Loading...
HomeMy WebLinkAboutRC 20170907000018 � _ , ������������ . , , .:_f�, , r� ��I�!����Ili;l�lil���j�� f � � �� � ,► ; r � �������I�i��i��I�i��fi�il�l � ��o� ���o�oo���s III� �������� ���:=�U.�� 917l2At 7 8:d5 Af�9 RECORDING REQUESTED BY AND ��N�Ct3UN7y, wA WHEN RECORDED MAIL TO: CITY CLERK'S OFFICE CITY OF RENTON 1055 SOUTH GRADY WAY RENTON, WA 98057 DECLARATION OF COVENANT FOR MAINTENANCE AND INSPECTION OF FLOW CONTROL BMPS Grantor: Oleg and Yuliya Kalinichenko Grantee: City of Renton L2gfl1 D0SCr1pt10II: AKERS FARMS#5 BEG MOST SLY COR OF 1 TH N 01 DEG 42 MIN 40 SEC E 170.6 FT TH S 88 DEG 17 MIN 20 SEC E 87.7 FT TH N 57 DEG 16 MIN 49 SEC E 135.75 FT TO SLY LN OF BENSON RD TH SELY ALG RD MGN 16 FT TH S 38 DEG 49 MIN 06 SEC W 164.44 FT TO PT ON ELY LN OF 1 TH S 48 DEG 23 MIN 34 SEC W 155.42 FT TO BEG Additional Legal(s)on: Assessor's Tax Parcel ID#: 008700-0007 IN CONSIDERATION of the approved City of Renton(check one of the following) �residential building permit, ❑commercial building permit, Oclearing and grading permit, ❑subdivision permit,or ❑ short subdivision permit for Application File No. LUA/SWP relating to the real property ("Property") described above, the Grantor(s),the owner(s)in fee of that Property, hereby r � covenants(covenant)with City or Renton, a political subdivision of the state of Washingto�, that he/she(they)will observe, consent to, and abide by the conditions and obligations set forth and described in Paragraphs 1 through S below with regard to the Property. Grantor(s) hereby grants(grant), covenants(covenant), and agrees(agree)as follows: 1. Grantor(s) or his/her(their)successors in interest and assigns ("Owners")shall retain, uphold, and protect the stormwater management devices, features, pathways, limits, and restrictions, known as flow control best management practices("BMPs"), shown on the approved Flow Control BMP Site Plan for the Property attached hereto and incorporated herein as Exhibit A. 2. The Owners shall at their own cost,operate, maintain, and keep in good repair, thc Property's BMPs as described in the approved Design and Maintenance Details for each BMP attached hereto and incorporated herein as Exhibit B. 3. City or Renton shall provide at least 30 days written notice to the Owners that entry on the Property is planned for the inspection of the BMPs. After the 30 days, the Owners shall allow the City of Renton to enter for the sole purpose of inspecting the BMPs. In lieu of inspection by the City, the Owners may elect to engage a licensed civil engineer registered in the state of Washington who has expertise in drainage to inspect the BMPs and provide a written report describing their condition. If the engineer option is chosen, [he Owners shall provide written notice to the City of Renton within fifteen days of receiving the City's notice of inspection. Within 30 days of giving this notice, the Owners,or the engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report is not provided in a timely manner as specified above, the City of Renton may inspect the BMPs without further notice. 4. If the City determines from its inspection, or from an engineer's report provided in accordance with Paragraph 3, that maintenance, repair, restoration, and/or mitigation work is required lor the BMPs, The City shall notify the Owners of the specific maintenance, repair, restoration,and/or mitigation work (Work) required under RMC 4-6-030. The City shall also set a reasonable deadline for completing the Work or providing an engineer's report that verifies completion of the Work. After the deadline has r � passed, the Owners shall allow the City access to re-inspect the BMPs unless an engineer's report has been provided verifying completion of the Work. If the work is not completed properly within the time frame set by the City, the City may initiate an enforcement action. Failure to properly maintain the BMPs is a violation of RMC 4-6-030 and may subject the Owners to enforcement under the RMC 1-3, including fines and penalties. 5. Apart from performing routine landscape maintenance, the Owners are hereby required to obtain written approval from the City or Renton before performing any alterations or modifications to the BMPs. 6. Any notice or approval required to be given by one party to the other under the provisions of this Declaration of Covenant shall be effective upon personal delivery to the other party, or after three(3) days from the date that the notice or approval is mailed with delivery confirmation to the current address on record with each Party. The parties shall notify each other of any change to their addresses. 7. This Declaration of Covenant is intended to promote the efficient and effective management of surface water drainage on the Property,and it shall inure to the benefit of all the citizens of the City of Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be binding upon Grantor(s), and Grantor's(s')successors in in[erest and assigns. 8. This Declaration of Covenant may be terminated by execution of a written agreement by the Owners and the City of Renton that is recorded by King County in its real property records. IN WITNESS WHEREOF, this Declaration of Covenant for the Maintenance and Inspection of Flow Control BMPs is executed this a�, day of S � , 20 �� . ( ,,( , �i.�Z 7�.2��'ic-c_`���G��'fi �' GRAl�i' R, owner o�t Property ,� � � ` GRAN �, ner of the roperty STATE OF WASHINGTON ) COUNTY OF KING )ss. On this day personally appeared before me: ��� � �1-c����n'� C.h.a���, to me known to be the individual(s) described in and w'ho execute the within and foregoing instrument and acknowledged that they signed the same as their free and voluntary act and deed,for the uses and purposes therein stated. Given under my hand and �fficial seal this��day of �,\� ,20��. 1 Printed name Notary Public Notary Public in and for the State of Washington, State of Washinpto� BUNAHV TE residing at My Appointment Expi�ea Dec 24, 2019 �-��nG �. My appointment expires 1`�2C, 2�� 2,�_ EXHIBIT A - FLOW CONTROL BMP SITE PLAN TOTAL LOT/SITE AREA: 0.41 ACRES EXISTING PERVIOUS AREA: OSQFf ADDRESS 16427 BENSON RD S PROPOSED PERVIOUS AREA� OSQFf PARCEL NUMBER: 008700-0007 EXISTING IMPERVIOUS AREA: 1.580SQFf PERMIT#: 817002476 PROPOSED IMPERVIOUS AREA-5.600SOFT \ \�F'1's �o� � �'o 30' BASIC DISPERSION `.t�'q0 TRENCH WITH 25' � �S' FLOW PATH � � /�� � �. i1 ���� / / i \ ` .�''�//// I � � , , I �%� / � / � � ;'/ / � sst '%� ,, -- ,� � , �� T � � � � � . � �_ ,TYPE-30 / I - CATCH BASIN � � / � / / � / � �� � � �... - � �... � � �... � - � 1 �\�� �... � � �.. ��g� \��� / � 50' BASIC DISPERSION TRENCH WITH 25� FLOW PATH �� I �� ��,�yaf 5,�. ,( APPROVED BY: SCALE: SCALE : 1~=40� � =�--��s� �'�� �`� TITLE: DATE EXHIBIT 8 BASIC DISPERSION MAINTENANCE INSTRUCTIONS Your property contains a stormwater management flow control BMP (best management practice) called "basic dispersion," which was installed to mitigate the stormwater quantity and quality impacts of some or all of the impervious surfaces or non-native pervious surfaces on your property. Basic dispersion is a strategy for utilizing any available capacity of onsite vegetated areas to retain, absorb, and filter the runoff from developed surfaces. This flow control BMP has two primary components that must be maintained: (1) the devices that disperse runoff from the developed surfaces and (2) the vegetated area over which runoff is dispersed. Dispersion Devices The dispersion devices used on your property include the following as indicated on the flow control BMP site plan: ❑ splash blocks, ❑ rock pads, d gravel filled trenches, ❑ sheet flow.The size, placement, composition, and downstream flowpaths of these devices as depicted by the flow control BMP site plan and design details must be maintained and may not be changed without written approval from the City of Renton. Dispersion devices must be inspected annually and after major storm events to identify and repair any physical defects. When native soil is exposed or erosion channels are present,the sources of the erosion or concentrated flow need to be identified and mitigated. Concentrated flow can be mitigated by leveling the edge of the pervious area and/or realigning or replenishing the rocks in the dispersion device, such as in rock pads and gravel filled trenches. Vegetated Flowpaths The vegetated area over which runoff is dispersed must be maintained in good condition free of bare spots and obstructions that would concentrate flows. � • 1'-0" PIPE 1'-0" MIN. O.D MIN. END CAP OR PLUG ��°�°� ��� �° � �° CLEAN OUT NOTCHED GRADE BOARD �°�°� °�°�°� °°°°° �° °�°� SWEEP W/CAP OR PLUG 2'X2' NOTCHES 18' O.C. �o�o�o °>°��000 NOTES: °�°o°� �o<>�0000 �°�°�° °�°�°�°� 6' PERF. 000000 �����oo 000aoo oa���, o PIPE 1. THIS TRENCH SHALL BE CONSTRUCTED SO AS TO z o00000 � °oa PREVENT POINT DISCHARGE AND/OR EROSION. Q °°°°�° ����° TYPE I CB VNTH a a o �o�o°o 0 � o°o°o° o�°o°o�o � °a°o°o �°o°o°o° SOLJD COVER 2. TRENCHES MAY BE PLACm NO CLOSER THAN 50 � oo�o�o� Io�o�o�o� (LOCKING) FEET TO ONE ANOTHER. (100' ALONG FLOW UNE) a °o°o°o ° "�°o° 0 0 o i ��o�o 0 , � o �000�o ��o���S �o ����, 3. TRENCH AND GRADE BOARD MUST BE LEVEL AUGIN � °�°�o�! I�°�°�� f; A TO FOLLOW CONTOURS OF SITE. Z w �° J �o �" 4. GRADE BOARD SUPPORT POST SPACING AS �� REQIRED BY SOIL CONDITIONS. �� ———-� �o � �� _ 5. THE END OF EACH PIPE RUN SHALL HAVE AN °o ACCESSABLE CLEAN OUT SWEEP. PIPE END SHOULD °° BE VISIBLE OR THE LOCATION STAKE� INFLUENT GRADE BOARD PIPE (MAX DESIGN FLOW PLAN VIEW <=0.5 CfS PER TRENCH) GALV. �'—Qn ,�r_Ow BOLTS dc NUTS MIN. IP� MIN. ,�oy��P�" 1 ° 8 p� � /\\/ � o�� o oo�o�o � `6�° / o00 °°° °°000°o �/ oo� o0 0�0� �� �oo o� oo��o<>�< / °�o ��o o�o���o� i h z x °°� �°� °o°o°o; \ 2 � � /j o0o a�� �o�oo�° � 3/4"-1 1/2' NON ° ° ° ° � FRACTURED DRAIN � � o°o �°�<<�°00000 N c.�° �°o a �,�����o� � ROCK EWIV. TO WSDOT 000 � a<<�<��o��� \ � o00 ° ° �°�oo°°� / SPEC 9-03.12(5) 2'X12� PRESSURE °�° ��� < o00 �o����o � TREATED � � o� °<,�; o � � � �/ GRADE BORAD � °�°�° °o°�°�°�°� . z �°���o <�°o°o�o��>� � � �>o�� o°o�o�� �, �. 6' PERF. PIPE � o°000�o°o°o�o�o, / � .\ ,��� 4�X4� FlL7ER FABRIC SUPPORT POST (MIRAFl 140N OR EOUIV.) ��T Q� � 821 DOCK STREET, Su�1E-207 SCALE : NTS TACOAIA, WA 98402 PHONE: (253) 228-0513 WWW.DE—qVILCON CIVIL — GEOTECHNICAL � ' KALINICHENKO RESIDENCE ; i�—oss PUBLIC WORKS � DEPARTMENT ROOF DISPERSION TRENCH DETAIL KnowwhaYsbBIOW. CBII befae you dig. 4 of 4