Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P_Sounders ELEC Drawings PERMIT SET_20230509_v1
APPLICABLE CODES & STANDARDS BUILDING CODE 2018 INTERNATIONAL BUILDING CODE (IBC) WAC 51-50 WASHINGTON STATE BUILDING CODE (IBC) ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE ELECTRICAL CODE 2020 NFPA 70 E (NEC) WAC 296-46B ELECTRICAL SAFETY STANDARDS, ADMINISTRATION AND INSTALLATION 8" POKE-THRU - CONF ROOMS • 8" CORE • WIREMOLD 8AT • (2) 5-20R DUPLEX RECEPTACLES • (1) 1-GANG DATA • (1) 2- GANG AV • PROVIDE (1) 1-1/4"C FOR AV • PROVIDE (1) 1"C FOR DATA 4" POKE-THRU - COMMON AREAS - POWER ONLY • 4" CORE • WIREMOLD RC4 • (2) 5-20R DUPLEX RECEPTACLES 4" POKE-THRU & AV PASS THRU • (1) 4" CORE AND (1) 2" CORE • WIREMOLD RC4 • (2) 5-20R DUPLEX RECEPTACLES • PROVIDE (1) 1"C FOR DATA • PROVIDE (1) 1-1/4"C FOR AV 6" POKE-THRU (NEIGHBORHOODS) • 6" CORE • WIREMOLD 6AT • (2) 5-20R DUPLEX RECEPTACLES • PROVIDE (1) 1"C FOR DATA. POKE THRU & FLOORBOX DESIGNATIONS A F FLOORBOX - COMMON AREAS, OPEN OFFICE. • WIREMOLD EFB45 • (2) 5-20R DUPLEX RECEPTACLES • (1) 1-GANG FOR DATA. • PROVIDE (1) 1"C FOR DATA. • FLOORBOX - CONF ROOMS, RECEPTION • WIREMOLD EFB6 • (2) 5-20R DUPLEX RECEPTACLES • (4) 1-GANG FOR DATA / AV • PROVIDE (1) 1-1/4"C FOR AV. • PROVIDE (1) 1"C FOR DATA. A/VA/V A/V A/V B C D G 4" POKE-THRU FURNITURE FEED • 4" CORE • WIREMOLD RC7 • (1) 3/4"C FOR POWER • (1) 1-1/4"C FOR DATA E SINGLE BUTTON DIMMER SWITCH 1-ZONE CONTROL MULTI-BUTTON DIMMER FOR NEIGHBORHOODS, TEAM AND CONFERENCE ROOMS. PROVIDE DIM CONTROL PER ZONE OR VIA SCENE SELECTION DEPENDING ON SPACE TYPE. STANDARD CEILING MOUNTED OCCUPANCY SENSOR DUAL TECH CEILING MOUNTED OCC SENSOR MULTI-ZONE PHOTOSENSOR ON/OFF SWITCHED ROOM CONTROLLER 0-10V DIMMING ROOM CONTROLLER, NUMBER DENOTES QUANTITY OF RELAYS. UNIVERSAL PHASE DIMMING ROOM CONTROLLER WITH 2 RELAYS LIGHTING CONTROL HEAD END WITH ENCLOSURE LOW VOLTAGE OVERRIDE SWITCH FOR HALLWAY LIGHTING 0-10V DIMMER/OCCUPANCY SENSOR SWITCH (FOCUS, PHONE & CODE ROOMS). PROGRAM SWITCHES TO BE AUTO-ON TO 50% VERSUS VACANCY MODE. STANDARD OCC SENSOR ON/OFF SWITCH. 6-ZONE TOUCHSCREEN LIGHTING CONTROL STATION WITH RS-232 INTERFACE FOR AV SYSTEM. 5 BUTTON SCENE CONTROL SWITCH. LIGHTING SYMBOLS RC3 S RC1 RCU DLV SDLVabc PS LCH SLV1 SDa SOS OS1 OS LCS SC NEMA L6-20R (208V/1P/20A), #12 CONDUCTORS NEMA L6-30R (208V/1P/30A), #10 CONDUCTORS NEMA L5-20R (120V/1P/20A), #12 CONDUCTORS NEMA L5-30R (120V/1P/30A), #10 CONDUCTORS NEMA L21-20R (208V/3P/20A) NEMA L21-30R (208V/3P/30A) NEMA L15-60P (208V/3PH/60A), 4P-5W CARD READER ROUGH-IN G POWER SYMBOLS LEGEND: E F A B C D J DUPLEX RECEPTACLE - STANDARD DUPLEX RECEPTACLE - ABOVE COUNTER +43" UON DUPLEX RECEPTACLE - DEDICATED "WA1-5a" = FULLY CONTROLLED/SWITCHED VIA RELAY. "WA1-5,5a" = SPLIT-WIRED, HALF CONTROLLED/SWITCHED. PULL ADDITIONAL SWITCHED HOT CONDUCTOR VIA IN-CEILING RELAY. G = GFCI RECEPTACLE QUAD RECEPTACLE - STANDARD QUAD RECEPTACLE - ABOVE COUNTER +43" UON QUAD RECEPTACLE - DEDICATED J-BOX - SYMBOLIC, NOT ACTUAL LOCATION DATA SINGLE-GANG ROUGH-IN DUPLEX RECEPTACLE - CEILING MOUNTED DUPLEX RECEPTACLE - TVTV QUAD RECEPTACLE - CEILING MOUNTED DATA SINGLE-GANG ROUGH-IN, CEILING MOUNTED QUAD RECEPTACLE - SWITCHED/CONTROLLED DUPLEX RECEPTACLE - SWITCHED/CONTROLLED A AV SINGLE-GANG ROUGH-IN, TV DISCONNECT NON-FUSED DISCONNECT FUSED EQUIPMENT CONNECTION HOME RUN, TICK MARKS INDICATE QTY OF CONDUCTORS. LONG DASH=N, SHORT DASH=PH, DOT=GND CR DRAWING INFORMATION PERMIT SET 04/24/23 ELECTRICAL DESIGN DRAWINGS ARE BASED ON THE FOLLOWING MODELS/SETS FROM THE FOLLOWING TRADES. COORDINATE AND VERIFY WITH LATEST ISSUED DRAWINGS OF THE VARIOUS TRADES AS NEEDED. ARCHITECTURAL/LIGHTING: REVIT MODEL DATED 04/12/23 MECHANICAL AND PLUMBING COORDINATION SET REC'D 04/18/23 SITE/CIVIL/IRRIGATION PERMIT SET DATED 02/17/23 FIRE ALARM, SECURITY, TELECOMM NO DESIGN DRAWINGS PROVIDED AT TIME OF THIS DELIVERABLE. © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:34 PM E000 SYMBOLS AND ABBREVATIONS 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET ELECTRICAL SHEET INDEX Sheet Number Sheet Name E000 SYMBOLS AND ABBREVATIONS E101 ONE LINE DIAGRAM E102 ONE LINE DIAGRAM E103 LIGHTING FIXTURE SCHEDULE E104 ENERGY CODE FORMS E200 SITE POWER PLAN E201 MAINTENANCE BUILDING POWER AND MECH PLAN E202 MAINTENANCE BUILDING LIGHTING PLAN E203 PITCH 3 LIGHTING PLAN E204 PITCH 4 LIGHTING PLAN E205 PLAYER PARKING LIGHTING AND POWER E206 SITE NW LIGHTING RELOCATIONS E207 KEYPLANS E211 LEVEL 1 POWER PLAN SOUTH E212 LEVEL 1 POWER PLAN NORTH E213 LEVEL 1 POWER PLAN EAST E221 LEVEL 2 POWER PLAN SOUTH E222 LEVEL 2 POWER PLAN NORTH E311 LEVEL 1 LIGHTING PLAN SOUTH E312 LEVEL 1 LIGHTING PLAN NORTH E313 LEVEL 1 LIGHTING PLAN EAST E321 LEVEL 2 LIGHTING PLAN SOUTH E322 LEVEL 2 LIGHTING PLAN NORTH E411 LEVEL 1 MECHANICAL PLAN SOUTH E412 LEVEL 1 MECHANICAL PLAN NORTH E413 LEVEL 1 MECHANICAL PLAN EAST E421 LEVEL 2 MECHANICAL PLAN SOUTH E422 LEVEL 2 MECHANICAL PLAN NORTH E452 ROOF MECHANICAL PLAN NORTH E501 LEVEL 1 ENLARGED POWER PLANS E502 LEVEL 2 ENLARGED POWER PLANS E503 ELECTRICAL DETAILS REV DESCRIPTION DATE PROJECT DESCRIPTON: • EXISTING 5-STORY, 300KSF BUILDING • BUILDNG IS CURRENTLY UNNOCUPIED. • TENNAT IS MOVING INTO 31KSF ON LEVEL 1 AND 19KSF ON LEVEL 2. • ADDITIONAL SPORTS FIELDS AND ASSOCIATED LIGHTING • REMAINDER OF BUILDING TO REMAIN UNOCCUPIED. • REFER TO BUILDING LOAD CALCULATION SUMMARY ON THIS SHEET. © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:35 PM E101 ONE LINE DIAGRAM 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET REV DESCRIPTION DATE © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:35 PM E102 ONE LINE DIAGRAM 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET REV DESCRIPTION DATE © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:36 PM E103 LIGHTING FIXTURE SCHEDULE 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET REV DESCRIPTION DATE © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:37 PM E104 ENERGY CODE FORMS 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET REV DESCRIPTION DATE EXISTING LONGACRES BUILDING 25-20 EXISTING PARKING TO REMAINEXISTING PARKING TO REMAIN FIELD 1 NATURAL GRASS 116 YD x 75 YD FIELD 2 NATURAL GRASS 116 YD x 75 YD FIELD 3 SYNTHETIC TURF 116 YD x 75 YD OAKESDALE AVE CONDITIONING / UTILITY SPACE NATURAL GRASS EXISTING PLANTING TO REMAIN, TYP. 10' CHAIN LINK FENCE W/ WRAP AT PENALTY BOX WITH 15' BALL CONTROL NETTING ABOVE AT GOAL BOX, TYP. EXISTING PLANTING AND TREES TO REMAIN, TYP. EXISTING WALKWAY CANOPY TO REMAIN 4' BALL CONTROL CHAIN LINK FENCE, TYP. NEW PLANTING AREAS LANDSCAPE RESTORATION 20' DOUBLE SWING GATE PROPERTY LINE PROPERTY LINE ZONING = CO OVERALL SITE SF = 645,165 SF 14.81 AC EXISTING BUILDING = 61,295 SF (5 FLOORS) OVERALL = 306,475 SF ALLOWABLE = UNLIMITED NEW MAINTENANCE BUILDING = 4,000 SF LOT COVERAGE = 5.0% TOTAL FOOTPRINT = 65,295 SF BUILDING HEIGHT = 93'-8" MAINTENANCE = 15'-0" ALLOWABLE = 250' PER CO ZONING PARKING STALLS = 60 PARKING (LEASED SECURE PARKING) PLAYER PARKING AREA = 17,487 SF LEGEND: EXISTING DETENTION POND EXISTING DETENTION POND SETBACK LINE EXISTING WETLAND WETLAND BUFFER SHOWN DASHEDLOT 8 TRACT B LOT 14 TRACT A LOT 12 LOT 13 LOT 21 LOT 11 OVERALL = 5.0% 65,295SF/1,320,419SF LOT COVERAGE BREAKDOWN: TRACT B = 0.0% LOT 11 = 0.0% LOT 12 = 0.0% LOT 13 = 2.2% 4,000SF/183,925SF LOT 14 = 0.0% LOT 21 = 0.0% LOT 22 = 33.5% 61,295SF/183,925SF NOTE: TRASH HANDLING FACILITIES FOR THE OVERALL DEVELOPMENT ARE ADEQUATE TO SUPPORT ALL TRASH, RECYCLING, AND OTHER MATERIAL GENERATED THROUGH THE USE OF THE PLAYING FIELDS 150' - 0"150' - 0"FIELD 4 SYNTHETIC TURF 116 YD x 75 YD 10' WIDE DOUBLE SWING GATES, TYP. U.N.O. LANDSCAPE RESTORATION FIELD LIGHTING, TYP. 10' CHAIN LINK FENCE W/ WRAP AROUND NEW CONCRETE SLAB 10' CHAIN LINK FENCE W/ PRIVACY WRAP, TYP. RE: LANDSCAPE DRAWINGS NEW PEDESTRIAN PATHWAY EXISTING DETENTION POND 4' WIDE SINGLE SWING GATE 8' WIDE DOUBLE SWING GATE REFER TO CIVIL CONSTRUCTION PERMIT FOR SCOPE OF WORK. CUP APPLICATION: LUA22-00357 CIVIL PERMIT #: PR22-000301 MAINTENANCE BUILDING. BUILDING PERMITTED UNDER SEPARATE PERMIT MAINTENANCE BUILDING OPTION #1 81' - 4"48' - 0"60 SECURE PARKING SPACESNEW FENCING & GATES FOR SECURE PARKING AREA NEW EXTERIOR PATIO AND VIEWING PLATFORM ABOVE 2 (20') WIDE DOUBLE SWING GATES NEW CONCRETE VIEWING AREA MAINTENANCE BUILDING OPTION #2 81' - 4"48' - 0"A B C D E F G H J K L 123456 E201 1 MAIN ELECTRICAL ROOM NEW UNDERGROUND DUCT BANK CONDUITS (SCH40 PVC): -(2) 4"C NEW FEEDER FOR NEW PANEL M4-1 -(1) 4"C FIRE ALARM -(2) 4"C TELECOMM, CONTROLS, SECURITY, LOW VOLTAGE -(1) 2"C EMERGENCY POWER -(2) 4"C SPARE POWER ROUTE NEW CONDUITS TO MAINTENANCE BUILDING. COORDINATE WITH SITE & CIVIL. E202 1 LEVEL 1 WEST ELECTRICAL ROOM (2) 3.5" SPARE CONDUITS, UNDERGROUND, FROM UNIT-SUB SECTION A TO L1 WEST ELECTRICAL ROOM. ROUTE NEW FEEDER CONDUCTORS WITHIN UG CONDUIT. STUB-UP POINT WITHIN UNIT-SUB SECTION A. STUB-UP POINT WITHIN L1 WEST ELEC ROOM. ROUTE NEW CONDUITS SURFACE ALONG CEILING, FROM L1 WEST ELEC ROOM TO EXTERIOR. ROUTE CONDUITS DOWN ALONG COLUMN OR OTHER SITE INFRASTRUCTURE. STUB UP INTO MAINTANENCE BUILDING NEW 480V PANEL. COORDINATE FINAL WALL SPACE WITH ALL TRADES AND EQUIPMENT. E204 1 E203 101 14 E205 1 01 14 01 14 01 14 E206 1 NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:52 PM E200 SITE POWER PLAN 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1" = 60'-0"1 SITE POWER PLAN KEYNOTES 01 14 PROVIDE (1) 2" CONDUIT FROM IRRIGATION CONTROLLER INTO EXTERIOR PLANTER AREA. COORDINATE WITH IRRIGATION DESIGN. REV DESCRIPTION DATE J J J J J J WASH RACK EQUIPMENT G G G G G WP-G WP-G G G G G G G WP-G WP-G G G MANUAL OVERHEAD DOOR MANUAL OVERHEAD DOOR MANUAL OVERHEAD DOOR WP-G EWH 2002 WCP 2004 HT 01 HT 02 SEF 03 SEF 02 SEF 01 EUH 01 EUH 03 EUH 02 M4.1-38,40,42 B4.1-1 B4.1-5 B4.1-3 B4.1-7 M4.1-24,26,28 B4.1-32,34,36 M4.1-30 CU 01 B4.1-9,11 #10 AC 01 B4.1-13,15,17 B4.1-13 B4.1-13 B4.1-13 B4.1-15 B4.1-15 B4.1-13 B4.1-17 B4.1-17 B4.1-17 B4.1-17 B4.1-15 B4.1-15 B4.1-19 B4.1-19 B4.1-19 B4.1-19 B4.1-19 B4.1-15 B4.1-19 B4.1-28 MODs MOD 03 28 MOD 0128 MOD 2 28 M4.1-22 M4.1-22 B4.1-30 IRRIG PUMP B4.1-32 EQ LIFT M4.1-16,18,20 VERIFY SPEC VERIFY SPEC IDF 185 RESTROOM 184 PESTICIDE 183 STORAGE 182 EQUIPMENT 181 MANUAL OVERHEAD DOOR B4.1-38 CR POWER GATES AND MB WATER METER B4.1-40 TPV 01 40 TPV 01 40 TPV 01 40 TPV 01 40 TPV 01 40 TPVs (ETPs) NEMA L6-20R (208V/1P/20A), #12 CONDUCTORS NEMA L6-30R (208V/1P/30A), #10 CONDUCTORS NEMA L5-20R (120V/1P/20A), #12 CONDUCTORS NEMA L5-30R (120V/1P/30A), #10 CONDUCTORS NEMA L21-20R (208V/3P/20A) NEMA L21-30R (208V/3P/30A) NEMA L15-60P (208V/3PH/60A), 4P-5W CARD READER ROUGH-IN G POWER SYMBOLS LEGEND: E F A B C D J DUPLEX RECEPTACLE - STANDARD DUPLEX RECEPTACLE - ABOVE COUNTER +43" UON DUPLEX RECEPTACLE - DEDICATED "WA1-5a" = FULLY CONTROLLED/SWITCHED VIA RELAY. "WA1-5,5a" = SPLIT-WIRED, HALF CONTROLLED/SWITCHED. PULL ADDITIONAL SWITCHED HOT CONDUCTOR VIA IN-CEILING RELAY. G = GFCI RECEPTACLE QUAD RECEPTACLE - STANDARD QUAD RECEPTACLE - ABOVE COUNTER +43" UON QUAD RECEPTACLE - DEDICATED J-BOX - SYMBOLIC, NOT ACTUAL LOCATION DATA SINGLE-GANG ROUGH-IN DUPLEX RECEPTACLE - CEILING MOUNTED DUPLEX RECEPTACLE - TVTV QUAD RECEPTACLE - CEILING MOUNTED DATA SINGLE-GANG ROUGH-IN, CEILING MOUNTED QUAD RECEPTACLE - SWITCHED/CONTROLLED DUPLEX RECEPTACLE - SWITCHED/CONTROLLED A AV SINGLE-GANG ROUGH-IN, TV DISCONNECT NON-FUSED DISCONNECT FUSED EQUIPMENT CONNECTION HOME RUN, TICK MARKS INDICATE QTY OF CONDUCTORS. LONG DASH=N, SHORT DASH=PH, DOT=GND CR CC 42 B4.1-2,4,6 6 6 B4.1-8 SECURITYACCESS 02 77 GND BAR IRRIGATION CTRLS CTRLS FA M4-1B4-1PITCH LCP TB4-1 45kVA B4.1-20 B4.1-24 B4.1-26 02 77 XG5.4-1 #4 GENERAL NOTES POWER: 1. NOT ALL KEYNOTES ARE USED ON THIS SHEET. 2. HOME RUN AND J-BOX LOCATIONS ARE SHOWN AS DIAGRAMTIC. COORDINATE FINAL LOCATIONS TO BEST HIDE ABOVE ACCESSIBLE CEILINGS. MAINTAIN ACCESSIBILITY AROUND DUCT AND ANY OTHER CEILING ELEMENTS. 3. NEW OUTLETS THAT SHARE A WALL, BUT ARE FACING OPPOSITE SIDES TO BE IN SEPARATE STUD CAVITIES. 4. ALL HOME-RUNS ARE #10 AWG UNLESS OTHERWISE NOTED. 5. COORDINATE WITH AV, TELECOMM AND SECURITY DESIGN DRAWINGS FOR CABLE TRAY, LOW VOLTAGE PATHWAY AND ADDITIONAL DEVICE ROUGH-IN REQUIREMENTS. 6. DEVICES SHOWN SHALL BE MOUNTED AT +18" AFF UNLESS OTHERWISE NOTED. COORDINATE ALL MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. 7. PROVIDE SPACE IN HOMERUNS FOR 25% FUTURE GROWTH. 8. COORDINATE COVER PLATE & SWITCH COLORS WITH ARCHITECT PRIOR TO ORDERING. 9. GENERAL USE HOUSEKEEPING RECEPTACLES SHALL BE SPACED AT APPROXIMATELY 40 FEET FOR CLEANING AND MAINTANANCE. MAX 8 RECEPTACLES PER CIRCUIT. 10. HOMERUNS SHOWN WITH SHARED NEUTRAL SHALL HAVE A MINIMUM OF #10AWG NEUTRAL. PROVIDE HANDLE TIES ACROSS ALL CIRCUITS WITH SHARED NEUTRALS PER NEC. 11. TABLE TOP RECEPTACLES BY OTHERS (FURNITURE VENDOR) VIA PLUG-STRIP PLUG-IN TO FLOOR POWER. ASSUME (6) DUPLEX RECEPTACLES ON MEDIUM AND LARGE TABLE TOPS; (4) DUPLEX RECEPTACLES ON SMALL TABLE TOPS. 12. WHERE POSSIBLE VERTICALLY ALIGN RECEPTACLES, LIGHTING CONTROLS, FIRE ALARM STROBES/HORNS AND THERMOSTATS THROUGHOUT. 13. POKE-THRU AND FLOORBOX LOCATIONS HAVE BEEN PLACED FOR INTENT ONLY. FINAL EXACT LOCATIONS TO BE COORDINATED WITH ARCHITECT AND OTHER CEILING SYSTEMS BELOW AND FURNITURE SYSTEMS. MDF AND IDF ROOMS: 1. IN ADDITION TO GROUNDING SHOWN ON EXISTING GROUNDING RISER, PROVIDE GROUND CONDUCTORS AND TERMINATIONS, WITH INSULATED #6 AWG CONDUCTOR, FROM GROUND BAR TO THE FOLLOWING CABLE ROOM COMPONENTS (WHERE EXISTING TERMINATIONS ARE NOT PROVIDED): - RAISED FLOOR PEDESTALS AND SYSTEM - TELECOM BACKBOARDS - CABLE SHEATHES - SPLICE CASES - UPS GROUND BUS - WITHIN CABLE TRAY BONDED EVERY 10' - FROM CABLE TRAY TO EACH RACK NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:54 PM E201 MAINTENANCE BUILDING POWER AND MECH PLAN 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1/8" = 1'-0"1 MAINTENANCE BUILDING POWER AND MECH PLAN 1/4" = 1'-0"2 MAINTENANCE BUILDING IDF ROOM 1/4" = 1'-0"3 MAINTENANCE BUILDING ELECTRICAL PANELS KEYNOTES 02 77 GROUND TO NEW GROUNDING PILE REBAR AND GROUNDING GRID VIA #3/0 COPPER. REV DESCRIPTION DATE SSSOS OS S S PS PS SS S S OS OS OSOS J RC1 RC1 RC1 RC1 RC1 RC1 J L8US PD1W PD1WPD1W E1 E1 E1 E1 E2 E2 L8US L8US L8US L8US L8US L8US L8US L8US L8US L8US L8US L8US L8US L4U L4U L4U L4U L4U L4U X3X3 X3 X3 OS ALL FIXTURES CIRCUITED TO M4.1-8 UNLESS OTHERWISE NOTED. M4.1-8 XB3-13 #4 EQUIPMENT 181 IDF 185 RESTROOM 184 PESTICIDE 183 STORAGE 182 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 XB3-13 GENERAL NOTES LIGHTING: 1. NOT ALL KEYNOTES ARE USED ON THIS SHEET. 2. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND FINAL DIMENSIONING. 3. WHERE POSSIBLE VERTICALLY ALIGN RECEPTACLES, LIGHTING CONTROLS, FIRE ALARM STROBES/HORNS AND THERMOSTATS THROUGHOUT. 4. PER WSEC C405.2.2.3, PROVIDE FIXTURES AND CONTROLS SUCH THAT THE PRIMARY DAYLIGHT ZONE IS CONTROLLED SEPARATELY FROM THE SECONDARY ZONE. 5. COORDINATE COVER PLATE & SWITCH COLORS WITH ARCHITECT PRIOR TO ORDERING. 6. PROVIDE CUSTOM ENGRAVED SWITCH PLATES FOR TEAM ROOMS, SMALL, MEDIUM AND LARGE CONFERENCE ROOMS AS REQUIRED. 7. FIXTURES DESIGNATED WITH CIRCUITRY LABELLED "X1", "X3", ETC OR 'EM', ARE FED FROM A GENERATOR BACKED CIRCUIT AND WILL PROVIDE EGRESS LIGHTING WHEN UTILITY POWER IS LOST. 8. HALLWAYS AND OPEN OFFICE AREAS SHALL BE TIMECLOCK CONTROLLED WITH AUTOMATIC LOW VOLTAGE OVERRIDE AND OCCUPANCY SENSOR CONTROL OF LIGHTING DURING AFTERHOURS. EACH OVERRIDE SWITCH PER 5,000 SQ-FT MAX. 9. PROVIDE UL924 EMERGENCY BYPASS MODULE FOR ALL EMERGENCY FIXTURES DESIGNATED WITH SWITCH LEG. 10. IN CONFERENCE ROOMS: LOCATE CEILING-MOUNT OCCUPANCY SENSORS IN CORNER ALONG SAME WALL AS DOOR SO THAT LIGHTING IS NOT TRIGGERED FROM HALLWAY. 11. E.C. TO CONFIRM LED DRIVERS TO BE COMPATIBLE AND OPERATE "FLICKER-FREE" WITH DIMMING SYSTEM SELECTED. CONFIRMATION SHALL BE ACCEPTED BY EITHER MANUFACTURER PROVIDED COMPATIBILITY MATRIX, MOCK-UP OR SELECTING DRIVER AND CONTROL COMPONENTS MADE BY SAME MANUFACTURER. 12. E.C. TO CONFIRM VOLTAGES AND DIMMING PROTOCOLS ON EACH LIGHT FIXTURE TYPE AND PROVIDE ASSOCIATED LIGHTING CONTROLS PARTS AND PIECES AS NECESSARY. 13. PROVIDE LIGHTING CONTROL SYSTEM COMMISSIONING PER WSEC C408.3. 14. REFER TO ARCHITECTURAL DRAWINGS FOR FINAL EXIT SIGN LOCATIONS AND QUANTITIES. EXIT SIGNS ARE TO BE SERVED BY UNSWITCHED EMERGECNY CIRCUIT. 15. PROGRAM ALL OCCUPANCY SENSORS TO BE AUTO-ON TO 50% PER WSEC C405.2.1.1. 16. ALL DEVICE LOCATIONS SHOWN ON LIGHTING AND POWER PLANS ARE DIAGRAMMATICAL, INSTALL DEVICES IN ADJACENT SPACE ABOVE NON-EXPOSED ACCESSIBLE CEILINGS AS NEEDED. 17. UNDER-SHELF OR UNDER-CABINET TASK LIGHTING, SHALL BE AUTOMATICALLY SHUT OFF WHENEVER THAT SPACE IS UNOCCUPIED AND SHALL BE CONTROLLED BY A WALL- MOUNTED CONTROL DEVICE PROVIDED THAT THE CONTROL DEVICE IS READILY ACCESSIBLE PER WSEC C405.2.5. 18. EXTERIOR LIGHTS CONTROL VIA PHOTOCELL AND TIME CLOCK. 19. PROVIDE DRY CONTACT OUTPUT FROM LIGHTING CONTROL SYSTEM OCCUPANCY SENSOR AND WIRING TO VAV UNIT(S) SERVING THE FOLLOWING ENCLOSED SPACES: 1. FOCUS ROOMS 2. PROJECT/TEAM ROOMS 3. CONFERENCE ROOMS (SMALL, MEDIUM AND LARGE) REFER TO MECHANICAL CONTROLS DRAWING FOR UNITS CONTROLLED BY OCCUPANCY SENSOR SIGNAL. COORDINATE CONTROL SIGNAL AND WIRING REQUIREMENTS WITH MECHANICAL PRIOR TO ROUGH-IN SINGLE BUTTON DIMMER SWITCH 1-ZONE CONTROL MULTI-BUTTON DIMMER FOR NEIGHBORHOODS, TEAM AND CONFERENCE ROOMS. PROVIDE DIM CONTROL PER ZONE OR VIA SCENE SELECTION DEPENDING ON SPACE TYPE. STANDARD CEILING MOUNTED OCCUPANCY SENSOR DUAL TECH CEILING MOUNTED OCC SENSOR MULTI-ZONE PHOTOSENSOR ON/OFF SWITCHED ROOM CONTROLLER 0-10V DIMMING ROOM CONTROLLER, NUMBER DENOTES QUANTITY OF RELAYS. UNIVERSAL PHASE DIMMING ROOM CONTROLLER WITH 2 RELAYS LIGHTING CONTROL HEAD END WITH ENCLOSURE LOW VOLTAGE OVERRIDE SWITCH FOR HALLWAY LIGHTING 0-10V DIMMER/OCCUPANCY SENSOR SWITCH (FOCUS, PHONE & CODE ROOMS). PROGRAM SWITCHES TO BE AUTO-ON TO 50% VERSUS VACANCY MODE. STANDARD OCC SENSOR ON/OFF SWITCH. 6-ZONE TOUCHSCREEN LIGHTING CONTROL STATION WITH RS-232 INTERFACE FOR AV SYSTEM. 5 BUTTON SCENE CONTROL SWITCH. LIGHTING SYMBOLS RC3 S RC1 RCU DLV SDLVabc PS LCH SLV1 SDa SOS OS1 OS LCS SCNORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:20:55 PM E202 MAINTENANCE BUILDING LIGHTING PLAN 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1/8" = 1'-0"1 MAINTENANCE BUILDING LIGHTING PLAN REV DESCRIPTION DATE J J FIELD 1 NATURAL GRASS 116 YD x 75 YD FIELD 2 NATURAL GRASS 116 YD x 75 YD FIELD 3 SYNTHETIC TURF 116 YD x 75 YD CONDITIONING / UTILITY SPACE NATURAL GRASS 10' CHAIN LINK FENCE W/ WRAP AT PENALTY BOX WITH 15' BALL CONTROL NETTING ABOVE AT GOAL BOX, TYP. 4' BALL CONTROL CHAIN LINK FENCE, TYP. LOT 12 LOT 13 LOT 11 10' WIDE DOUBLE SWING GATES, TYP. U.N.O. FIELD LIGHTING, TYP. REFER TO CIVIL CONSTRUCTION PERMIT FOR SCOPE OF WORK. CUP APPLICATION: LUA22-00357 CIVIL PERMIT #: PR22-000301 NEW EXTERIOR PATIO AND VIEWING PLATFORM ABOVE 122.53456 S8 S6S5 S7 PITCH 3 PITCH 2 PITCH 1 CONDUCTORS AND EGC UPSIZED FOR VOLTAGE DROP. #1/0 + #4 EGC #1/0 + #4 EGC #1/0 + #4 EGC M4.1-1,3,5 #1/0 + #4 EGC 3.02%VD 3.58%VD 3.96%VD 4.15%VD SPARE CONDUIT GENERAL NOTES PITCH LIGHTING: 1. NOT ALL KEYNOTES ARE USED ON THIS SHEET. 2. COORDINATE WITH FIELD LIGHTING APPROVED MANUFACTURER, SUBMITTALS AND SHOP DRAWINGS FOR POINT OF ANY ADDITIONAL REQUIREMENTS. 3. EACH LIGHT POLE INDICATED WITH AN "S#", PROVIDE (1) 480V-3PH CIRCUIT UNDERGROUND FROM NEW MAINTENANCE BUILDING POWER PANEL M4-1 TO SINGLE POINT OF CONNECTION WITHIN MANUFACTURER PROVIDED POLE MOUNTED POWER ENCLOSURE. EACH POLE POWER ENCLOSURE HAS VENDOR PROVIDED INTEGRATED SUBPANEL RELAYS, DRIVERS AND CORDS THAT FEED THE LIGHTS AT TOP OF THE POLE. POLE LIGHTS COMMUNICATE VIA RADIO PROTOCOL AND ARE CONTROLLED VIA CONTROL HEAD END IN MAINTENANCE BUILDING. 4. E.C. TO COORDINATE UNDERGROUND CONDUIT ROUTING WITH G.C. AND CIVIL. AT TIME OF SIGNED OFF UNDERGROUND MODELING, PROVIDE E.E. WITH CONDUCTOR DISTANCE FOR EACH POLE LIGHT SO E.E. CAN DESIGN APPROPRIATE CONDUCTOR SIZE FOR VOLTAGE DROP CONSIDERATIONS NOT- TO-EXCEED 5% VOLTAGE DROP AT THE LIGHT. 5. EACH LIGHT POLE INCLUDES MANUFACTURER DESIGNED AND INTEGRATED UL LISTED CLASS II LIGHTNING PROTECTION GROUNDING SYSTEM VIA 2/0 AWG GROUNDING ELECTRODE CONDUCTOR THAT TIES INTO THE VENDOR POLE BASE REBAR. NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:21:03 PM E203 PITCH 3 LIGHTING PLAN 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1" = 30'-0"1 PITCH 3 LIGHTING PLAN REV DESCRIPTION DATE 20' DOUBLE SWING GATE LOT 14 FIELD 4 SYNTHETIC TURF 116 YD x 75 YD LANDSCAPE RESTORATION 10' CHAIN LINK FENCE W/ WRAP AROUND NEW CONCRETE SLAB MAINTENANCE BUILDING. BUILDING PERMITTED UNDER SEPARATE PERMIT MAINTENANCE BUILDING OPTION #1 81' - 4"48' - 0"MAINTENANCE BUILDING OPTION #2 81' - 4"48' - 0"S2 S3 S1 S4 M4.1-7,9,11 #1/0 + #4 EGC PITCH 4 CONDUCTORS AND EGC UPSIZED FOR VOLTAGE DROP. #1/0 + #4 EGC #1/0 + #4 EGC #1/0 + #4 EGC 2.56%VD 3.14%VD3.51%VD 3.70%VD SPARE CONDUIT GENERAL NOTES PITCH LIGHTING: 1. NOT ALL KEYNOTES ARE USED ON THIS SHEET. 2. COORDINATE WITH FIELD LIGHTING APPROVED MANUFACTURER, SUBMITTALS AND SHOP DRAWINGS FOR POINT OF ANY ADDITIONAL REQUIREMENTS. 3. EACH LIGHT POLE INDICATED WITH AN "S#", PROVIDE (1) 480V-3PH CIRCUIT UNDERGROUND FROM NEW MAINTENANCE BUILDING POWER PANEL M4-1 TO SINGLE POINT OF CONNECTION WITHIN MANUFACTURER PROVIDED POLE MOUNTED POWER ENCLOSURE. EACH POLE POWER ENCLOSURE HAS VENDOR PROVIDED INTEGRATED SUBPANEL RELAYS, DRIVERS AND CORDS THAT FEED THE LIGHTS AT TOP OF THE POLE. POLE LIGHTS COMMUNICATE VIA RADIO PROTOCOL AND ARE CONTROLLED VIA CONTROL HEAD END IN MAINTENANCE BUILDING. 4. E.C. TO COORDINATE UNDERGROUND CONDUIT ROUTING WITH G.C. AND CIVIL. AT TIME OF SIGNED OFF UNDERGROUND MODELING, PROVIDE E.E. WITH CONDUCTOR DISTANCE FOR EACH POLE LIGHT SO E.E. CAN DESIGN APPROPRIATE CONDUCTOR SIZE FOR VOLTAGE DROP CONSIDERATIONS NOT- TO-EXCEED 5% VOLTAGE DROP AT THE LIGHT. 5. EACH LIGHT POLE INCLUDES MANUFACTURER DESIGNED AND INTEGRATED UL LISTED CLASS II LIGHTNING PROTECTION GROUNDING SYSTEM VIA 2/0 AWG GROUNDING ELECTRODE CONDUCTOR THAT TIES INTO THE VENDOR POLE BASE REBAR. NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:21:05 PM E204 PITCH 4 LIGHTING PLAN 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1" = 30'-0"1 PITCH 4 LIGHTING PLAN REV DESCRIPTION DATE J J J J NEW PLANTING AREAS 60 SECURE PARKING SPACES A B C COORDINATE WITH ARCH AND SITE/CIVIL ON LOCATION OF CARD READER FOR MOTORIZED GATE PLAYER PARKING CHAIN LINK FENCE BY OTHERS CR POST GATE MOTOR B4.1-34 LOW VOLTAGE CONDUIT (1)1"C (LOW VOLTAGE) TO ACCESS CONTROL HEAD END. COORDINATE WITH SECURITY DRAWINGS.HH HH (1)1"C (LOW VOLTAGE) TO ACCESS CONTROL HEAD END. COORDINATE WITH SECURITY DRAWINGS. B4.1-36 GATE MOTOR VERIFY SPEC VERIFY SPEC CR POST LOW VOLTAGE CONDUIT LOW VOLTAGE CONDUIT COORDINATE WITH ARCH AND SITE/CIVIL ON LOCATION OF CARD READER FOR MOTORIZED GATE TYP QTY (3): EXISTING PARKING LIGHT POLE TO BE RELOCATED. (TYP) QTY 3: NEW LOCATIONS OF RELOCATED EXISTING LIGHTS. RE-CONNECT TO EXISTING CIRCUIT AND CONTROLS. COORDINATE WITH SITE AND CIVIL AS NEEDED. TYP QTY (3): EXISTING PARKING LIGHT POLE TO BE RELOCATED. TYP QTY (3): EXISTING PARKING LIGHT POLE TO BE RELOCATED. (TYP) QTY 3: NEW LOCATIONS OF RELOCATED EXISTING LIGHTS. RE-CONNECT TO EXISTING CIRCUIT AND CONTROLS. COORDINATE WITH SITE AND CIVIL AS NEEDED. (TYP) QTY 3: NEW LOCATIONS OF RELOCATED EXISTING LIGHTS. RE-CONNECT TO EXISTING CIRCUIT AND CONTROLS. COORDINATE WITH SITE AND CIVIL AS NEEDED. NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:21:07 PM E205 PLAYER PARKING LIGHTING AND POWER 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET 1/16" = 1'-0"1 PARKING AREA LIGHTING AND POWER REV DESCRIPTION DATE FIELD 1 NATURAL GRASS 116 YD x 75 YD CONDITIONING / UTILITY SPACE NATURAL GRASS PROPERTY LINE 10' CHAIN LINK FENCE W/ PRIVACY WRAP, TYP. RE: LANDSCAPE DRAWINGS TYP QTY (2): EXISTING FIELD LIGHT POLE TO BE RELOCATED. TYP QTY (2): EXISTING FIELD LIGHT POLE TO BE RELOCATED. (TYP) QTY 2: NEW LOCATIONS OF RELOCATED EXISTING LIGHTS. RE-CONNECT TO EXISTING CIRCUIT AND CONTROLS. COORDINATE WITH SITE AND CIVIL AS NEEDED. (TYP) QTY 2: NEW LOCATIONS OF RELOCATED EXISTING LIGHTS. RE-CONNECT TO EXISTING CIRCUIT AND CONTROLS. COORDINATE WITH SITE AND CIVIL AS NEEDED. EXISTING WALKWAYS TO BE DEMOED SHOWN FOR REFERENCE ONLY. SEE ARCHITECTURAL SITE DEMO PLANS. TYP QTY (2): DEMO EXISTING FIELD LIGHT POLE. TYP QTY (2): DEMO EXISTING FIELD LIGHT POLE. TYP QTY (5): DEMO EXISTING LIGHT BOLLARDS. TYP QTY (1) EXISTING LIGHT BOLLARD TO REMAIN. NORTH © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 4/21/2023 12:21:09 PM E206 SITE NW LIGHTING RELOCATIONS 22025 SEATTLE SOUNDERS FC HQ & TRAINING APRIL 24, 2023 Author 1901 OAKESDALE AVE SW RENTON, WA 98057 Checker PERMIT SET REV DESCRIPTION DATE 1/16" = 1'-0"1 SITE NORTH WEST LIGHTING RELOCATIONS