HomeMy WebLinkAboutLHS 265100-06.0 Lighting Streetlight Cabinet - Shop Drawings - HEI_Review RESPONSIBLE CONTRACTOR/SUPPLIER: __________________ RE: _________________________ DATE SUBMITTED: _______ SUBMITTAL TRANSMITTAL TO:CC:ATTN: SPECIFICATION: _________ Transmittal # ATTACHMENT: GENERAL CONTRACTOR REMARKS: Project:Cornerstone General Contractors 11805 N. Creek Pkwy S., Ste 115 Bothell, WA 98011 Phone: (425) 481-7460 SUBMITTAL SEQUENCE #: _____ SUBMITTAL TYPE: REQUESTED RETURN DATE: _______CONTRACTOR'S STAMPARCHITECT REVIEW:ARCHITECTS STAMPENGINEER/CONSULTANT REVIEW:ENGINEER'S STAMPCONTRACTOR'S SUBMITTAL REVIEW THIS STAMP CERTIFIES THAT THE G.C. HAS REVIEWED THE ABOVE ITEMS SUBMITTED AND HAVE NOTED ANY COMMENTS HEREIN AS DEEMED REQUIRED. THIS REVIEW DOES NOT RELEIVE THE SUBCONTRACTOR OR SUPPLIER FROM FULL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND SCOPE OF WORK REVIEWED BY:Sean McCauley 05/24/2023 NO EXCEPTIONS REVISE & RESUBMIT REJECTED4 Engineer’s review is for general conformance with the design concept andContract Documents. Markings or comments shall not be construed asrelieving the Contractor from compliance with the project plans andspecifications, not departures therefrom.The contractor remains responsible for details and accuracy, for confirmingand correlating all quantities and dimensions, for selecting fabricationprocesses, for techniques of assembly, and for performing their work in asafe manner. Contractor to verify all dimensions at job site before orderingmaterials and equipment. MAKE CORRECTIONS NOTED;NO RESUBMITTAL REQUIRED REFER TO SUBMITTAL COMMENT SHEET DATE 05/25/2023 Review Action Code: NE no exceptions CN make correction noted, no RJ rejected, revise & resubmit resubmittal required RR revise & resubmit SUB submit NR not reviewed submittal comment sheet N o. 2 6 S U B -2 7 PROJECT Renton SD Lindbergh HS Mod REVIEWED BY Jeff Hoover, Taylor VanderKley HARGIS PROJECT NO. 21064.01 RECEIVED DATE May 24, 2023 CONTRACTOR SUBMITTAL NO. 265100-5.1 – Street Lighting Service Cabinet HARGIS SUBMITTAL NO. 26SUB-27 REVIEWED DATE May 25, 2023 Engineer's review is for general conformance with the design concept and Contract Documents. Markings or comments shall not be construed as relieving the Contractor from compliance with the Contract Documents. The Contractor remains responsible for details and accuracy, for confirming and correlating quantities, dimensions and weights, for selecting fabrication processes, for techniques of assembly and construction, for performing their work in a safe manner and providing complete and operating systems. Contractor to verify quantities, dimensions, and weights before ordering materials and equipment. Note: First review uses standard text font. For subsequent reviews, items indicated in bold text were reviewed as part of this submittal. spec section & paragraph product description review action comments Section 260500 General Electrical Provisions 1.3.J. SOV Previously Approved (NE) Section 260519 Wire and Cables 1.3.B. Product Data Previously Approved (26SUB-02: CN) Section 260521 Metal Clad Cables 1.3.B. Product Data Previously Approved (26SUB-02: NE) Section 260526 Grounding 1.3.B. Product Data SUB 1.3.C. Shop Drawings SUB Section 260529 Supporting Devices 1.3.B. Product Data Previously Approved (26SUB-02: NE) Section 260533 Raceway Systems 1.3.B. Product Data Previously Approved (26SUB-02: NE) Section 260534 Outlet Boxes 1.3.B. Product Data Previously Approved (26SUB-02: NE) Section 260535 Floor Outlet Devices 1.3.B. Product Data SUB Section 260536 Cable Trays 1.3.B. Product Data Previously Approved (26SUB-05: NE) 1.3.C. Shop Drawings N/A May 25, 2023 Renton SD CONTRACTOR SUBMITTAL NO. 265100-5.1 – Street Lighting Service Cabinet HARGIS SUBMITTAL NO. 26SUB-27 page 2 Review Action Code: NE no exceptions CN make correction noted, no resubmittal required RJ rejected, revise & resubmit SUB submit RR revise & resubmit NR not reviewed spec section & paragraph product description review action comments Section 260543 Underground Vaults and Raceway 1.3.B. Product Data Previously Reviewed (26SUB-15: CN) Previously Reviewed (26SUB-19: RJ) Previously Reviewed (26SUB-20: NE) 1.3.C. Shop Drawings Previously Reviewed (26SUB-15: NE) Previously Reviewed (26SUB-20: NE) Section 260548 Vibration Isolation and Seismic Control for Electrical Systems 1.3.B. Product Data Previously Reviewed (26SUB-03: NE) 1.3.C. Delegated Design Submittal SUB 1.3.D. Welding Certificates SUB Section 260553 Electrical Identification 1.3.B. Product Data Previously Reviewed (26SUB-13: NE) Section 260573 Electrical Power Studies 1.3.B. Study Outline Previously Reviewed (26SUB-23: NE) 1.3.C. Initial Submittals Previously Reviewed (26SUB-23: NE) 1.3.D. Final Calculations & Study Previously Reviewed (26SUB-24: NE) Section 260810 Electrical Testing 1.3.B. Qualifications SUB 1.3.C. Testing Plan and Schedule SUB 1.3.D. Test Procedures SUB 1.3.E. Detailed Report of Testing Functions SUB Section 260923 Lighting and Receptacle Controls 1.3.B. Product Data Previously Reviewed (26SUB-06: NE) 1.3.C. Shop Drawings Previously Reviewed (26SUB-13: RR) Previously Reviewed (26SUB-21: NE) Section 262200 Transformers 1.3.B. Product Data Previously Reviewed (26SUB-03: NE) 1.3.C. Shop Drawings Previously Reviewed (26SUB-03: NE) Section 262410 Service Entrance 1.3.B. Product Data SUB 1.3.C. Shop Drawings SUB Section 262416 Panelboards 1.3.B. Product Data Previously Reviewed (26SUB-03: CN) Section 262726 Wiring Devices 1.3.B. Product Data Previously Reviewed (26SUB-03: CN) 1.3.B. Missing Product Data – Cord Reels Previously Reviewed (26SUB-08: RR) May 25, 2023 Renton SD CONTRACTOR SUBMITTAL NO. 265100-5.1 – Street Lighting Service Cabinet HARGIS SUBMITTAL NO. 26SUB-27 page 3 Review Action Code: NE no exceptions CN make correction noted, no resubmittal required RJ rejected, revise & resubmit SUB submit RR revise & resubmit NR not reviewed spec section & paragraph product description review action comments Previously Reviewed (26SUB-10: CN) 1.3.B Missing Product Data – GFCI Controlled Receptacles Previously Reviewed (26SUB-08: NE) Section 262813 Overcurrent Protective Devices 1.3.B. Product Data - Fuses Previously Reviewed (26SUB-04: NE) 1.3.B Product Data – Circuit Breakers Previously Reviewed (26SUB-16: NE) Section 262816 Disconnect Switches and Enclosed Circuit Breakers 1.3.B. Product Data Previously Reviewed (26SUB-04: CN) 1.3.B Product Data – D-Y1A Previously Reviewed (26SUB-08: NE) Section 263353 Uninterruptible Power Supply Systems 1.3.B. Product Data SUB 1.3.C. Shop Drawings SUB 1.3.E. Report SUB 1.3.F. Certification SUB Section 263600 Transfer Switches 1.3.B. Product Data Previously Reviewed (26SUB-18: NE) Section 264313 Surge Protective Devices 1.3.B. Certifications Previously Reviewed (26SUB-11: NE) 1.3.C. Product Data Previously Reviewed (26SUB-04: RR) Previously Reviewed (26SUB-09: CN) Section 265100 Lighting 1.3.B. Product Data Previously Reviewed (26SUB-01: CN) Previously Reviewed (26SUB-02: CN) 1.3.B Product Data - Street Lighting Previously Reviewed (26SUB-07: NE) Previously Reviewed (26SUB-09: CN) Previously Reviewed (26SUB-25: NE/CN) Previously Reviewed (26SUB-26R1: CN) 1.3.C. Shop Drawings – Street Lighting Service Cabinet NE 1.3.C. Shop Drawings Previously Reviewed (26SUB-14: CN) Previously Reviewed (26SUB-22: CN) m:\jobs\21\21064\ca\submittals\division 26\21064.01esub 20230525 lindbergh hs sub26-27.docx 8365 Hogum Bay Lane NE - Lacey, WA 98516 Office 360-491-9621 / Fax 360-438-6920 Page 1 of 1 Contractor # PREMIPE935QL Electrical Shop Drawings Submittal Project: Lindberg High School 16426 128th Ave SE Renton, WA 98058 Owner: Renton School District 7812 S 124th Street Renton WA 980178 Architect: Bassetti Architects 71 Columbia St, Ste 501 Seattle, WA 98104 Electrical Engineer: Hargis Engineers Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 General Contractor: Cornerstone General Contractors 11805 North Creek Pkwy S, Ste 115 Bothell, Wa 98011 For Information regarding this project, please contact: Jon Wood 360.350.7111 Div 265100 Lighting PPE Comments Reviewer response Street Lighting Service Cabinet LINDBERGH HS GEXPRO for PREMIER POWER SKYLINE ELECTRIC & MFG. CO. SCALE DATE / DRAWN BY DRAWING NO. N.T.S. 5-10-23 / C.S.T. 68035 1 2 3 4 5 6 FRONT SIDE CITY OF RENTON SKYLINE SERIES# 64380-5G 1 REQUIRED SEE COMPONENT SCHEDULE AND CABINET SPECIFICATIONS THE METER DOOR IS REMOVABLE AND COMES STANDARD HINGED ON THE LEFT. HINGING ON THE RIGHT IS AVAILABLE AS A NO-CHARGE OPTION FOOTPRINT DEADFRONT SERVICE WIREWAY WIRING SCHEMATIC METER BASE MAIN CONTROL LTG. GROUND FAULT RECEPT. NEUTRAL GROUND PHOTO CELL TEST SWITCH 120/240V, SINGLE PHASE, 3 WIRE CITY OF RENTON SERVICE CABINET PER STANDARD PLANS 122.1, 122.2 SKYLINE SERIES# 64380-5G COMPONENT SCHEDULE 1 METERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5TH JAW AT 9:00 POSITION 2 PANELBOARD: 120/240 VAC, 250 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, 65K AIC SERIES RATED MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON PDD22G0200TFFJ BOLT-ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE * - 40/1 SIGNAL (IF PRESENT) * - 40/1 AUXILIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 15/1 CONTROL 3 - 20/1 SPARE (PLEASE CONFIRM BREAKER SCHEDULE, NONE PROVIDED) 3 CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 8910DPA34V02 – 1 REQUIRED 4 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 5 PHOTO-CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) 6 GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8” 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2” ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, “BEST” LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER-TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 – REQUIRED UL LISTED PER STANDARD #508A “SUITABLE FOR USE AS SERVICE ENTRANCE” LINDBERGH HS GEXPRO P.O.# S136551006 PREMIER POWER 5-10-23 C.S.T. S.O.# 68035 SKYLINE ELECTRIC & MFG. COMPANY I N C O R P O R A T E D Switchboards Panelboards Steel Cabinets UL Registered Metal Punching . . Forming . . Welding Industrial Control Panels 3619 7TH AVENUE SOUTH SEATTLE, WASHINGTON 98134 TELEPHONE (206) 682-4422 FAX (206) 682-0927