HomeMy WebLinkAboutW-395504I ` N V J Z 5O 5G G O U Z O I- Z W rr tii Q z J LL WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAYBE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. B. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. STD. PLAN - 300.0 n * PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2O10 MARKER � a TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) MARKER o I o a I FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) HYDRANT MARKERS 4„ RAISED PAVMENT MARKER TYPE 88 AB STIMSONITE TWO-WAY (BLUE) MARKER a T ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET MARKER o FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) TY ° STD. PLAN - 310.3 • PUBLIC WORKS �'•` �` DEPARTMENT HYDRANT MARKER LAYOUT ZN`f0 L EXISTING WATER LINE PLAN VIEW TESTING DETAIL n ±8 FT - O NEW WATER LINE �Lw 14 VERTICAL CROSS(MJxFL) FOR PDLYPIGGING ONE BLIND FLANGE ❑N TOP WITH 2'TAP & 2'PLUG ONE BLIND FLANGE ❑N BOTTOM ONE (MJ) PLUG WITH 2' TAP & 2' TEMPORARY BLOW--:1 TEMPORARY BLOCK CUT -IN (BY CITY FORCES) TEE (FLxFU W/ CONC. BLOCK 3- GATE VALVES (FLxMJ) 2- SOLID SLEEVES (MJ) DR RO-MAC COUPLINGS 1- PLUG (MJ) W/2'TAP & TEMP. BLOW -OFF TEMP. BLOCK EXISTING WATER LINE EXISTING WATER LINE FINAL CONNECTION DETAIL AFTER ALL TESTING, CLEANING BY PDLYPIG, AND DISINFECTION, REMOVE TEMP BLOCK & BLOW-0FF & CONNECT WITH SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTION BY CITY FORCES MT.M, UIPM LINE PUBLIC WORKS CONNECTION TO WATER MAIN STD. PLAN - 300.4 DEPARTMENT CUT IN -LINE TEE & THREE VALVES MARCH 2O10 CITY PRIVATE PIPING PIPING 1-1/2" AND 2" WATER SERVICE DETAIL z z F IN UNIMPROVED CAUTION: VALVE BOX SHOULD NOT REST ON 12 w RIGHT-OF-WAY INSTALL METER w BOX 10 AT PROPERTY LINE WITH PIPE. LATER COMPACTION IN AREA OF VALVE BOX a_ 0 12" LONG COPPER TAILPIECE I COULD CAUSE THE BREAKAGE OF THE SERVICE. a a 12" MAX. ZX ZX 0 ¢, 4 LEAVE EXPOSED: - 0 MU 7 NM N.0 12„ BY PASS NOT ALLOWED FOR IRRIGATION METERS 1 2 3 6 (71 7 _ 5 CRUSHED ROCK a BASE TO SUPPORT A A VAULT. _ DRILL '2' CIA. HOLE FOR TOUCHREAD DEVICE QUICK -JOINT COUPLING x MIPT CAST IRON OR DUCTILE IRON WATERMAIN 2-1/2" MIN. FROM NEAREST NOTE: AND FRONT EDGE OF PIT LID THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS -� THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. TYPICAL RIB MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK BETWEEN CURB &SIDEWALK A. 2" tapped tee on new water main. 1. 2" topped tee on new water main. PP 4" I n X with threaded (MIPT). �. o g 2" brass nipple t t Boded ends ( ) 2. 4" Ion X 2" brass nipple with threaded ends (MIPT). g pp ( ) 3. 2" resilient seat gate valve with threaded ends, square operating nut, 3. 2" resilient seat gate valve with threaded ends, square operating nut, and and valve nut extension if required (see standard detail 330.1). valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular 1, Two piece cast iron valve box. Standard 8" top section with regular base base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x section, length to fit, "lug" type cover. FIPT).;' 2" X 1-1/2" hex brass bushing (MIPT x FIPT). 2 each 1-1/2" brass or 5. 2 each 2" brass or bronze nipples 6" length, threaded ends. 2 sachi bronze nipples 6" length, threaded ends. 2 each 1-1/2"-90' brass or 2"-90' brass or bronze elbows (FIPT x FIPT). bronze elbows (FIPT x FIPT). 6. 2" (MIPT) x compression fitting, Ford C84-66 or equal. 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to 7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length fit. to fit. 8. 2" threaded brass 90' ell. 8. 1-1/2" threaded brass 90' ell, for Ford L44-77 or equal. 9. 2" Customsetter with by-pass Ford: VBH 86-12B-11-77 (x 17-3/16" 9. 1-1/2" Customsetter with by-pass Ford: VBH 86-12B-11-66 (x ), McDonald Bross: 308715WDFF775 or Mueller B-1427-2", with flanged 13-3/16"), McDonald Bross: 308612WDFF665 or Mueller B-1427-1 1/2", angle ball valve and padlock wings on inlet, and angle check valve with flanged angle ball valve and padlock wings on inlet, and angle check outlet, ball valve on bypass with padlock wings. Customsetter shall valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet cod outlet. have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by!(?. Rigid meter spreader to be supplied and installed in meter setter by contractor. contractor. 119. Water meter shall be supplied and installed by City of Renton upon T11,. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and payment of all related water meter fee and satisfactory pressure and purity tests. purity tests. I12. 17%30" Plastic meter box equal to Mid -States Plastics, Inc. 8CF Series 12. 17"x30' Plastic meter box equal to Mid -States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" MSBCF 1730-18 with 2" thick Ductile iron diamond plate co er 18"x31" equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2" drilled hole equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2"drilled hole for for touchread pit lid, and meter read lid. touchread pit lid. 13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford or equal. The property owner is responsible for any necessary adaptation or C-14-66 or equal. The property owner is responsible for cry necessary extension of water service. adaptation or extension of water service. NOTE: ALL METER BOXES INSTALLED IN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER.. BOX. STD. PLAN - 320.2 PUBLIC WORKS 1 12" AND 2" WATER SERVICE LOCATED * ''•` .` DEPARTMENT IN PLANTING STRIP ��N Sow MARCH 2O10 design PLLC A CIVIL ENGINEERING COMPANY 219 First Avenue S., Suite 401 Seattle WA 98104 206 402 4644 FINISHED GRADE ELEVATION 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) \ NEW WATER MAIN POLYPIG rj 1> VERTICAL CROSS FOR POLYPIGGING STATION TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE INSTALL 2" PLUG ON TOP BLIND FLANGN AFTER REMOVAL OF POLYPIG SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG") ONE BLIND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN ° n l PUBLIC WORK; POLY PIG STATION FOR CLEANING OF STD. PLAN - 300.6 '`•` ` DEPARTMENT WATER MAINS r�N'CO, MARCH 2O10 A q PLAN VIEW WATER VALVE BOX LID WITH EARS IN DIRECTION OF 2" SQUARE WATER MAIN AND WORD "WATER" i OPERATING NUT 12" MIN. CAST INTO IT - L0." MAX 4" CONCRETE COLLAR FOR VALVES IN PAVED AREAS 4-1/4" DIA. 12„ `�- 1/8' MIN. THICKNESS 51 E' I7LtAfL 2 PIECE" 'CAST IRON'VALVE BOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY LENGTH LENGTH AS REQUIRED 1 /8" MIN. THICKNESS 2-1/4" INSIDE MEASUREMENT 2-1/4" DEPTH SECTION A -A VALVE OPERATING NUT EXTENSION VALVE OPERATION NUT EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN THREE (3) FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS 3 �3 T -' 3" 38" MIN. WIDTH WHITE PC _I =1 62„ IIIIIIIIIITI IIII I -III_ ! i l lil =1 I 24" VALVE MARKER POST STD. PLAN - 330.1 O PUBLIC WORKS VALVE BOX, MARKER & OPERATING DEPARTMENT NUT EXTENSION 2 BID ADDENDUM # 1 8 18 2017 SURVEYED_ 3 BID ADDENDUM # 2 08 29 2017 DESIGNED: 5 CONSTRUCTION ASI-1 11 15 2017 TTG DRAWN: TTG CHECKED: WE N0. REVISION BY DATE APPR APPROVED SCALE: 1 " = 10, ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORE/PRESERVATIVE PAINT No. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ TWO-PIECE CAST IRON VALVE BOX WITH LUG 5'x5'x6" THICK CONCRETE PAD AROUND TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. HYDRANT. FINISH TO MATCH SIDEWALK. STANDARD 8" TOP SECTION WITH REGULAR BASE rye EXPANSION JOINT AT SECTION LENGTH TO FIT. VALVE NUT EXTENSION Oo BACK OF SIDEWALK AS REQUIRED. 2„� �CONCRETE SIDEWALK RAISED PAVEMENT MARKER TYPE 88-A OR PLANTING STRIP STIMSONITE TWO-WAY BLUE REFLECTIVE 36" MIN COVER K-y -CONCRETE BLOCKING CONCRETE -� THRUST BLOCK MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR-TEN STEEL TIE RODS. 16" x 8" x 4" MININUM 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK CONCRETE BEARING 1' ABOVE BOOT FLANGE. PLACE 8 MIL BLOCK UNDER HYDRANT POLYETHYLENE. .FILM ARCLIND TOP AND. .SIDES OF GRAVEL. FIRS HYDRANT ASSEMBLY LEVEL ALL GROUND LEVEL ALL GRDUN➢ MIN 3' RADIUS MIN 3' RADIUS 1 6 ONE MAN ROCK �1 1 1 - 6 ., 6" CONCRETE PAD 6 CONCRETE PAD,, CU T FILL HYDRANT LOCATION IN CUT OR FILL TY �► °� PUBLIC WORKS FIRE HYDRANT ASSEMBLY STD. PLAN - 310.1 DEPARTMENT �F.N,Vp MARCH .2010 4� 4:_ 11-1/4` BEND 22-1/2` BEND 45' BEND CAP GEE 90, BEND 'THIROSY BLOCK BEAOIOG AREA II S00ABE"FEET (SEE NOTES) 1Ftlt�''NttRlZDia^FA'L "1k`NEi lFibitfd^IYDI�U VFfiTiCA't- BL'iV115'„ SOIL FIRM SILT OR SISAND FIRM LTY COMPACT SAND COMPACT SAND & GRAVEL 90, 45' BEND 11 1/4' 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2" BEND TEE CAP OR PLUG & 22 1/2' BEND BEND BEND 4" 7.0 4.2 1 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 1.6 1.0 C 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 1 16.7 6.7 11.7 8.4 8.4 3.4 8.8 6.3 6.3 2.5 12" 53.0 37.51 37.5 15.0 26.5 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE, 3'-0" MIN, COVER FOR WATERMAIN LESS THAN 12", 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) - 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' THRUST BLOCK BEARING AREA REFERS TO THE FACE OF BLOCK MEASURED IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND. FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER., 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/2"), 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. CONCRETE BLOCKING FOR STD. PLAN - 330.2 • PUBLIC WORKS + + HORIZONTAL AND DOWNWARD DEPARTMENT VERTICAL BENDS MARCH 2O10 CALL 48 HOURS BEFORE YOU DIG! 811 Aowu %R1 CITY OF 17 RENTON Planning/Building/Public Works Dept. W - 395504 T J W 17) IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 RENTON COMMONS LLC 215 WHITWORTH AVE S, RENTON, WA 98057 COR STD DETAILS m Cn Z O 75 2 O DATE: U 11/15/2017 Z FIELDBOOK: O PAGE: I ­_ DRAWING NO: C7.4 ,z SHEET: 1 3 OF: 15 Ir