Loading...
HomeMy WebLinkAboutR-394407I� SOLID RIM EL 347.38 d PIPE SUPPORTS (2 MIN.): 3" x .090" ALUMINUM W/ COVER 36" DETENTION PpipER DIA. PLAN LENGTH ° DETENTION TANK ACCESS (TYP) L2-,3 SOLID COVER RIM EL 348.56 d 36" DETENTION PIPE PER ° DIA. LENGTH PLAN SOLID COVER RIM EL 348.31 F1 d 36" DIA. DETENTION PIPE LENGTH PER PLAN SOLID COVER _ RIM EL 348.77 4 d L4 11 IE 345.77 8" INLET PIPE Call 3 Working Days Before You DIGI 0 - 1-800-424-5555 5/8" STAINLESS BOLTS 4a d MWS a° MWS MWS 4 7 MWS EL 345.1 = = EL 345.1 = EL 345.1 = EL 345.1 d 8" SHEAR 36" MIN. GATE DIA. (TYP) 8" OUTLET PIPE IE 342.6 0% SLOPE -F ° d ° ° d DETENTION PIPE STRUCTURAL NOTES IE 342.E 0.5' IE 342.6 IE 342.6 d IE 342.6 2.0' MI da SEDIMENT 4 IE 342.6 g IE 342.6 1. STRUCTURAL DESIGN AND CALCULATIONS FOR DETENTION PIPES TO STORAGE a BE PROVIDED BY CONTRACTOR. ° 4 2. CONTRACTOR TO EMPLOY DESIGN ENGINEERING FIRM WITH A MINIMUM OF 5 YEARS EXPERIENCE DESIGNING DETENTION PIPES d a a WITH A REGISTERED STRUCTURAL ENGINEER LICENSED IN THE 2.0' M11 41 STATE OF WASHINGTON TO DESIGN ALL COMPONENTS TO MEET a° THE "STRUCTURAL PERFORMANCE" REQUIREMENTS. THIS ENGINEER d da ° SHALL PREPARE, STAMP AND SIGN ALL REQUIRED DOCUMENTS d a a d° d d aRESTRICTOR AND SUBMIT DOCUMENTS TO CITY OF SEATTLE SAMEd PLATE WITH THIS ENGINEER SHALL ALSO APPROVE THE SHOP DRAWINGSPRIOR TO 1.29"0 ORIFICE FRAME & POLYPROPYLENE SUBMITTAL. REFERENCE SPECIFICATION SECTION 01300 FOR 54" LADDER OR STEPS OFFSET. 54" 54" 54" SUBMITTAL PROCEDURES. 3. LOCATION AND SIZES OF INLETS, OUTLETS ACCESS RISERS, NOTES: SD #25 SD J27 SD J28 SD #30 LADDERS, AND OTHER PIPE CONFIGURATION ELEMENTS SHALL BE PER CIVIL PLANS AND THE CITY REQUIREMENTS. 1. FRAME LADDER AND STEPS OFFSET: a. CLEAN OUT IS VISIBLE FROM TOP b. CLIMB DOWN SPACE IS CLEAR OF RISER NTS c. MH OPENING SHALL NOT BE PLACED DIRECTLY OVER THE TOP OF INLET PIPE SECTION A -A: DETENTION PIPE GENERAL NOTES 1) STORMFILTER BY CONTECH STORMWATER SOLUTIONS; PORTLAND, OR (800) 548-4667; SCARBOROUGH, ME (877) 907-8676; LINTHICUM, MD (866) 740-3318. 2) FILTERS TO BE SIPHON -ACTUATED AND SELF-CLEANING. STANDARD DETAIL SHOWS MAXIMUM NUMBER OF CARTRIDGES. EXACT NUMBER REQUIRED TO BE SPECIFIED ON SITE PLANS. 3 INLET AND OUTLET PIPES TO BE GROUTED INTO HOLES PROVIDED. JOINTS TO BE WATER -TIGHT. 4) STORMFILTER REQUIRES BETWEEN 2.75' AND 2.9' OF DROP FROM RIM TO OUTLET. INLET (IF APPLICABLE) AND OUTLET PIPING TO BE SPECIFIED BY ENGINEER AND PROVIDED BY CONTRACTOR. PIPES TO BE GROUTED INTO PROVIDED CORINGS BY CONTRACTOR. 5) ALL STORMFILTERS REQUIRE REGULAR MAINTENANCE. REFER TO OPERATION AND MAINTENANCE GUIDELINES FOR MORE INFORMATION. B C y 2 5'-3" 2'-4)/2" 2,-2Y2„ 3" 1/2" PVC WEIR 0ln=r- 1§;�jr - A CONCRETE COLLAR VANED INLET GRATE AND REBAR TO MEET (SOLID COVER HS20 IF APPLICABLE BY OPTIONAL) CONTRACTOR A I�� A a II ° T W STORMFILTER CATCHBASIN DESIGN NOTES STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. 2 CARTRIDGE CATCHBASIN HAS A MAXIMUM OF TWO CARTRIDGES. SYSTEM IS SHOWN WITH A 27" CARTRIDGE AND IS ALSO AVAILABLE WITH AN 18" CARTRIDGE. STORMFILTER CATCHBASIN CONFIGURATIONS ARE AVAILABLE WITH A DRY INLET BAY FOR VECTOR CONTROL. PEAK HYDRAULIC CAPACITY PER TABLE BELOW. IF THE SITE CONDITIONS EXCEED PEAK HYDRAULIC CAPACITY, AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" 18" DEEP MINIMUM HYDRAULIC DROP (H) 3.05' 2.3' 3.3' SPECIFIC FLOW RATE (gpm/sf) 2 gpm/ft2 1 gpm/ft' 2 gpm/ft' 1 gpm/ft' 2 gpm/ft' 1 1 gpm/ft' CARTRIDGE FLOW RATE (gpm) 22.5 1 11.25 15 1 7.5 15 1 7.5 PEAK HYDRAULIC CAPACITY 1.0 1.0 1.8 INLET PERMANENT POOL LEVEL (A) 1'-0" 1'-0" Z-0" OVERALL STRUCTURE HEIGHT (B) 4'-9" T-9" 4'-9" II a II ONOS II N Z 1.GENERAL TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. FOR SITE SPECIFIC DRAWINGS WITH DETAILED STORMFILTER CATCHBASIN STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH 3 ILE 11 ENGINEERED 3. STORMFILSO LUTIONS REPRESENTATIVE. www.ContechES.com WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS d J DRAWING. 4. INLET SHOULD NOT BE LOWER THAN OUTLET. INLET (IF APPLICABLE) AND OUTLET PIPING TO BE SPECIFIED BY ENGINEER AND PROVIDED BY - - - - - a - CONTRACTOR. 5. STORMFILTER CATCHBASIN EQUIPPED WITH 4 INCH (APPROXIMATE) LONG STUBS FOR INLET (IF APPLICABLE) AND OUTLET PIPING. STANDARD OUTLET STUB IS 8 INCHES IN DIAMETER. MAXIMUM OUTLET STUB IS 15 INCHES IN DIAMETER. CONNECTION TO COLLECTION PIPING CAN BE MADE USING FLEXIBLE COUPLING BY CONTRACTOR. ACCESS COVER 6. STEEL STRUCTURE TO BE MANUFACTURED OF 1/4 INCH STEEL PLATE. CASTINGS SHALL MEET AASHTO M306 LOAD RATING. TO MEET HS20 LOAD 2'-4" 2'-4" 2'-4" RATING ON STRUCTURE, A CONCRETE COLLAR IS REQUIRED. WHEN REQUIRED, CONCRETE COLLAR WITH QUANTITY (2) #4 REINFORCING BARS TO BE PROVIDED BY CONTRACTOR. N 1 INSIDE RIM INSIDE RIM INSIDE RIM 7. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE M 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 37 SECONDS. N 4"0 CLEAN OUT WITH PL 1'-0" T-1" 8. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft). O COLLAR OUTSIDE RIM INSTALLATION NOTES 1/2" PVC BAFFLE OPTIONAL SLOPED LID A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY CORNER ELEVATIONS ENGINEER OF RECORD. PLAN VIEW 0o TO BE SPECIFIED BY B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CATCHBASIN (LIFTING CLUTCHES PROVIDED). 6'-9" ENGINEER C. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. 2'-O" 2'-8" 2'-0" FLOATABLES BAFFLE 1CARTRIDGE CONCRETE CATCH BASIN STORMFILTER DATA STRUCTURE ID SD #31 WATER QUALITY FLOW RATE cfs 0.0155 PEAK FLOW RATE <1 cfs 0.0761 RETURN PERIOD OF PEAK FLOW rs 100 CARTRIDGE FLOW RATE 15 OR 7.5 m 7.5 MEDIA TYPE (CSF, PERLITE, ZPG ZPG RIM ELEVATION 348.91' PIPE DATA: I.E. MATERIAL DIAMETER INLET 348.91' - OUTLET 346.60' PVC 8" CONFIGURATION OUTLET INLET OPTIONS (AVAILABLE AT EXTRA COST): ❑ HOLE FOR OUTLET STUB OTHER THAN 12" ❑ CLEAN -OUT IN WEIR OTHER THAN 4" ❑ CORED HOLE FOR INLET PIPE ❑ DEEP OUTLET CORING ❑ OTHER:XXX 1CARTRIDGE CONCRETE CATCH BASIN STORMFILTER DATA STRUCTURE ID SD #2 WATER QUALITY FLOW RATE cfs 0.0073 PEAK FLOW RATE <1 cfs 0.0394 RETURN PERIOD OF PEAK FLOW rs 100 CARTRIDGE FLOW RATE 15 OR 7.5 m 7.5 MEDIA TYPE (CSF, PERLITE, ZPG ZPG RIM ELEVATION 347.00' PIPE DATA: I.E. MATERIAL DIAMETER INLET 347.00' - OUTLET 344.70' PVC 8" CONFIGURATION OUTLET INLET OPTIONS (AVAILABLE AT EXTRA COST): ❑ HOLE FOR OUTLET STUB OTHER THAN 12" ❑ CLEAN -OUT IN WEIR OTHER THAN 4" ❑ CORED HOLE FOR INLET PIPE ❑ DEEP OUTLET CORING ❑ OTHER:XXX 1-CARTRIDGE CATCHBASIN - PLAN VIEW 1 1-CARTRIDGE CATCHBASIN - SECTION VIEW B 1 2 B � - PERMANENT POOL LEVEL FINISHED GRADE NHHHHHHH 6'-0" (D LIFTING EYE FILTRATION = (TYP. OF 4) PERM)kNENT POOL LEVATION BAY INLET 5 WEIR WALL 2 1 /2' 5„ C.0 rnLO m "' `V STORMFILTER FLOW O0 O0 CARTRIDGE TYP. 0 1/2" PVC WEIR = Lo `" O v cl) (V FILTRATION 16i M BAY INLET TYP. CARTRID E INLET STUB 1/2" PVC BAFFLE � SUPPOR TYP. (OPTIONAL) OUTLET STUB 4"0 CLEAN OUT I 1 "6 FLOW o WITH PL Imo- 3'-0" KIT TYP. OUTLET PIPE Ur UG OUTLET PIPE 2-0 FROM FLOWKIT 1-CARTRIDGE CATCHBASIN -TOP VIEW 1 CLEANOUT I CATCHBASIN FOOT INSIDE 1 ACCESS PLUG B fJ 3�4 3 ON WEIR WALL (TYP. OF 4) OUTSIDE (TYP. OF ) FOOT TYP. OF 4) 2-CARTRIDGE DEEP CATCHBASIN STORMFILTER DATA STRUCTURE ID SD #29 WATER QUALITY FLOW RATE cfs 0.0249 PEAK FLOW RATE <1.8 cfs 0.1338 RETURN PERIOD OF PEAK FLOW rs 100 CARTRIDGE FLOW RATE m 7.5 MEDIA TYPE CSF, PERLITE, ZPG, GAC, PHS ZPG RIM ELEVATION 348.20' PIPE DATA: 1 I.E. IDIAMETER INLET STUB 348.20' - OUTLET STUB 346.30' 8" CONFIGURATIONS OUTLET 101 10 OUTLET INLET OUTLET OO INLET INLET OO INLET INLET SLOPED LID NO SOLID COVER NO NOTES/SPECIAL REQUIREMENTS: 2-CARTRIDGE DEEP CATCHBASIN STORMFILTER DATA STRUCTURE ID SD #26 WATER QUALITY FLOW RATE cfs 0.0239 PEAK FLOW RATE <1.8 cfs 0.1249 RETURN PERIOD OF PEAK FLOW rs 100 CARTRIDGE FLOW RATE m 7.5 MEDIA TYPE CSF, PERLITE, ZPG, GAC, PHS ZPG RIM ELEVATION 347.22' PIPE DATA: I I.E. DIAMETER INLET STUB 347.22' OUTLET STUB 344.90' 8" CONFIGURATIONS OUTLET OO OUTLET INLET OUTLET OO INLET INLET OO INLET INLET SLOPED LID NO SOLID COVER NO NOTES/SPECIAL REQUIREMENTS: 1-CARTRIDGE CATCHBASIN - SECTION VIEW A 1-CARTRIDGE CATCHBASIN - SECTION VIEW C 1 2 SECTION A -A SECTION B-B R-394407 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NT CONCRETE CATCHBASIN STORMFILTER - 1 CARTRIDGE UNIT 2 CONCRETE CATCHBASIN STORMFILTER - 2 CARTRIDGE UNIT 3 FAnn MENT ENGINEERING �' wler 07/13/2017 SURFACE WATER UTILITY J. p ADDENDU 3 4 28 17 rStraka 07>/14/2017 � of was�i� 4 ADDENDUM 4 5 5 17 SURVEYED: SCALE: VERTICAL. NAVD 1988 1932 First Ave �w , c, HORIZONTAL: MAD 1983/1991 SUNSET COURT APARTMENTS 5/5/2017 Suite 201 N �� te' z %� 2 PERMIT REVISIONS 5 5 17 DESIGNED: 1 -20 p CITY OF FlELDBOOK: Seattle, WA 98101 CONFORMED SET 5 19 17 Lip RENTON 1144-1158 HARRINGTON AVE NE p, 206,725. �\V, 4 PERMIT REVISIONS 6 29 17 ��% RENTON WA 98056 PAGE. I ONE INCH DATUM i DRAWING N0: � m'j.f. 206.973.��►,NTECH �� FINAL PERMIT SET 13 17 AT FULL SCALE Planning/Building/Public Works De t % I.. /� ENGINEERED SOLUTIONS LLC ASS AL ��Gti Th=5�I III M N El GINEERED SOLUTIONS LLC IF NOT ONE INCH P C ` • 1 enll�l*I"Il. WWWi����I�i�tACf',S�ite400EWesChester,OH45069 ,,®1 N0. REVISION ""`°"`°" 1Y' DATE �gp2gC6Atr Poe r, �ite400, Wes Chester, OH 5069 SCALE ACCORDINGLY DRAINAGE SECTION AND DETAILS SHEET: 7 OR 90, H H I.J V, H Z W m H o� Q IL Q iMM- cr 0 0 E- W Z