" VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE RUNNER ENDS AT OPPOSITE WALLS TO FLOAT FREE ON PERIMETER ANGLE. PROVIDE 3/4" CLEARANCE BETWEEN ENDS OF GRID & WALL NOTES: 1.LATERAL BRACING CLUSTER: (4) 12 GA. GALV. SOFT-ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" O.C. MAX. AND 6'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2.SUSPENSION WIRE: 12 GA. GALV. SOFT-ANNEALED MILD STEEL WIRE ENCASED IN 12" DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T'. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY. 45° MAX. TYP. NOTE #1 COMPRESSION STRUT (NOTE #2) NOTE #1 3 TURNS MIN. WITHIN 3" TYP. MAIN RUNNER, HEAVY DUTY CROSS 'T" 2" MAX. TYP.Date/Time:Author:Pen Table:Dwg:X'Ref:2/9/2023 4:09 PML:\2022\22-0501\DWG\WIP\MASTER\I-8.1.DWGJPC STD.CTB ATB.dwg, EMILY VAN DYKEINTERIOR ELEVATIONS AND DETAILS I-8.1 SCALE: 3/8" = 1'-0" RESTROOM ELEVATION - SINK WALL1 SCALE: 3/8" = 1'-0" RESTROOM ELEVATION - SECTION VIEW2 SCALE: 3/8" = 1'-0" ELEVATOR LOBBY ELEVATION - WEST5 SCALE: 3/8" = 1'-0" ELEVATOR LOBBY ELEVATION - EAST71 INCHc 2018, JPC ARCHITECTS, LLC DESIGN DRAWN CHECKED NO. JURISDICTION STAMP NEPTUNE TOWER 2 UPDATES LOBBIES & RESTROOMS 700 S Renton Village Pl Renton, WA 98057 JPC EV SG 22-0501 03.10.2023 PERMIT ISSUE REGISTERED ANN KUSKA DERR STATE OF WASHINGTON ARCHITECT 6485 SCALE: 1" = 1'-0" RESTROOM SINK DETAIL9 SCALE: 3/8" = 1'-0" RESTROOM ELEVATION - STALL WALL3 SCALE: 1 1/2"=1'-0" CEILING - APC - PERIMETER SUPPORT 11 SCALE: N.T.S. CEILING - APC - LIGHT FIXTURE BRACING10 SCALE: 3"=1'-0" CEILING - APC - BRACING DIAGRAM12 SCALE: 3/8" = 1'-0" DRINKING FOUNTAIN9