Loading...
HomeMy WebLinkAboutEx_11_Advisory_NotesDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 3 LUA23-000035 ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Alex Morganroth, 425-430-7219, amorganroth@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m . and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of veget ation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division’s approval of this work is required prior to final inspection and approval of the permit. 4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is being cleared. 5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. 6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. 7. This permit is shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and /or your U.S. Fish and Wildlife Service permit. Development Engineering: (Contact: Jonathan Chavez, 425-430-7288, jchavez@rentonwa.gov) 1. See Attached Development Engineering Memo dated February 21, 2023 Exhibit 11 DocuSign Envelope ID: 57BD3737-A63F-4813-88F2-F0381C7D329D ADVISORY NOTES TO APPLICANT Page 2 of 3 LUA23-000035 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: February 21, 2023 TO: Brittany Gillia, Planning FROM: Jonathan Chavez, Development Engineering SUBJECT: Swanson Garden Meyers Parking Lot Expansion 4512 Talbot Road South LUA23-000035 I have completed a review for the above-referenced proposal located at parcel(s) 3123059069. The following comments are based on the land use application submittal made to the City of Renton by the applicant. SEWER 1. The new refuse and recycling enclosure must have a drain that is routed to the sanitary sewer. SURFACE WATER 1. There is an existing drainage covenant recorded on this parcel. Applicant must retain or propose equal mitigation for stormwater, based on the recorded covenant. In addition, Applicant must mitigate new impervious areas to the maximum extent feasible. a. Applicant is proposing to replace the existing splashblock location with a tightline connection to the existing storm system. A new splashblock will be placed at the north property line to maintain the mitigation required by the previous project, C19005266. i. Applicant must re-grade the landscape strip along the north property line to ensure that the roof runoff does not disperse on the neighboring north property. 2. A drainage report complying with the 2022 Renton Surface Water Design Manual (RSWDM) will be required. Based on the City’s flow control map, the site falls within the City’s Flow Control Duration Standard (Forested Conditions). The site falls within the Panther Creek Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. a. A drainage report by CORE Design was submitted by the Applicant, with the land use application. b. The Applicant is proposing to mitigate the new impervious surface area with a mitigation trade. 700 SF of the roof runoff will be routed to a new bioretention swale in the center of the property. 3. Storm drainage improvements along all public street frontages are required to conform to the City’s street and stormwater conveyance standards. Any new storm drain installed on or off-site shall be designed and sized in accordance with standards found in Chapter 4 of the 2022 RSWDM and shall account for the total upstream tributary area, assuming developed conditions for onsite tributary areas and existing conditions for any offsite tributary areas. 4. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide enhanced basic water quality treatment. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 5. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section DocuSign Envelope ID: 57BD3737-A63F-4813-88F2-F0381C7D329D ADVISORY NOTES TO APPLICANT Page 3 of 3 LUA23-000035 C.1.3 of the 2022 RSWDM. A preliminary drainage plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. 6. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 7. Erosion control measures to meet the City requirements shall be provided. 8. The current Surface Water Standard Plans shall be used in all drainage plan submittals. The current City of Renton Standard Details is available online on the City of Renton website. 9. The 2023 Surface water system development fee is $0.92 per square foot of new impervious surface, but no less than $2,300.00. This is payable prior to issuance of the construction permit. This fee is subject to change based on the calendar year the construction permit is issued. TRANSPORTATION 1. Frontage improvements were installed as part of a civil permit, C19005266. DocuSign Envelope ID: 57BD3737-A63F-4813-88F2-F0381C7D329D