HomeMy WebLinkAboutBoun Short Plat Sheet C5 - Flow Splitter ConceptMBMB0+00 1+00 2+00 3+ 0 0 4+00 4+2420+00435 433 434 436 437 438 CB#1 CB#4 32 LF - 12" CPE-SW @ S=0.50% EX. CB #4 (PER R-332511) 48 LF - 12" CPE-SW @ S=1.72% 39 LF - 12" CPE-SW @ S=0.74%CB#8 CB#9 4 3 4SSCB#10CB#11 39 LF - 12" CPE-SW@ S=0.50%43 LF - 12" PVC SDR-35 @ S=28.40% 410 415 420 425 430 435 440 445 450 410 415 420 425 430 435 440 445 450 0+00 1+00 2+00 3+00 4+00 4+40433.0432.8432.6432.6432.7432.7432.9433.1433.2433.1433.12433.3433.22434.1433.55434.7434.02435.1434.48435.1434.95435.42.33% PVI STA: 3+16.40 PVI ELEV: 433.000 K: 17.03 LENGTH: 50.00 LOW POINT STA: 3+01.70 LOW POINT ELEV: 433.12'BVC STA: 2+91.40BVC ELEV: 433.15EVC STA: 3+41.40EVC ELEV: 433.58GRADE BREAK STA = 4+04.20ELEV = 435.050.6% 2.0% EX. CB #4 (PER R-332511), TYPE 1 STA 1+96.01, 15.15' L RIM 432.20 12" IE 428.35 (IN-E) 12" IE 428.35 (IN-N) 12" IE 428.35 (OUT-S) CB#9, TYPE 1, LOCKING VANED GRATE STA 3+01.70 RIM 432.62 12" IE 429.62 (OUT-S) 39 LF - 12" CPE-SW @ S=0.74% 48 LF - 12" CPE-SW @ S=1.72% CB#1, TYPE 1, LOCKING VANED GRATE STA 2+07.22 RIM 432.32 12" IE 428.51 (IN-E) 12" IE 428.51 (IN-N) 12" IE 428.51 (OUT-W) 32 LF - 12" CPE-SW @ S=0.50%43 LF - 12" PVC SDR-35 @ S=28.40 % CB# 10, TYPE 2-60" (FS) LOCKING VANED GRATE STA 0+47.12, 13.21' L 12" IE 427.57 (IN-N) 12" IE 427.57 (IN-E) 12" IE 427.67 (OUT-W) 12" IE 427.67 (OUT-S) RIM 432.64 CB#8, TYPE 1, LOCKING VANED GRATE STA 2+54.91 RIM 432.77 12" IE 429.33 (IN-N) 12" IE 429.33 (OUT-S) FL: 432.28 (MATCH EXISTING) TBC: 432.78 (MATCH EXISTING)1.5%FL: 432.29 TBC: 432.79 BW: 432.90BW: 432.85 BW: 432.77 (MATCH EXISTING) CONTACT phone: 253-301-4157 fax: 253-336-3950 beylerconsulting.com BEYLER CONSULTING OFFICE 5920 100TH ST SW, STE 25 Lakewood, WA 98499 Know what's below. before you dig.Call R LOT 5 FFE 437.50 LOT 6 FFE 437.00 LOT 7 FFE 437.50 CHELAN AVE NE 20 10 0 20 40 SCALE: 1" = 20' TRACT A STORMWATER/ UTILITIES TRACT (SEE SHEET C4 FOR CONTINUATION) SURVEY DATUM VERTICAL DATUM: NAVD88 BENCHMARK: CITY OF RENTON BENCHMARK #RENT159 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE INTERSECTION AT NE 12TH ST AND UNION AVE NE ELEVATION=415.961 HORIZONTAL BASIS OF BEARING: THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER CITY OF RENTON SHORT PLAT RECORDED UNDER RECORDING NUMBER 20120110900001 N 88°30'08" W EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. CHELAN AVE NE PROFILE SCALE: HORIZONTAL: 1"=20' VERTICAL:1"=5' EXISTING GRADE @ C/L OF ACCESS ROAD PROPOSED GRADE @ C/L OF ACCESS ROAD10'3 C7 4 C7 APPROX. LOCATION OF EXISTING 4" KING COUNTY WD 90 WATER MAIN (REF R-338610 FOR GENERAL LOCATION) APPROX. LOCATION OF EXISTING 8" DUCTILE IRON WATER MAIN (FIELD LOCATED) (REF W-332501) THAMI, ABDERRAHMANE & MAURA E. 1051 CHELAN AVE NE #1023059133 FISHER, SHERRIE M. 1045 CHELAN AVE NE #1023059473 SDC HOMES LLC 1039 CHELAN AVE NE #1023059472 20'APPROX. LOCATION OF EXISTING 8" SANITARY SEWER MAIN (FIELD LOCATED) (REF S-332504) PROPOSED 10' LANDSCAPE BUFFER (SEE SHEET LS-1 FOR DETAILS)12'5'PROPOSED PLANTER STRIP, VARIES 4.8'-8.0' PROPOSED 5' SIDEWALK PER COR STD PLAN 102 (TYP)35.5'23.5'PROPOSED 23.5' RIGHT OF WAY DEDICATION (RESIDENTIAL ACCESS ROADWAY) INTERSECTION STA 2+40.29 (CHELAN AVE NE) =STA 20+00.00 (ACCESS EASEMENT) INSTALL 12' RESIDENTIAL DRIVEWAY PER C.O.R. STANDARD DETAIL R1B - 104.3 F/L: 432.62 (SEE DRIVEWAY DETAIL SHEET C6) PROPOSED SAWCUT (TYP) PC STA 2+56.04 CL: 433.03 SC: 432.86 FL: 432.76 PRC STA 3+00.42 CL: 433.12 PT STA 3+44.79 CL: 433.66 END ROAD IMPROVEMENTS STA 4+04.20 CL: 435.05 PROPOSED 18' RIGHT OF WAY DEDICATION (SEE ADMINISTRATIVE STREET MODIFICATION APPROVAL UNDER LUA16-000897, MOD)END ROAD IMPROVEMENTSPROPOSED RAMP (SEE RAMP #1 DETAIL SHEET C6)11'APPROX. LOCATION OF EXISTING 8" SANITARY SEWER MAIN (FIELD LOCATED) (REF S-332504) EXISTING GRADE @ C/L OF ACCESS ROAD PROPOSED GRADE @ C/L OF ACCESS ROAD CHELAN AVE NE PLAN SCALE: 1"=20' LONG, GARY A. & DENISE Y. 1058 CHELAN AVE NE #1023059332 ABBREVIATION KEY SC: EXISTING GRADE ELEVATION @ PROPOSED SAWCUT FL: FINISHED GRADE ELEVATION @ FLOWLINE OF CURB A:FINISHED GRADE ELEVATION @ TOP OF ASPHALT PAVEMENT CL: EXISTING/FINISHED GRADE ELEVATION @ CENTERLINE OF ROAD UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. CB# 11, TYPE 2-48" ROUND SOLID LOCKING LID MARKED "STORM" STA 0+04.60, 15.12' L RIM 431.85 (MATCH EXISTING) 18" IE 415.08 (IN-E) 12" IE 415.58 (IN-N) 18" IE 414.93 (OUT-W) (CAST IN PLACE) (PER R-332511 AS-BUILT) REPLACE EXISTING TYPE 1 CB INSTALL FLOW SPLITTER (SEE DETAIL THIS SHEET)6.5'RIM ELEV = 432.60 OVERFLOW ELEV = 429.17 OUTLET IE = 427.67 BOTTOM ELEV = 424.002' (MIN.)TO DOWNSTREAMNETWORKTO EX. W Q FACILITY ORIFICE ELEV = 426.67 ORIFICE SIZING CALCULATIONS: WQ FLOWRATE (PER VUONG T.I.R.) = 0.11 CFS Q=CA(2GH)^0.5, WHERE C=0.62 (PLATE ORIFICE) G=32.2 FT/S^2 H=1.5 FT Q=0.11 CFS A=(0.11 CFS)/[0.62*(2*32.2*1.5)^0.5] A=0.0181 FT^2 A=πr^2 r=(0.0181/π)^0.5 = 0.076 D=r*2=0.152'=1.82" RESTRICTOR PLATE W/ 1.82" (DIAMETER) ORIFICE TO WQ 60" (TYP) SOLID BOTTOM 12" TEE/RISER 30" (MIN.) STANDPIPE BAFFLE TO CONTROL FLOATABLES 2D* BAFFLE TO CONTROL FLOATABLES 30" STANDPIPE TYPE 2-72" CB (PER COR STD 201.00)0.5' (MIN.)0.5' (MIN.)*NOTE: DIAMETER OF STANDPIPE 2X DIAMETER OF OUTLET PIPE AS STARTING POINT. DIAMETER OF STANDPIPE SHALL BE LARGE ENOUGH TO PASS THE 100-YEAR FLOWS WITHOUT INCREASING WQ FLOWS BY 10% TOP 12" TEE = 429.57 CB# 12 - FLOW SPLITTER DETAIL SCALE: NTS REFERENCE: FIGURE 6.2.5.B KCSWDM SECTION VIEW PLAN VIEW A PORTION OF SECTION 10, TOWNSHIP 23 N., RANGE 05 E., W.M.8'4.8'51'± PROTECT EX CB IN PLACE (REPLACE GRATE WITH SOLID LOCKING LID) INSTALL NO PARKING SIGN (PER MUTCD R7-1) (STA 3+64.87, 14.5' R)15.47'INSTALL NO PARKING SIGN (PER MUTCD R7-1) (STA 3+16.37, 14.5' R) 12" IE 428.52 (IN-E) (REPLACE EX. CONC PIPE WITH 12" CPE) SIDEWALK CONNECTION DETAIL SCALE: 1"=10'9'MANHOLE STEP (COR STD. 204.60) "TEE" SECTION WITH CLEANOUT (OR REMOVABLE BEND DOWN ELBOW) MANHOLE STEP (COR STD. 204.60) RECTANGULAR FRAME WITH VANED GRATE (COR STD. 204.00) (FIELD VERIFIED) TYPICAL PIPE DIMENSION NOTE THE PIPE DIMENSIONS SHOWN ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE STA 2+22.00, 18.06' R INSTALL USPS NEIGHBORHOOD DELIVERY AND COLLECTION BOX UNIT PER COR STANDARD PLAN H26 (SEE MAILBOX LOCATION NOTE THIS SHEET) MAILBOX LOCATION NOTE FINAL MAILBOX LOCATIONS HAVE YET TO BE DETERMINED AND/OR APPROVED BY THE RENTON USPS POST MASTER. FINAL MAILBOX LOCATION APPROVAL SHALL BE OBTAINED PRIOR TO CONSTRUCTION/INSTALLATION OF SPECIFIED COLLECTION BOX.R75'A: 433.20 A: 433.86 A: 435.12 IN COMPLIANCE WITH CITY OF RENTON STANDARDS PR16-000243TED-40-3924 BOUN SHORT PLATU16-00629716-0001245BOUN SHORT PLATCHELAN AVE NE GRADING/PAVING/STORMWATER PLAN & PROFILE LUA16-000124, SHPL-A, U16-006297CONSTRUCTION PLANS BOUN SHORT PLATTED-40-3924NOTE: ALL METAL PARTS SHALL BE CORROSION RESISTANT.2.1'2.1' *ROUND SOLID LOCKING LID CATCH BASINS PER COR STANDARD PLAN 204.50 (SEE SHEET C9.0) SAWCUT INTO EXISTING ASPHALT, AS NECESSARY, TO INSTALL STORM MAIN MODIFICATION. TRENCH RESTORATION AND OVERLAY SHALL BE PER CITY STD. 6.5' MIN WIDTH FOR TRANSVERSE PATCHES. PATCH SHALL EXTEND ACROSS EVERY AFFECTED TRAVEL LANE (NE 10TH STREET) r-392405 luasubmit postmaster approval for mailbox location to the city prior to construction permit approval. 10 existing catch basin and storm drain to be removed. clean up. should read 428.35 on metal post per cor std. plan 129 on metal post per cor std. plan 129 show existing 10" city water water crossing in profile. you cannot fit a 72" manhole here. it is too close to the existing city water main. 60" manhole will be the maximum allowed. show 60" manhole. the maximum size manhole that can be used is 60". see plan view redlines on this sheet. show existing 8" kcwd 90 water main in profile. 8" kcwd 90 water main 10" city of renton water main confirm with kcwd90 that you can set a structure this close to their water main. similar structure to the south was installed with a similar clearance. add note to plan instructing contractor to pothole to verify if a 60" manhole can be installed at this location. di 432.64 it does not appear that you can meet the required 2' clearance from the 30" standpipe and 12" tee based on the configuration of the existing pipes and where the ladder needs to be placed. you cannot use a 72" catch basin as it will conflict with an existing city water main. suggest using a 60" catch basin with a 2' diameter standpipe. you will have to rerun the calculations in the tir. a suggested layout is shown below in blue.2.0 ft2.0 ftsnipped from 2nd submittal. 24" diameter standpipe 2' minimum clearance to standpipe and riser tee new ladder location. extend storm further north? strongly suggest using standard size drill bits for the orifices. the orifices as shown are going to have to be laser cut instead of easily manufactured. suggest using 24" standpipe. see left