Loading...
HomeMy WebLinkAboutR-422118V ) z 0 I- z z 0 I- Q N z ry W 00 75 0 _ �_ NV L.L Lij W z_ J o_ N N 0 N w Q UJ w U_ rZA 5 2", 4", 6-, 12-, OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION 6 5�� 10• _ 3FF�OT Te #3 BAR EP #3 E PRECAST BASE SECTION #3 BAR HOOP PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP", 12" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC.9-05.12(1) 15 PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR #3 BAR EACH NON -SHRINK APPLICATIONS IN ACCORDANCE WITH CORNER 18" MIN. STANDARD SPECIFICATION 9-20.3(2). SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION ,.,} IL PUBLIC WORKS DEPARTMENT ROOF DS PER ARCH 6" CAP W/ HOLE DRILLED FOR DOWNSPOUT 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. l 1. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 200.00 APPR ID: CATCH BASIN TYPE 1 GAZ 9/28/2018 I :45 Public Works Admi"istrawr DATE NTS COR STD PLAN 200.00 - CB TYPE 1 PIEDMONT DS ADAPTER, MODEL #SV STAINLESS STEEL BRUSHED FINISH W/ DEBRIS EXCAVATION CLEANOUT OPTION ROUND INLET ID - 4.625", OUTLET OD - 5.56" COVER PLATE OD - 7.25" HEIGHT - 18" PROVIDE (MIN) 24" SQUARE CONCRETE ENCASEMENT FROM FACE OF BUILDING TO 8" CENTERED ON DOWNSPOUT CLEANOUT ADJACENT PAVEMENT OR LANDSCAPE PFR PI AN a 2.0' MIN 8' 6$' 90° ELBOW Lq d I Op 00 0.5% (MIN) REMOVABLE 6"-45° BEND FOUNDATION FOOTING PER PLUG STRUCTURAL LOCKING METAL RING & COVER 61' ' TEE MODIFIED FOR SHALLOW/WIDE FOOTINGS CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28" MAX. 16" MAX. FLAT SLAB TOP 48", 54", 60", 72", 84, 96", 120" OR 144" EE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER 12" (TYP.) JMA.. 1" MIN"0" RING 24 2.5"MAFORCING STEEL, (TYP.) MIN. 12" GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9.03.12(3) SEPARATE BASE INTEGRALBASE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" 6D„ 5" 8" 48• 1 8" 72" 6" 8" 60" 1 12" 84" 8" 12" 72" 1 12" 96" 8" 12" 84" 12" 120" 10" 12" 96" 12" 144" 12" 12" 108" 1 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP , SOLID WALL PVC, PROFILE WALL PVC, 48" 24" 30" 24" 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48" 48" 84" 54" 60" 54" 48" 48" 96" 60" 72" 60" 48" 48" 120" 66" 84" 60" 48" 48" 144" 78" 96" 60" 48" 1 48" 1 CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) STD. SPEC. 9-05.12(1) 'STD. SPEC. 9-05.12(2) UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) AolSTD. PLAN - 201.00 PRI �PUBLIC WORKS CATCH BASIN TYPE 2 PR DEPARTMENT GAZ 9/28/2018 1 9:45 Public Works Adl-t-11 DATE NTS COR STD PLAN 201.00 - CB TYPE 2 2 1/2 D 6"-45° (1/8) BEND d d FOUNDATION FOOTING FOOTING DRAIN PER STRUCTURAL SEE DETAIL 6"SANITARY TEE MODIFICATIONS ALLOWABLE AS REQUIRED DUE TO WIDTH OF SPREAD FOOTINGS AND LOCATIONS OF FOOTING DRAIN J. 1932 First Ave ��oF W Asyl/ A Suite 201 4 z�� Seattle, WA 98101 p, 206.725.1211 f. 206.973.5344 �o�Ft /STERN � 7 engineering pIIc WWw•lpdengineering.com SS1ONAL N0. ■ 1 11 f, 2 t, ROOF DS - SEE ARCH PLANS AND SPECIFICATIONS PIEDMONT DS ADAPTER, MODEL #SV STAINLESS STEEL BRUSHED FINISH W/ DEBRIS EXCAVATION CLEANOUT OPTION ROUND INLET ID - 4.625", OUTLET OD - 5.56" COVER PLATE OD - 7.25" HEIGHT - 18" JT FILLER (TYP ALL AROUND WHEN CONCRETE IS PRESENT) STORM DRAIN CLEANOUT FLUSH W/ - / FINISHED GRAD STD CAST IRON COVER FOR PAVED AREAS CLEANOUT PER COR STD DETAIL 226.00 2.0' MIN ADJACENT PAVEMENT OR LANDSCAPE PER PLAN ' I D _j PROVIDE (MIN) 24" SQUARE CONCRETE ENCASEMENT FROM FACE OF BUILDING TO 8", CENTERED ON DOWNSPOUT CLEANOUT 6"-45° (1/8) BEND NTS ROOF DOWNSPOUT W/ CLEANOUT TTERING )LT HOLES - 3 PLACES )LALLY SPACED 120" APART ON 11/16" DIA. B.C. SKID GROOVE PATTERN DIA. PICKHOLE rLAN Vlt:W 25" DIA. 1. 3/4" 2 1/2" I 8 3/4" (TYP.) COVER SECTION VIEW 26 1/2" DIA. 25 1/4" DIA. NEOPRENE GASKET 1 1/16" 5/8" J I---- 23 318" DIA. CL OPEN 27 5/16" DIA. 34 1/8" DIA. FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5I8"A 1 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4" 1 1/16" 1/8" R1/8" GASKET GROOVE DETAIL II I " SKID GROOVE PATTERN DETAIL NOTES: 1. ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. 2. THIS COVER SHALL ONLY BE USED FOR STRUCTURES WITHIN PRIVATE DEVELOPMENTS OUTSIDE OF PUBLIC RIGHT-OF-WAY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.40 URI PUBLIC WORKS STORM ROUND FRAME AND COVER DEPARTMENT (PRIVATE) Aartin Pastuch&/13/2020 8:48 6081M1<D98B440... DATE Public Works Adm ,,i for NTS COR STD PLAN 204.40 - STORM ROUND FRAME AND COVER (PRIVATE) 3 I"HLAI VAUL GUI HIC 9" DIA -� 5/ " ❑ STORM ❑ 4" 00O❑ ❑❑ q 8-1/8"DIA 10-1/2" DIA (2) 3/8"-16 SS SOCKET HEAD CAP 15" DIA (1) OPEN PICKHOLE 1" SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE CAST IRON FRAME AND COVER, SEE NOTE 3 - V V 8" CLASS "B" ASPHALT, SEE NOTE 4 CLEANOUT RISER, SEE NOTE 2 SOIL TIGHT 45" BEND WYE SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 TO OVERFLOW STRUCTURE OR STORM MAIN PAVED AREA (TYP.) p^ EXTEND ERISER DESIGN 2" ABOVE DESIGNSIGN PONDING ELEVATION OR PER PLAN a DESIGN PONDING ELEVATION 4" COMPACTED SAND OR C GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) 000. CLEANOUT RISER, SEE NOTE 2 IJIIIL IIIII El III II FEIII I II�IIIIIII CLFANOUT RISFR L 8-13/16" DIA u7u��Np�7�i `L 5 8. FERNCO GASKETED QUIK CAP OR SIMILAR /'�' 4" STREAMBED COBBLES / PER WSDOT 9-03.11(2) I� U1 =I I I aCATFn WITHIN 111l'IT<IA/ \- MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION NOTES: 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) Aomt" STD. PLAN - 226.00 PR PUBLIC WORKS ®R0�9rAhedby: DEPARTMENT STORM SYSTEM CLEANOUT Aartin Pastucha 8/13/20 o 11,'WWAZNJW0D DATE NTS COR STD PLAN 226.00 - STORM CLEANOUT SURVEYED: SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 T DESIGNED: Y OF CIVIL PERMIT RESPONSE 0/26/2 DRAWN: R E N TO N ONE INCH DATUM PERMIT RE -SUBMITTAL 1 12/12/22CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY FLOOR AND CAPILLARY BREAK PER STRUCTURAL DRAWINGS SLOPE TO DRAIN AWAY FROM BUILDING PROPOSED GRADE PER PLAN IN 12 M771 d . p p od p COOCl>'- 0 0 6 0_ 300 660 0 660 o OOP °° >OD O0o0 OO\���\�/ O 0 O O 1 N N J CONTRACTOR TO PROVIDE TEMPORARY PROTECTION OF WASHED ROCK BACKFILL PRIOR TO PLACEMENT OF FINAL FILL LAYERS VARIES FILL AS REQ W co FOOTING_D_RAIN____ O TOP SHALL BE A O MIN OF 4" BELOW N TOP OF FOOTING N BUILDING FOOTING & WALL PER STRUCTURAL DRAWINGS. WASHED ROCK DO NOT DISTURB FOOTING 6" FOOTING DRAIN PLACED LEVEL OR BEARING ZONE WHEN WITH POSITIVE SLOPE TO OUTLET INSTALLING FOOTING DRAIN NTS FOOTING DRAIN Tl11"1 [-`1111 W , u NTS FRENCH DRAIN 8 R-422118 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING J Michael Sippo 01/27/2023 '' Q SURFACE WATER UTILITY J Farah 01 /27/2023 Im LINDBERGH HIGH SCHOOL MODERNIZATION DATE: 16 SEPT 2022 LU 16426128THAVE SE FFIELDBOOK: RENTON, WA 98058 PAGE: DRAWING NO: DRAINAGE DETAILS C 2.6 E W SHEET: 1 QU OF, 64 0_