Loading...
HomeMy WebLinkAboutStreetlight Pre-Con Meeting MEMOFOR MARRIOTT RESIDENCE INN U15008434 12.07.2017CITY OF RENTON STREETLIGHT PRECONSTRUCTION MEETING [Marriott Residence Inn], 12/07/2017 PROJECT PERSONNEL: Rohini Nair, City Project Manager 425-430-7298 rnair@rentonwa.gov Brad Stocco, Public Works Inspector 425-207-6013 bstoco@rentonwa.gov Eric Cutshall, Transportation Maintenance Manger 425-430-7223 ecutshall@rentonwa.gov Jack Oxford, Electrical Inspector 206-999-1822 joxford@rentonwa.gov ELECTRICAL: After calling in the inspection request through the Inspection Request Line, contact Ryan Puddy (206-999-1821) or Jack Oxford (206-999-1822) at 7:30 a.m. the morning of the inspection to provide a contact name and phone number for arranging the electrical inspection with your representative. Have in your possession the electrical permit and streetlight luminaire checklist. Insert both in a clear plastic document protector and attach it to a conduit stubbed up. If the signal control box is installed, for underground conduit inspection approval, place the documents in the signal control box. Service inspection for signal or lighting control pedestals requires access for electrical inspection. If approved, a service approval sticker will be attached by the meter opening for the serving utility. The serving utility will not and shall not connect power unless the approval sticker is in place. All grounding is to meet Standard Plan -119, dated March 20, 2012. Provide Megger Test Report of all wiring to identify any undergrounded conductor that is grounded or open not completing circuit. When calling in a request for final electrical inspection, provide access to all handholes and access openings to light poles. Some bolts require special sockets or wrenches, which are not available to or provided by the Electrical Inspector. Electrical cabinets (Millbank service cabinets) do not meet the minimum City code standards, therefore shall not be considered allowable. Required Inspections: REQUIRED INSPECTIONS (street lighting checklist provided by city) ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDTION. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ ROUGH-IN INSPECTION. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANANGER FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHOULD SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREETLIGHTING. ELECTRICAL CONTACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED.