HomeMy WebLinkAboutR-390708NOTE: I'll- O m co O 0 W w w w z z w J J1 �I w Cn z W W - w 01 0 (SOUTH) o a 1 30' a- z v DEDICATED AS PUBLIC R/W 1 1 5 1 1 14.5' 15.5' 15' 72% MAX. 2% 5' SIDEWALK PER-/ C.O.R. STD. PLAN 102 8' LANDSCAPE STRIP VERTICAL CURB 8c GUTTER PER C.O.R. STD PLAN 101 A PORTION OF THE SE 1/4, SECTION 10, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON THICKENED EDGE 4" MIN. CLASS "B" ASPHALTIC CONCRETE PAVEMENT- 2-2" LIFTS REQUIRED 6"MIN. CRUSHED SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE TO BE DETERMINED BY FIELD CONDITIONS BY GEOTECHNICAL ENGINEER. NE 6th STREET ROAD SECTION SECTION E-E, LOOKING WEST FD MIC CONC MON W/BRASS DISC DN 0.3' 51 LF. 12" D.I.@S=1.05% H YD a° NO a6 �• xwv a ° v xa ► F / 6,tih S88- S MH R M=46 6 ON N W R CHA 41 216 ha + a PP us�2 6°�� W PW Z CURB RETURN TABLE R=25.00' C2 L=38.64' 0=88°33'47" PC=13+ 13.91, 13.00' LT. TBC=455.95 DELTA/2 TBC=456.15 PT=23+07.20, 10.50' RT. TBC=456.35 R=25.00' C3 L=39.93' 0=91 °30' 16" PC=32+75.80, 23.86' RT. TBC=461.53 DELTA/2 TBC=461.70 PT=20+50.04, 20.50' RT. TBC=460.95 °6 DI 12" =460.26� yI.,°j z N11 � �o Q -I �o CI 41 Q 00I rn 0 X wl°° �k oe x = 1 I I I DEDICATED PUBLIC R/W WIDTH VARIES (SOUTH) WIDTH VARIES VARIES _j_ VARIES 2% MAX. 5' SIDEWALK PER C.O.R. STD. PLAN 102 8' LANDSCAPE STRIP / VERTICAL CURB & GUTTER J PER C.O.R. STD PLAN 101 STA. 20+00.00, NE 6th STREET STA. 33+22.58, HOQUTAM AVENUE NE IE=459.69 xa6 CONNECT TO EXISTING ° W/ROMEX COUPLING R=10.00' w w w o' z � J U)�w I � � o z w z' EXISTING R/W 1 26.01 ' (NORTH) 21.0' R/W 1 6' 14' ASPHALT 2% (EXISTING) SAW CUT LINE 4" MIN. CLASS "B" ASPHALTIC CONCRETE PAVEMENT- 2-2" LIFTS REQUIRED 6"MIN. CRUSHED SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE TO BE DETERMINED BY FIELD CONDITIONS BY GEOTECHNICAL ENGINEER. NE 6th STREET ROAD SECTION SECTION D-D, LOOKING WEST �4 CB#7, TYPE 1 RIM=457.88 IE=454.47, 12"(E) (PUBLIC) THICKENED EDGE xt�, B C eFS88°21'18"E F (C) 21 +00 j N88°20'35"W (L ) - - - - _ _ _ _ _ _PROPERTY LINE � PROPOSED 8" W.M. ��• N Z5 AREA TO BE DEDICATED AS PUBLIC R/W ax o � a STA. 23+08.38, NE 6th STREET =1NT'X ILWACO AVENUE NE AIM=455 r 1 0" PEP N=451 EX. ADA RAMP 0 123LF., 12" SD@S=1 .28% Ss — (PU (PUBLIC) RIM=456.03 LUM 8" CONC N/SE ❑EF„ D CTR CHAN=4 91 O ��l 4S h G S �y �S3 ah �f > q6(o 11 NE 6th STREET �61 a ^ a PROPERTY LINE C3 4NC PIPE r < o--459. 38 A E 0 BEGIN DEPRESSED BACK OF CURB 1 END DRPRESSED BACK OF CURB STREET LIGHTS (TYPICAL) i -s 30. CONNECT TO EX. CMP PIPE W/ROMEX COUPLING SEE STREET LIGHTING PLANS STA. 21 +85.26, 20.50' RT. VERTICAL GRADE BREAK @VERT. CURB AND GUTTER GRADING ADA RAMP SE CORNER NE 6TH STREET & HOQUTAM AVENUE NE SCALE: 1 "=5' W z LLJ wl Q L O U 4 6° Q 8 ° 0 > > ahO 1013 • 456.31 a 0 J i I a`� /\ PK NAZI / ti ^a �•�SET PK a W SHER "1502 x01 xah65 �• 22+0 ..... �� L-J - - - - - -------23+0 ® 4. a 4.. a. e a ad G D _ �6 SEE RAMP ENLARGEMENT SHEET #13 STA. 22+02.09, 20.50' RT. HORIZ. ANGLE POINT @VERT. CURB AND GUTTER IP BACK OF CUR BC) ELEVATIONS EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 811 CONSTRUCTION NOTES OA INSTALL 16' DRIVEWAY APPROACH R1 B PER STD. PLAN # 104.3 OINSTALL STREET SIGN PER DWG. NAME G013 ABOVE "STOP SIGN" STREET NAMES "NE 6th STREET" AND "HOQUTAM AVE. NE" OC INSTALL MUTCD R1-1 "STOP" SIGN W/16" THERMOPLASTIC STOP BAR. STOP BAR EAST OF SIGN. ALL CATCH BASIN GRATES SHALL BE RECTANGULAR VANED GRATES PER C.O.R. STD. PLAN 204.20 UNLESS OTHERWISE SPECIFIED. NOTE: GRIND AND OVERLAY LIMITS AND TRENCH RESTORATION SHALL BE PER C.O.R. STD. PLANS H-032 AND H-032.1 NOTE: ALL GRADING NE 6TH STREET HALF STREET FRONTAGE SHALL BE COMPLETED ON SITE. CB#6, TYPE 1 A4 RIM=455.85 IE=452.90, 12 W) IE=452.88, 12" SE) (PUBLIC) IE io urtr IE 18" CPEP N=449.52 ,EX. ADA RAMP NE 6th STREET -- Q_ C 2� Ln o n STA. 13+48.47, ILWACO PLACE NE STA. 23+44.32, NE 6th STREET 7 CIO: 4 obh EX. ADA RAMP ill SEE SHEET 6 STA. 23+02.20, 10.50' RT. '\\ HORIZ. ANGLE POINT .° @VERT. CURB AND GUTTER m r- N 00 M 00 m 00 Cb m O CO O CO 6 CID cl� In In Co In Co In In In LO In C6 C6 C6 CO 465 465 PROFILE EXISTING - - - - _ ------- @ PROPERTY LINE :(N) PROFILE TBC I 460 % ' - - - - = - =2.31 7 - - (TOP BACK OF CURB) 460 .............. ............. ......�..... ............. ..................... - - _ _ _ _ _...................................... ..................................................... ....................... ---_ -1.217. w:w :. �1.........:.........455 ..455.....��w C;.. cn z .............:....... ...........:...............:............... 123LF. 12 : LOPE@5=1.28% w w z � Q (PUBLIC) O j w � w z N -1 w Q 450 j............. XIS NE :6th .................... STREET .... w Zl.o......:............... 450 p z = „ HORIZONTAL SCALE: 1 =2:0 00001� 1� •• C B 6 TYPE 1 X Q RIM=455.85 20 00 VERTICAL SCALE: 1 "=5' Ln J IE=452.90, 12::m z -II � m IE=452.88, 12 ) L 21 +00 c� 0 � 1w a_ � - .� 22+00 (PUBLIC): 23+00 ENGINEERS �y°F As °P� / / SUI7VEYED: SCALE: VERTICAL; NAVD ,988 OFFE ° P`� W ly N 5 INDICATE DEDICATION OF PUBLIC ROW D.L.O. 04 a4 1 HORIZONTAL: NAD 1983/1991 A�> 4 AS-BUILTS D.L.O. 12/18/18 DESIGNED: O CITY OF 13932 SOUTHEAST 159TH PLACE - 3 SIDEWALK RE -ALIGNMENT FOR EX. TREE D.L.O. 7/12/18 D.L. OFFE, P.E. '- RENTON RENTON, WASHINGTON 98058 ° ° ° 2 FIELD CONDITIONS W/EX. W.M. CONFLICT D.L.O. 3/05/18 DRAWN: • PHONE: 425-260-3412 ��°°.p 27460 ° ONE INCH DATU M ��c/STE����,� 1 EXISTING TREE REMOVED IN FIELD D.L.O. 1/15/18 CHECKED: IFAT FULL NOT ONECINCH Planning/Building/Public Works Dept. CONTACT: DARRELL OFFE, P.E. N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY 04/04/2019 44 AS -BUILT 12-12-2018 GRAPHIC SCALE 0 10 20 40 1 inch = 20 feet CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED BY OFFE ENGINEERS, PLLC AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY AND WATER SYSTEM. FIELD VERIFIED INVERT AND RIM ELEVATIONS WERE PROVIDED BY TERRANE SURVEYING, INC., ON DECEMBER 10, 2018. THE ON -SITE PRIVATE STORM DRAINAGE AND PUBLIC/PRIVATE WATER AND SEWER SYSTEMS WERE INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND THE DOCUMENTED FIELD REVISIONS AND FUNCTION AS INTENDED. RECORD DRAWINGS R-390708 IN COMPLIANCE WITH CITY OF RENTON STANDARDS co LO T A, u co M T 0 T Q J �i C) CD i ME i1 DATE: O MEAD SHORT PLAT 04/04/2019 = TUSCANY CONSTRUCTION, LLC OK: PAGE: NE 6th STREET PAGE: DRAWING NO: 522 HOQUTAM AVENUE NE W RENTON, WASHINGTON SHEET: Q GF:20