Loading...
HomeMy WebLinkAboutMarriot Residence Inn Plans 09CITY OF RENTON STORMWATER DRAINAGE NOTES 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE "1988 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION" PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATIONS (APWA), AS AMENDED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. 3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM WATER UTR.ITY. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM SHALL BE U.S.G.S UNLESS OTHERWISE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTUTY. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTILITY. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARE FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C," WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95 PERCENT FOR PAVEMENT AND STRUCTURAL FILL AND 90 PERCENT OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES AND OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT # 1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS AND EXISTING PUBLIC RIGHT-OF-WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF 1 FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 INCHES TO 8 INCHES/40 PERCENT TO 70 PERCENT PASSING; 2 INCHES TO 4 INCHES ROCK/30 PERCENT TO 40 PERCENT PASSING; AND -2 INCHES ROCK/10 PERCENT TO 20 PERCENT PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM UNLESS APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORMWATER UTILITY. AN ACCURATELY DIMENSIONED CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF RENTON UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFT, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REOUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DIVISION OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07.23, TRAFFIC CONTROL, SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA. 0 0 0 ul CV O N 0 Lk 0.250 3.000 NOTES: 1. ALL STROKES TO BE 3" WIDE. 2. PROVIDE TWO COATS OF PAINT. 3. BLUE BACKGROUND WITH WHITE SYMBOL. 4. LOCATE SYMBOL AT CENTER OF STALL WHERE SHOWN ON SITE PLAN. 5. ONE SYMBOL FOR EACH HANDICAP PARKING SPACE. 0.250 HANDICAP SYMBOL NOT TO SCALE ACCESSIBLE PARKING SIGN LOCATE FACE OF CONCRETE BLOCK FLUSH WITH EDGE OF CONCRETE WALK. 4" WIDE F YELLOW S TWO COA" PLAN HANDICAP PARKING NOT TO SCALE 12" PARKING VAN ACCESSIBLE �" 0 b LO a e a b d 2.0% MAX :� 4 SLOPE ENVELOPE AROUND 12" HANDICAP STALLS (TYP.) CONSTRUCTION NOTES AND DETAILS STC iM DRAINAGE PIPE SPECIFICATKAS ALL STORM DRAIN PIPE MAY BE CONSTRUCTED OF ONE OF THE FOLLOWING MATERIALS UNLESS OTHERWISE SPECIFIED IN THE PLANS. ALL PIPE JOINTS MUST BE GASKETED WATERTIGHT AND MUST BE OF THE SAME MATERIAL AS THE PIPE. ALL PIPE SHALL HAVE A MINIMUM COVER AS SPECIFIED AND SHALL BE ADEQUATELY PROTECTED DURING CONSTRUCTION (REFER TO THE MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM COVER FOR HEAVY EQUIPMENT LOADINGS). A. DUCTILE IRON - 4 INCH THROUGH 14 INCH DIAMETER PIPE SHALL BE CLASS 52 AND 16-INCH THROUGH 24-INCH DIAMETER PIPE SHALL BE CLASS 50, ALL IN ACCORDANCE WITH USA STANDARD A-21.1 (AWWA C-51). ALL JOINTS SHALL BE PUSH -ON, MECHANICAL, OR FLANGED (6-INCH MINIMUM COVER). B. CONCRETE - 4 INCH THROUGH 18 INCH DIAMETER PIPE SHALL BE NON -REINFORCED, BELL AND SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C-4 (CLASS 11). 21 INCH THROUGH 36 INCH DIAMETER PIPE SHALL BE REINFORCED, BELL AND SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C- 76 (2 FOOT MINIMUM COVER). C. PVC - 4 INCH THROUGH 18 INCH DIAMETER PIPE, WITH 24-INCH TO 36-INCH OF COVER SHALL BE IN ACCORDANCE WITH ASTM D3034 SDR 21. 4-INCH THROUGH 18-INCH DIAMETER PIPE, WITH ASTM D3034 SDR 35 SHALL HAVE 36-INCH MINIMUM COVER. ALL JOINTS SHALL BE PUSH -ON WITH RUBBER GASKETS. PVC STORM PIPE REQUIRES A.C. COLDS (I.E., CATCH BASIN CONNECTION) OR KOR-N-SEAL CONCRETE BOOTS. D. HELICAL CORRUGATED PLAIN ALUMINUM PIPE (CMP) - 6 INCH THROUGH 18 INCH DIAMETER PIPE SHALL BE 16 GAUGE WITH 2 2/3 INCH X 1 /2 INCH CORRUGATIONS. 21 INCH THROUGH 36 INCH DIAMETER PIPE SHALL BE 14 GAUGE WITH 2 1 /3 INCH X 1 /2 INCH CORRUGATIONS. REFER TO DETAILS IN THESE PLANS FOR ANY PIPES LARGER THAN 36 INCH DIAMETER. ALL ALUMINIZED PIPE SHALL HAVE ASPHALT TREATMENT 1 COATING (2.0-FOOT MINIMUM COVER). E. HELICAL CORRUGATED STEEL PIPE (HCMP) - 6 INCH THROUGH 36 INCH SHALL BE 16 GAUGE WITH 2 2/3 INCH X 1 /2 INCH CORRUGATIONS. ALL STEEL MATERIALS SHALL BE GALVANIZED AND ASPHALT TREATMENT 1 COATED. REFER TO DETAILS IN THESE PLANS FOR ANY PIPES LARGER THAN 36 INCHES IN DIAMETER (2.0-FOOT MINIMUM COVER). F. CORRUGATED POLYETHELENE MEETING THE REQUIREMENTS OF AASHTO M-294, TYPE S. MINIMUM PIPE DIAMETER SHALL BE 8". MAXIMUM PIPE DIAMETER SHALL BE 36" OR THE DIAMETER FOR WHICH THE SUPPLIER HAS A JOINT CONFORMING TO ASTM D 3212, WHICHEVER IS LESS. JOINTS SHALL BE CLASSIFIED AS "WATERTIGHT". WATERTIGHT JOINTS SHALL BE MADE WITH A SLEEVE OR WITH A BELL SPIGOT AND SHALL CONFORM TO ASTM D 3212 (10.8 PSI) USING ELASTOMERIC GASKETS CONFORMING TO ASTM F 477. GASKETED JOINTS SHALL BE LUBRICATED AS RECOMMENDED BY THE PRODUCER DURING INSTALLATION. "SOILTIGHT" JOINTS SHALL NOT BE PERMITTED. FITTINGS SHALL BE BLOW MOLDED, ROTATIONAL MOLDED, OR FACTORY WELDED. THERMOPLASTIC PIPE FITTINGS SHALL MEET THE REQUIREMENTS SET FORTH IN AASHTO M 294. 0 z C� tt� uD 0") x cv 00 r � i CN STEEL POST CONCRETE FOUNDATION DISABLED PARKING SIGN INSTALLATION NOT TO SCALE 1 /4" x 2" DUMMY JOINT (TYP) qQ 6 ° q ° q q ° q PCURB TAPER Q a ° a � CURB TAPER �D V 0.5 VARIES 5'-$" VARIES RIGHT-OF-WAY LINE 1 1 CEMENT CONCRETE DRIVEWAY 5" THICK SECTION A -A MATCH EXISTING DRIVEWAY GRADE CURB AND GUTTER SECTION DRIVEWAY NOT TO SCALE BY BY CONC. FOOTING (TYP.) BRACE POSTS LINE POST TWISTED AND BARBED SELVAGE NOT TO SCALE 6" PORTLAND CEMENT CONCRETE 0 00 f _ _ C= _ PULL POST BRACE POST TOP RAIL GREEN VINYL COATED, 9 GA. CHAIN LINK FABRIC STRETCHER BAR SLOPE TOP OF FOOTING TO DRAIN (TYP.) TENSION WIRE 6 6" DEEP WASHED NOTE: ° ROCK BASE (TYP.} LIN ALL FENCING MATERIALS MUST BE VINYL COATED. o TUCDC CUAI I DC AI(1 CVOnCl-n IICTAI CI IDCAI`CC 4" COMPACTED DEPTH CRUSHED ROCK 12" MIN. SUBGRADE COMPACTED TO 95% NOTE: GEOTECHNICAL ENGINEER SHALL BE ONSITE DURING PLACEMENT OF FILL TO VERIFY THAT COMPACTION MEETS MINIMUM REQUIREMENTS FOR PAVEMENT SECTION. TYPICAL CONCRETE PAVING SECTION NOT TO SCALE SEAL JOINT SAWCUT PAV'T 12 OUTSIDE OF TRENCH EDGES SIDEWALK DUMMY JOINT PLANTING STRIP, IFANY FINISH GRADE PATCH SURFACING TO MEET AND MATCH EXISTING. MINIMUM SECTION TO BE 3" A.C. PAV'T CL. B OVER 4" CRUSHED ROCK BASE i //. STRUCTURAL FILL MATERIAL COMPACTED TO 95% OF MAX. DENSITY SUBGRADE OR STRUCTURAL FILL MATERIAL COMPACTED TO 90% OF MAX. DENSITY GRAVEL BACKFILL FOR PIPE BEDDING COMPACTED TO 95% OF MAX. DENSITY NOTES: 1. PROVIDE 4" SAND BLANKET BEDDING FOR RIGID PIPE 2. ALL TESTING OF BACKFILL AND COMPACTION SHALL BE W CONFORMANCE WITH ASTM D-1557 PIPE BEDDING DETAIL NOT TO SCALE CHEMM FOR COMPLJANM TO Cmr STANDAFM Date Date Date PLC SAD w aj WAs111 a,.. Ow 24661� `ass n / S T �R' IONA L nsahnLr EXTRUDED CONCRETE CURB DETAIL NOT TO SCALE PAVEMENT WIDTH 12" 6" 1" R 1" R 44 .� 5% o A C'1l 18» CEMENT CONCRETE VERTICAL CURB AND CUTTER CURB AND GUTTER NOT TO SCALE 2" COMPACTED DEPTH - CLASS 'B' A.C. PAVEMENT 4" COMPACTED DEPTH CRUSHED ROCK BASE COURSE uuuu u� a uu LUG 0 cam° a 000 o0 vo'� °0000 0 08O o000onrP non a o �o C=D 1 12" MIN. SUBGRADE COMPACTED -' TO 95% DRY DENSITY TYPICAL ONSITE ASPHALT PAVING SECTION NOT TO SCALE n W U) a. c� N 4 C) N rr E a c) 3 I _0 It tp In i cr a) c c a> tU LC} LO In 0 Q C:} LO a: LZ q (10 to to lr�