HomeMy WebLinkAboutPRE23-000081_Meeting SummaryPREAPPLICATION MEETING FOR
Finseth Short Plat
PRE 23-000081
CITY OF RENTON
Department of Community & Economic Development
Planning Division
April 20, 2023
Contact Information:
Planner: Jill Ding, 425.430.6598, jding@rentonwa.gov
Public Works Plan Reviewer: Sam Morman, 425-430-7383, smorman@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 425.430.7235
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
formal submittal.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
M E M O R A N D U M
DATE: April 3, 2023
TO: Jill Ding, Senior Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Finseth Short Plat
1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings
up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square
feet, a minimum of 1,500 gpm fire flow would be required. A minimum of on e fire hydrant is
required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to
1,500 gpm. At least one new fire hydrant will be required to be installed.
2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit.
This fee is paid at building permit issuance.
3. Fire department apparatus access roadways are required to be a minimum of 20-feet
wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways
shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required
within 150-feet of all points on the buildings. Dead end street over 150-feet requires a
hammerhead type fire apparatus turnaround.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: April 20, 2023
TO: Jill Ding, Senior Planner
FROM: Sam Morman, Civil Engineer
SUBJECT: Finseth Short Plat
15XX Morris Ave S
PRE23-000081
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s) 7222000281
and 7222000282. The following comments are based on the pre-application submittal made to the City of
Renton by the applicant.
Water
1. The project is within the City of Renton’s water service area in the West Talbot Hill 300 Pressure Zone.
2. The static water pressure is approximately 75 psi at ground elevation of 126 feet.
3. There is an existing 8-inch water main located in Morris Ave S that can deliver a maximum flow
capacity of 2,000GPM (see water plan No. W-314207).
4. Based on the review of project information submitted for the pre-application meeting, Renton
Regional Fire Authority has determined that the preliminary fire flow demand for single-family homes
is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the
dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required.
5. Based on the information provided with the pre-application submittal documents, the following
developer’s installed water main improvements will be required to provide domestic and fire
protection service to the development including but not limited to the items that follow.
• An 8-inch water main extension within the new private access road connecting to the
existing 8-inch water main in Morris Ave S and extending to the eastern end of the access
road to serve the proposed lots will be required.
• A 15-foot-wide public water easement is required for any public water main, hydrants and
water meters located outside City Right-of-Way.
• Installation of a separate water service (minimum 1-inch) and meter for each new single
family residence. The sizing of the meter shall be in accordance with the most recent edition
of the Uniform Plumbing Code. Installation of the service and water meter shall be done by
City forces, a separate water permit is required.
• Installation of a landscape irrigation meter with a backflow prevention assembly (DCVA) if
applicable.
• A new fire hydrant will be required along Morris Ave S at its intersection with the new private
access road. The location and number of hydrants will be determined by the RRFA based on
the final fire flow demand and final site plan.
6. Civil plans for the water main improvements will be required and must be prepared by a professional
engineer registered in the State of Washington. Please refer to City of Renton General Design and
Construction Standards for Water Main Extensions as shown in Appendix K of the City’s 2019 Water
System Plan. Adequate horizontal and vertical separations between the new water main and other
utilities (storm sewer pipes and vaults, sanitary sewer, power, gas, electrical) shall be provided for the
operation and maintenance of the water main. Retaining walls, rockeries or similar structures cannot
be installed over the water main unless the water main is installed inside a steel casing.
7. A conceptual utility plan will be required as part of the land use application for the subject
development.
8. The development is subject to applicable water system development charges (SDC’s) and meter
installation fees based on the number and size of the meters for domestic uses and for fire sprinkler
use. The development is also subject to fees for water connections, cut and caps, and purity tests.
Current fees can be found in the 2023 Development Fees Document on the City’s website. Fees will
be charged based on the rate at the time of construction permit issuance.
• The SDC fee for water is based on the size of the new domestic water to serve the project.
The current water fee is $4,850.00 per 1-inch meter.
• Water service installation charges for each proposed domestic water service is applicable.
Water Service installation is $2,875.00 per 1-inch service line,
• Drop-in meter fee is $400 per ¾-inch meter and $460.00 per 1-inch meter.
• A credit will be applied to the existing services if abandoned.
• The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof
Renton
Sanitary Sewer
1. The project is within the City of Renton’s sanitary sewer service area.
2. There is an 8-inch gravity wastewater main located in Morris Ave S (see record drawing S-002206).
3. An 8-inch sewer main extension to serve the proposed lots is likely required.
• A 15-foot-wide public sewer easement is required for any public sewer main located outside
City Right of Way.
4. Individual sewer stubs from the sewer main and individual side sewers are required for each lot. All
new sewer stubs shall conform to the standards in RMC 4-6-040 and City of Renton Standard Details.
5. A conceptual utility plan will be required as part of the land use application for the subject
development.
6. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer
is based on the size of the new domestic water to serve the project. Current fees can be found in the
2023 Development Fees Document on the City’s website. Fees will be charged based on the rate at
the time of construction permit issuance.
• The current sewer SDC fee is $3,650.00 per 1-inch meter.
• Final determination of applicable fees will be made after the water meter size has been
determined.
• The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof
Renton
Surface Water
1. There is no existing stormwater main in Morris Ave S. The nearest stormwater main and catch basin
are located in the intersection of Morris Ave S and S 15th St (see record drawing W-314208).
2. Any new on or off-site drainage systems must be designed in accordance with Chapter 4 of the 2022
RSWDM.
3. Drainage plans and a drainage report complying with the adopted 2022 Renton Surface Water Design
Manual will be required. Refer to Figure 1.1.2.A – Flow Chart of the 2022 Renton Surface Water Design
Manual (RSWDM) to determine what type of drainage review is required for this site. The site falls
within the Flow Control Duration Standard Matching Forested Site Conditions. The site falls within the
Black River drainage basin and Rolling Hills Creek sub basin. The north end of the property contains
regulated slope areas.
4. The current Surface Water Standard Plans shall be used in all drainage plan submittals. The current
City of Renton Standard Details are available online in the City of Renton website
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton
5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will
be required to provide basic water quality treatment. Any proposed detention and/or water quality
vault shall be designed in accordance with the RSWDM that is current at the time of civil construction
permit application. Separate structural plans will be required to be submitted for review and approval
under a separate building permit for the detention and/or water quality vault.
6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new
runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated
as described in Section C.1.3 of the 2022 RSWDM. A preliminary drainage plan, including the
application of on-site BMPs, shall be included with the land use application, as applicable to the
project. The final drainage plan and drainage report must be submitted with the utility construction
permit application.
7. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design Manual
Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with
recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be
included in the report. The report should also include information concerning the soils, geology,
drainage patterns and vegetation present shall be presented in order to evaluate the drainage,
erosion control and slope stability for site development of the proposed plat. The applicant must
demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage,
or excess surface water runoff.
8. Erosion control measures to meet the City requirements shall be provided.
9. The development falls within the R-8 zone which has a maximum impervious surface area of 65% per
lot, and maximum building coverage of 50% per lot.
10. The development is subject to a surface water system development charge (SDC) fees. Fees will be
charged based on the rate at the time of construction permit issuance.
• The current SDC fee for a single family residence is $2,300 per lot.
• The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof
Renton
Transportation
1. Per City code 4-6-060 frontage improvements are required for new construction in excess of
$175,000. The proposed project fronts Morris Ave S to the west, and private property on all other
sides.
• Morris Ave S is classified as a Residential Access street. Existing ROW width is 30 feet per the
King County Assessors Map. Existing improvements include a paved roadway of
approximately 18 feet (9 feet from centerline) with the remainder unimproved. To meet the
City’s complete street standards for Residential Access streets, minimum ROW is 53 feet. Per
City code 4-6-060, minimum half street improvements shall include a pavement width of 26
feet (13 feet from centerline), a 0.5 foot curb, an 8 foot planting strip, a 5 foot sidewalk, street
trees and storm drainage improvements. Dedication of approximately 11.5 feet is required
pending final survey.
2. Refer to City code 4-4-080 regarding driveway regulations.
• A minimum separation of 5 feet is required between driveway and the property line.
• Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide
slotted drains.
• The maximum width of single loaded garage driveway shall not exceed nine feet (9') and
double-loaded garage driveway shall not exceed sixteen feet (16').
3. A shared driveway is allowed for access up to 4 lots provided at least one of the four lots abuts a
public right-of-way with at least fifty linear feet of frontage and the subject lots are not created by a
subdivision of ten or more lots. Refer to the shared driveway requirements as outlined in RMC 4-6-
060.J. Shared driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of sixteen feet; the Fire Authority may require the tract and paved surface to be up to
twenty feet wide. If a shared driveway abuts properties that are not part of the subdivision an eight
foot wide landscaped strip shall be provided between the shared driveway and neighboring
properties.
4. For dead end streets that exceed 150-feet in length an approved turnaround per RMC 4-6-060 is
required.
5. Undergrounding of all existing utilities is required on all frontages per RMC 4-6-090.
6. Street lighting is not required for a project that consists of 4 or less residential units. See RMC 4-6-060
for street lighting requirements.
7. Paving and trench restoration within the City of Renton right of way shall comply with the City’s Trench
Restoration and Street Overlay Requirements.
8. The development is subject to transportation impact fees. Fees will be charged based on the rate at
the time of building permit issuance.
• The 2023 transportation impact fee is $12,208.54 per single family home.
• The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof
Renton
General Comments
1. If frontage improvements are required, all existing and proposed utility lines (i.e. electrical, phone, and
cable services, etc.) along property frontage or within the site must be underground as outlined in
RMC 4-6-090 – UTILITY LINES - UNDERGROUND INSTALLATION. The construction of these franchise
utilities must be inspected and approved by a City of Renton inspector.
2. Adequate separation between utilities as well as other features shall be provided in accordance with
code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
3. All construction utility permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer
shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-
to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
4. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate sheets.
5. Fees quoted in this document reflect the fees applicable in the year 2023 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to the
permit type. Please visit www.rentonwa.gov for the current development fee schedule.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: April 20, 2023
TO: Pre-Application File No. 23-000081
FROM: Jill Ding, Senior Planner
SUBJECT: Finseth Short Plat
15XX Morris Ave S
(Parcel nos. 7222000281 and
7222000282)
General: We have completed a preliminary review of the pre-application for the above-referenced development
proposal. The following comments on development and permitting issues are based on the pre-application
submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The
applicant is cautioned that information contained in this summary may be subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Community & Economic Development
Administrator, Public Works Administrator, and City Council). Review comments may also need to be revised
based on site planning and other design changes required by City staff or made by the applicant. The applicant is
encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are
available online at https://www.codepublishing.com/WA/Renton/.
Project Proposal: The applicant is proposing to subdivide two existing vacant parcels located on the east side of
Morris Ave S at 15XX Morris Ave S (parcel nos. 7222000281 and 7222000282) into four lots and one storm water
tract for the future construction of single family residences. The project site totals approximately 39,750 square
feet (0.91 acres) in area. The site has a Comprehensive Plan Land Use of Designation of Residential Medium
Density and a zoning designation of Residential-8 (R-8). The proposed lot sizes are 6,978 sq. ft. for Lot 1, 7,450 sq.
ft. for Lot 2, 7,459 sq. ft. for Lot 3, and 10,875 sq. ft. for Lot 4. Access to the proposed lots is proposed via a 30-
foot wide access easement off Morris Ave S. Slopes with grades less than twenty five percent (25%) are mapped
on the project site and a high coal mine hazard is mapped approximately 97 feet off site to the south.
Current Use: The project site is currently vacant.
Zoning/Density Requirements: The subject property is located within the R-8 zoning classification. The density
range allowed in the R-8 zone is a minimum of 4.0 to a maximum of 8.0 dwelling units per one net acre. The
Residential Medium Density Land Use designation is intended to create opportunities for new single family
residential neighborhoods and to facilitate high-quality infill development that promotes reinvestment in existing
single family neighborhoods. Detached single family residential dwelling units are permitted uses within the R-8
zoning designation.
The area of public and private streets (including driveway tracts and private access easements) and critical areas
would be deducted from the gross site area to determine the “net” site area prior to calculating density. Using the
gross area of 39,750 square feet (0.91 acres), a 4-lot proposal arrives at a gross density of 4.40 du/ac (4 lots / 0.91
Finseth Short Plat
Page 2 of 6
April 20, 2023
acres = 4.40 du/ac), which is within the permitted density range; however, any public right-of-way dedication and
shared driveway access would need to be deducted to calculate net density. Calculations for minimum or
maximum density which result in a fraction that is one-half (0.50) or greater shall be rounded up to the nearest
whole number. Those density calculations resulting in a fraction that is less than one-half (0.50) shall be rounded
down to the nearest whole number. A Density Worksheet would be required at the time of formal short plat
application. The applicant would be required to demonstrate compliance with the net density requirements of
the zone at the time of formal application.
Development Standards: The project would be subject to RMC 4-2-110A, “Development Standards for Single
Family Zoning Designations” effective at the time of complete application (noted as “R-8 standards” herein)
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-8 zone is 5,000 square feet for
parcels being subdivided. Minimum lot width is 50 feet for interior lots and 60 feet for corner lots; minimum lot
depth is 80 feet. Please note that for short plats of parcels smaller than one acre, one parcel may be allowed to
be smaller than the required minimum lot size, if all other parcels meet the required minimum lot size standard
of the zone. In the R-8 zone, one parcel may be allowed to be four thousand five hundred (4,500) square feet. The
proposed shared driveway would be required to be within a tract, the applicant would be required to
demonstrate at the time of formal land use application that the proposed lots would comply with the minimum
lot size, width, and depth requirements of the R-8 zone.
Building Standards – The R-8 standards allow a maximum building coverage of 50% of the lot area. The maximum
impervious coverage in the R-8 zone is 65%. The maximum wall plate height is restricted to 24 feet, and the
buildings shall be not more than two stories. Roofs with a pitch equal to or greater than 4:12 may project an
additional six (6) vertical feet from the maximum wall plate height; common rooftop features, such as chimneys,
may project an additional four (4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., decks,
railings, etc.) shall not extend above the maximum wall plate height unless the projection is stepped back one-
and-a-half (1.5) horizontal feet from each façade for each one (1) vertical foot above the maximum wall plate
height. Detached accessory structures must remain below a height of 15 feet. The gross floor area must be less
than that of the primary structure. Accessory structures, except Accessory Dwelling Units, are also included in
building lot coverage calculations. Compliance with the building standards for the new single-family residences
would be required to be demonstrated at the time of building permit review.
Setbacks – Setbacks are the minimum required distance between the building footprint and the property line. The
required setbacks for the R-8 zone are: Front yard: 20 feet for the primary structure; Rear yard: 25 feet; Side yards:
5 feet; and Secondary Front yard: 15 feet. Corner lots required to have a front yard and a secondary front yard
are relieved of the requirement to have a rear yard; in place of a rear yard setback, the side yard setback of the
zone shall apply. Please note that lots with frontage on both a public street and a shared driveway or private
street are classified as corner lots and therefore are subject to corner lot yard standards.
Compliance with the setbacks for the proposed new single-family homes would be verified at the time of
building permit review.
Access/Driveways/Parking: Access to the proposed lots would be provided via a thirty foot (30’) wide private
access easement off Morris Ave S. The City does not permit private access easements for residential subdivisions.
The proposed access would need to be provided via a shared driveway. Shared driveways may be allowed for
access to four (4) or fewer residential lots, provided:
a. At least one of the four (4) lots abuts a public right-of-way and the street frontage of the lot is equal to or
greater than the lot width requirement of the zone;
b. The subject lots are not created by a subdivision of ten (10) or more lots;
Finseth Short Plat
Page 3 of 6
April 20, 2023
c. A public street is not anticipated by the City of Renton to be necessary for existing or future traffic and/or
pedestrian circulation through the short subdivision or to serve adjacent property;
d. The shared driveway would not adversely affect future circulation to neighboring properties;
e. The shared driveway is no more than three hundred feet (300') in length; and
f. The shared driveway poses no safety risk and provides sufficient access for emergency vehicles and
personnel.
Shared driveways shall be within a tract; the width of the tract and paved surface shall be a minimum of sixteen
feet (16'); the Fire Department may require the tract and paved surface to be up to twenty feet (20') wide. If a
shared driveway abuts properties that are not part of the subdivision, an eight foot (8') wide landscaped strip shall
be provided between the shared driveway and neighboring properties. The landscape strip shall be within a tract
and planted with a mixture of trees, shrubs, and groundcover. The shared driveway may be required to include a
turnaround per subsection H of RMC 4-6-060. The maximum grade for the shared driveway shall not exceed fifteen
percent (15%), except for within approved hillside subdivisions. The maximum driveway slopes cannot exceed
15%. If the grade exceeds 15%, a variance is required.
The maximum width of single loaded garage driveways shall not exceed 9 feet and double loaded garage
driveways shall not exceed 16 feet. Compliance with driveway standards would be verified at the time of building
permit review. Each lot is required to accommodate off street parking for a minimum of two vehicles.
The applicant shall demonstrate compliance with the shared driveway and access standards at the time of
formal land use application. Compliance with individual driveway and parking standards would be verified at
the time of building permit review.
Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project, the location
must be designated on the landscape plan or grading plan. A fence and/or wall detail should also be included on
the plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the bottom of the
footing to the finish grade at the top of the wall requires a building permit. A fence shall not be constructed on
top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the
allowed height of a standalone fence. For more information about fences and retaining walls refer to RMC 4-4-
040.
Landscaping: With the exception of critical areas, all pervious area shall have landscape treatment. Landscaping
may include hardscape such as decorative paving, rock outcroppings, fountains, plant containers, etc. Ten feet
(10') of on-site landscaping is required along all public street frontages. Where there is insufficient right-of-way
space or no public frontage, street trees are required in the front yard subject to approval of the Administrator. A
minimum of two (2) trees are to be located in the front yard prior to final inspection. A conceptual landscape plan
shall be provided with the formal land use application as prepared by a registered Landscape Architect or other
certified professional.
Significant Tree Retention: Application materials identify that there are mature trees on the site. When significant
trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are proposed to be removed, a
tree inventory and a tree retention plan along with an arborist report, tree retention plan and tree retention
worksheet shall be provided with the formal land use application as defined in RMC 4-8-120. The tree retention
plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130, Tree Retention and
Land Clearing Regulations for further general and specific tree retention and land clearing requirements.
Finseth Short Plat
Page 4 of 6
April 20, 2023
In addition to retaining a minimum of 30% of existing significant trees, each new lot would be required to provide
a minimum tree density of 30 tree credits per net acre. Tree credits encourage retention of existing significant
trees with larger trees being worth more tree credits.
TREE SIZE TREE CREDITS
New small species tree 0.25
New medium species tree 1
New large species tree 2
Preserved tree 6 – 9 caliper inches 4
Preserved tree 10 – 12 caliper inches 5
Preserved tree 12 – 15 caliper inches 6
Preserved tree 16 – 18 caliper inches 7
Preserved tree 19 – 21 caliper inches 8
Preserved tree 22 – 24 caliper inches 9
Preserved tree 25 – 28 caliper inches 10
Preserved tree 29 – 32 caliper inches 11
Preserved tree 33 – 36 caliper inches 12
Preserved tree 37 caliper inches and
greater
13
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater
than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; significant trees
over sixty feet (60') in height or greater than eighteen inches (18") caliper; and trees that shelter interior trees or
trees on abutting properties from strong winds, which could otherwise allow such sheltered trees to be blown
down if removed.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native
evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention
and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved
enhancement project within a critical area or its buffer.
Finseth Short Plat
Page 5 of 6
April 20, 2023
The Administrator may require independent review of any land use application that involves tree removal and
land clearing at the City's discretion.
The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the
Administrator's satisfaction that replacement requirements in RMC 4-4-130H1e can be met.
Tree retention standards shall be applied to the developable area, as defined in RMC 4-11-040, Definitions D, of
a property. A formal tree retention plan and tree retention worksheet prepared by an arborist or landscape
architect would be reviewed at the time of the land use application.
Residential Design and Open Space Standards: All single family residences would be subject to the Residential
Design Standards for the R-8 zone, outlined in RMC 4-2-115. Residential Design Review occurs as part of the
Building Permit Review.
Critical Areas: Slopes with grades less than twenty five percent (25%) are mapped on the project site and a high
coal mine hazard is mapped approximately 97 feet off site to the south. Slopes with grades less t han twenty five
percent (25%) are not regulated critical areas. A coal mine hazard analysis would not be required as the project
site is located more than fifty feet (50’) from a high coal mine hazard area (RMC 4-3-050B.1).
Environmental Review: Except when located in sensitive areas (such as wetland or protected slopes) or lands
covered by water, short plats of 9 or fewer residential lots are categorically exempt from Environmental (SEPA)
Review.
Permit Requirements: The proposal would require administrative short plat approval. The application would be
reviewed within an estimated time frame of six to eight weeks. The 2023 administrative short plat application fee
is $5,680.50 ($5,410.00 each plus a 5% Technology Surcharge Fee). Each modification request is $273.00 ($260.00
each plus a 5% Technology Surcharge Fee). All fees are subject to change. Detailed information regarding the land
use application submittal can be found on the City’s new website by clicking “Land Use Applications” on the
Community & Economic Development page, then “All Forms (A to Z).” The City now requires electronic plan
submittal for all applications.
Once Preliminary Short Plat approval is obtained, the applicant must complete the required improvements and
dedications, as well as satisfy any conditions of the preliminary approval before submitting for Final Short Plat
review. Once final approval is received, the plat may be recorded. The newly created lots may only be sold after
the plat has been recorded. In addition to the required land use permits, separate construction and building
permits would be required.
Public Notice: A minimum of one Public Information Sign is required for a Short Plat application. The applicant is
responsible for the procurement, installation and maintenance of the sign. Detailed information regarding the
land use application submittal requirements is provided on the City of Renton website (www.rentonwa.gov).
Fees: In addition to the applicable building and construction fees, impact fees would be required. Such fees would
apply to all projects and would be calculated at the time of building permit issuance and payable prior to building
permit issuance. The 2023 impact fees are as follows:
• A Transportation Impact Fee based on $ 12,208.54per each new detached dwelling unit.
• A Parks Impact Fee based on $3,276.44 per each new detached dwelling unit.
• A Fire Impact fee of $829.77 per each new detached dwelling unit.
• Renton School District Impact Fee is $2,911.00 per each new detached dwelling unit (plus an additional 5%
service fee).
Finseth Short Plat
Page 6 of 6
April 20, 2023
A handout listing Renton’s development-related fees is available on the City of Renton website for your review.
Note: When the formal application materials are complete, the applicant shall have the application materials
pre-screened prior to submitting the complete application package. Please contact Jill Ding, Senior Planner at
jding@rentonwa.gov or 425-430-6598.
Expiration: Upon approval, the Short Plat is valid for five years with a possible one year extension (RMC 4-7-070M).
It is the responsibility of the owner to monitor the expiration date.