Loading...
HomeMy WebLinkAboutBoun Short Plat Minor CorrectionsMBMB0+00 1+00 2+00 3+ 0 0 4+00 4+2420+00435 43 3 434 436 437 CB#1 CB#4 32 LF - 12" CPE-SW @ S=0.50% EX. CB #4 (PER R-332511) 48 LF - 12" CPE-SW @ S=1.72% 39 LF - 12" CPE-SW @ S=0.74%CB#8 CB#9 4 3 4SSCB#10CB#11 39 LF - 12" DI@ S=0.50%43 LF - 12" CPE-SW @ S=28.42% CB#12 9 LF - 12" @ S=0.53% 410 415 420 425 430 435 440 445 450 410 415 420 425 430 435 440 445 450 0+00 1+00 2+00 3+00 4+00 4+40433.0432.8432.6432.6432.7432.7432.9433.1433.2433.1433.12433.3433.22434.1433.55434.7434.02435.1434.48435.1434.95435.42.33% PVI STA: 3+16.40 PVI ELEV: 433.000 K: 17.03 LENGTH: 50.00 LOW POINT STA: 3+01.70 LOW POINT ELEV: 433.12'BVC STA: 2+91.40BVC ELEV: 433.15EVC STA: 3+41.40EVC ELEV: 433.58GRADE BREAK STA = 4+04.20ELEV = 435.050.6% 2.0% CB#9, TYPE 1, LOCKING VANED GRATE STA 3+01.70 RIM 432.62 12" IE 429.62 (OUT-S) 39 LF - 12" CPE-SW @ S=0.74% 48 LF - 12" CPE-SW @ S=1.72% CB#1, TYPE 1, LOCKING VANED GRATE STA 2+07.22 RIM 432.32 12" IE 428.51 (IN-E) 12" IE 428.51 (IN-N) 12" IE 428.51 (OUT-W) 32 LF - 12" CPE-SW @ S=0.50%43 LF - 12" CPE-SW @ S=28.42 % CB#8, TYPE 1, LOCKING VANED GRATE STA 2+54.91 RIM 432.77 12" IE 429.33 (IN-N) 12" IE 429.33 (OUT-S) CB#12, TYPE 1, LOCKING VANED GRATE STA 0+56.03 RIM 432.64+/- (MATCH EX) 12" IE 427.61 (IN-N) 12" IE 427.61 (OUT-S) 9 LF - 12" CPE-SW @ S=0.53% EX. CB #4 (PER R-332511), TYPE 1 STA 1+96.01, 15.15' L RIM 432.20 12" IE 428.35 (IN-E) 12" IE 428.35 (IN-N) 12" IE 428.35 (OUT-S) CB# 10, TYPE 2-60" (FS), SOLID LOCKING LID STA 0+47.12, 13.79' L 12" IE 427.56 (IN-N) 12" IE 427.57 (IN-E) 12" IE 427.67 (OUT-W) 12" IE 427.67 (OUT-S) RIM 432.64 FL: 432.28 (MATCH EXISTING) TBC: 432.78 (MATCH EXISTING)1.5%FL: 432.29 TBC: 432.79 BW: 432.90BW: 432.85 BW: 432.77 (MATCH EXISTING) CONTACT phone: 253-301-4157 fax: 253-336-3950 beylerconsulting.com BEYLER CONSULTING OFFICE 5920 100TH ST SW, STE 25 Lakewood, WA 98499 Know what's below. before you dig.Call R LOT 5 FFE 437.50 LOT 6 FFE 437.00 LOT 7 FFE 437.50 CHELAN AVE NE 20 10 0 20 40 SCALE: 1" = 20' TRACT A STORMWATER/ UTILITIES TRACT (SEE SHEET C4 FOR CONTINUATION) SURVEY DATUM VERTICAL DATUM: NAVD88 BENCHMARK: CITY OF RENTON BENCHMARK #RENT159 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE INTERSECTION AT NE 12TH ST AND UNION AVE NE ELEVATION=415.961 HORIZONTAL BASIS OF BEARING: THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER CITY OF RENTON SHORT PLAT RECORDED UNDER RECORDING NUMBER 20120110900001 N 88°30'08" W EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. CHELAN AVE NE PROFILE SCALE: HORIZONTAL: 1"=20' VERTICAL:1"=5' EXISTING GRADE @ C/L OF ACCESS ROAD PROPOSED GRADE @ C/L OF ACCESS ROAD10'3 C7 4 C7 APPROX. LOCATION OF EXISTING 4" KING COUNTY WD 90 WATER MAIN (REF R-338610 FOR GENERAL LOCATION) APPROX. LOCATION OF EXISTING 8" DUCTILE IRON WATER MAIN (FIELD LOCATED) (REF W-332501) THAMI, ABDERRAHMANE & MAURA E. 1051 CHELAN AVE NE #1023059133 FISHER, SHERRIE M. 1045 CHELAN AVE NE #1023059473 SDC HOMES LLC 1039 CHELAN AVE NE #1023059472 20'APPROX. LOCATION OF EXISTING 8" SANITARY SEWER MAIN (FIELD LOCATED) (REF S-332504) PROPOSED 10' LANDSCAPE BUFFER (SEE SHEET LS-1 FOR DETAILS)12'5'PROPOSED PLANTER STRIP, VARIES 4.8'-8.0' PROPOSED 5' SIDEWALK PER COR STD PLAN 102 (TYP)35.5'23.5'PROPOSED 23.5' RIGHT OF WAY DEDICATION (RESIDENTIAL ACCESS ROADWAY) INTERSECTION STA 2+40.29 (CHELAN AVE NE) =STA 20+00.00 (ACCESS EASEMENT) INSTALL 12' RESIDENTIAL DRIVEWAY PER C.O.R. STANDARD DETAIL R1B - 104.3 F/L: 432.62 (SEE DRIVEWAY DETAIL SHEET C6) PROPOSED SAWCUT (TYP) PC STA 2+56.04 CL: 433.03 SC: 432.86 FL: 432.76 PRC STA 3+00.42 CL: 433.12 PT STA 3+44.79 CL: 433.66 PROPOSED 18' RIGHT OF WAY DEDICATION (SEE ADMINISTRATIVE STREET MODIFICATION APPROVAL UNDER LUA16-000897, MOD)END ROAD IMPROVEMENTSPROPOSED RAMP (SEE RAMP #1 DETAIL SHEET C6)11'APPROX. LOCATION OF EXISTING 8" SANITARY SEWER MAIN (FIELD LOCATED) (REF S-332504) EXISTING GRADE @ C/L OF ACCESS ROAD PROPOSED GRADE @ C/L OF ACCESS ROAD CHELAN AVE NE PLAN SCALE: 1"=20' LONG, GARY A. & DENISE Y. 1058 CHELAN AVE NE #1023059332 ABBREVIATION KEY SC: EXISTING GRADE ELEVATION @ PROPOSED SAWCUT FL: FINISHED GRADE ELEVATION @ FLOWLINE OF CURB A:FINISHED GRADE ELEVATION @ TOP OF ASPHALT PAVEMENT CL: EXISTING/FINISHED GRADE ELEVATION @ CENTERLINE OF ROAD UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. CB# 11, TYPE 2-48" ROUND SOLID LOCKING LID STA 0+04.60, 15.12' L RIM 431.85 (MATCH EXISTING) 18" IE 415.08 (IN-E) 12" IE 415.58 (IN-N) 18" IE 414.93 (OUT-W) (CAST IN PLACE) (PER R-332511 AS-BUILT) REPLACE EXISTING TYPE 1 CB INSTALL FLOW SPLITTER (SEE DETAIL THIS SHEET)6.5'RIM ELEV = 432.64 OVERFLOW ELEV = 429.17 OUTLET IE = 427.67 BOTTOM ELEV = 424.002' (MIN.)TO DOWNSTREAMNETWORKTO EX. WQ FACILITY ORIFICE ELEV = 426.67 ORIFICE SIZING CALCULATIONS: WQ FLOWRATE (PER VUONG T.I.R.) = 0.11 CFS Q=CA(2GH)^0.5, WHERE C=0.62 (PLATE ORIFICE) G=32.2 FT/S^2 H=1.5 FT Q=0.11 CFS A=(0.11 CFS)/[0.62*(2*32.2*1.5)^0.5] A=0.0181 FT^2 A=πr^2 r=(0.0181/π)^0.5 = 0.076 D=r*2=0.152'=1.82" RESTRICTOR PLATE W/ 1.82" (DIAMETER) ORIFICE TO WQ 60" (TYP) SOLID BOTTOM 12" TEE/RISER 30" (MIN.) STANDPIPE BAFFLE TO CONTROL FLOATABLES 2D* BAFFLE TO CONTROL FLOATABLES 30" STANDPIPE TYPE 2-60" CB (PER COR STD 201.00)0.5' (MIN.)0.5' (MIN.)*NOTE: DIAMETER OF STANDPIPE 2X DIAMETER OF OUTLET PIPE AS STARTING POINT. DIAMETER OF STANDPIPE SHALL BE LARGE ENOUGH TO PASS THE 100-YEAR FLOWS WITHOUT INCREASING WQ FLOWS BY 10% TOP 12" TEE = 429.57 CB# 10 - FLOW SPLITTER DETAIL SCALE: NTS REFERENCE: FIGURE 6.2.5.B KCSWDM SECTION VIEW PLAN VIEW A PORTION OF SECTION 10, TOWNSHIP 23 N., RANGE 05 E., W.M.8'4.8'51'± PROTECT EX CB IN PLACE (REPLACE GRATE WITH SOLID LOCKING LID) INSTALL NO PARKING SIGN (PER MUTCD R7-1) ON METAL POST PER COR STD. PLAN 129 (STA 3+64.87, 14.5' R)15.47'INSTALL NO PARKING SIGN (PER MUTCD R7-1) ON METAL POST PER COR STD. PLAN 129 (STA 3+16.37, 14.5' R) 12" IE 428.35 (IN-E) (REPLACE EX. CONC PIPE WITH 12" CPE) SIDEWALK CONNECTION DETAIL SCALE: 1"=10'9'"TEE" SECTION WITH CLEANOUT (OR REMOVABLE BEND DOWN ELBOW) MANHOLE STEP (COR STD. 204.60) (FIELD VERIFIED) TYPICAL PIPE DIMENSION NOTE THE PIPE DIMENSIONS SHOWN ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE STA 2+22.00, 18.06' R INSTALL USPS NEIGHBORHOOD DELIVERY AND COLLECTION BOX UNIT PER COR STANDARD PLAN H26 R75'A: 433.20 A: 433.86 A: 435.12 IN COMPLIANCE WITH CITY OF RENTON STANDARDS PR16-000243R-392405 BOUN SHORT PLATU16-006297LUA 16-0001245BOUN SHORT PLATCHELAN AVE NE GRADING/PAVING/STORMWATER PLAN & PROFILE LUA16-000124, SHPL-A, U16-006297CONSTRUCTION PLANS BOUN SHORT PLATTED-40-3924NOTE: ALL METAL PARTS SHALL BE CORROSION RESISTANT. *ROUND SOLID LOCKING LID CATCH BASINS PER COR STANDARD PLAN 204.50 (SEE SHEET C9.0) SAWCUT INTO EXISTING ASPHALT, AS NECESSARY, TO INSTALL STORM MAIN MODIFICATION. TRENCH RESTORATION AND OVERLAY SHALL BE PER CITY STD. 6.5' MIN WIDTH FOR TRANSVERSE PATCHES. PATCH SHALL EXTEND ACROSS EVERY AFFECTED TRAVEL LANE (NE 10TH STREET) END ROAD IMPROVEMENTS STA 4+04.20 CL: 435.05 INSTALL (2) 8' TYPE 3 ROAD BARRICADES PER COR STD DETAIL H18 & H18.1 EX 8" KCWD 90 WATER MAIN EX 10" CITY OF RENTON WATER MAIN EX CATCH BASIN AND STORM DRAIN TO BE REMOVED EX 10" CITY WATER MAIN EX 8" KCWD 90 WATER MAIN CONTRACTOR TO POTHOLE TO VERIFY IF A 60" MANHOLE CAN BE INSTALLED EX 149 LF - @ S=0.53% NOW 139 LF - @ S=0.53% CONTRACTOR TO POTHOLE TO VERIFY IF A 60" MANHOLE CAN BE INSTALLED 24" Ø SOLID LOCKING LID 2.44'1.72 ' MANHOLE STEP (COR STD. 204.60) 4/25/18 21+94438 438 EX. SSMH #5552, TYPE 1-48" STA 50+41.83, 1.41' L RIM 437.54 72 LF - 8" PVC SDR-35 SSMH #2, TYPE 1-54" STA 52+48.56, 6.00' L RIM 437.00LOT 55,731 SF5,718 SFTRACT A7,277 SFS50+00 51+00 52+00 SSMH #1, TYPE 1-54" STA 51+14.18, 7.66' L RIM 432.04 136 LF - 8" PVC SDR-35 6 LF - 8" PVC SDR-35 420 425 430 435 440 445 450 455 420 425 430 435 440 445 450 455 51+00 52+00 52+70437.6437.4437.32437.3437.09437.3436.87437.8436.68438.1436.56437.9436.49437.8436.48437.7436.53437.6436.63436.9436.802 5 . 0 0% 1.15%1.00% PVI STA: 51+68.15 PVI ELEV: 436.077 K: 69.68 LENGTH: 150.00 LOW POINT STA: 51+73.47 LOW POINT ELEV: 436.48 BVC STA: 50+93.15BVC ELEV: 436.94EVC STA: 52+43.15EVC ELEV: 436.83GRADE BREAK STA = 50+49.26ELEV = 437.45GRADE BREAK STA = 52+56.71ELEV = 436.31GRADE BREAK STA = 52+54.19 ELEV = 436.94 SSMH #1, TYPE 1-54" STA 51+14.18, 7.66' L 8" IE 430.95 (IN-N) 8" IE 430.85 (OUT-SE) (PER CITY OF RENTON STD 400.2 - SHALLOW MANHOLES) RIM 432.04 SSMH #2, TYPE 1-54" 8" IE 431.73 (IN-N) 8" IE 431.63 (OUT-S) (PER CITY OF RENTON STD 400.2 - SHALLOW MANHOLES) RIM 437.00 STA 52+48.56, 6.00' L 72 LF - 8" PVC SDR-35 @ S=0.50% 136 LF - 8" PVC SDR-35 @ S=0.50% EX. SSMH #5552, TYPE 1-48" STA 50+41.83, 1.41' L 6" IE 430.33 (IN-N) (TO BE REMOVED) 8" IE 430.49 (IN-NW) (NEW) CORE DRILL & RECHANNEL MANHOLE 8" IE 430.39 (OUT-S) LADDER NORTHEAST RIM 437.54 6 LF - 8" PVC SDR-35 @ S=0.65% (STUB W/ CAP) PIPE CROSSING TABLE PIPE CROSSING # 7 8 9 FG ELEV: 437.3± 437.2± 436.6± TOP PIPE SIZE/ NETWORK SEWER/8" SEWER/8" SEWER/8" BOTTOM OF TOP PIPE 430.6 430.7 431.1 BOTTOM PIPE SIZE/ NETWORK STORM/12" STORM/12" STORM/6" TOP OF BOTTOM PIPE 429.5 430.1 430.6 APPROX. VERTICAL SEPARATION 1.1' 0.6' 0.5' CONTACT phone: 253-301-4157 fax: 253-336-3950 beylerconsulting.com BEYLER CONSULTING OFFICE 5920 100TH ST SW, STE 25 Lakewood, WA 98499 Know what's below. before you dig.Call R CHELAN PLACE NE SEWER PROFILE SCALE:HORIZONTAL:1"=20' VERYTICAL:1"=5' PROPOSED STORM MAIN (TYP) (SEE SHEET C4 FOR DETAILS) LOT 1 FFE 438.50 LOT 2 FFE 438.00 LOT 3 FFE 438.50 LOT 4 FFE 438.00 CHELAN PLACE NE PROPOSED STORM MAIN (TYP) (SEE SHEET C4.0 FOR DETAILS) EXISTING GRADE @ RIGHT OF WAY CENTERLINE (TYP) PROPOSED GRADE @ RIGHT OF WAY CENTERLINE (TYP) EXISTING GRADE @ RIGHT OF WAY CENTERLINE (TYP) PROPOSED GRADE @ RIGHT OF WAY CENTERLINE (TYP) UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. LOT 5 FFE 437.50 LOT 6 FFE 437.00 LOT 7 FFE 437.50 16'8" PVC CAPACCESS EASEMENTPROPOSED WATER MAIN (SEE SHEET C12 FOR DETAILS) SSCO #1 RIM 437.6 50+77.48, 20' R 6" IE 431.24 (IN-OUT) LOT 1 STUB MAIN IE 430.68 LOT 7 STUB MAIN IE 431.06 LOT 2 STUB MAIN IE 431.08 LOT 6 STUB MAIN IE 431.24 LOT 3 STUB MAIN IE 431.33 LOT 4 STUB MAIN IE 431.43 LOT 5 STUB MAIN IE 431.44 PROPOSED WATER MAIN (TYP) (SEE SHEET C12.0 FOR DETAILS) 8" PVC CAP PC7 PC8 PC9 PIPE CROSSING #7 & 8 SEE TABLE THIS SHEET PIPE CROSSING #9 SEE TABLE THIS SHEET SSCO #7 RIM 437.1 51+42.71, 18' L 6" IE 431.38 (IN-OUT) SSCO #2 RIM 437.4 51+46.09, 18' R 6" IE 431.56 (IN-OUT) SSCO #6 RIM 436.8 51+78.47, 18' L 6" IE 431.56 (IN-OUT) SSCO #5 RIM 437.2 52+17.71, 18' L 6" IE 431.76 (IN-OUT) SSCO #3 RIM 437.7 51+96.66, 18' R 6" IE 431.81 (IN-OUT) SSCO #4 RIM 437.4 52+16.11, 18' R 6" IE 431.91 (IN-OUT) CHELAN PLACE NE SEWER PLAN SCALE:HORIZONTAL:1"=20' 20 10 0 20 40 SCALE: 1" = 20' 1.ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2.THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4.A PRE-CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5.CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7.PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8.A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9.THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS-BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10.BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 11.OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY 12.DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON-SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16.IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2’ DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. SANITARY SEWER NOTES AND SPECIFICATIONS 24 LF - 6" PVC SDR-35 @ 2% (MIN.) 24 LF - 6" PVC SDR-35 @ 2% (MIN.) 28 LF - 6" PVC SDR-35 @ 2% (MIN.) 12 LF - 6" PVC SDR-35 @ 2% (MIN.) 12 LF - 6" PVC SDR-35 @ 2% (MIN.) 12 LF - 6" PVC SDR-35 @ 2% (MIN.) A PORTION OF SECTION 10, TOWNSHIP 23 N., RANGE 05 E., W.M. SURVEY DATUM VERTICAL DATUM: NAVD88 BENCHMARK: CITY OF RENTON BENCHMARK #RENT159 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE INTERSECTION AT NE 12TH ST AND UNION AVE NE ELEVATION=415.961 HORIZONTAL BASIS OF BEARING: THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER CITY OF RENTON SHORT PLAT RECORDED UNDER RECORDING NUMBER 20120110900001 N 88°30'08" W EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. 24 LF - 6" PVC SDR-35 @ 2% (MIN.) (FIELD VERIFIED)TYPICAL PIPE DIMENSION NOTE THE PIPE DIMENSIONS SHOWN ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE IN COMPLIANCE WITH CITY OF RENTON STANDARDS PR16-000243S-392401 BOUN SHORT PLATU16-006297LUA 16-00012415BOUN SHORT PLATSEWER PLAN & PROFILE LUA16-000124, SHPL-A, U16-006297CONSTRUCTION PLANS BOUN SHORT PLATWWP-27-3924* ETHAFOAM PAD REQUIRED * 4/25/18 fix.