HomeMy WebLinkAboutMFP23002759 - Site Plan 17906 119th Ave SE.pdf4��- VDV-,�� v\,
t(i�ok� S�v .
S-1 k<�O)t�- <�E
FUTURE WHEN r IMPROVEMENT IN
REQUESTED PUBLIC RIGHT—OF—WAY
BY OWNER
L7�W
_ PUBLIC R/W
R/
SEE NOTE 3
1 1/4' FUSED HOPE
END CAP
3' MIN.
COVER X
CAST IRON VALVE BOX
WITH LID MARKED
"SEWER" SERIES 9406
OR AS APPROVED BY/
DISTRICT
WATER MAIN n:�
BY OTHERS 7 4 >
rl
4" FROM
HOUSE
GRINDER PUMP L1-1/4"
SDR.
PER SODS CREEK W & S
11 HOPE
DISTRICT SPECIFICATIONS
FORCE MAIN
WITH BUILT-IN CHECK
SERVICE LINE
AND SHUT-OFF VALVES
SCH. 40 G.S.P. 20'-0"
LENGTH CENTERED
UNDER WATER LINE END
REAM OR PROVIDE
PROTECTIVE SLEEVE WITH
FOAM FILLED ENDS
1-1/4" SDR, 11 HOPE
- CFORCE MAIN
11 SERVICE LINE
2" RESILIENT WEDGE GATE VALVE,
CLOW MODEL F-6102 FLANGED,
W/ SUPPORT BLOCKING, 2%
1-1/4" BRASS OR STAINLESS
STEEL REDUCER EACH SIDE
R/W �{
0
LOW PRESSURE HOPE
SEWER MAIN
HOPE TEE (MAIN LINE
SIZE x 1 1/4")
FUSED CONNECTION
TO 1 1/4" TEE
2" BRASS SWING CHECK VALVE, W/
Z. , _ 2"xl-1/4" BRASS OR STAINLESS
STEEL REDUCER EACH SIDE. CONNECT
1 WITH 2 EA. 1--1/4" HOPE x MIP
FLOW 304SS TRANSITION FITTINGS
GRINDER PUMP SERVICE LINE NOTES
1. INSTALL 16-GAUGE SOLID COPPER TRACER WIRE ALONG TOP OF HOPE FORCE MAIN SERVICE LINE WITH WARNING TAPE MARKED
"SEWER" 12" ABOVE SERVICE LINE, TRACER WIRE SHALL EXTEND FROM LOW PRESSURE SEWER MAIN TO VALVE AT
RIGHT-OF-WAY LINE AND FROM GATE VALVE TO GRINDER PUMP. TRACER WIRE SHALL TERMINATE IN VALVE CAN WITH EXTRA
24" OF COIL AND TERMINATE AT GRINDER PUMP LID,
2. THE LOCATION OF THE STUB SERVICE TERMINATION SHALL BE MARKED BY THE CONTRACTOR WITH 2"x4" TIMBER EXTENDED
VERTICALLY FROM THE PLUG END TO A MINIMUM OF 12" ABOVE THE GROUND SURFACE. A 12-GAUGE GALVANIZED WIRE SHALL
BE ATTACHED TO THE TIMBER FROM END TO END. NEITHER THE WIRE NOR THE 2"x4" SHALL BE SECURED OR ATTACHED TO THE
SEWER PIPE DR PLUG. THE EXPOSED PORTION OF THE 2"x4" SHALL BE PRE -PAINTED TRAFFIC WHITE WITH THE WORDS "GRINDER
PUMP SEWER CONNECTION" STENCILED ON WITH BLACK PAINT, THE END OF THE 2%4" SHALL BE PRE -MARKED IN PERMANENT
INK WITH THE LENGTH OF THE TIMBER INSTALLED.
3. INSTALL A 2 FOOT SQUARE x 4" THICK ASPHALT OR CONCRETE PAD AROUND THE VALVE BOX AT ALL VACANT LOTS.
GRINDER PUMP SERVICE LINE FOR SMALL DIA.
LOW PRESSURE SEWER IN PUBLIC R.O.W.
REVISION DATE I SCALE DISTRICT APPROVAL DATE APPROVED
MAY 17. 2011 NTS K.V. JUNE 02, 2011
FILE NAME
M:\S00S CREEK W&S\DESIGN STANDARDS\SWR DTLS\S-17 DWG. NO. 7S-17