Loading...
HomeMy WebLinkAboutMFP23001619 5028 Lake Washington Blvd.pdfDEPARTMENT OF COMMUNITY c AND ECONOMIC DEVELOPMENT 7 . Minor Franchise Permit: MFP23001619 IVR Number: 23001619 Permit Name: Coal Creek / Lee Sewer Connection Address/Location: 5028 LAKE WASHINGTON BLVD NE Parcel Number: 3343300866 Application Date: 03/28/2023 Permit Type: Franchise Issue Date: 04/12/2023 Permit Work Class: Minor Utility Expiration Date: 04/11/2024 Franchise Type: Water / Sewer Job Number: Hyun Lee SeN Description: Install sewer stub for Coal Creek Utility District. Restoration per City of Renton standards. Approved traffic control plan required. Call in all work to inspection line 24 hours prior. (425) 430 7203 Billing Type Name Address Phone Applicant PATRICK MARTIN 6801 132nd PI SE B: (425) 235-9200 COAL CREEK UTILITY DISTRICT Newcastle, WA 98059 C: (206) 255-1961 Contact Calvin Megiveron B: (425) 235-9200 Coal Creek Utility District X Contact COAL CREEK WATER & SEWER 6801 132nd PI SE B: (425) 235-9200 DISTRICT Newcastle, WA 98059 Contact Eric Houser C: (206) 920-0450 K S CONSTRUCTION INC Contact K S CONSTRUCTION INC 5535 S 320TH St B: (253) 545-0229 Auburn, WA 98001 Emergency PATRICK MARTIN 6801 132nd PI SE B: (425) 235-9200 Contact COAL CREEK UTILITY DISTRICT Newcastle, WA 98059 C: (206) 255-1961 Emergency Dan Gravelle C: (206) 786-2676 Contact Coal Creek Utility District - Emergency Owner CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Hyun Lee 5028 Lake Washington Blvd Renton WA 98056 • Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. • This permit and plans must be posted at the job site at all times. • 1 hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. • Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for N work in the Right of Way. • Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. • In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.101C (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Signature) (Date) THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Page 1 of 1 DEPARTMENT OF PUBLIC WORKS Transportation Division 1 1055 South Grady Way, 5th Floor I Renton, WA 98057 1 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 1012712021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (S) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ❑ Electronic Copy of the TCP Application ❑ Electronic Copy of the TCP Layout, on 11" X 17" paper size format, which shall: ■ Include map(s) showing the location of the project and work area. ■ Be legible lettering and clear, contrasting, symbols of viewing or printing. ■ Must indicate street names, and north arrow and scale. ■ Types of plans required: o Work hour plan — show all mobility impacts during construction hours. o Non -work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. • Changing construction phases — show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to _ with the subject line "TCP Application —[Project Name]." Develoi)mentEnaineering@RentonWA.gov Project Name: Coal Creek / Lee Sewer Connection Permit #: Site Address: 5028 LAKE WASHINGTON BLVD. NE. RENTON, WA. 98056 Work Date: From Monday - Friday Work Time: Start Construction Company: KS CONSTRUCTION INC. Contact Name: ERIC HOUSER Business Address: 5535 S. 320TH ST. MFP23001619 9:00 am End 3:00 pm Phone/Cell: 206 920-0454 City/State: AUBURN Zip: 98001 Description of Work: EXTEND SEWER FROM EXISTING STUB IN R.O.W. TO PROPERTY LINE. APPROXIMATELY 50'. ALL WORK IN THE SHOULDER. 4pproval By: Date: Transportation Engineering Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 3 1 Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. • Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney's fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder's agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit orjudgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City's reasonable attorney's fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non -work hours. • Any vehicle, equipment, barricade, or portable tow -away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 1 Published: 10/27/2021 • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City's maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant's Signature DU`.q k— licant's Name (Print) Date 0 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. 4 ,may �v`��. Page 3 of 3 1 Published: 10/27/2021 TRAFFIC MANAGEMENT I N C O R P O R A T E D KS CONSTRUCTION GENERAL NOTES -TRAFFIC CONTROL It is the responsibility of the contractor performing work to install and maintain the traffic control devices as shown herein, as well as any such additional traffic control devices as may be required to ensure the safe movement of vehicular and pedestrian traffic through or around the closure area and provide maximum protection and safety to workers. All traffic control devices shall be kept in their proper position at all times and shall be repaired, replaced, or cleaned as necessary to preserve their appearance, continuity and capability. All traffic control devices shall conform to the latest accepted edition of the Manual on Uniform Traffic Control Devices ( M.U.T.C.D.). Any revisions to these drawings shall be approved in writing by the Engineer of Record and the Agency having jurisdiction. The Agency Traffic Engineering Division reserves the right to observe the traffic control operations and to make any necessary changes. Any directed changes shall supersede these plans and shall be implemented at the sole expense of the contractor. Contractor shall provide flagmen as necessary to give adequate warning to traffic or to the public of any dangerous conditions to be encountered. Contractor shall remove temporary traffic delineation, signage, and other devices when no longer required, and shall restore areas to original conditions. Contractor shall cover existing signs where they conflict with construction detours and signing. All open excavation or construction work shall be a minimum of 5' from any operating traffic lanes. Contractor shall post uneven pavement signs, and ramp vertical pavement offset of 1 inch or more with asphalt for smooth transition. The contractor shall provide for access to all adjacent properties during work hours. Construction operations shall be conducted in such a manner as to cause as little inconvenience as possible to abutting property owners/operators. All signs shall be reflectorized and standard size. The contractor shall provide for safe pedestrian access at all times. SIGN SPACING = X (1) MINIMUM LANE CLOSURE TAPER LENGTH = L (FEET) LANE POSTED SPEED LIMIT (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 660 - 12 125 180 245 320 540 600 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65L733O LENGTH (feet) 155 200 250 305 360 425 495 570 645 TANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. > 22,000 lbs. < 45 45-55 > 55 < 45 45-55 > 55 MPH MPH MPH MPH MPH MPH 100' 123' 172' 74' 100' 150' FREEWAYS & 55/70 MPH 1500' +/- EXPRESSWAYS RURAL HIGHWAYS 60/65 MPH 800' +/- RURAL ROADS 45/55 MPH 500' +/- RURAL ROADS & URBAN 35/40 MPH 350' +/- ARTERIALS RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' +/- (2) RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. INC MINIMUM SHOULDER TAPER LENGTH = L/3 (FEET) SHOULDER WIDTH (feet) POSTED SPEED LIMIT (MPH) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 200 220 240 LEGEND ADDRES5 WORK AREA TRAFFIC CONTROL: 5028 LAKE WA5HINGTON BLVD NE PROJECT ® WORK AREA I -TYPE-III 13ARRICADEW/51GN FLAGGER X TYPE -II BARRICADE W/ SIGN FLASHING ARROW 51GN (FA5) ]I ADA BARRICADE W/ SIGN CED UNIFORMED POLICE OFFICER • CHANNELIZATION DEVICE d EXISTING 51GN SIGN 5028 LAKE` /W A5 H I N GTO N L Y NE, K E N TO N WA CONTACT: EKIC HOU5ER TRAFFIC MANAGEMENT, INC. California -Great Lakes -PwificNorthwest 800.763.3999 Ag www.trafficmanagement.com TMIIN Traffic Control Services - Sales & Rentals Permits&Consulting- Engineering - Training C31 # 785804 CONTACT: 206 920-0454 JOB NUMBER: 414671 PLAN#: 79239 PERMIT NUMBER: COVER SHEET SIZE: P 5CALE: N.T.S. DATE: 4/7/23 PREPARED BY: MN TMI CONTACT PERSON: Michael Flanagan TCS CERT #: 301872 LEGEND ® - WORK AREA r FLAGGER FLASHING ARROW 51GN (FA5) P.o UNIFORMED POLICE OFFICER - EXI5TING 51GN W20-7a W20-4 W20-1 ONE LANE ROAD ROAD WORK AHEAD AHEAD LAKE WASHINGTON P LVD NE F200'NT!5-1-200'NT!5—i-200'NTS-1 [ 50 MPH 1 41 FLAGGER WITH 12' MIN rLhwcK WI I r1 PAnln r'MAAA1 Ir.11rATInr.1 KADIO COMMUNICATION �_200' NT5--1 —ZUU' N1 5—' - W20-1 W20-4 W20-7a AFFROX 545' TO 5E 73RD 5T ROAD ONELANE • WORK ROAD AHEAD AHEAD I - TYPE -III BARRICADE W/ 51GN X TYPE -II BARRICADE W/ 51GN �I ADA BARRICADE W/ 51GN • CHANNELIZATION DEVICE - 51GN APPRE55 5028 LAKE WASH I NGTON BLVD NE, RENTON, WA 0' 20' 40' 80' SCALE: 1 " = 40' CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/65 10 to 20 80 35/45 10 to 20 60 25/30 10 to 20 40 WORK AREA TRAFFIC CONTROL: 5028 LAKE WA5HINGTON SLVD NE PROJECT CONTACT: ERIC HOU5ER CONTACT: (206) 920-0454 JOB NUMBER: 414671 PERMIT NUMBER: SHEET 1 OF 1 SIZE: P DATE: 4/7/23 TRAFFIC MANAGEMENT, INC. Cafifomia • Great Lakes • Pacific Northwest PLAN#:79239 800.763.3999 Ag ON) www.trafficmanagement.com TMIIN Traffic Control Services - Sales & Rentals SCALE: 1 � �=40' Permits & Consulting - Engineering - Training PREPARED BY: MN5 C31 # 785804