HomeMy WebLinkAbout81155060 South Wall Regraded - Calc PackagePROJECT: Renton MRI PROJECT NO.: 81155060 TASK: 5
SUBJECT: South Wall Redesign BY: Zachary L. Koehn DATE:8/29/17
REVIEWED BY: Richard D. Luark DATE: 8/30/17
ATTACHED ARE THE SOIL NAIL CALCULATIONS FOR THE REDESIGN OF THE SOUTH
WALL AS PER THE UPDATED GRADING PLANS FOR THE MARRIOT RESIDENCE INN
LOCATED IN RENTON, WASHINGTON.
THE FOLLOWING CALCULATIONS ARE ATTACHED:
•SOIL NAILS
•SHOTCRETE FACING
PROJECT: Renton MRI PROJECT NO.: 81155060 TASK: 5
SUBJECT: South Wall Redesign BY: Zachary L. Koehn DATE: 8/29/17
REVIEWED BY: Richard D. Luark DATE: 8/30/17
Page 1 of 3
PURPOSE:
Re-design south permanent soil nail wall as per revised grading plan.
GIVEN:
Soil Parameters:
Soil Unit Moist Unit
Weight (pcf)
Friction
(deg)
Cohesion
(psf)
Ultimate Pull Out
Resistance (k/ft)
Med. Dense Granular 125 34 0 4
V. Dense ML/SM 125 32 550 4
V. Dense Sand 120 38 0 4
Reference: “Updated Geotechnical Engineering Study Marriott Residence Inn Proposed Hotel
Facility Renton, Washington” dated April 21, 2015, by Earth Solutions NW LLC.
Reference: “Shoring and Permanent Soil Nail Retaining Wall. Design Drawings and
Specifications, Permit Submittal” dated November 25, 2015, by Terracon, Inc.
Geometry:Original backgrounds supplied by the Jenson Fey Architects based on the 50% DD
set. The structural foundation plans were from DCI Engineers, progress set dated 11/2/15.
Updated backgrounds supplied by Barghausen Consulting Engineers, Inc. revised per City of
Renton comments and 1:1 cut slope dated 7/27/17.
Shoring designed for excavation depth down to the base of the footing although the shotcrete
facing will only extend down to the top of the footing along the perimeter of the building. Were
the free standing permanent soil nail wall is present, the temporary shotcrete facing will extend
down to the base of the footing which is 2-feet below finished grade in front of the wall.
Horizontal soil nail spacing is 6 feet on center. Maximum vertical spacing is 6-feet on center.
Materials:75 ksi threaded tendons in standard bar sizes (#7, #8 & #9). Epoxy coated tendons
for the permanent soil nail wall to provide double corrosion protection. Use 3,000 psi UCS grout
for nails + 4,000 psi UCS for shotcrete.
Factor of Safety on Soils: Minimum factors of safety of 1.5 for static, 1.1 for seismic,1.2 for
interim temporary stability, and soil nail pull out for static of 2.0 and 1.5 for seismic.
Seismic Design: Peak ground acceleration is 0.597g based on USGS website for the IBC
design earthquake adjust for site class C soil profile. Permanent south wall designed with a
pseudo static coefficient equal to ½ of the PGA which equals 0.3.
ASSUMPTIONS:
No construction surcharges on the slope during soil nail construction. Fill placement will be
completed prior to installation of soil nails. Construction surcharges of up to 500 psf vertical are
allowed above the south permanent soil nail wall as the permanent walls are designed for
seismic, which controls the design and can withstand up to a 500 psf construction surcharge for
the temporary condition. Seismic can be ignored as temporary condition.
Material factors: 0.66 on head strength; 0.55 on tendons for both temporary and permanent soil
nail walls.
PROJECT: Renton MRI PROJECT NO.: 81155060 TASK: 5
SUBJECT: South Wall Redesign BY: Zachary L. Koehn DATE: 8/29/17
REVIEWED BY: Richard D. Luark DATE: 8/30/17
Page 2 of 3
Where structural fill is used to backfill, the fill will have material properties equal to that of medium
dense granular soils (friction angle = 34 degrees, cohesion = 0, and unit weight = 125 pcf).
Maximum deflection at top of soil nail wall is on the order of 1-inch or less for temporary and static
conditions. Maximum permanent displacement of the permanent soil nail wall in response to the
design seismic event is 1-inch or less.
ANALYSIS:
Use Snail version 2.0.3.1 to size soil nails using factored resistance (head strength, tendon and
pullout).
RESULTS:
The following summarizes the results for the soil nail analysis. H includes the footing excavation
depth (which is to the based on the perimeter footing excavation; however where the soil nail wall
is adjacent to footing excavations, the facing will only extend down to the top of the footings). T
The Snail outputs are attached. Maximum vertical spacing of soil nails is 6 foot on center.
Schedule #2 – Excavation Height = 30.5 ft
Row L (ft)Bar Vert. Spacing (ft)Horizontal Spacing Angle
1 32 #9 3 6 ft o.c.15
2 30 #9 6 6 ft o.c.15
3 30 #9 6 6 ft o.c.15
4 24 #9 6 6 ft o.c.15
5 18 #8 6 6 ft o.c.15
FSstatic = 1.84, FSseismic = 1.10, FStemp = 1.60
Schedule #3 – Excavation Height = 24.0 ft
Row L (ft)Bar Vert. Spacing (ft)Horizontal Spacing Angle
1 26 #8 2 6 ft o.c.15
2 26 #8 5 6 ft o.c.15
3 18 #8 6 6 ft o.c.15
4 12 #8 6 6 ft o.c.15
FSstatic = 1.91, FSseismic = 1.11, FStemp = 1.61
Schedule #3 – Excavation Height = 15.5 ft
Row L (ft)Bar Vert. Spacing (ft)Horizontal Spacing Angle
2 26 #8 3 6 ft o.c.15
3 18 #8 6 6 ft o.c.15
4 12 #8 4 6 ft o.c.15
FSstatic = 1.99, FSseismic = 1.14, FStemp = 1.47
PROJECT: Renton MRI PROJECT NO.: 81155060 TASK: 5
SUBJECT: South Wall Redesign BY: Zachary L. Koehn DATE: 8/29/17
REVIEWED BY: Richard D. Luark DATE: 8/30/17
Page 3 of 3
Facing:
Snail Version 2.0.3.1 - SH4.0 - 4 04:07:40 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Permanent
Minimum Factor of Safety: 1.84
Calculated Service Load at Soil Nail Head (Empirical), To:24.4 kipsAllowable Facing Resistance, F_allowable (Entered):27.9 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -4.snz
Run Date: 08/30/17
Run Time: 04:07:40
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 45.25 feet
Wall Dimensions:
Wall Height: 29.00 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 5
Angle Distance
No. degrees feet
------------------------
1 0 7.00
2 27 5.60
3 12 7.40
4 23 80.00
5 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation1
--------------------------------------------------------------------
2 0.00 62.25 100.00 62.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 5
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 32.00 15 3.00 6.00 1.125 75.0
2 30.00 15 6.00 6.00 1.125 75.0
3 30.00 15 6.00 6.00 1.125 75.0
4 24.00 15 6.00 6.00 1.125 75.0
5 18.00 15 6.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 27.0 27.9 38.1 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 55.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No 2
Advanced Search Options:
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Permanent
Factor of Safety:
Minimum: 1.84
Found at Search Point: 10
Found at Grid Point: 53
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 24.4 kips
Allowable Facing Resistance, F_allowable (Entered): 27.9 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 24.4 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 2.09 20.00 53.19 33.38 -90.00 6.68 1 30.5 Pullout
2 34.2 Pullout
3 41.7 Bar Yield
4 37.7 Pullout
5 38.8 Facing
2 2.01 23.50 49.91 36.49 90.00 6.98 1 27.1 Pullout
2 31.6 Pullout
3 40.1 Pullout
4 36.7 Pullout
5 39.1 Facing
3 1.95 27.00 47.15 39.70 90.00 7.28 1 24.0 Pullout
2 29.3 Pullout
3 38.5 Pullout
4 35.7 Pullout
5 39.4 Facing
4 1.91 30.50 44.81 42.99 -90.00 7.57 1 21.3 Pullout
2 27.2 Pullout
3 37.1 Pullout
4 34.9 Pullout
5 39.7 Facing
5 1.88 34.00 42.80 46.34 90.00 7.87 1 18.9 Pullout
2 25.3 Pullout
3 35.8 Pullout
4 34.2 Pullout
5 39.9 Facing
6 1.87 37.50 41.06 49.73 90.00 8.17 1 16.8 Pullout
2 23.7 Pullout
3 34.6 Pullout
4 33.5 Pullout3
5 40.1 Facing
7 1.85 41.00 39.55 53.17 90.00 8.46 1 14.8 Pullout
2 22.2 Pullout
3 33.5 Pullout
4 32.9 Pullout
5 40.3 Facing
8 1.85 44.50 38.22 56.64 90.00 8.76 1 13.0 Pullout
2 20.8 Pullout
3 32.6 Pullout
4 32.3 Pullout
5 40.5 Facing
9 1.84 48.00 37.05 60.14 -90.00 9.06 1 11.4 Pullout
2 19.5 Pullout
3 31.7 Pullout
4 31.8 Pullout
5 40.5 Pullout
** 10 1.84 51.50 36.01 63.66 -90.00 9.36 1 9.9 Pullout
2 18.4 Pullout
3 30.9 Pullout
4 31.4 Pullout
5 40.3 Pullout
11 1.84 55.00 35.07 67.20 90.00 9.65 1 8.5 Pullout
2 17.3 Pullout
3 30.2 Pullout
4 31.0 Pullout
5 40.2 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 4 04:05:13 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
0.30
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Seismic
Minimum Factor of Safety: 1.10
Calculated Service Load at Soil Nail Head (Empirical), To:32.1 kipsAllowable Facing Resistance, F_allowable (Entered):38.1 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -4.snz
Run Date: 08/30/17
Run Time: 04:05:13
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 45.25 feet
Wall Dimensions:
Wall Height: 29.00 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 5
Angle Distance
No. degrees feet
------------------------
1 0 7.00
2 27 5.60
3 12 7.40
4 23 80.00
5 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation1
--------------------------------------------------------------------
2 0.00 62.25 100.00 62.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 5
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 32.00 15 3.00 6.00 1.125 75.0
2 30.00 15 6.00 6.00 1.125 75.0
3 30.00 15 6.00 6.00 1.125 75.0
4 24.00 15 6.00 6.00 1.125 75.0
5 18.00 15 6.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 27.0 27.9 38.1 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 53.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No 2
Advanced Search Options:
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Seismic
Factor of Safety:
Minimum: 1.10
Found at Search Point: 11
Found at Grid Point: 51
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 32.1 kips
Allowable Facing Resistance, F_allowable (Entered): 38.1 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 32.1 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 1.61 20.00 39.87 26.06 -90.00 16.70 1 30.2 Pullout
2 30.0 Pullout
3 45.0 Pullout
4 44.0 Pullout
5 54.5 Pullout
2 1.44 23.30 36.76 29.08 90.00 17.40 1 21.0 Pullout
2 25.6 Pullout
3 42.0 Pullout
4 42.3 Pullout
5 53.9 Pullout
3 1.31 26.60 34.24 32.18 -90.00 18.11 1 11.9 Pullout
2 21.8 Pullout
3 39.3 Pullout
4 40.8 Pullout
5 53.4 Pullout
4 1.23 29.90 32.17 35.32 90.00 18.81 1 5.3 Pullout
2 18.5 Pullout
3 37.0 Pullout
4 39.4 Pullout
5 53.0 Pullout
5 1.19 33.20 30.44 38.51 90.00 19.51 1 1.4 Pullout
2 15.5 Pullout
3 34.9 Pullout
4 38.2 Pullout
5 52.6 Pullout
6 1.17 36.50 28.97 41.72 90.00 20.21 1 0.0 Pullout
2 12.8 Pullout
3 33.0 Pullout
4 37.2 Pullout3
5 52.3 Pullout
7 1.15 39.80 32.23 47.05 -90.00 16.73 1 5.4 Pullout
2 18.6 Pullout
3 37.0 Pullout
4 39.5 Pullout
5 53.0 Pullout
8 1.13 43.10 31.03 50.30 90.00 17.29 1 2.8 Pullout
2 16.5 Pullout
3 35.6 Pullout
4 38.6 Pullout
5 52.8 Pullout
9 1.11 46.40 29.98 53.57 90.00 17.85 1 0.4 Pullout
2 14.7 Pullout
3 34.3 Pullout
4 37.9 Pullout
5 52.5 Pullout
10 1.11 49.70 29.05 56.85 90.00 18.41 1 0.0 Pullout
2 13.0 Pullout
3 33.1 Pullout
4 37.2 Pullout
5 52.3 Pullout
** 11 1.10 53.00 32.06 62.54 -90.00 14.22 1 5.1 Pullout
2 18.3 Pullout
3 36.8 Pullout
4 39.3 Pullout
5 53.0 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 4 04:58:00 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
500 psf
500 psf
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.60
Calculated Service Load at Soil Nail Head (Empirical), To:27.5 kipsAllowable Facing Resistance, F_allowable (Entered):29.2 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 4 04:09:50 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
Ø=1.125 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.66
Calculated Service Load at Soil Nail Head (Empirical), To:26.5 kipsAllowable Facing Resistance, F_allowable (Entered):27.0 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 4 - Interim 04:09:11 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Ø=1.125 inches fy=75.0 ksi γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Permanent
Minimum Factor of Safety: 2.93
Calculated Service Load at Soil Nail Head (Empirical), To:1.7 kipsAllowable Facing Resistance, F_allowable (Entered):30.8 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Facing Analysis
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
Draft Standard Drawing xs12-000-1 February 2013: Design Number 1
======================================================================================================
Analysis
======================================================================================================
Method: ASD
Temporary Shoring Only: No
Check Bearing Plate Capacity: No
======================================================================================================
Soil Nails
======================================================================================================
Horizontal Spacing: 5.00 feet
Vertical Spacing: 5.00 feet
======================================================================================================
Facing
======================================================================================================
Temporary Permanent
-------------------
Facing Thickness: 4.000 8.000 inches
Vertical Reinforcement Area: 0.08 0.20 in²/foot
Horizontal Reinforcement Area: 0.08 0.20 in²/foot
No. of Vertical Waler Bars: 2 0
No. of Horizontal Waler Bars: 2 0
Waler Bar Area: 0.20 0.00 in²
Waler Bar Yield Strength: 60.0 60.0 ksi
Concrete Yield Strength: 3.6 3.6 ksi
Reinforcement Yield Strength: 65.0 60.0 ksi
Punching Correction Factor: 1.00 1.00
Flexural Correction Factor: 2.00 1.00
======================================================================================================
Bearing Plates
======================================================================================================
Bearing Plate Width / Height: 8.000 inches
Bearing Plate Thickness: 0.750 inches
======================================================================================================
Studs
======================================================================================================
Number of Studs: 4
Stud Head Diameter: 1.250 inches
Head Thickness: 0.310 inches
Headed-Stud Length: 5.250 inches
Stud Shaft Diameter: 0.750 inches
Stud Spacing: 4.000 inches
Stud Tensile Strength: 60.0 ksi
======================================================================================================
Factors of Safety
======================================================================================================
ASD Facing Factors of Safety:
Temporary Permanent Seismic
-----------------------------
Punching: 1.35 1.50 1.10
Flexural: 1.35 1.50 1.10
Stud Tensile: 2.00 1.50
======================================================================================================
Results 1
======================================================================================================
Facing:
Capacity Ratio
Allowable (Normalized by
Resistance Control Mode
Analysis Failure Mode kips Capacity)
------------------------------------------------------
Temporary: Flexure: 28.3 1.05
Punching Shear: 27.0 1.00
Permanent: Flexure: 40.9 1.47
Punching Shear: 27.9 1.00
Stud Tensile: 53.0 1.90
Seismic: Flexure: 55.8 1.47
Punching Shear: 38.1 1.00
Stud Tensile: 70.7 1.86
======================================================================================================
END OF REPORT
======================================================================================================
2
Snail Version 2.0.3.1 - SH4.0 - 5 04:11:55 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Permanent
Minimum Factor of Safety: 1.91
Calculated Service Load at Soil Nail Head (Empirical), To:11.6 kipsAllowable Facing Resistance, F_allowable (Entered):27.9 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -5.snz
Run Date: 08/30/17
Run Time: 04:11:55
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 42.25 feet
Wall Dimensions:
Wall Height: 21.50 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 4
Angle Distance
No. degrees feet
------------------------
1 0 7.20
2 27 22.70
3 23 38.00
4 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation
--------------------------------------------------------------------1
2 0.00 60.25 100.00 60.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 4
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 26.00 15 3.00 6.00 1.000 75.0
2 26.00 15 6.00 6.00 1.000 75.0
3 18.00 15 6.00 6.00 1.000 75.0
4 12.00 15 4.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 27.0 27.9 38.1 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 80.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No
Advanced Search Options:2
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Permanent
Factor of Safety:
Minimum: 1.91
Found at Search Point: 10
Found at Grid Point: 10
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 11.6 kips
Allowable Facing Resistance, F_allowable (Entered): 27.9 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 11.6 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 2.18 20.00 44.44 28.01 -90.00 8.41 1 27.0 Pullout
2 39.6 Pullout
3 32.0 Pullout
4 25.2 Pullout
2 2.04 26.00 39.92 33.90 90.00 9.32 1 22.0 Pullout
2 36.2 Pullout
3 30.2 Pullout
4 24.5 Pullout
3 1.98 32.00 36.44 39.77 90.00 10.12 1 17.7 Pullout
2 33.3 Pullout
3 28.7 Pullout
4 23.9 Pullout
4 1.95 38.00 37.38 47.82 -90.00 7.26 1 18.9 Pullout
2 34.1 Pullout
3 29.1 Pullout
4 24.1 Pullout
5 1.93 44.00 23.82 19.24 49.65 40.77 1 8.8 Pullout
2 19.7 Pullout
3 21.6 Pullout
4 21.2 Pullout
6 1.95 50.00 26.41 27.91 49.21 38.27 1 2.4 Pullout
2 23.0 Pullout
3 23.3 Pullout
4 21.8 Pullout
7 1.94 56.00 21.42 24.06 46.29 48.62 1 0.0 Pullout
2 16.2 Pullout
3 19.8 Pullout
4 20.5 Pullout
8 1.95 62.00 20.55 26.49 44.99 52.60 1 0.0 Pullout3
2 14.9 Pullout
3 19.1 Pullout
4 20.2 Pullout
9 1.92 68.00 24.58 22.43 38.10 60.49 1 3.1 Pullout
2 20.7 Pullout
3 22.1 Pullout
4 21.4 Pullout
** 10 1.91 74.00 17.50 15.52 35.35 72.58 1 0.6 Pullout
2 16.7 Pullout
3 16.4 Pullout
4 19.2 Pullout
11 1.95 80.00 16.26 16.67 33.27 76.54 1 0.0 Pullout
2 13.8 Pullout
3 15.1 Pullout
4 18.7 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 5 04:13:14 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
0.30
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Seismic
Minimum Factor of Safety: 1.11
Calculated Service Load at Soil Nail Head (Empirical), To:19.8 kipsAllowable Facing Resistance, F_allowable (Entered):38.1 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -5.snz
Run Date: 08/30/17
Run Time: 04:13:14
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 42.25 feet
Wall Dimensions:
Wall Height: 21.50 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 4
Angle Distance
No. degrees feet
------------------------
1 0 7.20
2 27 22.70
3 23 38.00
4 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation
--------------------------------------------------------------------1
2 0.00 60.25 100.00 60.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 4
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 26.00 15 3.00 6.00 1.000 75.0
2 26.00 15 6.00 6.00 1.000 75.0
3 18.00 15 6.00 6.00 1.000 75.0
4 12.00 15 4.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 27.0 27.9 38.1 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 80.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No
Advanced Search Options:2
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Seismic
Factor of Safety:
Minimum: 1.11
Found at Search Point: 8
Found at Grid Point: 51
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 19.8 kips
Allowable Facing Resistance, F_allowable (Entered): 38.1 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 19.8 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 1.44 20.00 35.01 24.42 -90.00 14.01 1 21.0 Pullout
2 42.7 Pullout
3 37.3 Pullout
4 31.5 Pullout
2 1.21 26.00 30.87 30.29 90.00 15.54 1 13.1 Pullout
2 37.3 Pullout
3 34.6 Pullout
4 30.4 Pullout
3 1.12 32.00 27.80 36.18 90.00 16.87 1 6.5 Pullout
2 32.9 Pullout
3 32.2 Pullout
4 29.6 Pullout
4 1.14 38.00 25.53 42.11 -90.00 18.15 1 1.0 Pullout
2 29.2 Pullout
3 30.3 Pullout
4 28.8 Pullout
5 1.12 44.00 27.91 49.79 -90.00 15.54 1 6.7 Pullout
2 33.0 Pullout
3 32.3 Pullout
4 29.6 Pullout
6 1.12 50.00 26.41 55.83 90.00 16.56 1 3.2 Pullout
2 30.7 Pullout
3 31.1 Pullout
4 29.1 Pullout
7 1.12 56.00 25.21 61.89 90.00 17.57 1 0.2 Pullout
2 28.7 Pullout
3 30.0 Pullout
4 28.7 Pullout
** 8 1.11 62.00 27.69 70.02 90.00 13.94 1 6.2 Pullout3
2 32.7 Pullout
3 32.1 Pullout
4 29.5 Pullout
9 1.12 68.00 25.65 75.44 90.00 14.00 1 1.4 Pullout
2 29.4 Pullout
3 30.4 Pullout
4 28.9 Pullout
10 1.13 74.00 26.76 82.88 -90.00 9.33 1 4.1 Pullout
2 31.2 Pullout
3 31.4 Pullout
4 29.2 Pullout
11 1.13 80.00 16.26 16.67 33.27 76.54 1 0.0 Pullout
2 18.5 Pullout
3 20.2 Pullout
4 24.9 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 5 04:58:57 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
500 psf
500 psf
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.61
Calculated Service Load at Soil Nail Head (Empirical), To:19.2 kipsAllowable Facing Resistance, F_allowable (Entered):27.0 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 5 04:14:39 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.76
Calculated Service Load at Soil Nail Head (Empirical), To:20.2 kipsAllowable Facing Resistance, F_allowable (Entered):27.0 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 5 - Interim 04:16:01 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 2.55
Calculated Service Load at Soil Nail Head (Empirical), To:1.9 kipsAllowable Facing Resistance, F_allowable (Entered):29.2 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Facing Analysis
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
Draft Standard Drawing xs12-000-1 February 2013: Design Number 1
======================================================================================================
Analysis
======================================================================================================
Method: ASD
Temporary Shoring Only: No
Check Bearing Plate Capacity: No
======================================================================================================
Soil Nails
======================================================================================================
Horizontal Spacing: 5.00 feet
Vertical Spacing: 5.00 feet
======================================================================================================
Facing
======================================================================================================
Temporary Permanent
-------------------
Facing Thickness: 4.000 8.000 inches
Vertical Reinforcement Area: 0.08 0.20 in²/foot
Horizontal Reinforcement Area: 0.08 0.20 in²/foot
No. of Vertical Waler Bars: 2 0
No. of Horizontal Waler Bars: 2 0
Waler Bar Area: 0.20 0.00 in²
Waler Bar Yield Strength: 60.0 60.0 ksi
Concrete Yield Strength: 3.6 3.6 ksi
Reinforcement Yield Strength: 65.0 60.0 ksi
Punching Correction Factor: 1.00 1.00
Flexural Correction Factor: 2.00 1.00
======================================================================================================
Bearing Plates
======================================================================================================
Bearing Plate Width / Height: 8.000 inches
Bearing Plate Thickness: 0.750 inches
======================================================================================================
Studs
======================================================================================================
Number of Studs: 4
Stud Head Diameter: 1.250 inches
Head Thickness: 0.310 inches
Headed-Stud Length: 5.250 inches
Stud Shaft Diameter: 0.750 inches
Stud Spacing: 4.000 inches
Stud Tensile Strength: 60.0 ksi
======================================================================================================
Factors of Safety
======================================================================================================
ASD Facing Factors of Safety:
Temporary Permanent Seismic
-----------------------------
Punching: 1.35 1.50 1.10
Flexural: 1.35 1.50 1.10
Stud Tensile: 2.00 1.50
======================================================================================================
Results 1
======================================================================================================
Facing:
Capacity Ratio
Allowable (Normalized by
Resistance Control Mode
Analysis Failure Mode kips Capacity)
------------------------------------------------------
Temporary: Flexure: 28.3 1.05
Punching Shear: 27.0 1.00
Permanent: Flexure: 40.9 1.47
Punching Shear: 27.9 1.00
Stud Tensile: 53.0 1.90
Seismic: Flexure: 55.8 1.47
Punching Shear: 38.1 1.00
Stud Tensile: 70.7 1.86
======================================================================================================
END OF REPORT
======================================================================================================
2
Snail Version 2.0.3.1 - SH4.0 - 6 04:17:36 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
25
30
35
40
45
50
55
60
65
70
75
80
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Permanent
Minimum Factor of Safety: 1.99
Calculated Service Load at Soil Nail Head (Empirical), To:10.8 kipsAllowable Facing Resistance, F_allowable (Entered):30.8 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -6.snz
Run Date: 08/30/17
Run Time: 04:17:36
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 39.50 feet
Wall Dimensions:
Wall Height: 15.50 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 5
Angle Distance
No. degrees feet
------------------------
1 0 8.00
2 32 20.20
3 23 5.20
4 16 14.00
5 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation1
--------------------------------------------------------------------
2 0.00 60.25 80.00 60.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 3
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 22.00 15 3.00 6.00 1.000 75.0
2 18.00 15 6.00 6.00 1.000 75.0
3 12.00 15 4.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 29.2 30.8 42.0 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 50.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No
Advanced Search Options:2
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Permanent
Factor of Safety:
Minimum: 1.99
Found at Search Point: 8
Found at Grid Point: 11
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 10.8 kips
Allowable Facing Resistance, F_allowable (Entered): 30.8 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 10.8 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 2.34 20.00 37.47 15.12 59.90 15.95 1 24.2 Pullout
2 29.1 Pullout
3 24.1 Pullout
2 2.26 23.00 28.40 15.69 62.15 19.69 1 17.9 Pullout
2 24.5 Pullout
3 22.3 Pullout
3 2.17 26.00 27.07 17.52 60.79 21.31 1 14.4 Pullout
2 23.7 Pullout
3 22.0 Pullout
4 2.12 29.00 33.91 34.94 90.00 8.35 1 20.9 Pullout
2 27.5 Pullout
3 23.4 Pullout
5 2.07 32.00 12.69 13.12 53.50 32.28 1 12.1 Pullout
2 11.7 Pullout
3 17.1 Pullout
6 2.05 35.00 18.75 18.48 53.62 29.51 1 6.8 Pullout
2 17.5 Pullout
3 19.6 Pullout
7 2.01 38.00 15.00 11.80 45.95 38.26 1 13.0 Pullout
2 14.9 Pullout
3 18.2 Pullout
** 8 1.99 41.00 14.33 12.69 44.57 40.29 1 10.8 Pullout
2 13.2 Pullout
3 17.9 Pullout
9 2.00 44.00 20.04 18.73 44.20 36.83 1 6.7 Pullout
2 18.7 Pullout
3 20.0 Pullout
3
10 1.99 47.00 18.85 19.87 42.32 38.14 1 4.1 Pullout
2 17.6 Pullout
3 19.6 Pullout
11 1.99 50.00 12.08 15.34 39.53 45.38 1 3.7 Pullout
2 10.2 Pullout
3 16.8 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 6 04:19:13 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
0.30
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
25
30
35
40
45
50
55
60
65
70
75
80
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Seismic
Minimum Factor of Safety: 1.14
Calculated Service Load at Soil Nail Head (Empirical), To:17.3 kipsAllowable Facing Resistance, F_allowable (Entered):42.0 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
File Name: SH4.0 -6.snz
Run Date: 08/30/17
Run Time: 04:19:13
======================================================================================================
Project Information
======================================================================================================
Description: Renton MRI
Location: South Wall
EA:
Project ID: 81155060
Wall No.: South Wall
Structure No.:
Station:
Engineer: RDL/ZLK
Designer
Comments:
Redesign of the south wall as per regraded slope. Originally designed Nov. 19, 2015.
======================================================================================================
Geometry
======================================================================================================
Layout:
Reference Point:
At: Toe of Wall
Distance From Origin: 0.00 feet
Elevation Above Origin: 39.50 feet
Wall Dimensions:
Wall Height: 15.50 feet
Facing Angle: 90.00 degrees
Facing Batter: 0.000 :12 H:V
Ground Surface:
Number of lines that define the ground surface above the wall: 5
Angle Distance
No. degrees feet
------------------------
1 0 8.00
2 32 20.20
3 23 5.20
4 16 14.00
5 0
Number of lines that define the ground surface in front of the toe: 1
Angle Distance
No. degrees feet
------------------------
1 0
Soil Layers:
Number of Layers: 2
Layers Below the Top Layer:
Coordinates of the Top of the Layer: feet
Point 1 Point 1 Point 2 Point 2
Layer Distance Elevation Distance Elevation1
--------------------------------------------------------------------
2 0.00 60.25 80.00 60.25
Ground Water:
Include Ground Water: No
======================================================================================================
Soil Nails
======================================================================================================
Dimensions and Properties:
Maximum Vertical Spacing: 6.00 feet
Number of Soil Nail Rows: 3
Soil Nail Design Parameters: Varying
Soil Nail Inclination Vertical Horizontal Nail Bar Nail Bar Yield
Length From Horizontal Spacing Spacing Diameter Ø Strength fy
No. feet degrees feet feet inches ksi
--------------------------------------------------------------------------------------------------
1 22.00 15 3.00 6.00 1.000 75.0
2 18.00 15 6.00 6.00 1.000 75.0
3 12.00 15 4.00 6.00 1.000 75.0
Facing Resistance:
Temporary Permanent Seismic
ASD Allowable Facing Resistance: 29.2 30.8 42.0 kips
======================================================================================================
Soil Properties
======================================================================================================
Unit Weight Friction Angle Cohesion
γ φ' c'
Layer Description pcf degrees psf
-----------------------------------------------------------------------------------
1 V. Dense ML/SM 125 32.0 550
2 V. Dense Sand 120 38.0 0
======================================================================================================
Loads
======================================================================================================
Applied Loads:
Seismic:
Horizontal Seismic Coefficient: 0.30
External Load:
Apply external load: No
Surcharges:
Apply surcharges: No
======================================================================================================
Factors of Safety
======================================================================================================
Temporary Permanent Seismic
Pullout (Distal): 2.00 2.00 1.50
Pullout (Proximal): 2.00 2.00 1.50
Nail Bar Yield: 1.80 1.80 1.35
======================================================================================================
Search Options
======================================================================================================
Search Limits:
Begin: 20.00 feet
End: 50.00 feet
Below Toe Searches (BTS):
Perform below Toe Search: No
Advanced Search Options:2
Use Advanced Search Options: No
======================================================================================================
Results
======================================================================================================
Analysis:
Method: ASD
Scenario: Seismic
Factor of Safety:
Minimum: 1.14
Found at Search Point: 9
Found at Grid Point: 48
Found at Search Level: Toe of the wall
Load at Soil Nail Head:
Calculated Service Load at Soil Nail Head (Empirical), To: 17.3 kips
Allowable Facing Resistance, F_allowable (Entered): 42.0 kips
F_allowable ≥To OK
Nominal Pullout Resistance:
Nominal Pullout Resistance
Layer Description klf
----------------------------------------------
1 V. Dense ML/SM 3.981
2 V. Dense Sand 3.981
Results by Search Level:
** Indicates Minimum Factor of Safety
Search Level: At the toe of the wall Facing Design Force = 17.3 kips (Clouterre)
------------------------------------------------------------------------------------------------------
| | | | Failure Planes | Reinforcement |
| | | |---------------------------------------|-------------------------------|
| | Minimum | Distance | Lower | Upper | | | |
| | Factor | From Toe |---------------------------------------| | | Controlling |
|Search | of | of Wall | Angle | Length | Angle | Length | | Stress | Resistance |
|Point | Safety | feet | degrees | feet | degrees | feet | Level | ksi | Failure Mode |
------------------------------------------------------------------------------------------------------
1 1.54 20.00 26.24 15.61 69.56 17.18 1 23.2 Pullout
2 30.9 Pullout
3 29.1 Pullout
2 1.44 23.00 24.87 17.75 68.38 18.73 1 17.1 Pullout
2 29.7 Pullout
3 28.6 Pullout
3 1.33 26.00 31.52 30.50 -90.00 10.63 1 24.7 Pullout
2 35.0 Pullout
3 30.6 Pullout
4 1.24 29.00 33.91 34.94 90.00 8.35 1 27.8 Pullout
2 36.6 Pullout
3 31.2 Pullout
5 1.17 32.00 32.24 37.83 90.00 8.65 1 25.7 Pullout
2 35.5 Pullout
3 30.8 Pullout
6 1.17 35.00 26.98 39.27 90.00 11.88 1 18.1 Pullout
2 31.6 Pullout
3 29.3 Pullout
7 1.15 38.00 25.75 42.19 90.00 12.22 1 16.1 Pullout
2 30.5 Pullout
3 28.9 Pullout
8 1.14 41.00 24.69 45.13 -90.00 12.57 1 14.2 Pullout
2 29.6 Pullout
3 28.5 Pullout
** 9 1.14 44.00 23.64 48.03 90.00 12.84 1 12.4 Pullout
2 28.6 Pullout
3 28.2 Pullout
3
10 1.15 47.00 22.28 50.79 -90.00 12.84 1 9.8 Pullout
2 27.3 Pullout
3 27.6 Pullout
11 1.17 50.00 21.06 53.58 90.00 12.84 1 7.4 Pullout
2 26.0 Pullout
3 27.2 Pullout
======================================================================================================
END OF REPORT
======================================================================================================
4
Snail Version 2.0.3.1 - SH4.0 - 6 05:00:09 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
500 psf
500 psf
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
25
30
35
40
45
50
55
60
65
70
75
80
85
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.61
Calculated Service Load at Soil Nail Head (Empirical), To:18.3 kipsAllowable Facing Resistance, F_allowable (Entered):27.0 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 6 04:20:17 on 08/30/17
Search Limits
0 5 10 15 20 25 30 35 40 45 50
Ø=1.000 inches fy=75.0 ksi
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
25
30
35
40
45
50
55
60
65
70
75
80
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.73
Calculated Service Load at Soil Nail Head (Empirical), To:18.5 kipsAllowable Facing Resistance, F_allowable (Entered):29.2 kips
F_allowable ≥ To OK
Snail Version 2.0.3.1 - SH4.0 - 6 - Interim 04:22:28 on 08/30/17
Search Limits
0 5 10 15 20 25 30
Ø=1.000 inches fy=75.0 ksi
γ=125 pcf φ'=32.0° c'=550 psf qn=17.60 psi
V. Dense ML/SM
γ=120 pcf φ'=38.0° c'=0 psf qn=17.60 psi
V. Dense Sand
-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
30
35
40
45
50
55
60
65
70
75
80
85
Elevation-feetDistance - feet
Analysis Method:ASD
Analysis Scenario:Temporary
Minimum Factor of Safety: 1.47
Calculated Service Load at Soil Nail Head (Empirical), To:25.2 kipsAllowable Facing Resistance, F_allowable (Entered):29.2 kips
F_allowable ≥ To OK
======================================================================================================
Snail
Version: 2.0.3.1
Facing Analysis
Copyright© 2016 State of California.
All rights reserved.
======================================================================================================
File Information
======================================================================================================
Draft Standard Drawing xs12-000-1 February 2013: Design Number 1
======================================================================================================
Analysis
======================================================================================================
Method: ASD
Temporary Shoring Only: No
Check Bearing Plate Capacity: No
======================================================================================================
Soil Nails
======================================================================================================
Horizontal Spacing: 5.00 feet
Vertical Spacing: 5.00 feet
======================================================================================================
Facing
======================================================================================================
Temporary Permanent
-------------------
Facing Thickness: 4.000 8.000 inches
Vertical Reinforcement Area: 0.08 0.20 in²/foot
Horizontal Reinforcement Area: 0.08 0.20 in²/foot
No. of Vertical Waler Bars: 2 0
No. of Horizontal Waler Bars: 2 0
Waler Bar Area: 0.20 0.00 in²
Waler Bar Yield Strength: 60.0 60.0 ksi
Concrete Yield Strength: 3.6 3.6 ksi
Reinforcement Yield Strength: 65.0 60.0 ksi
Punching Correction Factor: 1.00 1.00
Flexural Correction Factor: 2.00 1.00
======================================================================================================
Bearing Plates
======================================================================================================
Bearing Plate Width / Height: 8.000 inches
Bearing Plate Thickness: 0.750 inches
======================================================================================================
Studs
======================================================================================================
Number of Studs: 4
Stud Head Diameter: 1.250 inches
Head Thickness: 0.310 inches
Headed-Stud Length: 5.250 inches
Stud Shaft Diameter: 0.750 inches
Stud Spacing: 4.000 inches
Stud Tensile Strength: 60.0 ksi
======================================================================================================
Factors of Safety
======================================================================================================
ASD Facing Factors of Safety:
Temporary Permanent Seismic
-----------------------------
Punching: 1.35 1.50 1.10
Flexural: 1.35 1.50 1.10
Stud Tensile: 2.00 1.50
======================================================================================================
Results 1
======================================================================================================
Facing:
Capacity Ratio
Allowable (Normalized by
Resistance Control Mode
Analysis Failure Mode kips Capacity)
------------------------------------------------------
Temporary: Flexure: 28.3 1.05
Punching Shear: 27.0 1.00
Permanent: Flexure: 40.9 1.47
Punching Shear: 27.9 1.00
Stud Tensile: 53.0 1.90
Seismic: Flexure: 55.8 1.47
Punching Shear: 38.1 1.00
Stud Tensile: 70.7 1.86
======================================================================================================
END OF REPORT
======================================================================================================