HomeMy WebLinkAboutR-42380900
co
I
N
I I I I I I II
/
I I
I I I I I
Lu
I I I I
I I I I
��
LJJ
W
A
I
I I I J�
RE
W
I
ASPH
U
c)
Z
I I I I I
z
I I r\ I
Q
I
I I I
I II II II III I I I l
lr
06
U)
W
Q
c)
I
Im
�
aui
REMOVE IRRIGATION
1`
VALVES AND CONNECTED
U
C
APPURTENANCES
u
r
U)
Er
W
W
0
Lu
=
--
\ / \ _-----
--
\
W —S
SID SD SD
SD
O
W
ASPH \
W
-
w
J
1
4
Lu
Z
--
\ /
f1/
I/
r
f 1 J
( X ACID
l
I'
I\ \
S89758 50 W 290.98'
B.BR
OF WAS 10 O
7
33708
oN�
oA/SA/ti"
G
E
N
COUGHLINPORTERLUNDEEN
E
R
A
STRUCTURAL CIVIL SEISMIC ENGINEERING
T
0
R
801 SECOND AVENUE, SUITE 900 (206) 343-0460
SEATTLE, WA 98104 www.cplinc.com
= STUDIO
A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M.
CONTINUED - SEE SHEET C1.05
lE(E =16.38 6 CONC )_ 6
REMOVE EX X a I — — —
LIGHT POLE I v O
91\� I o N
\ N
s°ce co I 0 10 20 40
SOP 41596' 0/W SEP.
1 "=20'
r— / o I J
I\ I x I x I Legend
Cn L,
\ \ to X I I N 79°33'06" E - 46.81' PROPERTY LINE (�
o v oC0 ASPH v I LCO ASPH I oco ASPH SAWCUT LINE O
x
\ / i ASPH �C0 °0 Cn SDCB I co
SDCB REMOVE CURBING N
\ cn I l- • 1 RIM=20.15' I RIM=20.15' N
1EE=16.44' 6""GONG lE(E)=16.36' 6'CONC REMOVE ASPHALT PAVE
\ \ 1 S&B () I Q
\ � )RIY=20.;8' Cn I I REMOVE CONCRETE PAVE J
( / 1 \ToP(s)=115.9q0/w sff I o I
DEMOLISH BUILDING
v I I " 9 REMOVE TREE(S)
x I — Exisfin9Den��
Cn
X FENCING
M
\I \ o X I GAS GAS O
GAS MAIN/SERVICE
I II 1II Cv
I
mGM mGV XGM MGV GAS METER/VALVE QREMOVEEX C0 co
LIGHT POLE N SS SS SANITARY SEWERSD SDCB
RiM=21s' SSCOlM=_20. i )SSUH I(r
IE(E)=15.54' 6 CONC IE(S)=1358' 18'CC xa
lE(E)=12.83' 18Cl V
8"SD SD SD STORM DRAINAGE PIPE
\ y v
I n I x I SDCB IN L J r XX X Ix YD/CO/CB/CB 2/MH
R1M=20.14' I �
_ SAWCUT EX I pG o Cl) IE(E)=16.35' 6"CO I w w WATER MAIN REMOVAL
— — ASPHALT PAVING
0• " I FH FDC PlV WV F FD P WV
� o o ) y FH/FDC/PIV/VALVE
v -
S B ) 2» C I I p SCL E ELECTRICAL CONDUIT
ASPH l - v SDCB •
ASPH " R1M=20.15' U 2"" TELE T T TELEPHONE SERVICE
�I � I I IE(!N 14.01 ' 12 PVC o
a ko Z(W)=14.01' 12'PVC 5 I �/� TREE PROTECTION FENCING
x \ u.l PER COR STD DTL 507
0� I w TEMPORARY
Sox SDx 5 \ = CONSTRUCTION FENCING
P 0 1 Cn EXISTING CLASS IV STREAM
sD sD I � IsDx x � I sDx � x W
STREAM BUFFER
o — — SDMH C0CDGCC0QC1XD0C1XD0 ROCKERY REMOVAL
x I RIM =20.55' "
REMOVE EX I I IE(NE)=15.70' 8'CONC I W
LIGHT POLE I - IE(W)=13.20' 24 CONC -T I =
l IE(S)' 15.60' 12 PVC v
Z
G � x � IZ
\ i I REMOVE EX CURB I I Q
I I m AND GUTTER S I SDCB SDCB V
P 1 RIM=20.18' v RIY=20.19'
II I II m P o = .5 V I lE(E)=17.47' 6"CONC x IE(E)=16.25' 6"CONC
I I I_ RlM=2u. / / I I I I I
I I TOP( )=16.84' 0/W SFP Ii
IIII f o I
DH x ASPH ASPH
ui
II x x Z
I I I -- I
I I I I co °0 w
•°0 U
I REMOVE EX 0 1 (D
I LIGHT POLE I bjy o I o
I I Z
Aft t= Z
RIM=20. >9"
I TOP(4)=1719' .VW —SFo I I J o s°ce Q
SDCB x R1M=20.26'
I I x I I R I RIM=20.31 ' lE(=16.36' 6 PVC
1E(E)=17.59' 6'CONC
Cn 06
SAWCUT AND X I (n
I ( I (I " REMOVE EX ASPHALT
I I I 1\ \I \\ I PAVING AND CURB
y 1 n I Lu
I
o I
/ SDCB " llWlJ INr 11WIT� llWl�
I I RIM=20.15'
j(N)=15.07' 12 PVC
DE�ID I (NE)=15.28' 6 PVC 1
(E)=15.14' 12 PVC SD XX1 1 IE(N)=16.06' 12 PVC
IE W =155 12 PVC 0
1 a
I I
R-423809 =
X I \ IN COMPLIANCE WITH CITY OF RENTON STANDARDS U
DEAD �— —
" DECID t LIMI LIMIT LIMIT IMIT LIMIT U)
DEVELOPMENT ENGINEERING
r�
Wanders 05/10/2023
Lu
mom
CONTINUED - SEE SHEET C1.11 z
Call Before You Dig. 8-1-1 or 1-800-424-5555 Underground Service (USA)
SURVEYED: SCALE: DATE:
wH PACIFIC HORIZONTAL- NAvo 19M CITY OF SEATTLE SOUNDERS FC HEADQUARTERS LLJ
AS SHOWN HORIZONTAL• NAD 1983/1991 04 24 2023
DESIGNED: & TRAINING CENTER J
M LVR FlELDBOOK:
RENTON PAGE:
DRAWN: JAS • RENTON WASHINGTON
ONE INCH DATUM � DRAWING N0:
CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. DEMO PLAN C 1.08
WCA Q
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY SHEET: 1 OF: Lij
TBB I 71 r )