Loading...
HomeMy WebLinkAboutR-422164REMOVE EX. WM AS REQ'D DI CL. 52 SPOOL LENGTH AS LENGTH AS x LF REQ'D NEEDED NEEDED MJ SLEEVE W/MEGA-LUGS PROPOSED UTILITY (SEE NOTE BELOW) EX. DI OR A/C WM - - - - - . - - - - - -- ---- EX. DI OR A/C WM VERT. THRUST BLOCK DI CL. 52 SPOOL x LF REQ'D W/ REBAR STRAPS (TYP. OF 2) (TYP. OF 2) 45" BEND (MJxMJ) PROPOSED DI CL. 52 WM W/MEGA-LUGS (TYP. OF 4) ALL BELLS BETWEEN FITTINGS 12" MIN. VERT. CLEARANCE SHALL HAVE FIELD-LOK GASKETS BETWEEN UTILITY & TOP OF WM UNLESS OTHERWISE SHOWN ON PROFILE, IF CROSSING GRAVITY SEWER MIN. 18" VERT. CLEARANCE REQUIRED (SEE NOTE 2 BELOW) NOTES: 1. MEGA -LUGS SHALL NOT BE USED ON EXISTING WATER MAIN PIPE IF EXISTING PIPE IS CLASS 50 D.I. OR A.C. PIPE. MJ SLEEVE TO BE INSTALLED ON CLASS 50 D.I. PIPE. TRANSITION COUPLING TO BE INSTALLED ON A.C. PIPE. BLOCKING SHALL BE DETERMINED IN FIELD BY DISTRICT FIELD REPRESENTATIVE. 2. SANITARY SEWER SHOULD BE LOCATED BELOW WATER MAINS IF POSSIBLE. GRAVITY SEWERS MAY BE LOCATED ABOVE WATER MAINS AS LONG AS THERE IS 18" MIN. SEPARATION AND THE WATER MAIN IS CASED FOR AT LEAST 10' EACH SIDE OF THE CROSSING. 3. PRESSURE SEWER MAINS SHALL ONLY BE LOCATED BELOW WATER MAINS WITH 18" MIN. SEPARATION. WATER MAIN SHALL ALSO BE CASED FOR 10' EACH SIDE OF CROSSING. NTS SOOS CREEK STD W-92 TYPICAL UTILITY CROSSING PLAN 4"-/2„ FINISH GRADE ETAIL 3LOCKING T BOX SHALL BE NDARD WA TER ER BOX PER AIL W-17. INSTALL ON VAUL T SIDE W1 TH THE LEAST CONFLICTS. 8" MIN. ORGANIC TOPSOIL TOPSOIL PER KCC 16.82.700 PIT RUN 3" MINUS .3' MIN. 95% COMPACTON CRUSHED ROCK 5/8"-1 1 /2" NA Tl - MA TERIAL IF APPROVED BY PIT RUN 3" MINUS DISTRICT AND 90% COMPACTION CRUSHED ROCK PERMITTING AGENCY 5/8"-1 1/2" 12" MIN. 90% COMPACTION SAND -SOIL ENGINEER APPROVAL & COMPACTION TEST REQUIRED PEA GRAVEL 5/8" MINUS CRUSHED 6" MIN. 2"-4" ROCK OR SOILS ENGINEERING 90% COMPACTION OTHER MATERIAL DETAIL NEEDED 1 LISTED ABOVE NOTES: BEDDING -IN RIGHT OF WAY, DRI VEWA Y PAkKING L 0 TS, PAVED AREAS, AND NON PAVED AREAS. BEDDING FOR RIGID PIPE -NATIVE MATERIAL UNLESS JUDGED UNSUITABLE BY THE DISTRICT AND PERMITTING AGENCY. TRENCH BACKFILL, BEDDING AND MATERIAL TO CONFORM TO PERMITTING AGENCY SPECIFICATIONS AND DISTRICT STANDARDS. TRENCH WIDTHS NOMINAL PIPE DIAMETER MINIMUM EARTH MINIMUM ROCK MAXIMUM 2 18 24 36 3 18 24 36 4 18 24 36 6 21 24 36 8 24 24 36 12 28 28 40 (IN INCHES) NTS SOOS CREEK STD W-34 TYPICAL TRENCH DETAIL (OUTSIDE ROADWAY) METER SIZE VAULT SIZES CATALOG# VAULT# COVER# BASE# 3" 575-LA 575-BL 57TL-S-332P 575-BL 4" 575-LA 575-BL 57TL-S-332P 575-BL 6" 675-LA 675-ML 675-TL-30C 675-BL GENERAL NOTES: 1. PAINT ALL INTERIOR METAL INCLUDING PIPE, VALVES, AND FITTINGS WITH TWO COATS OF EPDXY AS APPROVED BY THE ENGINEER. USE TNEMEC SERIES 135 CHEMBUILD MODIFIED POLYAMIDOAMINE EPDXY. APPLY PER MANUFACTURERS INSTRUCTIONS. 2. THE ABOVE VAULT SIZES WERE SUPPLIED BY UTILTY VAULT CO. AS A REFERENCE FOR REQUIRED VAULT DIMENSIONS. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL. 3. ALL ACCESS COVERS MUST BE MARKED "WATER", AND BE LOCKING, & TRAFFIC BEARING. AS REQUIRED BY DIST. WITH THREE (3) TAPPED 5/8" HOLES (SEE DWG. 26C). SQUARE HATCH MAY BE USED, SUBJECT TO APPROVAL BY DISTRICT. 4. CLASS 52 D.I.PIPE IS REQUIRED. 5. ALTERNATE METHODS OF RESTRAINT SHALL BE APPROVED BY THE DISTRICT. MATERIAL LIST 2 2 WATERTIGHT 1O HATCH --------eASTIRON OR ALUMINUM MANHOLE GRATE AND COVER (30"x 6") SEE #3 ABOVE SEALED Y4" 90' PVC \,-,Y4" 2 O LADDER RUNGS BAST IN PLACE 3 4" GALV. BAR AT 12" O.C. OR FABRICATED ALUMINUM LADDER SECURED 5BEND ELECTRICAL AT TOP AND BOTT M. V PVC CONDUIT 3 CONCRETE VAULT SUBMIT DETAILS FOR APPROVAL. (SEE TABLE ABOVE) 4 6 1 4O METER COMPOUND WATER METER FLG. x FLG. SUPPLIED BY DISTRICT. a SO MAIN VALVE TWO EACH, AWWA, FL x MJ W/RESTRAINTS GATE VALVES WITH HANDWHEEL. MUST BE LOCATED INSIDE t�0 OF VAULT. O 6O COUPLING ADAPTER -9NE EACH, CAST IRON, (FLANGE BY MECHANICAL JOINT) COUPLING ADAPTER. O O 7D FLOOR DRAIN 4' PVC, SLOPED TO STORM SEWER OR DAYLIGHT TO DRAINAGE DITCH. 16 12" MIN ;r\- ALTERNATE: WATERPROOF VAULT W/ XYPEX. ALTERNATE MUST BE APPROVED BY THE DISTRICT CONC.SEE PIPE AND WILL BE ALLOWED ONLY IF DAYLIGHT DRAIN IS EXTENDED OVER 300 FEET. BLOCKING . '° . SLEEVE DETAIL SPOOL SPOOL PLANE -END x FLANGED D.I.P. (CL52) ADJUSTABLE PIPE �► 9O 1-1/2" VALVE ENO EA. BRASS GATE VALVES FOR BY-PASS. SADDLE SUPPORT (GRINNELL #264 10 BEND TWO EA. 1-1/2 INCH 90' BRASS BENDS. OR EQUIV.) ELEVATION 11 UNION ENE EA. 1-1/2 INCH TWO-PART UNION BRASS. 12 BY-PASS PIPE ---t-1/2 INCH BRASS PIPE AS NEEDED. PIPE SLEEVE LEAD & OAKUM OR 13 SADDLE ENO EA. 1-1/2 INCH SMITH BLAIR TYPE 313 OR EQUAL. "• EPDXY SEALANT PIPE 14 TEE 1/2"x 1-1/2" BRASS TEE. 15 BUSHING 1 1/2"x 3/4" BUSHING WITH 3/4" PLUG. 4 CEMENT DRY PACK 16 WATER MAIN CLASS 52 DUCTILE IRON PIPE WITH MEGALUG RESTRAINED JOINTS. PIPE SLEEVE DETAIL 17 WALL FLANGE TWO EACH NTS � NTS SOOS CREEK STDW-26A 4" WATER METER SOOS CREEK STDW-26A 4" WATER METER 5 MATERIALS (Revised 05-1 6-1 1) 2. 3 4. 5. DUCTILE IRON PIPE ALL DUCTILE IRON PIPE SHALL CONFORM TO SECTION 9-30.1(1) OF THE STANDARD SPECIFICATIONS. PIPE SHALL BE CLASS 52 CONFORMING TO LAYING CONDITION TYPE 2, SHALL BE LINED WITH CEMENT MORTAR PER ANSI/AWWA C104/A21.4-95, AND SHALL BE SEAL COATED. JOINTS SHALL BE PUSH -ON TYPES WITH RUBBER GASKETS, WHICH FIT INTO ANNULAR GROOVES. JOINTS AT VALVES OR FITTINGS MAY BE MECHANICAL JOINT OR FLANGED DEPENDING ON SPECIFICATION AND DRAWING REQUIREMENT. DUCTILE IRON PIPE MANUFACTURED AND DISTRIBUTED BY PACIFIC STATES CAST IRON PIPE COMPANY SHALL BE MANUFACTURED AFTER 1988. RESTRAINED JOINTS FOR -DUCTILE IRON PIPE SHALL BE U.S. PIPE FIELD LOCK GASKET SYSTEM OR APPROVED EQUAL. FITTINGS FITTINGS FOR DUCTILE IRON PIPE SHALL CONFORM TO SECTION 9-30.2(1) OF THE STANDARD SPECIFICATIONS AND MAY BE FLANGED, MECHANICAL OR PUSH -ON AS REQUIRED. FLANGED FITTINGS SHALL CONFORM TO A CLASS 125 PRESSURE RATING. MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED WITH MEGA -LUG RESTRAINING DEVICES OR APPROVED EQUAL. RESTRAINING DEVICES SHALL BE MANUFACTURED OF HIGH STRENGTH DUCTILE IRON, ASTM A536, GRADE 65-45-12. BOLTS AND CONNECTING HARDWARE SHALL BE OF HIGH STRENGTH LOW ALLOY MATERIAL IN ACCORDANCE WITH ANSI/AWWA C111/A21.11. ALL RESTRAINING DEVICES SHALL HAVE A WATER WORKING PRESSURE RATING EQUIVALENT TO THE FULL RATED PRESSURE OF THE PIPE ON WHICH THEY ARE INSTALLED, WITH A MINIMUM 2:1 SAFETY FACTOR IN ANY NOMINAL PIPE SIZE. NOTARIZED CERTIFICATION FROM THE MANUFACTURER OF THE RESTRAINT DEVICE SHALL BE PROVIDED WITH SUBMITTALS. THE EXTERIOR OF ALL DUCTILE IRON FITTINGS SHALL BE COATED WITH BITUMINOUS PAINT. FIRE HYDRANTS HYDRANTS SHALL CONFORM TO AWWA C-502, EXCEPT AS HEREIN MODIFIED. HYDRANTS SHALL HAVE A MINIMUM OF 5-1/4-INCH MAIN VALVE OPENING WITH TWO 2-1/2-INCH HOSE CONNECTIONS AND ONE 4-1/2-INCH PUMPER CONNECTION. ALL PORTS SHALL BE FURNISHED WITH NATIONAL STANDARD HOSE THREAD AND 1-1/4-INCH OPERATING NUTS THAT TURN COUNTERCLOCKWISE TO OPEN. THE PUMPER CONNECTION SHALL BE EQUIPPED WITH A 5-INCH STORZ ADAPTER MEETING OR EXCEEDING THE FOLLOWING SPECIFICATIONS. A. STORZ ADAPTER AND CAP SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARD COAT ANODIZED. :��:I:1�_117�:�1:1:i�[:l��l:>•:/1�/�l�i�L:�.`l��.Yy:���i�E.`iE:�:3i_1J_1:�/_1�11��[:>•l�leL`>A 1:1 icy_ 81=1:1.:l1411111XINF.AlMTNIIImmilk [:xe-A 1:1mWEt:]ATi9W_lI:II D. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8-INCH COATED STAINLESS STEEL AIRCRAFT CABLE. E. CAP TO BE CONNECTED AND DISCONNECTED WITH STORZ WRENCHES ONLY. TORQUE TO BE SUFFICIENT SO CAP CANNOT BE REMOVED BY HAND. HYDRANTS SHALL BE FURNISHED WITH A 6-INCH MECHANICAL JOINT OUTLET, TWO 3/4-INCH DIAMETER TIE RODS, OR MEGA -LUGS, A 6-INCH AUXILIARY GATE VALVE WITH VALVE BOX, AND A RISER TO SUIT TRENCH DEPTH AT EACH INSTALLATION. THE GATE VALVE SHALL BE FLANGED TO THE MAIN TEE. HYDRANT SHALL BE FURNISHED WITH A BREAK -OFF FLANGE ON THE BARREL AND A BREAK -OFF COUPLING FOR THE STEM. HYDRANTS SHALL CONFORM TO DISTRICT STANDARDS. ALL FIRE HYDRANTS SHALL BE M & H STYLE 929 RELIANT, MUELLER CENTURION MODEL A-423, CLOW MEDALLION OR WATEROUS PACER NO. WB-67. NOZZLES SHALL BE FITTED WITH RENEWABLE BRONZE NIPPLE LOCKED IN PLACE. MAINTAIN 3 FEET CLEARANCE BETWEEN HYDRANT AND PROPERTY OR EASEMENT LINE. TYPE 1 BLUE REFLECTIVE MARKERS AS DESCRIBED IN SECTION 9-21.1 OF THE STANDARD SPECIFICATIONS SHALL BE INSTALLED AS REQUIRED BY THE GOVERNING ROAD AGENCY. FIRE HYDRANTS SHALL BE EQUIPPED WITH STEAMER AND HOSE PORT THREADS IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL FIRE PROTECTION DISTRICT. THE HYDRANT SHALL BE CLEANSED AND PRIME COATED WITH A HEAVY-DUTY BRUSH TYPE PRIMER OR APPROVED EQUAL. ALL HYDRANTS SHALL BE PAINTED YELLOW WITH TWO TOPCOATS OF OIL RESISTANT ENAMEL, BRUSH TYPE OR APPROVED EQUAL. THE DISTANCE FROM THE HYDRANT TO THE 6-INCH GATE VALVE SHALL BE STENCILED ON THE HYDRANT WITH 2-INCH LETTERS. DURING THE CHLORINATING PROCESS FOR THE NEWLY LAID PIPE, ALL VALVES ASSOCIATED WITH THE FIRE HYDRANTS SHALL BE OPERATED WHILE THE PIPELINE IS FILLED WITH THE CHLORINATING AGENT AND UNDER NORMAL OPERATING PRESSURE. aIN=:17:11`011Weill-Al 11hl:>•IeL91M GUARD POSTS SHALL NOT BE INSTALLED WITH FIRE HYDRANT ASSEMBLIES UNLESS REQUIRED BY DISTRICT. IF GUARD POSTS ARE REQUIRED BY DISTRICT, THEY SHALL BE MADE OF REINFORCED CONCRETE, 8 INCHES IN DIAMETER, 6 FEET LONG AND BURIED TO A MINIMUM DEPTH OF 3 FEET. GUARD POSTS SHALL BE SET WITH THEIR TOPS AT THE SAME ELEVATION AS THE BONNET FLANGE OF THE HYDRANT. THE EXPOSED PORTION OF THE GUARD POSTS SHALL BE PAINTED WITH 2 COATS OF EXTERIOR CONCRETE PAINT, COLOR AS DESIGNATED BY THE DISTRICT. GATE VALVES GATE VALVES SHALL BE OF THE SIZE AND TYPE INDICATED ON THE DRAWINGS WITH BRONZE -MOUNTED RESILIENT SEAT WEDGING DEVICES CONFORMING TO AWWA C509 OR AWWA C515. VALVES SHALL BE COATED PER AWWA C550 WITH NON -RISING STEMS, OPEN COUNTERCLOCKWISE, AND BE EQUIPPED WITH AN 0-RING STUFFING BOX. VALVE END CONNECTIONS MAY BE FLANGED, MECHANICAL JOINT OR PUSH -ON AS REQUIRED. ALL FLANGE FACES SHALL BE MACHINED AND DRILLED TO STRADDLE THE VERTICAL CENTERLINE. VALVE STEM EXTENSIONS WITH PLATE WELDED TO OPERATING NUT WILL BE REQUIRED WHERE OPERATING NUT IS MORE THAN 4 FEET BELOW SURFACE. THE VALVE STEM EXTENSION TOP SHALL BE INSTALLED WITHIN 18 INCHES TO 24 INCHES BELOW FINISH GRADE AND SHALL HAVE A 2-INCH SQUARE OPERATING NUT AND SELF -CENTERING ROCK PLATE SUPPORT. LOCK DOWN SET SCREWS SHALL NOT BE USED ON VALVE OPERATING NUT EXTENSIONS. MANUFACTURER SHALL PROVIDE CATALOG DATA, NET WEIGHT, AND ASSEMBLY DRAWINGS OF ALL VALVES TO BE PURCHASED AND INSTALLED AS WELL AS AN AFFIDAVIT OF COMPLIANCE. ALL VALVES SHALL HAVE A WATER WORKING PRESSURE RATING EQUIVALENT TO THE FULL RATED PRESSURE OF THE PIPE ON WHICH THEY ARE INSTALLED, WITH A MINIMUM 2:1 SAFETY FACTOR IN ANY NOMINAL PIPE SIZE. 6. VALVE BOX VALVE BOX SHALL BE CAST IRON SERIES 940B AS MANUFACTURED BY OLYMPIC FOUNDRY OR APPROVED EQUAL WITH LID MARKED "WATER". ALL BOXES SHALL BE ADJUSTED TO MATCH THE FINISH GRADE AT THE VALVE LOCATION. ALL VALVE BOX COVERS SHALL BE PAINTED BLUE. ORIENT THE VALVE BOXES SO THE "EARS" ARE SET THE SAME AS THE PIPE DIRECTION. PROVIDE 4-INCH THICK BY 2-FOOT WIDE ASPHALT OR CONCRETE COLLAR AROUND VALVE BOX COVERS IN UNIMPROVED AREAS, LANDSCAPE AREAS AND EASEMENTS. 7. VALVE MARKER POSTS VALVE MARKER POSTS SHALL BE FURNISHED AND INSTALLED WITH EACH VALVE UNLESS THE VALVE IS LOCATED IN THE PAVEMENT OR IN A VAULT. MARKER POSTS SHALL BE CONCRETE WITH 4-INCH MINIMUM SQUARE SECTION, 42-INCH LENGTH, AND SHALL BE REINFORCED WITH ONE 3/8" X 39" BAR OF REINFORCING STEEL. MARKERS SHALL BE PLACED AT THE EDGE OF THE RIGHT-OF-WAY OPPOSITE THE VALVE OR AS DIRECTED BY THE DISTRICT WITH 18 INCHES OF THE POST EXPOSED ABOVE GRADE. THE EXPOSED PORTION SHALL BE PAINTED WITH TWO COATS OF WHITE EXTERIOR CONCRETE PAINT WITH THE SIZE OF THE VALVE AND THE DISTANCE IN FEET AND INCHES TO THE VALVE STENCILED WITH BLACK PAINT ON THE FACE OF THE POST USING A STENCIL THAT WILL PRODUCE LETTERS TWO INCHES HIGH. 8. WET TAPS TAPPING SLEEVE SHALL BE JCM 432 OR ROMAC "SST" STAINLESS STEEL SLEEVES WITH FULL COVERAGE RUBBER GASKET, OR EPDXY COATED LONG PATTERN SLEEVE, OR APPROVED EQUAL. VALVE SHALL BE A RESILIENT SEATED VALVE MADE FOR TAPPING, U.S. PIPE METROSEAL 250 OR APPROVED EQUAL. REFER TO THE GATE VALVE DESCRIPTION FOR ADDITIONAL DETAILS. SUBMITTALS REQUIRED FOR ALL WET TAP MATERIALS. 9. WATER SERVICES AND METERS NEW SERVICE LINES SHALL BE CLASS 200, HI-MOL OR APPROVED EQUAL AND SHALL CONFORM TO THE STANDARD DETAILS AND SECTIONS 9-30.6 AND 9-30.6(3)B OF THE STANDARD SPECIFICATIONS. INSTALL PLASTIC -COATED 16-GAUGE COPPER TRACER WIRE ALONG TOP OF ALL PLASTIC SERVICE PIPES. ATTACH BARE WIRE TO ANGLE AND CORPORATION STOPS. CONNECTIONS FROM PIPE TO ANGLE AND CORPORATION STOPS SHALL BE WITH COMPRESSION PACK JOINTS. METER BOXES SHALL BE AS CALLED OUT ON THE STANDARD DETAILS. METER BOXES AND LIDS LOCATED IN DRIVEWAYS OR SIDEWALKS SHALL BE TRAFFIC BEARING AS APPROVED BY THE DISTRICT. WATER SERVICES SHALL BE LOCATED BY MUTUAL AGREEMENT BETWEEN DEVELOPER, DISTRICT, AND OTHER UTILITY COMPANIES. PAINT SERVICE LOCATIONS ON CURB WITH BLUE PAINT. METER BOXES SHALL BE FURNISHED AND INSTALLED BY DEVELOPER/CONTRACTOR. WATER SERVICE SHALL BE LOCATED NO CLOSER THAN 5 FEET FROM POWER VAULTS, HAND HOLES AND LIGHT STANDARDS. ALL SERVICE LINES SHALL BE ONE -INCH MINIMUM, AND SHALL BE CONTINUOUS AND UNSPLICED FROM CORPORATION STOP TO METER AND SHALL HAVE 6 INCHES OF SAND BEDDING SURROUNDING THE SERVICE LINE. EXPANSION LOOPS ARE TO BE HELD AS FLAT AS POSSIBLE WITH NO REVERSE GRADE. WATER MAIN SERVICE SADDLE AND CORPORATION STOP WITH COMPRESSION ADAPTER SHALL BE LOCATED AT APPROXIMATELY 10° ABOVE SPRING LINE PER THE STANDARD DETAIL. THE DEVELOPER/CONTRACTOR SHALL NOT BACKFILL ANY SERVICE LINES UNTIL ALL BRASS FITTINGS ASSOCIATED WITH THAT SERVICE LINE HAVE BEEN INSPECTED AND ACCEPTED BY THE DISTRICT. EXISTING WATER SERVICES, WHICH NEED TO BE ABANDONED, SHALL BE DISCONNECTED AT THE WATER MAIN CORPORATION STOP. THE DEVELOPER/CONTRACTOR SHALL COORDINATE WITH THE DISTRICT'S FIELD REPRESENTATIVE AS REQUIRED. 10. IMPORTED GRAVEL MATERIAL PIPE BEDDING SHALL CONFORM TO SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS. FOUNDATION GRAVEL SHALL CONFORM TO SECTION 9-03.17 OF THE STANDARD SPECIFICATIONS. BANKRUN GRAVEL FOR TRENCH BACKFILL SHALL CONFORM TO SECTION 9-03.19 OF THE STANDARD SPECIFICATIONS, EXCEPT AT TRANSVERSE CUTS TO THE ROAD ALIGNMENT OR AT UTILITY CROSSINGS, WHICH SHALL BE BACKFILLED WITH CRUSHED GRAVEL SURFACING OR AS REQUIRED BY THE GOVERNING AGENCY. DEVELOPER/CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND DISPOSING OF ANY EXCESS EXCAVATED SOIL MATERIAL AT AN APPROVED DISPOSAL SITE. 11. CRUSHED GRAVEL SURFACING CRUSHED GRAVEL SURFACING SHALL CONFORM TO THE REQUIREMENTS OF SECTION 9-03.9(3) OF THE STANDARD SPECIFICATIONS. 12. ASPHALT CONCRETE PATCH AND OVERLAY ASPHALT CONCRETE SURFACING FOR PATCHING AND OVERLAY SHALL CONFORM TO SECTION 5-04.2 AND 5-04.3 OF THE STANDARD SPECIFICATIONS. ASPHALT CONCRETE SURFACING SHALL MEET CLASS 1/2-INCH, P.G. 58-22 GRADING REQUIREMENTS, OR AS REQUIRED BY THE GOVERNING ROAD AGENCY. FOR REFERENCE ONLY w 0 m O z z a 2i w J > �> z ww 0 z w� Z� 3 0 aQ o oQ o Y m E 0 0 1 o J w 00 N Q1 ['V M � L Ew O ^ LL N N -6 Q �6 N O p OMl � N N 1 cn cn a 3 U Y _ Q m 0 N W w N J - F- V) 2 > 0 N � z z z 0 w U\ z _ Q / O 06 w U) X J w W 00 z = z Q U Z � � Q _ _j Lu V 0- Q = z w m ry w o � z Q R-422164 BASE MAP SHEET 3 DRAWING OF 3 SHEET 64 of 64