Loading...
HomeMy WebLinkAboutR-3944202 IRRIGATION SCHEDULE 3 5 NAKANO C A SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY HUNTER MP2000 PROS-06-PRS40-CV 9 SHRUB ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC ON PRS40 BODY. HUNTER MP3000 PROS-06-PRS40-CV 9 SHRUB ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC ON PRS40 BODY. HUNTER MP CORNER PROS-06-PRS40-CV 1 SHRUB ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. Q Q Q HUNTER MP1000 PROS-12-PRS40-CV (2) 20 SHRUB ROTATOR, 12" (30.48 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC ON PRS40 BODY. HUNTER MP2000 PROS-12-PRS40-CV (2) 7 SHRUB ROTATOR, 12" (30.48 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC ON PRS40 BODY. HUNTER MP CORNER PROS-12-PRS40-CV (2) 4 SHRUB ROTATOR, 12" (30.48 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE. T=TURQUOISE ADJ ARC 45-105 ON PRS40 BODY. VALVE CALLOUT # VALVE NUMBER #" # VALVE FLOW VALVE SIZE IKKIUA I IUN NU I L5 1. SEE DETAIL SHEETS L103 THROUGH L106 FOR ADDITIONAL REQUIRED EQUIPMENT. 2. MAINLINE PIPE SIZE SHALL BE 2". MINIMUM ALLOWABLE SIZE OF LATERAL PIPE IS 3/4". 3. VALVES, MAIN LINES, LATERAL LINES, AND POINT OF CONNECTION ARE SHOWN SCHEMATICALLY FOR GRAPHIC PURPOSES. IRRIGATION EQUIPMENT SHALL REMAIN CLEAR OF ALL PAVEMENT, WALLS, TREES, AND OTHER EXISTING AND PROPOSED SITE ELEMENTS UNLESS SPECIFICALLY NOTED ON THE PLANS OR DIRECTED BY THE LANDSCAPE ARCHITECT. 4. SLEEVING IS REQUIRED FOR ALL IRRIGATION LINES AND CONTROL WIRES UNDER NEW AND EXISTING PAVEMENTS, WALLS, CURBS, ETC. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF SLEEVING INSTALLATION AND SPECIFIC LOCATIONS FOR COMPLETE INSTALLATION OF WORK. ALL SLEEVING SHALL BE SCHEDULE 80 PVC AND SIZED TWICE THE DIAMETER OF INSERTED PIPE AND MIN. 3"0. 5. ALL PIPE SHOWN UNDER PAVING ADJACENT AND PARALLEL TO PLANTED AREAS IS SCHEMATIC AND INTENDED TO BE PLACED IN THAT PLANTING BED. 6. MAIN LINE PIPING LAYOUT, SLEEVES, AND VALVE LOCATIONS SHALL BE STAKED IN FIELD BY CONTRACTOR. STAKING AND PRESSURE SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 7. VERIFY STATIC WATER PRESSURE AT POINT OF CONNECTION PRIOR TO BEGINNING WORK. SUBMIT RESULTS TO OWNERS REPRESENTATIVE IN WRITING PRIOR TO INSTALLATION OF WORK. 8. SET VALVE BOXES SQUARE TO ADJACENT BUILDING OR PAVING. DETAIL Ne EEG SYMBOL TRANSITION LATERAL LINE SYMBOL U Z ED 121911 EC] MANUFACTURER/MODEL/DESCRIPTION 1:�:7��:Z�]�l�Z�l�]:QI�t•17 ELECTRIC DRIP ZONE VALVE KIT: 1" 700 ULTRAFLOW INLINE VALVE, FILTER, MEDIUM FLOW REGULATOR & FITTINGS AREA TO RECEIVE DRIPLINE N ETAFI M TLCV-04-12 (18) TECHLINE PRESSURE COMPENSATING LANDSCAPE DRIPLINE WITH CHECK VALVE. 0.4GPH EMITTERS AT 12.0" O.C. DRIPLINE LATERALS SPACED AT 18.0" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. 17MM. MANUFACTURER/MODEL/DESCRIPTION IRRITROL 700 WITH OMR-100 ELECTRIC REMOTE CONTROL VALVE, WITH OMNI-REG 5-10OPS1 REGULATOR ISOLATION (BALL) VALVE, SIZE PER WIUE IRRITROL TC-24-EX-R HYBRID CONTROLLER, 24- STATION, OUTDOOR MODEL, WITH PLASTIC LOCKING CABINET. CLIMATE LOGIC COMPATIBLE, AND REMOTE -READY. IRRITROL RS1000 WIRELESS RAIN SENSOR. MOUNT AS NOTED OR APPROVED, USE CONTROLLER POWER OR OPTIONAL TRANSFORMER. IRRIGATION LATERAL LINE: PVC SCHEDULE 40 BLU-LOCK PIPE, AS MANUFACTURED BY HYDRO RAIN, 1 /2" TO 1", THEN PVC CLASS 200 FOR 1-1/4" AND LARGER. ONLY LATERAL TRANSITION PIPE SIZES 1" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 3/4" IN SIZE. IRRIGATION MAINLINE: PVC SCHEDULE 40 PVC SCHEDULE 40 IRRIGATION PIPE. PIPE SLEEVE, SEE NOTE 4 (5) SIMMON 812LF FROST PROOF YARD HYDRANT OR APPROVED EQUAL POINT OF CONNECTION 9. ALL PLANTED AREAS TO BE IRRIGATED AS INDICATED. CONTRACTOR TO MAKE ANY AND ALL REQUIRED ADJUSTMENTS TO THE IRRIGATION PLAN TO ASSURE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY. SEE CORRESPONDING LAYOUT AND PLANTING PLANS FOR PRECISE PLANTING LAYOUT. 10. PLACE ALL HEADS 4" FROM CURBS, WALKS, PAVED AREAS, AND STRUCTURES. 11. INSTALL CONTROLLER IN THE ELECTRICAL ROOM ON BUILDING 1. ALL ELECTRICAL WIRES, VALVE WIRES, COMMUNICATION CABLES AND CONDUIT NECESSARY TO INSTALL CONNECTIONS BETWEEN AUTOMATIC CONTROL VALVES AND CONTROLLER ARE THE RESPONSIBILITY OF THE CONTRACTOR. 12. ELECTRICAL POWER IS REQUIRED FOR THE CONTROLLER AND CONTROL COMPONENTS. 13. MAINLINE SHALL BE 24" MIN BURIAL AND ALL LATERAL LINES SHALL BE MIN. 18" BURIAL. PLACE NO ELLS OR TEES BENEATH PAVING. 14. ALL WORK WITHIN THE CRITICAL ROOT ZONES OF EXISTING TREES SHALL BE IN ACCORDANCE WITH TREE PROTECTION SPECIFICATIONS. TRENCHING BY HAND IS REQUIRED WITH DRIPLINE OF EXISTING TREES. TRENCHES HAVING EXPOSED TREE ROOTS SHALL BE BACKFILLED WITHIN 24 HOURS UNLESS ADEQUATELY PROTECTS BY MOIST SOIL OR MULCH AS APPROVED. 15. LOCATE RAIN SENSOR PER PLAN. FINAL INSTALLATION DIRECTED BY LANDSCAPE ARCHITECT IN THE FIELD. 16. RUN TWO SPARE WIRES TO THE FURTHEST TWO VALVE CLUSTERS. PASS THROUGH EACH VALVE CLUSTER ON THE SITE AND PROVIDE ONE LOOP (24") IN EACH/ALL CLUSTER MANIFOLDS. QTY 16 24,426 S.F. QTY 5 10 1 VALVE SCHEDULE DETAIL ri L105 DETAIL 6 L103 NUMBER MODEL SIZE TYPE GPM PRECIP Al IRRITROL 700 WITH OMR-100 3/4" SHRUB ROTARY 1.87 0.30 in/h A2 IRRITROL 700 WITH OMR-100 1" SHRUB ROTARY 7.94 0.39 in/h A3 IRRITROL 700 WITH OMR-100 3/4" SHRUB ROTARY 4.16 0.31 in/h A4 IRRITROL 700 WITH OMR-100 1" SHRUB ROTARY 2.40 0.41 in/h A5 IRRITROL 700 WITH OMR-100 1" SHRUB ROTARY 14.18 0.47 in/h B1 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 7.75 0.45 in/h B2 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 10.08 0.45 in/h B3 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 8.30 0.45 in/h B4 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 6.14 0.45 in/h B5 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 5.29 0.45 in/h B6 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 8.37 0.45 in/h B7 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 6.48 0.45 in/h B8 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 7.13 0.45 in/h B9 IRRITROL 70ODK-1 -MF 1 " AREA FOR DRIPLINE 7.31 0.45 in/h B10 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 9.46 0.45 in/h 311 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 4.62 0.45 in/h E312 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 9.59 0.45 in/h B13 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 6.01 0.45 in/h B14 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 3.37 0.45 in/h B15 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 6.46 0.45 in/h B16 IRRITROL 70ODK-1-MF 1" AREA FOR DRIPLINE 8.43 0.45 in/h IN COMPIANCE WITH CITY OF RENTON STANDARDS LANDSCAPE ARCHITECTS 853 Hiawatha Place S. Seattle, WA 98144 Tel: 206.292.9392 www.nakanoassociates.com architect Printed 2.13.18 D Schemata Workshop, Inc. 1720 12th Avenue Seattle, WA 98122 CONTACT: Grace Kim, AIA v (206) 285.1589 e grace@schemataworkshop.com C owner Sunset Court LLLP 2900 NE 10th St Renton, WA 98056 CONTACT: Mark Gropper v (425) 226.1850 Sunset Court Apartments 1124-1158 Harrington Ave NE Renton, WA 98056 PRINT DATE 5/19/2017 PROJECT ISSUE DATES NOVEMBER 25, 2015 SCHEMATIC DESIGN JANUARY 20, 2016 SITE PLAN REVIEW SEPTEMBER 14, 2016 DESIGN DEVELOPMENT DECEMBER 2, 2016 BUILDING PERMIT DECEMBER 22, 2016 BUILDING PERMIT ACCESSORY STRUCTURES MARCH 1, 2017 PERMIT REVISIONSQ MARCH 28, 2017 BID SET APRIL 13, 2017 ADDENDUM #1 APRIL 20, 2017 ADDENDUM #2 A APRIL 28, 2017 ADDENDUM #3 MAY 5, 2017 ADDENDUM #4 A MAY 5, 2017 PERMIT REVISIONS 0 MAY 19, 2017 CONFORMED SET JULY 13, 2017 FINAL PERMIT SET NOTE: FULL SCALE SHEET SIZE IS 22" x 34" 1508 Author: 10, PG Checker: JY A IRRIGATION SCHEDULE R-394420 L 02 2 3 5 Copyright NAKANO ASSOCIATES