Loading...
HomeMy WebLinkAboutEX16_P_Drainage PlanWATER MAIN EXTENSION WATER METER (TYP) SEWER CLEANOUT (TYP) SEE DETAIL ON C3.4 SEWER STUB (TYP) SEWER MAIN EXTENSION 39540 0 400 400 400405 405 405 405 405 405410 410 410415415392 393394396396 397397 398 398 39 8 398399399 399 39 9 401 401 401 401 402 402 402 402 403 403 403 403404 404 404 404406 406 406 406407 407407 407 408 408 408 408409 409 409411 411 411 411 411412 412 412 413 413 413 413414 414 414 403400 405 3 9 8 399 401 402 403 404 406 407 408 409 405 410 404 406 407 408 409 411 412 413 414 400398398 399 401 402 403 39 8 39 9 400405398399401402403404406 407 408 409 41 0 41 1 41 2 41 3 414 414408 405 410405 40 5 405 405405 410 41 0 400 405410 4 0 1 402 40340440640740 8 409 411 405 410 10+0011+0012+0012+7019+68 20+00 21+00 22+00 23+0024+0024+38STA:23+35.00, 3.50 L END WALL STA:22+83.92, 4.12' L AIR & VACUUM RELEASE ASSEMBLY SEE DETAIL ON C3.4 STA:20+05.67, 15.60' R SSMH #2 SEE DETAIL ON C3.4 STA:20+02.00, 4.89' R TEE STA:22+65.18, 11.39' R SSMH #3 SEE DETAIL ON C3.4 STA:23+10.16, 25.28' R FIRE HYDRANT SEE DETAIL ON C3.4 STA:21+46.67, 5.03' R WATER SERVICE (TYP) SEE DETAIL ON C3.4 STA:21+36.67, 43.52' R SANITARY SEWER STUB CONNECTION SEE DETAIL ON C3.4 STA:22+78.47, 43.21' R SANITARY SEWER STUB CONNECTION SEE DETAIL ON C3.4 STA:23+06.33, 16.51' L SANITARY SEWER STUB CONNECTION SEE DETAIL ON C3.4 STA:20+04.19, 1.89' R BLOW-OFF ASSEMBLY SEE DETAIL ON C3.4 STA:19+99.85, 138.39' R CONNECT TO EX MAIN END LINE CAP SEE DETAIL ON C3.4 STA:20+07.74, 239.10' R SEE DETAIL ON C5.0 SANSANSANSANSANSANSANSANSANSANSANSANSANSAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN SAN SAN SAN SDSD SD SD SD SD SD SD SD SD SD SD SDSDSDSD SD SD SDSD SD SD SD SD SD SD SDSDSDSDSDSD SD SD SD SDWWWWWWW W WWWWWWWWWSANSANSANSANSANSANSANSANSANSANSANSAN SSSSSSW W W W W W W W W W W W W W W W W SSS SSSSANSANSANSANSANSANSANSANSANSANSANSANSANSAN SDSDSDSDSD SD SD SD SD SD SD SD SD SD SD SD COMCOMCOMCOMCOMCOMCOMXXX(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)(P)TRTRTRPSDS D S D S D S D STA:22+42.94, 5.13' R WATER SERVICE 400 401 402 403 400 401 402 403 404399 410 128th A V E S E SE PETROVITSKY RDSE 176th STCONNECT ALL DOWNSPOUTS TO STORM DRAINAGE SYSTEM (TYP) SEE DETAIL 3/C3.2 SDCO RIM TO GRADE SEE DETAIL 2/C3.2 STORM FILTER #2 RIM 398.00 IE 396.00 SEE DETAIL 2/C3.3 42 LF 6" PVC SD @ 0.5% MIN STORM DETENTION VAULT SEE SHEET C3.3 FOR DETAILS 40459 LF 8" PVC SD @ 0.5% 42 LF 6" PVC SD @ 0.5% MIN SDCO RIM TO GRADE SEE DETAIL 2/C3.2 CATCH BASIN TYPE 1 RIM 399.50 IE 397.50 SEE DETAIL 4/C3.2 111 LF 8" PVC SD @ 1.35% CATCH BASIN TYPE 1 RIM 403.00 IE 401.00 SEE DETAIL 4/C3.2STORM FILTER #1 RIM 398.50 IE 396.50 SEE DETAIL 2/C3.3 16 LF 8" PVC SD @ 0.5% 17 LF 8" PVC SD @ 0.5% CATCH BASIN TYPE 2 W/ RELEASE STRUCTURE RIM 399.00 IE (OUT) 390.00 SEE DETAIL 5/C3.2 75 LF 12" PVC SD @ 0.5% RIP RAP OUTFALL TO KING COUNTY PUBLIC PARK WETLAND IE 389.50 SEE DETAIL 1, THIS SHEET SDCO RIM TO GRADE SEE DETAIL 2/C3.2 11 LF 6" PVC SD @ 0.5% MIN IE (OUT) 390.00 IE (OUT) 390.00 IE 396.40 IE 395.70 14 LF 6" PVC SD @ 0.5% MIN 59 LF 8" PVC SD @ 6.1% MIN WETLAND BUFFER FROM KING COUNTY PUBLIC PARK PER GIS 5'STORM ESMT FOR LOT 4 CIVIL & STRUCTURAL ENGINEERING | LAND SURVEYING | PLANNINGPROJECT MANAGEMENT | FEASIBILITY | PERMIT EXPEDITINGCORPORATE OFFICE5920 100th St SW, Ste #25Lakewood, WA 98499phone: 253-984-2900beylerconsulting.comSHEET OF JOB NUMBERNO. DESCRIPTION INIT DATEDRAWN BY:CHECKED BY:SCALE:HORZ:VERT:DATE:BEYLERCONSULTINGPlan. Design. ManageCAD FILE: X:\Projects\_2018 Projects\18.00392.00 Castro - SE Petrovitsky Rd\4Civil Engineering\Engineering Drawings\18.00392 DRAINAGE & UTILITY.dwg PLOT DATE/TIME: 3/9/2023 6:33 PM18.0039212727 SE PETROVITSKY RDSITE IMPROVEMENTCITY OF RENTONWASHINGTON17 SECTION 23, TOWNSHIP 28 N, RANGE 05 E C3.1STORM DRAINAGE & UTILITY PLAN5 Know what's below. before you dig.Call R 20 10 0 20 SCALE: 1" = 20' BSBL BUILDING SETBACK LINE CB CATCH BASIN CO CLEAN OUT CONC CONCRETE DI DUCTILE IRON FH FIRE HYDRANT HP HIGH POINT LP LOW POINT MH MANHOLE PVC POLYVINYLCHLORIDE REQ'D REQUIRED RPBA REDUCED PRESSURE BACKFLOW PREVENTOR SD STORM DRAIN SDCO STORM DRAIN CLEAN OUT SDMH STORM DRAIN MANHOLE SS SANITARY SEWER SSCO SANITARY SEWER CLEAN OUT SSFM SANITARY SEWER FORCE MAIN SSMH SANITARY SEWER MANHOLE UBC UNIFORM BUILDING CODE WM WATER METER XFMR TRANSFORMER WSDOT WASHINGTON STATE DEPARTMENT OF TRANSPORTATION CIVIL ABBREVIATIONS BUILDING LEGEND SANITARY SEWER PIPE PROPERTY BOUNDARY WATER MAIN12" DI W FH/FDC/PIV/VALVE WATER VAULT/METER FH FDC PIV W W WV AIR RELIEF VALVE SAN SAN EX CB/MH PROPOSED CENTERLINE EX RIGHT-OF-WAY EX MAJOR CONTOURS EX MINOR CONTOURS CURB AND GUTTER RETAINING WALL 202 200 CONCRETE SANITARY MANHOLE / CLEANOUT MAJOR CONTOURS100 MINOR CONTOURS102 STORM DRAINAGE PIPESDSD LANDSCAPING CATCH BASIN TYPE 1CB ROOF DOWNSPOUTDS 5D D 5DPIPE DIAMETER 'D' SEE PLAN 1' MIN 6" QUARRY ROCK PLAN VIEW ELEVATION VIEW TAPERED END (TYPICAL ALL INLETS AND OUTLETS) RIP RAP OUTFALL NTS1 STORM FILTER STORM CLEANOUTSDCO RIP RAP OUTFALL SOLID LOCKING LID PIPE SUPPORTS BAND TO SIDEWALL (IN 2 PLACES) MESH SCREEN 1/4"X 1/4" TO 1/2"X 1/2" BAND SCREEN TO PIPE 4" DIA. "T" MIN.1' MIN.1' MIN.2' MESH SCREEN 1/4"X 1/4" TO 1/2"X 1/2" BAND SCREEN TO PIPE 18" MINIMUM DIAMETER SEE NOTE 1 4' MIN.(OR LONG DIMENSION ON RECTANGULAR STRUCTURE) NOTES: 1.SET THE TOP OF THE TEE RISER AT OR ABOVE THE TOP ELEVATION OF THE TRENCH DRAIN ROCK AND BELOW THE CONNECTION POINT OF ROOF TIGHTLINE AT THE FOUNDATION. 2.SET THE BOTTOM OF THE INLET PIPE AT THE SAME ELEVATION AS THE OUTLET PIPE. 3.INSTALL SOLID LOCKING LID AT OR ABOVE EXPECTED FINAL GRADE ELEVATION TO ALLOW HOMEOWNER ACCESS FOR MAINTENANCE. 4.STRUCTURE MUST HAVE SOLID BOTTOM. 6" MIN. RESIDENT SEDIMENT CONTROL STRUCTURE NTS1 CIVIL & STRUCTURAL ENGINEERING | LAND SURVEYING | PLANNINGPROJECT MANAGEMENT | FEASIBILITY | PERMIT EXPEDITINGCORPORATE OFFICE5920 100th St SW, Ste #25Lakewood, WA 98499phone: 253-984-2900beylerconsulting.comSHEET OF JOB NUMBERNO. DESCRIPTION INIT DATEDRAWN BY:CHECKED BY:SCALE:HORZ:VERT:DATE:BEYLERCONSULTINGPlan. Design. ManageCAD FILE: X:\Projects\_2018 Projects\18.00392.00 Castro - SE Petrovitsky Rd\4Civil Engineering\Engineering Drawings\18.00392 NOTES & DETAILS.dwg PLOT DATE/TIME: 3/9/2023 6:36 PM18.0039212727 SE PETROVITSKY RDSITE IMPROVEMENTCITY OF RENTONWASHINGTON17 SECTION 23, TOWNSHIP 28 N, RANGE 05 E C3.2STORM DRAINAGE DETAILS6 NOTE: 1. USE ONLY FOR SIDE SEWER AND SERVICE DRAINS 1/8" BEND FILTER FABRIC 2" PEA GRAVEL THREADED CAP PLASTIC VALVE BOX W/ 8" DIA LID SET FLUSH W/ FINISHED LANDSCAPE GRADE 6"DIA PER PLAN WYE OR 1/8 BEND PLUG SHALL BE SEALED IN SAME MANNER AS MAIN SEWER JOINTS STORM DRAINAGE CLEANOUT NTS2 SDCO W/ CONCRETE RING 1/2" 2" RAISED LETTERS SDCO-STORM SSCO-SANITARY 1/8" RAISED 1/2" WIDE BORDER 45° (1/8) BEND FIBRE JOINT PACKING 8"Ø DIP CONC CL 5 (3/4) 12" 18"3"FINISHED GRADE @ PAVING FINISHED GRADE @ GRAVEL WALKWAY 10" 9" 8 - 3/4" 7" 7 - 3/4" 8" 15" 4" 2 - 7/8" 5/8" BUILDING WALL DOWNSPOUT PER ARCH'L PLANS GASKETED HUB AND SPIGOT ADAPTER AS REQUIRED 6" SD 6" 45° BEND 6" CLEANOUT SEE DETAIL ____ FINISHED GRADE 3' - 0" ±6" 45° BEND 6" SD DOWNSPOUT CONNECTION NTS3 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED ACCORDING TO THE STANDARD SPECIFICATIONS), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1:24 OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE BASIN HAS BEEN PLACED. TYPE 1 CATCH BASIN NTS4 ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT 30"6" OR 12"20"5"34"24"5"22"(SEE NOTE 6)26"(SEE NOTE 6)44"3"21" MIN#3 BAR EACH WAY 4" #3 BAR EACH WAY #3 BAR EACH WAY PIPE MATERIAL REINFORCED OR PLAIN CONCRETE ALL METAL PIPE * CORRUGATED POLYETHYLENE STORM SEWER PIPE PIPE ALLOWANCES CPSSP (STD. SPEC. 9-05.20) SOLID WALL PVC (STD. SPEC. 9-05.12(1) PROFILE WALL PVC (STD. SPEC. 9-05.12(2) 12" 15" 12" 15" 12" MAXIMUM INSIDE Ø 4"CONNECTION AND CONTROL DEVICE DETAIL 'A' PIPE SUPPORT DETAIL 'B' TYPE 9 MINERAL AGGREGATE W/ PORTLAND CEMENT 54" CATCH BASIN IRON LADDER IE = 390.00 12" 12" INLET PIPE RING AND COVER PER _________ 4" MIN 1'-6" MAX 4" MIN 2' MIN2' MIN6" MIN CONTROL DEVICE SEE DETAIL 'A' IE = 390.00 12" 12" OUTLET PIPE 1' - 0" MIN MAX W S EL= 64.69 PIPE SUPPORT 2 REQUIRED SEE DETAIL 'B' 6" THK GROUT ALL AROUND INOUT2' MINCINCH ANCHOR WIRE ROPE CLIP (GALV) PVC PIPE AND CROSS FLOW CONTROL STRUCTURE DEFORED 1" STEEL ROD (GALV ) OR ALUMINUM LENGTH TO FIT FLOW CONTROL STRUCTURE 4" 18" PVC PIPE CONTROL DEVICE ASSEMBLY TO BE REMOVABLE FROM INSIDE OF STRUCTURE 12" MAX NON-SHRINK GROUT PVC PIPE STUB 6" THK GROUT ALL AROUND GASKET (TYP) PVC ADAPTER W/ DOUBLE GASKET AND ADHESIVE BONDED SAND FINISH ON EXTERIOR, MIN 7" LONG CAULK SPACE BETWEEN PVC PIPE ADAPTER AND PIPE STUB PVC PIPE CROSS ORIFICE PLATE ORIFICE 0.45" Ø 2' MINSD 4, CB TYPE 2-54" CONTROL STRUCTURE NTS53"9"6'6" MIN INSTALL REDUCER FOR 12" TO 18" PIPE CONNECTION CIVIL & STRUCTURAL ENGINEERING | LAND SURVEYING | PLANNINGPROJECT MANAGEMENT | FEASIBILITY | PERMIT EXPEDITINGCORPORATE OFFICE5920 100th St SW, Ste #25Lakewood, WA 98499phone: 253-984-2900beylerconsulting.comSHEET OF JOB NUMBERNO. DESCRIPTION INIT DATEDRAWN BY:CHECKED BY:SCALE:HORZ:VERT:DATE:BEYLERCONSULTINGPlan. Design. ManageCAD FILE: X:\Projects\_2018 Projects\18.00392.00 Castro - SE Petrovitsky Rd\4Civil Engineering\Engineering Drawings\18.00392 NOTES & DETAILS.dwg PLOT DATE/TIME: 3/9/2023 6:36 PM18.0039212727 SE PETROVITSKY RDSITE IMPROVEMENTCITY OF RENTONWASHINGTON17 SECTION 23, TOWNSHIP 28 N, RANGE 05 E C3.3STORM DRAINAGE DETAILS7 OUTLET INLET NOTES 1.CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASTM C478 (AASHTO M199) AND ASTM C890 UNLESS OTHERWISE SHOWN ON PLANS OR NOTED IN THE WSDOT/APWA STANDARD SPECIFICATIONS. 2.HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 6" MIN CLEARANCE. SEE DWG NO 2-006, CATCH BASIN DETAILS. HANDHOLDS SHALL BE PLACED IN ALTERNATING GRADE RINGS OR LEVELING BRICK COURSE WITH A MIN OF ONE HANDHOLD BETWEEN THE LAST STEP AND TOP OF THE MANHOLE. 3.ALL REINFORCED CAST-IN-PLACE CONCRETE SHALL BE CLASS 4000. ALL PRECAST CONCRETE SHALL BE CLASS 4000. 4.PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE WALL THICKNESS OF 2" MIN UNUSED KNOCKOUTS NEED NOT BE GROUTED IF WALL IS LEFT INTACT. PIPES SHALL BE INSTALLED ONLY IN FACTORY KNOCKOUTS UNLESS OTHERWISE APPROVED BY THE ENGINEER. 5.KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. MAX HOLE SIZE SHALL BE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48" FOR 60" CB, 60" FOR 72" CB, 84" FOR 96" CB MIN DISTANCE BETWEEN HOLES SHALL BE 8" FOR 48", 54", AND 60" CB; 12" FOR 72" AND 96" CB. 6.CATCH BASIN FRAMES AND GRATES OR COVERS SHALL BE IN ACCORDANCE WITH SEC. 7.05 AND MEET THE STRENGTH REQUIREMENTS OF FEDERAL SPECIFICATION RR-F-621D. MATING SURFACES SHALL BE FINISHED TO ASSURE NON-ROCKING FIT WITH ANY COVER POSITION. 7.ALL BASE REINFORCING STEEL SHALL HAVE A MIN YIELD STRENGTH OF 60,000 PSI AND BE PLACED IN THE UPPER HALF OF THE BASE WITH 1" MIN CLEARANCE. 8.MIN SOIL BEARING VALUE SHALL EQUAL 3,300 POUNDS PER SQUARE FOOT. 9.FOR DETAILS SHOWING LADDER, STEPS, HANDRAILS AND TOP SLABS, SEE DWG NO 2-006. 10.SEE THE WSDOT/APWA STANDARD SPECIFICATIONS SEC. 7-05.3 FOR JOINT REQUIREMENTS. 20"x24" OR 24"Ø 6" MIN 18" MAX MAX HEIGHT = 12'12" (TYP) 48", 54", 60", 72" OR 96"2'-0" MINFRAME & GRATE OR COVER ADJUSTMENT SECTION (LEVELING BRICKS OR GRADE RINGS OPTIONAL) (2) HANDHOLDS (2) STEPS OR LADDER, ORIENT W/ INLET SO STEPS WILL CLEAR PIPES PRECAST BASE & INTEGRAL RISER 1'-0" FOR 48", 54" & 60" Ø 2'-0" FOR 72" & 96" Ø GRAVEL BACKFILL FOR FOUNDATIONS 6" MIN COMPACTED DEPTH FOR PRECAST BASE ONLY 48"Ø - 6" 54"Ø, 60"Ø, 72"Ø - 8" 96"Ø - 12" REINFORCING STEEL (FOR PRECAST BASE & INTEGRAL RISER ONLY) REINFORCING STEEL (FOR SEPARATE BASES ONLY) SEPARATE CAST IN PLACE BASE OR SEPARATE PRECAST BASE PRECAST BASE JOINT "O" RING MORTAR FILL 6" FOR SEPARATE CAST-IN-PLACE Ø SIZE SQ.IN.FT. IN EACH DIRECTION 48"54"60"72"96" 0.15 0.19 0.25 0.24 0.29Ø SIZE SQ.IN.FT. IN EACH DIRECTION 48"54"60"72"96" 0.23 0.19 0.25 0.35 0.39 CATCH BASIN TYPE 2 (48",54",60",72",84",96") NTS1 STORMFILTER CATCH BASIN DETAIL - SD 1 NTS2 SD #2 0.0162 100 YEAR 18" 7.5 ZPG 398.00 0.146 396.00 8" 396.00 8" SD #1 0.0071 100 YEAR 18" 7.5 ZPG 398.50 0.064 396.50 8" oldcastleprecast.com/wilsonville Issue Date: File Name: PO Box 323, Wilsonville, Oregon 97070-0323 Tel: (503) 682-2844 Fax: (503) 682-2657 48" MANHOLE 2016 020-48MH 48" MANHOLE 48" MANHOLE 1.0 FRAME GRADE RING RISER BASE AND COVER ECCENTRIC CONE FLAT TOP CONCENTRIC CONE JOINT DETAIL TRACT A N88°05'00"W 80.13'10.32'N88°05'00"W 140.01'6,347 SF 0.146 ACRES SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN 404 402 SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANWWWWWWWWWWWWWWWWWWWWWWWWSD SD SD SD SD SD SD SD SD SD SD S D S D SD SD S D SD SD SD SD9.8'8' (TYP)16' (TYP)11.3'ACCESS HATCH 48" MANHOLE (TYP) SEE DETAIL 1, THIS SHEET PROVIDE VENTILATION PIPES AT VAULT CORNERS SEE DETAIL 2, THIS SHEET IMPLEMENT SUBGRADE SLOPE OF 0.5% FOR SEDIMENT CONTROL PROVIDE VENTILATION PIPES AT VAULT CORNERS SEE DETAIL 2, THIS SHEET PROVIDE VENTILATION PIPES AT VAULT CORNERS SEE DETAIL 2, THIS SHEET PROVIDE VENTILATION PIPES AT VAULT CORNERS SEE DETAIL 2, THIS SHEET ACCESS HATCH 48" MANHOLE (TYP) SEE DETAIL 1, THIS SHEET BOTTOM EL 390.00 0.5%STORM FILTER #1 RIM 398.50 IE 396.50 SEE DETAIL 2/C3.3 16 LF 8" PVC SD @ 0.5% 17 LF 8" PVC SD @ 0.5% CATCH BASIN TYPE 2 W/ RELEASE STRUCTURE RIM 399.00 IE (OUT) 390.00 SEE DETAIL 5/C3.2 75 LF 12" PVC SD @ 0.5% IE (OUT) 390.00 IE (OUT) 390.00 IE 396.40 IE 395.70 10'CIVIL & STRUCTURAL ENGINEERING | LAND SURVEYING | PLANNINGPROJECT MANAGEMENT | FEASIBILITY | PERMIT EXPEDITINGCORPORATE OFFICE5920 100th St SW, Ste #25Lakewood, WA 98499phone: 253-984-2900beylerconsulting.comSHEET OF JOB NUMBERNO. DESCRIPTION INIT DATEDRAWN BY:CHECKED BY:SCALE:HORZ:VERT:DATE:BEYLERCONSULTINGPlan. Design. ManageCAD FILE: X:\Projects\_2018 Projects\18.00392.00 Castro - SE Petrovitsky Rd\4Civil Engineering\Engineering Drawings\18.00392 NOTES & DETAILS.dwg PLOT DATE/TIME: 3/9/2023 6:36 PM18.0039212727 SE PETROVITSKY RDSITE IMPROVEMENTCITY OF RENTONWASHINGTON17 SECTION 23, TOWNSHIP 28 N, RANGE 05 E C3.4STORM VAULT DETAILS8 48" MANHOLE NTS1 12" VENTILATION LID COVER VENTIALATION PIPE VENT LID/PIPE NTS2 DETENTION VAULT VENTIALATION PIPE 12" GENERAL NOTE: INSTALL 12" RISER TO SURFACE, WITH LOCKING LIDE 5 2.5 0 5 SCALE: 1" = 5' STORM DRAINAGE DETENTION VAULT PLAN 1"=5' CIVIL & STRUCTURAL ENGINEERING | LAND SURVEYING | PLANNINGPROJECT MANAGEMENT | FEASIBILITY | PERMIT EXPEDITINGCORPORATE OFFICE5920 100th St SW, Ste #25Lakewood, WA 98499phone: 253-984-2900beylerconsulting.comSHEET OF JOB NUMBERNO. DESCRIPTION INIT DATEDRAWN BY:CHECKED BY:SCALE:HORZ:VERT:DATE:BEYLERCONSULTINGPlan. Design. ManageCAD FILE: X:\Projects\_2018 Projects\18.00392.00 Castro - SE Petrovitsky Rd\4Civil Engineering\Engineering Drawings\18.00392 NOTES & DETAILS.dwg PLOT DATE/TIME: 3/9/2023 6:36 PM18.0039212727 SE PETROVITSKY RDSITE IMPROVEMENTCITY OF RENTONWASHINGTON17 SECTION 23, TOWNSHIP 28 N, RANGE 05 E C3.5STORM VAULT DETAILS9 IF VAULT FLOOR IS FLAT, MANUAL ASKS THAT REMOVABLE PANELS BE PROVIDED TO REMOVE SEDIMENT, OTHERWISE SLOPE BOTTOM TO A SINGLE LOCATION FOR SEDIMENT REMOVAL