Loading...
HomeMy WebLinkAbout30% review comments_Seethu BabuComment # Sheet of Page No. Para. Or Detail Or Sta (if applicable) Reviewer initials Comments Designer Response  1 Page 2 Section 3, Para 3, line 6 SB Increase more than 0.15 cfs, not 0.015 cfs   2 Page 2 Section 2, Line 5 SB Reclamation was considered as replaced   3 Page 3 Section 4.2, Para 2.- SB Is existing conveyance system abandoned in place, removed or relocated. Report needs to be consistent with plan set. If abandoned, CCTV needs to be done to make sure no service line connections exist to adjacent properties.   4 Figure 4 Subbasin Delineation Dwg 1-5 SB Label TDA’s   5 Figure 4 Subbasin Delineation Dwg 1-5 SB Add legend with hatching pattern for different catchment areas for SD and Filterra units   6 Page 5 Section 4.5, line 6- SB Reference correct page for table 1.    7 Appendix D  SB Label WWHM2012 to show what it is modeling. For WQ unit, Show 91% flow. Is Filterra sized for offline or online WQ flow? Include output for the WQ flows.   8   SB Show WWHM WQ design flows for catchment areas for Filterra.   9    Show documentation for Filterra unit sizing and capacity. Also show GULD designation for Filterra unit.   10   SB Include pervious sidewalk design. Refer to COR Surface water design manual on credits that can be taken for modeling. Credits can be taken for only if it is unlined and no underdrain.   11 Add new sheet  SB Include a base map drawing showing existing features in ROW to avoid confusion on what is existing and proposed.   12 Sheet 2 Surface water drainage notes and specifications SB Note 2 – accordance with 2016 standard specifications for road, bridge and municipal construction by WSDOT.   13 Sheet 2 Surface water drainage notes and specifications SB Note 17, Line 3- control plan approved by   14 Sheet 10 Plan view STA 96+91.10 SB Clarify whether the CB and SD existing or proposed. COR maps show them as existing.    14 Sheet 10 Plan view STA 96+91.10 SB Clarify whether the CB and SD existing or proposed. COR maps show them as existing.   15 Sheet 10 Plan view STA 97+91.5 SB Is arrow at west end of Duvall pointed to end of fence line per note 15 correct?   16 Sheet 16-21 Plan view SB Label contours   17 Sheet 16 Plan view SB Show pervious sidewalk with legend and matching hatch pattern on west end of Duvall   18 Sheet 16 Plan view SB Label existing ditch on west end of Duvall   19 Sheet 17 Plan view SB Show pervious sidewalk and planter strip with legend and matching hatch pattern on west end of Duvall.   20 Sheet 17 Plan view SB Label existing ditch on west end of Duvall   21 Sheet 17 Plan view SB Label existing gravity culvert under driveway on west end of Duvall   22 Sheet 17 Plan view SB West end of Duvall-by STA 104+50. Refer COR GIS maps on Rainier Ave (SR 167) for preferred angle bend for connection pipe from Filterra unit to CB. COR prefers two 22.5 degree bends for maintenance access. To be reviewed w/maintenance division @60% review process.   23 Sheet 17 Plan view SB East end of Duvall, by STA 105+00, COR GIS maps show a jog from back from flowline to 5’ behind flowline. Show actual location of CB’s. Refer COR dwg. R-295004.    23 Sheet 17 Plan view SB East end of Duvall, by STA 105+00, COR GIS maps show a jog from back from flowline to 5’ behind flowline. Show actual location of CB’s. Refer COR dwg. R-295004.   24 Sheet 18 Plan view SB East end of Duvall, by STA 106+50, COR GIS maps show a jog from back from flowline to 5’ behind flowline. Show actual location of CB’s. Refer COR dwg. R-295004   25 Sheet 18 Plan view SB Show existing ditch on west end of Duvall.   26 Sheet 18 Plan view SB Show existing curb   27 Sheet 19 Plan view SB Confirm SD south of NE 12th St is existing or new. If new system, clarify whether existing system is abandoned in place or removed.   28 Sheet 19 Plan view SB Add new CB at intersection of NE 12th St. and Duvall Ave NE.   29 Sheet 19 Plan view SB Move SD#11 south due to new CB at intersection   30 Sheet 19 Plan view SB Confirm SD north of NE 12th St is existing or new. If new system, clarify whether existing system is abandoned in place or removed. COR maps show existing SD line in the same area.   31 Sheet 19 Plan view SB Include length of culvert. Plans updated with correct length and dimension of culvert. Refer COR GIS maps   32 Sheet 19 Plan view SB Plans updated with correct length and dimension of pipes. Refer COR GIS maps    33 Sheet 19 Plan view SB Plans updated with correct length and dimension of pipes. Refer COR GIS maps   34 Sheet 19 Profile view SB At STA 113+00, check if there is enough vertical clearance between SD and SS.   35 Sheet 20 Plan view SB Confirm SD north of NE 12th St is existing or new. If new system, clarify whether existing system is abandoned in place or removed. COR maps show existing SD line in the same area. Refer COR GIS maps dwg R-197404   36 SD#1-SD#6 Plan view SB Show flow arrows on SD’s for new and existing   37 Sheet 21 Plan view SB Sd#18 will be reviewed @60% design process.