Loading...
HomeMy WebLinkAboutR-422137N N O 0 W I-_ CO Z O r) Q Z Q Z O Q N_ Z ry W n O 75 U) 2 2 (D ry W m r) Z_ J I1[0>A Print Form Reset Form Save Form DEPARTMENT OF COMMUNITY i CITY OF AND ECONOMIC DEVELOPMENT Renton 0 TREE RETENTION WORKSHEET Planning Division 1055 South Grady Way -Renton, WA 98057 Phone: 425-430-7200 1 www.rentonwa.gov 1. Total number of trees over 6" diameter', or alder or cottonwood trees at least 8" in diameter on project site 53 trees 2. Deductions: Certain trees are excluded from the retention calculation: Trees that are dangerous2 trees Trees in proposed public streets trees Trees in proposed private access easements/tracts trees Trees in critical areas3 and buffers trees Total number of excluded trees: 0 trees 3. Subtract line 2 from line 1: 53 trees 4. Next, to determine the number of trees that must be retained4, multiply line 3 by: 0.3 in zones RC, R-1, R-4, R-6 or R-8 0.2 in all other residential zones 0.1 in all commercial and industrial zones 16 trees 5. List the number of 6" in diameter, or alder or cottonwood trees over 8" in diameter that you are proposing5 to retain4: 52 trees 6. Subtract line 5 from line 4 for trees to be replaced: (if line 6 is zero or less, stop here. No replacement trees are required) (36) trees 7. Multiply line 6 by 12" for number of required replacement inches: (433) inches 8. Proposed size of trees to meet additional planting requirement: (Minimum 2" caliper trees required for replacement, otherwise enter 0) inches per tree 9. Divide line 7 by line 8 for number of replacement trees6: (If remainder is .5 or greater, round up to the next whole number) trees 1 Measured at 4.5' above grade. Z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed landscape architect, or certified arborist, and approved by the City. 3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050. 4 Count only those trees to be retained outside of critical areas and buffers. 5 The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-17a. 6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least six feet (6) tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees. 1 H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx 08/2015 Tree Retention Worksheet reflects trees within the project's designated Limit of Work PERMIT RE —SUBMITTAL II:11S5I[`110111 SURVEYED: DESIGNED: VS DRAWN: C ID 12/2] I CHECKED: vs 1:1t�E�7:�llslll�_�,�Ga SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M TREE PROTECTION NOTES: NOTE: ALL REQUIRED TREE PROTECTION MEASURES MUST BE INSTALLED AND APPROVED BY ARBORIST PRIOR TO COMMENCEMENT OF DEMOLITION. 1. INSTALL 3" DEPTH OF COARSE WOOD CHIPS OVER ENTIRE TREE PROTECTION ZONE (TPZ) PRIOR TO INSTALLING PERIMETER PROTECTION FENCING. WATER GROUND DEEPLY BEFORE PLACING AND KEEP MULCH MOIST. DO NOT PILE MULCH DIRECTLY AGAINST TRUNK. 2. VEHICULAR MOVEMENT AND HEAVY EQUIPMENT ARE STRICTLY PROHIBITED WITHIN TPZ. PEDESTRIANS ARE TO BE EXCLUDED EXCEPT AS ABSOLUTELY NECESSARY. 3. CONSTRUCTION STORAGE IS PROHIBITED WITHIN ENTIRE TPZ INCLUDING CONSTRUCTION SUPPLIES, EQUIPMENT, MATERIALS, STOCKPILES AND DEBRIS. 4. DISPOSAL OF MATERIALS OR FLUIDS OF ANY KIND IS PROHIBITED WITHIN TPZ. 5. CONTRACTOR MUST RETAIN A CERTIFIED ARBORIST TO INSPECT AND PROVIDE SPECIFIC DIRECTION ON PRUNING BRANCHES AND ROOTS, AND RELATED WATERING, FERTILIZING, BACKFILLING AND MULCHING. PROTECTION FENCING 6 FT. TALL CHAIN LINK FENCING TO BE PROVIDED AND MAINTAINED AROUND ENTIRE PERIMETER OF TPZ. 1 %" STEEL POSTS TO BE ANCHORED IN GROUND EXCEPT OVER PAVEMENT. KEEP FENCE LOCKED AT ALL TIMES. PERMISSION OF OWNER'S REP REQUIRED FOR ACCESS WITHIN TPZ. LAMINATED TREE PROTECTION SIGNS TO BE WIRED TO FENCE NO MORE THAN 10' APART WITH TOPS 12" BELOW TOP OF PANELS. SIGNS TO BE 8 % "X 11" SIZE MINIMUM WITH TEXT IN LARGE, BOLD FONT, TO READ: "PROTECT CRITICAL ROOT ZONE AREA. NO ENTRY, SOIL DISTURBANCE, PARKING, STORAGE OR DUMPING OF MATERIALS IS ALLOWED WITHIN THIS AREA." ZONE B �UTER TP� ZONE A — CRZ � DEFINITIONS TREE PROTECTION ZONE (TPZ): AREA SURROUNDING INDIVIDUAL TREES OR GROUPS OF TREES TO REMAIN DURING CONSTRUCTION, AND DEFINED AS FOLLOWS: RADIAL DISTANCE MEASURED FROM THE TRUNK FACE OF A TREE AT THE RATE OF 1 FOOT OF PROTECTION PER ONE INCH OF CALIPER SIZE. CRITICAL ROOT ZONE (CRZ): INNER HALF OF TPZ EXTENDING RADIALLY FROM TRUNK. DBH (DIAMETER AT BREAST HEIGHT):TREE DIAMETER MEASURED AT 4.5 FEET ABOVE GROUND. PLAN ZONE A (CRITICAL ROOT ZONE — CRZ) 1. NO DISTURBANCE WHATEVER ALLOWED WITHOUT SITE —SPECIFIC ARBORIST INSPECTION AND APPROVAL OF METHODS TO PREVENT/MINIMIZE ROOT DAMAGE. 2. CUT ROOTS CLEAN. SEVER ROOTS LARGER THAN 2" DIAMETER ONLY AFTER ARBORIST INSPECTS, APPROVES THEN DIRECTS PRUNING. COVER CUT ENDS TO KEEP MOIST UNTIL BACKFILLED. 3. TUNNELING IS REQUIRED TO INSTALL LINES 3'-0" BELOW GRADE OR DEEPER. HIGH PRESSURE WATER EXCAVATION IS PROHIBITED WITHIN TOP 3 FT. OF SOIL WHERE ROOTS ARE CONCENTRATED. ZONE B ,OUTER TPZ 1. EXCAVATION MUST LEAVE AT LEAST 2/3 OF; PZ UNDISTURBED. 2. ALL TRENCHING MUST BE DONE BY HAND Oi. AIR EXCAVATION TOOL. SPOILS NOT TO BE PILED IN TPZ; BACKFILL IMMEDIATELY. �oll� TREE PROTECTION SCALE: ############ R CITY OF RENTON VASOF Planning/Building/Public Works Dept R-422137 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Michael Sippo 01/27/2023 LINDBERGH HIGH SCHOOL MODERNIZATION 16426128TH AVE SE RENTON, WA 98058 TREE INVENTORY SCHEDULE DATE: 16 SEPT 2022 FIELDBOOK: PAGE: DRAWING NO: T1.10 SHEET: OF: 37 64 C4 O O O O N N Q J 00 O 0 O O N (0 LO 00 N O O (N N A, Q 75 00 U) UJ I..L rg 4mid2 � AeccDbFace (AeccLand 130)