HomeMy WebLinkAboutP_Permit_Set_Neptune_Lobby_Restroom_TI_230230315_v1ARCHITECT:
GENERAL CONTRACTOR:
PROPERTY MANAGER:
TENANT:
NEPTUNE TOWERS UPDATES
DESCRIPTION:
VICINITY MAP:
PROJECT TEAM:1 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
TOWER TWO
CODE INFORMATION:
COVER SHEET
I-0.0
SITE PLAN
·
·
WORK UNDER SEPARATE PERMITS:
·
DRAWING INDEX
GENERAL NOTES:ABBREVIATIONS:
SYMBOL LEGEND:GENERAL NOTES &
SYMBOLS
I-0.1
DEMOLITION NOTES:REFLECTED CEILING NOTES:DOOR NOTES:
“”
“
”
”
DIMENSION NOTES:
ELECTRICAL NOTES:
FINISH NOTES:1 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
EXIT
EXIT
FLOOR 2 EXIT PLAN
EXIT PLAN & CODE
SUMMARY
I-CS.2
EXIT1 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
FLOOR 2 OCCUPANCY
OCC ROOM NAME RM #SF LOAD
FACTOR OCC. LOAD
EXIT
EXIT
FLOOR 4 EXIT PLAN
EXIT PLAN & CODE
SUMMARY
I-CS.3
EXIT1 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
FLOOR 4 OCCUPANCY
OCC ROOM NAME RM #SF LOAD
FACTOR OCC LOAD
LEVEL 4 FINISH & FLOOR PLAN
FINISH & FLOOR
PLAN
I-2.11 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
FLOOR PLAN KEY NOTES:
FINISH SPECIFICATIONS:
LEVEL 2 FINISH & FLOOR PLAN
SYMBOLS LEGEND
SYMBOL MFG.
RCP KEY NOTES:
LEVEL 4 REFLECTED CEILING PLAN
REFLECTED
CEILING PLAN
I-3.11 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
LEVEL 2 REFLECTED CEILING PLAN
K-2882VERTICYLLAVATORIESVITREOUS CHINA
2'-10"9
I-8.1
NEW MIRROR, SEE
FLOOR PLAN FOR SPEC
NEW FAUCET, SOAP
DISPENSER, & SINK, SEE
FLOOR PLAN FOR SPEC
SOLID SURFACE COUNTER,
SS-1
UPDATED LIGHTING
PER RCP.
BASE AS SPECIFIED
WALL TILE WT-1
UPDATED LIGHTING.
REFER TO RCP FOR
INFORMATION.
WALL TILE WT-2
EXISTING TOILETS TO REMAINPAINT BELOW COUNTER
NEW STAINLESS STEEL
TOILET PARTITIONS5"NEW CEILING PANELS CP-1,
SEE RCP FOR MORE INFO
UPDATED LIGHTING
PER RCP
WOOD BASE, WB-1
EXISTING ELEVATOR
DOORS/FRAMES TO REMAIN
WALL COVERING, WC-1
RUBBER BASE, RB-1
ACCENT PAINT, P-2
NEW FAUCET, SOAP
DISPENSER, & SINK, SEE
FLOOR PLAN FOR SPEC
SOLID SURFACE COUNTER,
SS-1
UPDATED LIGHTING
PER RCP.
BASE AS SPECIFIED
WALL TILE, WT-1
PAINT BELOW COUNTER
NEW STAINLESS STEEL
TOILET PARTITIONS
EXISTING TOILETS TO
REMAIN
NEW TOILET
ACCESSORIES
5'-6"5'-10"NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3"
OF EACH CORNER OF LIGHT FIXTURE. SPLAY
WIRES AS SHOWN AND FASTEN TO BEAM OR
PURLIN. MIN. OF 3 WIRE TURNS EACH.
CONNECTION POINT
NO. 9 GA. LATERAL SUPPORT WIRE AT
CENTER ENDS OF EA. FIXTURE. FIXTURE
SUPPORT WIRE SUPPLIED BY CEILING
CONTRACTOR
MAIN STRUCTURAL
RUNNER 4'-0" O.C.
CROSS TIE
RECESSED
FIXTURE
45°
45°
60° MAX. TYP.
NEW FINISHED GWB SURFACE
NEW CEILING PANELS CP-1, SEE
RCP FOR MORE INFO
UPDATED LIGHTING
PER RCP
NEW FINISHED GWB SURFACE
EXISTING RUBBER BASE
HI/LOW DRINKING FOUNTAIN
W/BOTTLE FILLER, SPEC:
ELKAY LZSTL8WSLK
36" MAX38"-43"MAX5'-10"2'-10"5"2'-5"2'-3"9"6"
1'-5"5"8"
2'-0" U.N.O.
PROVIDE BLOCKING
BEHIND CABINET AND
IN WALL AS REQUIRED
SEE FINISH PLAN FOR COUNTERTOP
AND BACKSPLASH INFORMATION
KOHLER SINK, SEE FLOOR PLAN
FOR MORE INFORMATION
INSULATED EXPOSED
DRAIN PIPING
HATCHED AREA INDICATES
CLEARANCES REQUIRED
PER ADA
SLOAN FAUCET. SEE FLOOR PLAN
FOR MORE INFORMATION.
BASE AS SPECIFIED
PAINT WALL. REFER TO 5/I-8.1
FOR MORE INFORMATION.
HANGER WIRE AT EACH
PERIMETER MAIN TEE
AND PERIMETER
CROSS TEE
ATTACHED WALLS AT CATEGORY
D, E & F USE BERC2 BY
ARMSTRONG OR EQ. CEILING
NOTED AS 'B' ON 3/ I-9.2,
CATEGORY C ALWAYS USES BERC2
8" MAX.
7/8"
STABILIZER
BAR OR OTHER SUITABLE
SYSTEM TO KEEP PERIMETER
COMPONENTS FROM
SPREADING APART
TYPICAL WALL MOULDING
PER SCHEDULE.
TYPICAL HEAVY DUTY
SUSPENDED CEILING
GRID SYSTEM PER SCHEDULE
UNATTACHED WALLS
CAN USE BERK CLIP OR
POP RIVET NOTED AS
'B/P' ON 3/ I-9.2 FOR
CATEGORY D,E,F
8" MAX.
7/8"
VIEW SHOWING LATERAL BRACING
CLUSTER AND SUSPENSION WIRE
RUNNER ENDS AT
OPPOSITE WALLS
TO FLOAT FREE
ON PERIMETER
ANGLE. PROVIDE
3/4" CLEARANCE
BETWEEN ENDS OF
GRID & WALL
NOTES:
1.LATERAL BRACING CLUSTER: (4) 12 GA. GALV. SOFT-ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF
CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED
12'-0" O.C. MAX. AND 6'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT.
2.SUSPENSION WIRE: 12 GA. GALV. SOFT-ANNEALED MILD STEEL WIRE ENCASED IN 12" DIAM. CONDUIT (FOR UPLIFT RESTRAINT);
SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T'. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND
SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY.
45° MAX. TYP.
NOTE #1
COMPRESSION
STRUT (NOTE #2)
NOTE #1
3 TURNS MIN.
WITHIN 3" TYP.
MAIN RUNNER,
HEAVY DUTY
CROSS 'T"
2" MAX. TYP.Date/Time:Author:Pen Table:Dwg:X'Ref:2/9/2023 4:09 PML:\2022\22-0501\DWG\WIP\MASTER\I-8.1.DWGJPC STD.CTB ATB.dwg, EMILY VAN DYKEINTERIOR
ELEVATIONS AND
DETAILS
I-8.1
SCALE: 3/8" = 1'-0"
RESTROOM ELEVATION - SINK WALL1
SCALE: 3/8" = 1'-0"
RESTROOM ELEVATION - SECTION VIEW2
SCALE: 3/8" = 1'-0"
ELEVATOR LOBBY ELEVATION - WEST5
SCALE: 3/8" = 1'-0"
ELEVATOR LOBBY ELEVATION - EAST71 INCHc 2018, JPC ARCHITECTS, LLC
DESIGN
DRAWN
CHECKED
NO.
JURISDICTION STAMP
NEPTUNE
TOWER 2 UPDATES
LOBBIES & RESTROOMS
700 S Renton Village Pl
Renton, WA 98057
JPC
EV
SG
22-0501
03.10.2023 PERMIT ISSUE
REGISTERED
ANN KUSKA DERR
STATE OF WASHINGTON
ARCHITECT
6485
SCALE: 1" = 1'-0"
RESTROOM SINK DETAIL9
SCALE: 3/8" = 1'-0"
RESTROOM ELEVATION - STALL WALL3
SCALE: 1 1/2"=1'-0"
CEILING - APC - PERIMETER SUPPORT 11
SCALE: N.T.S.
CEILING - APC - LIGHT FIXTURE BRACING10
SCALE: 3"=1'-0"
CEILING - APC - BRACING DIAGRAM12
SCALE: 3/8" = 1'-0"
DRINKING FOUNTAIN9